Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Performance analysis of pulse Doppler digital radars with application to the Shuttle Ku-band system

A pulse Doppler digital radar is one of the primary components of the Ku-band integrated radar and communication equipment on the Space Shuttle. The performance of the Ku-band rendezvous radar to be used on the Space Shuttle is analyzed in four parts. First an overall functional block diagram description is presented to illustrate the signal processing in the detection and the tracking modes. The detection capabilities and limitations of the radar are investigated taking all of the system losses into account. A new unified analysis of digital radar tracking loops is developed which takes into consideration the effects of a scintillating target and receiver front end noise. The behavior of the radar is discussed in the presence of thermal noise, amplitude scintillation, and target glint.

Alem, W. K.↗

Performance Analysis of Electrodynamic Screens Based on Residual Particle Size Distribution

Dust accumulation on the optical surfaces of solar collectors causes significant losses in their energy yield. Fine dust particles, compared with coarse ones, contribute significantly more in the performance loss, assuming identical surface mass concen- tration. This study examines the performance of different electro- dynamic screen (EDS) prototypes, operated under different con- ditions, in removing fine dust particles in the laboratory environ- ment. After going through several cycles of dust deposition and cleaning using EDS, the dust residue left on each EDS prototype is collected and analyzed using a Horiba particle size distribution (PSD) analyzer. The PSD analyses determine which EDS design has performed superior in removing a given size range and in which operational condition. Here, the results are advantageous in the optimization procedure of EDS to attain maximum dust removal efficiency and minimum optical interference.

14 SOLAR ENERGY↗

Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

20 FOSSIL-FUELED POWER PLANTS↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Performance of Compressor of XJ-41-V Turbojet Engine V-Performance Analysis of Compressor with Revised Vaned Collector over Range of Compressor Speeds from 3600 to 11,500 RPM

An investigation of the XJ-41-V turbojet-engine compressor with a revised vaned collector was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal compressors of this type. The original vaned collector was revised by increasing the flow area at the vaned collector entrance. A maximum adiabatic efficiency of 0.81 was obtained et a corrected weight flow of 36.5 pounds per second and a pressure ratio of 1.90. The peak pressure ratio was 3.93 and occurred at an impeller speed of 11,500 rpm at a corrected weight flow of 65.5 pounds per second. Revision of the vaned collector resulted in an increased airflow capacity over the speed range. The design air-flow capacity of 78 pounds per second was very nearly reached at the engine design speed of 11,500 rpm. The compressor air-flow choking point occurred in the vaned collector passage; however, at speeds above 8300 rpm, the air-flow capacity of the impeller was being approached as indicated by large pressure losses in the impeller at maximum air-flow conditions. An increase in compressor air-flow capacity at the higher speeds can possibly be obtained 5y removal of the flow restriction in the impeller, which would result in an increased air density at the vaned collector entrance.

Ginsburg, Ambrose↗

Composition-Nanoarchitecture-Performance Analysis of High Energy Density Electrodeposited Silicon for Lithium-Ion Battery Anodes

Electrodeposition of silicon (Si) was previously demonstrated as a promising method for fabricating 3D-structured lithium-ion battery anodes. However, the relationship between the electrochemical performance and chemical composition of the relatively impure electrodeposited silicon is not well understood. Here, we report the electrodeposition of a Si-dominant active material (EDEP-Si) onto 3D-structured nickel (Ni) scaffolds and systematically compare the electrochemical properties, elemental composition, atomistic Si coordination, and molecular structure of EDEP-Si with high-purity amorphous Si grown via static chemical vapor deposition. Despite the considerable amount of carbon (9–11 at %) and oxygen (42–44 at %) present in EDEP-Si, the cycling stability and high reversible specific capacity are remarkably similar to those of CVD-Si on a silicon basis (~2400 mA h/g-Si after 100 cycles). The primary difference is that EDEP-Si exhibits reduced cycling efficiency over the first 10–20 cycles. Reactions between carbon and, more importantly, oxygen in EDEP-Si with lithium are likely responsible for the reduced early cycle performance and lower capacity of the total deposit. Finally, our observations suggest ultrapure Si is not necessary for high electrochemical access to reversible charge storage, although limiting the presence of incorporated impurity species would improve energy density and first cycle efficiency.

25 ENERGY STORAGE↗

Human Performance Analysis Depending on Operator Expertise (Student vs. Operator) and Simulator Complexity (Rancor Microworld vs. Compact Nuclear Simulator)

Human reliability analysis (HRA) evaluates human errors and provides human error probabilities (HEPs) for application in probabilistic safety assessment (PSA), which is a comprehensive safety assessment method for nuclear power plants (NPPs). Generally, HRA methods estimate HEPs based on human reliability data collected from actual historical measurement, simulator experiments, or expert judgement. Most recent HRA data collection studies focus on collecting data via full-scope main control room (MCR) simulators with actual licensed reactor operators. Contrary to this, Idaho National Laboratory (INL) has adopted a different approach, which attempts to collect HRA data based on experiment using simplified simulators and student participants by following the Simplified Human Error Experimental Program (SHEEP). This approach has a couple of advantages compared to full-scope data collection. Representatively, it has relatively low entry point for collecting HRA data, and secures large sample sizes with reasonable cost and labor. In the previous studies, we developed the SHEEP framework, then verified whether the data collected through the framework could support a representative full-scope data collection study, i.e., the Human Reliability Data Extraction (HuREX) study. Also, we analyzed human performance measurements depending on participant type (i.e., student vs. operator). In this paper, we analyze human performance data collected from an experiment comparing operator expertise and simulator complexity when using the more simplified simulator developed by INL, i.e., Rancor Microworld and the less simplified simulator, i.e., Compact Nuclear Simulator (CNS) developed by Korea Atomic Energy Research Institute (KAERI). Analysis of variance (ANOVA) tests and correlation analysis are used for analyzing the experimental data.

99 GENERAL AND MISCELLANEOUS↗

Fuel performance analysis of Cr-coated Zircaloy-4 cladding during a prototypical LOCA event using BISON

Here, deformation and failure of chromium (Cr) coated Zircaloy-4 (Zry-4) were studied in loss-of-coolant accident (LOCA) conditions using the BISON fuel performance code. The BISON validation model simulating Halden research reactor experiments was extended to include Cr coatings and higher rod internal pressures to simulate high-burnup fuel. The transient simulations show Cr coatings help relieve stress in the Zry-4 substrate during the transient, delaying the onset of high-temperature creep, which leads to ballooning and bursting of the cladding. A nominal Cr coating thickness of 30 µm delays clad failure by 26 seconds and increases the clad burst temperature by 40 K. A parametric study showed that time to failure and burst temperature both increase with coating thickness, and Cr-coated cladding offers burst resistance under a wide range of rod internal pressures simulating high-burnup fuel. Results indicate that a thin Cr coating provides resistance against ballooning and bursting of cladding during LOCA events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance analysis of flexible DSSC with binder addition

Flexible DSSC is one of modification of DSSC based on its substrate. Operating at low temperature, flexible DSSC requires a binder to improve particles interconnection. This research was done to compare the morphology and performance of flexible DSSC that was produced with binder-added and binder-free. TiO{sub 2} powder, butanol, and HCl were mixed for preparation of TiO{sub 2} paste. Small amount of titanium isopropoxide as binder was added into the mixture. TiO{sub 2} paste was deposited on ITO-PET plastic substrate with area of 1x1 cm{sup 2} by doctor blade method. Furthermore, SEM, XRD, and BET characterization were done to analyze morphology and surface area of the TiO{sub 2} photoelectrode microstructures. Dyed TiO{sub 2} photoelectrode and platinum counter electrode were assembled and injected by electrolyte. In the last process, flexible DSSCs were illuminated by sun simulator to do J-V measurement. As a result, flexible DSSC containing binder showed higher performance with photoconversion efficiency of 0.31%.

14 SOLAR ENERGY↗

An Introduction to Thermodynamic Performance Analysis of Aircraft Gas Turbine Engine Cycles Using the Numerical Propulsion System Simulation Code

This document is intended as an introduction to the analysis of gas turbine engine cycles using the Numerical Propulsion System Simulation (NPSS) code. It is assumed that the analyst has a firm understanding of fluid flow, gas dynamics, thermodynamics, and turbomachinery theory. The purpose of this paper is to provide for the novice the information necessary to begin cycle analysis using NPSS. This paper and the annotated example serve as a starting point and by no means cover the entire range of information and experience necessary for engine performance simulation. NPSS syntax is presented but for a more detailed explanation of the code the user is referred to the NPSS User Guide and Reference document (ref. 1).

Jones, Scott M.↗

Models of weather effects on noise temperature and attenuation for Ka- and X-band telemetry performance analysis

Models that show the effects of weather on noise temperature and attenuation of deep space telemetry signals received by the Deep Space Network (DSN) at Ka- and X-band (32 and 8.5 GHz) are developed. These models were used to compare the performance of telemetry links at these two frequencies. The models build on an earlier 1982 model that used three months of water vapor radiometer measurements (31.4 GHz) at Goldstone, augmented with one year of radiosonde measurements made at Edwards Air Force Base. This 1986 model accounts for annual variations of rainfall and extends to a model for Canberra, Australia, and Madrid, Spain. The results show, for example, that at Ka-band, 30 degrees elevation angle, Goldstone weather adds less than 23 + or - 2 K to the system temperature 80% of the time, while Canberra or Madrid weather adds less than 32 + or - 5 K 80% of the time. At X-band, the comparable numbers are 5.1 + or - 0.2 K and 5.7 + or - 0.4 K. A simple analysis shows a substantial telemetry system signal-to-noise ratio advantage when operating at Ka-band compared to X-band.

Slobin, S. D.↗

Fabrication and performance analysis of 4-sq cm indium tin oxide/InP photovoltaic solar cells

Large-area photovoltaic solar cells based on direct current magnetron sputter deposition of indium tin oxide (ITO) into single-crystal p-InP substrates demonstrated both the radiation hardness and high performance necessary for extraterrestrial applications. A small-scale production project was initiated in which approximately 50 ITO/InP cells are being produced. The procedures used in this small-scale production of 4-sq cm ITO/InP cells are presented and discussed. The discussion includes analyses of performance range of all available production cells, and device performance data of the best cells thus far produced. Additionally, processing experience gained from the production of these cells is discussed, indicating other issues that may be encountered when large-scale productions are begun.

Gessert, T. A.↗

Interface Problem Formulation Improvements with Application to Nuclear Fuel Performance Analysis

The U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation Program aims to develop predictive capabilities by applying computational methods to the analysis and design of advanced reactor and fuel cycle systems. This program has been providing engineering scale support for the development of BISON, a high-fidelity and high-resolution fuel performance tool. This report documents new developments and robustness improvements in mechanical and thermal (gap heat transfer) contact formulations. The improvements range from the migration of industrial level (“assessment”) nuclear fuel model setups to the usage of mortar formulations, the addition of frictional contact to one-dimensional layered representations of fuel and cladding components, and the addition of the Petrov-Galerkin approach to dual mortar, which improves performance on curved, relatively coarse meshes. In addition, the Lagrange-multiplier enforcement of mechanical mortar contact constraints has been extended to two additional types of enforcement: penalty and augmented Lagrange-Uzawa. We show that the latter approach yields the same interface results as dual mortar in the Multiphysics Object-Oriented Simulation Environment, with the advantage of not worsening the condition number of the system matrix—thereby enabling the use of some general implementations of iterative preconditioners, at the expense of additional system evaluations (i.e., augmentations).

42 ENGINEERING↗

Noise adding radiometer performance analysis

The DSN noise adding radiometer (NAR) measurement accuracy is analyzed. The NAR capability is part of the precision power monitor function recently introduced in the DSN. The potential system noise temperature measurement accuracy is estimated to be about 1.5% with the 1 kelvin noise diode. Performance verification requires comparison noise temperature measurements with the manual Y factor method and routine monitoring of critical elements in the NAR system such as system linearity and noise diode calibration. A technique is presented to calibrate and reduce the effects of the receiving system nonlinearity. Unsatisfactory performance or degradation of these critical NAR elements would require appropriate system upgrading.

Stelzried, C.↗

Performance analysis of a hybrid ARQ error control scheme for near earth satellite communications

A robust error control coding scheme is presented. The scheme is a cascaded forward error correction (FEC) scheme supported by parity retransmissions for further error correction in the erroneous data words. The error performance and throughput efficiency of the scheme are analyzed. Two specific schemes are proposed for NASA near earth satellite communications. It is shown that both schemes provide high reliability and throughput efficiency even for high channel bit error rates in the range of .002. The schemes are suitable for high data rate file transfer.

Lin, Shu↗

Preliminary performance analysis of an interplanetary navigation system using asteroid based beacons

A futuristic interplanetary navigation system using transmitters placed on selected asteroids is introduced. This network of space beacons is seen as a needed alternative to the overly burdened Deep Space Network. Covariance analyses on the potential performance of these space beacons located on a candidate constellation of eight real asteroids are initiated. Simplified analytic calculations are performed to determine limiting accuracies attainable with the network for geometric positioning. More sophisticated computer simulations are also performed to determine potential accuracies using long arcs of range and Doppler data from the beacons. The results from these computations show promise for this navigation system.

Jee, J. Rodney↗