Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRINCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Pulse Duration of Seeded Free-Electron Lasers

The pulse duration, and, more generally, the temporal intensity profile of free-electron laser (FEL) pulses, is of utmost importance for exploring the new perspectives offered by FELs; it is a nontrivial experimental parameter that needs to be characterized. We measured the pulse shape of an extreme ultraviolet externally seeded FEL operating in high-gain harmonic generation mode. Two different methods based on the cross-correlation of the FEL pulses with an external optical laser were used. The two methods, one capable of single-shot performance, may both be implemented as online diagnostics in FEL facilities. The measurements were carried out at the seeded FEL facility FERMI. The FEL temporal pulse characteristics were measured and studied in a range of FEL wavelengths and machine settings, and they were compared to the predictions of a theoretical model. Finally, the measurements allowed a direct observation of the pulse lengthening and splitting at saturation, in agreement with the proposed theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Interpretable machine learning-guided design of Fe-based soft magnetic alloys

Here, we present a machine learning (ML) guided approach to predict saturation magnetization (𝑀 S ) and coercivity (𝐻 C ) in Fe-rich soft magnetic alloys, particularly Fe-Si-B systems. ML models trained on experimental data reveal that increasing Si and B content reduces 𝑀 S from 1.81 T (DFT ≈ 2.04 T) to ≈1.54 T (DFT ≈ 1.56T) in Fe-Si-B, which is attributed to decreased magnetic density and structural modifications. Experimental validation of ML predicted magnetic saturation on Fe-1Si-1B (2.09 T), Fe-5Si-5B (2.01 T), and Fe-10Si-10B (1.54 T) alloy compositions further supports our findings. These trends are consistent with density functional theory predictions, which link increased electronic disorder and band broadening to lower 𝑀 S values. Experimental validation on selected alloys confirms the predictive accuracy of the ML model, with good agreement across compositions. Beyond predictive accuracy, detailed uncertainty quantification and model interpretability including through feature importance and partial dependence analysis reveal that 𝑀 S is governed by a nonlinear interplay between Fe content and early transition metal ratios, while 𝐻 C is more sensitive to processing conditions such as ribbon thickness and thermal treatment windows. The ML framework was further applied to Fe-Si-B/Cr/Cu/Zr/Nb alloys in a pseudoquaternary compositional space, which shows comparable magnetic properties to NANOMET (Fe 84.8 ⁢Si 0.5 ⁢B 9.4 ⁢Cu 0.8⁢ P 3.5 ⁢C 1 ), FINEMET (Fe 73.5 ⁢Si 13.5 ⁢B 9 Cu 1 ⁢Nb 3 ), NANOPERM (Fe 88 ⁢Zr 7⁢ B 4 ⁢Cu 1 ), and HITPERM (Fe 44 ⁢Co 44 ⁢Zr 7⁢ B 4 ⁢Cu 1 . Our findings demonstrate the potential of the ML framework for accelerated search of high-performance soft magnetic materials.

density functional theory↗

Reduced peripheral activity leading to hepato‐preferential action of basal insulin peglispro compared with insulin glargine in patients with type 1 diabetes

Aims Basal insulin peglispro ( BIL ), a novel PEGylated basal insulin with a large hydrodynamic size, has a delayed absorption and reduced clearance that prolongs the duration of action. The current study compared the effects of BIL and insulin glargine ( GL ) on endogenous glucose production ( EGP ), glucose disposal rate ( GDR ) and lipolysis in patients with type 1 diabetes. Materials and Methods This was a randomized, open‐label, four‐period, crossover study. Patients received intravenous infusions of BIL and GL , each at two dose levels selected for partial and maximal suppression of EGP , during an 8 to 10 h euglycemic clamp procedure with d ‐[3‐ 3 H] glucose. Results Following correction for equivalent human insulin concentrations ( EHIC ), low‐dose GL infusion resulted in similar EGP at the end of the clamp compared to low‐dose BIL infusion ( GL / BIL ratio of 1.03) but a higher GDR ( GL / BIL ratio of 2.42), indicating similar hepatic activity but attenuated peripheral activity of BIL . Consistent with this, the EHIC ‐corrected GDR / EGP at the end of the clamp was 1.72‐fold greater for GL than BIL following low‐dose administration. At the lower dose of BIL and GL (concentrations in the therapeutic range), BIL produced less suppression of lipolysis compared with GL as indicated by free fatty acid and glycerol levels at the end of the clamp. Conclusions Compared with GL , BIL restored the hepato‐peripheral insulin action gradient seen in normal physiology via its peripherally restricted action on target tissues related to carbohydrate and lipid metabolism.

Mudaliar, S.↗

Photon Doppler velocimetry surface return study for common surface preparations

Photon Doppler velocimetry (PDV) is a ubiquitous diagnostic method in dynamic compression experiments. It typically requires the roughening of the test surface to ensure scattering of the probe light back into the PDV probe at non-normal angles of incidence. Although surface scattering plays an essential role in the quality of PDV data, surface scattering properties for common materials and preparations have not previously been studied with specific relevance to PDV. Here, we present detailed measurements of the bidirectional reflectance distribution function for four different surface preparations (Scotch-Brite hand and drill roughened, ball-rolled, and grit blasted) and four different materials (copper, aluminum, stainless steel, and tantalum). These measurements employ a conventional PDV probe and obtain a diffraction limited angular resolution with 10 pW accuracy and 2.6% repeatability. In addition to scattering data, we employ scattering theory and simulations to accurately emulate the measured data. We also present a straightforward method to derive the average scattering distribution from surface profilometry and observe several qualitative aspects of the scattering data that may help to optimize PDV signals.

42 ENGINEERING↗

SU-D-BRF-07: Ultrasound and Fluoroscopy Based Intraoperative Image-Guidance System for Dynamic Dosimetry in Prostate Brachytherapy

Purpose: Prostate brachytherapy is a common treatment method for low-risk prostate cancer patients. Intraoperative treatment planning is known to improve the treatment procedure and the outcome. The current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. We developed an image-guidance system to fulfill this need to achieve intraoperative dynamic dosimetry in prostate brachytherapy. Methods: Our system is based on standard imaging equipments available in the operating room, including the transrectal ultrasound (TRUS) and the mobile C-arm. A simple fiducial is added to compute the C-arm pose. Three fluoroscopic images and an ultrasound volume of the seeds and the prostate are acquired and processed by four image processing algorithms: seed segmentation, fiducial detection with pose estimation, seed reconstruction, and seeds-to-TRUS registration. The updated seed positions allow the physician to assess the quality of implantation and dynamically adjust the treatment plan during the course of surgery to achieve improved exit dosimetry. Results: The system was tested on 10 phantoms and 37 patients. Seed segmentation resulted in a 1% false negative and 2% false positive rates. Fiducial detection with pose estimation resulted in a detection rate of 98%. Seed reconstruction had a mean reconstruction error of 0.4 mm. Seeds-to-TRUS registration had a mean registration error of 1.3 mm. The total processing time from image acquisition to registration was approximately 1 minute. Conclusion: We present an image-guidance system for intraoperative dynamic dosimetry in prostate brachytherapy. Using standard imaging equipments and a simple fiducial, our system can be easily adopted in any clinics. Robust image processing algorithms enable accurate and fast computation of the delivered dose. Especially, the system enables detection of possible hot/cold spots during the surgery, allowing the physician to address these in the operating room rather than requiring additional therapy afterwards. This research was supported in part by the National Institutes of Health/National Cancer Institute (NIH/NCI) under grant 2R44CA099374 and grant 1R01CA151395, and in part by the Department of Defense (DoD) under grant W81XWH-05-1-0407.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy

Purpose: Brachytherapy is a standard option of care for prostate cancer patients but may be improved by dynamic dose calculation based on localized seed positions. The American Brachytherapy Society states that the major current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. An image-guidance system was therefore developed to localize seeds for dynamic dose calculation. Methods: The proposed system is based on transrectal ultrasound (TRUS) and mobile C-arm fluoroscopy, while using a simple fiducial with seed-like markers to compute pose from the nonencoded C-arm. Three or more fluoroscopic images and an ultrasound volume are acquired and processed by a pipeline of algorithms: (1) seed segmentation, (2) fiducial detection with pose estimation, (3) seed matching with reconstruction, and (4) fluoroscopy-to-TRUS registration. Results: The system was evaluated on ten phantom cases, resulting in an overall mean error of 1.3 mm. The system was also tested on 37 patients and each algorithm was evaluated. Seed segmentation resulted in a 1% false negative rate and 2% false positive rate. Fiducial detection with pose estimation resulted in a 98% detection rate. Seed matching with reconstruction had a mean error of 0.4 mm. Fluoroscopy-to-TRUS registration had a mean error of 1.3 mm. Moreover, a comparison of dose calculations between the authors’ intraoperative method and an independent postoperative method shows a small difference of 7% and 2% forD{sub 90} and V{sub 100}, respectively. Finally, the system demonstrated the ability to detect cold spots and required a total processing time of approximately 1 min. Conclusions: The proposed image-guidance system is the first practical approach to dynamic dose calculation, outperforming earlier solutions in terms of robustness, ease of use, and functional completeness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solid-state polymer-particle hybrid electrolytes: Structure and electrochemical properties

Solid-state electrolytes (SSEs) are challenged by complex interfacial chemistry and poor ion transport through the interfaces they form with battery electrodes. Here, we investigate a class of SSE composed of micrometer-sized lithium oxide (Li 2 O) particles dispersed in a polymerizable 1,3-dioxolane (DOL) liquid. Ring-opening polymerization (ROP) of the DOL by Lewis acid salts inside a battery cell produces polymer-inorganic hybrid electrolytes with gradient properties on both the particle and battery cell length scales. These electrolytes sustain stable charge-discharge behavior in Li||NCM811 and anode-free Cu||NCM811 electrochemical cells. On the particle length scale, Li 2 O retards ROP, facilitating efficient ion transport in a fluid-like region near the particle surface. On battery cell length scales, gravity-assisted settling creates physical and electrochemical gradients in the hybrid electrolytes. By means of electrochemical and spectroscopic analyses, we find that Li 2 O particles participate in a reversible redox reaction that increases the effective CE in anode-free cells to values approaching 100%, enhancing battery cycle life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

Isopod (inverse Optimization And Design): Moose-based Application For Performing Inverse Optimization On Multiphysics Modeling And Simulation

ISOPOD (InverSe OPtimizatiOn and Design) will be a MOOSE (Multiphysics Object Oriented Simulation Environment)-based framework which will iteratively estimate the parameters by minimizing the difference between simulated and experimental observables. While inverse optimization has long been used for parameter estimation, the unique feature of ISOPOD is rapid solution of new inverse problems, leading to accelerated Research, Development and Demonstration (RD&D) for complex parameter estimation problems. This will be achieved by extending the software structure of MOOSE to inverse optimization, as well as building on the unique automatic differentiation feature of MOOSE.

Munday, LynnB↗

Griffin-m

Griffin-m is a MOOSE-based reactor multiphysics application that streamlines the analysis of a variety of nuclear multiphysics simulations, including steady-state and transient radiation transport, core performance, fuel depletion, criticality and decay heat calculations, reprocessing and post-irradiation examination. This streamlining is accomplished via enhanced flexibility of the tools, uniform syntax in the MOOSE framework, dynamic linking of all relevant physics and a single point of execution. The design for flexible multi-physics, multi-radiation, multi-scheme tasks demands and ultimately makes Griffin-m a highly extendable code system. A software quality assurance (SQA) procedure is enforced during Griffin-m development. The Griffin-m version will be the main production version and it includes the MCC3 code, which was originally developed at Argonne National Laboratory to prepare cross sections for fast reactors.

Ortensi, Javier [Idaho National Laboratory (INL), ↗

CALMS: CONTEXT-AWARE LANGUAGE MODEL FOR SCIENCE

Context-Aware Language Model for Science (CALMS) is designed to assist scientists with instrument operations and complex experimentation. CALMS consists of a large-language model (LLM) augmented with context and tool use abilities. With the ability to retrieve relevant information from facility documentation, CALMS can answer simple questions on scientific capabilities and other operational procedures. With the ability to interface with software tools and experimental hardware, CALMS can operate scientific instruments in a conversational manner.

CHERUKARA, MATTHEW↗

AqNWB v0.1

This is a C ++ acquisition API for neurophysiological data in the NeurodataWithoutBorders (NWB) data standard.

Prince, Stephanie↗

SFold v0.1

This is a scientific software package to integrate Small Angle X-ray Scattering (SAXS) experimental data into OpenFold deep learning models to improve protein structure prediction.

Prince, Stephanie [Lawrence Berkeley National Labo↗

An Open-source Llm Enhanced-tool Specialized In Helping Moose Related Problems And Tasks

MOOSEenger is an open-source, terminal-first chat application for the MOOSE ecosystem that couples specialized parsing of MOOSE documentation and “.i” input files with retrieval-augmented generation to deliver grounded answers about multiphysics modeling and workflows. It includes dedicated readers for MOOSE-style HTML and a pyhit-based parser that uses the MOOSE syntax tree to preserve block structure and attach retrieval metadata. A data-ingestion pipeline performs semantic chunking into atomic facts and stores them hierarchically in a local Chroma vector database that maintains parent–child relationships across documents; the system can ingest directories, individual files, and single-page web content, and it provides CRUD operations (insert, update, delete) to manage the corpus. At query time, relevant chunks are embedded, retrieved, and fused into the model context, with interactive features such as token streaming, persistent chat history, and dynamic RAG (retrieval triggered by user input or intermediate model output). Deployment is flexible: MOOSEenger runs with local Ollama models or remote Hugging Face/OpenAI backends—typically coordinating generation, lightweight tagging/summarization, and embeddings across three models—and it also supports a server mode and integration with the VS Code Continue interface.

Li, Mengnan [Idaho National Laboratory (INL), Idah↗

Griffin: A Moose-based Reactor Multiphysics Application For Radiation Transport And Depletion Simulations

Griffin is a MOOSE-based reactor multiphysics application that streamlines the analysis of a variety of nuclear multiphysics applications, including steady-state and transient radiation transport, core performance, fuel depletion, criticality and decay heat calculations, reprocessing and post-irradiation examination. This streamlining is accomplished via enhanced flexibility of the tools, uniform syntax in the MOOSE framework, dynamic linking of all relevant physics and a single point of execution. The design for flexible multi-physics, multi-radiation, multi-scheme tasks demands and ultimately makes Griffin a highly extendable code system. A software quality assurance (SQA) procedure is enforced during Griffin development.

DeHart, MarkD.↗