Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Operational Performance Characteristics of an Aerated L-valve Operated Within a Closed Circulating Fluidized Bed Loop

An experimental study was conducted in a large scale circulating fluidized bed (0.3 m diameter ×15.5 m tall) equipped with nonmechanical L-valve (0.25 m diameter ×1.52 m long) varying the riser superficial gas velocity (U g ), bed inventory (m), L-valve aeration velocity (U Lvalve ) and standpipe aeration velocity (U move ). The effects of these operational parameters on pressure drop were investigated in each of the different components in the CFB and on the solid circulation rate with two different Group B particles (180 μm glass bead and 750 μm phosphorescent polyethylene beads, PPE). Tests were carried out at ambient temperature and pressure conditions using air as the fluidization gas. The operating parameters were shown to significantly affect pressure drops across various sections of the CFB due to redistribution of solids within the system. The pressure drop in the horizontal section of the L-valve was affected by aeration rates in addition to the solid flow rate reported in previous studies of smaller L-valves without aeration. A new dimensionless semi-empirical correlation was able to explain > 98% of the variance between pressure drop across the horizontal section of the L-valve and operating parameters for these Group B particles. The results of present study indicated that the nonmechanical L-valve cannot be isolated from the CFB system for performance evaluation.

Monazam, Esmail R.↗

Pumping power considerations in the designs of NASA-Redox flow cells

Pressure drop data for six different cell geometries of various flow port, manifold, and cavity dimensions are presented. The redox/energy/storage system uses two fully soluble redox couples as anode and cathode fluids. Both fluids are pumped through a redox cell, or stack of cells, where the electrochemical reactions take place at porous carbon felt electrodes. Pressure drop losses are therefore associated with this system due to the continuous flow of reactant solutions. The exact pressure drop within a redox flow cell is directly dependent on the flow rate as well as the various cell dimensions. Pumping power requirements for a specific set of cell operating conditions are found for various cell geometries once the flow rate and pressure drop are determined. These pumping power requirements contribute to the overall system parasitic energy losses which must be minimized, the choice of cell geometry becomes critical.

Hoberecht, M. A.↗

GRB 080503 LATE AFTERGLOW RE-BRIGHTENING: SIGNATURE OF A MAGNETAR-POWERED MERGER-NOVA

GRB 080503 is a short gamma-ray burst (GRB) detected by Swift and has been classified as a GRB originating from a compact star merger. The soft extended emission and the simultaneous late re-brightening in both the X-ray and optical afterglow light curves raise interesting questions regarding its physical origin. We show that the broadband data of GRB 080503 can be well explained within the framework of the double neutron star merger model, provided that the merger remnant is a rapidly rotating massive neutron star with an extremely high magnetic field (i.e., a millisecond magnetar). We show that the late optical re-brightening is consistent with the emission from a magnetar-powered “merger-nova.” This adds one more case to the growing sample of merger-novae associated with short GRBs. The soft extended emission and the late X-ray excess emission are well connected through a magnetar dipole spin-down luminosity evolution function, suggesting that direct magnetic dissipation is the mechanism to produce these X-rays. The X-ray emission initially leaks from a hole in the merger ejecta pierced by the short GRB jet. The hole subsequently closes after the magnetar spins down and the magnetic pressure drops below ram pressure. The X-ray photons are then trapped behind the merger-nova ejecta until the ejecta becomes optically thin at a later time. This explains the essentially simultaneous re-brightening in both the optical and X-ray light curves. Within this model, future gravitational-wave sources could be associated with a bright X-ray counterpart along with the merger-nova, even if the short GRB jet beams away from Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement of two-phase closure models in CTF using Bayesian inference

Under the Consortium for Advanced Simulation of Light Water Reactors (CASL) program, extensive capabilities have been developed in CTF to analyze light-water reactors (LWRs) for normal operating conditions, departure from nucleate boiling (DNB), and system transients. However, further improvements are required in the modeling and simulation of boiling water reactors (BWRs), which is a focus of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this work, CTF validation results were used to optimize selected modeling coefficients by calibrating to experimental data using a Bayesian inference approach. Here, calibration studies were conducted to improve (vapor) void fraction prediction without worsening the two-phase pressure drop prediction, as well as to improve the two-phase pressure drop prediction. Calibration was performed for interfacial drag and wall shear models. Surrogates were developed to alleviate the computational expense required for sampling the parameter space using Markov chain Monte Carlo (MCMC). An assessment performed with calibrated models demonstrated an improvement of CTF in its prediction of key parameters such as void fraction and two-phase pressure drop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modelling a compressible packed bed flow-through washing and deacetylation reactor for corn stover pretreatment

The deacetylation process is a key step in the lignocellulosic biomass pretreatment process that currently is done in batch reactors. A flow-through diffuser type reactor is a promising approach to make the process more efficient and economically favorable. A washing step before deacetylation can further reduce chemical usage and increase the process efficiency. However, the highly compacted biomass particles can cause significant pressure-drop for fluid flow through the bed, which in the worst case can cause self-enhancing pressure-drop leading to reactor blocking. Detailed understanding of the fundamentals of flow through a compressible packed bed is necessary to scale up the washing and deacetylation process. This work closely examines the classical Kozeny Carman equation and proposes modifications to accurately predict the pressure-drop at different compaction states. Here, a compressible packed bed model is further developed based on the interaction between solid mechanics and fluid dynamics. Experimental measurements of water flow through a packed bed of corn stover show good agreement with the developed model. Corn stover washing process scale up simulations show that smaller reactor diameter, higher friction lining material, lower process throughput, and higher process temperature is favorable in stabilizing the bed from extensive compression when the bed height is fixed.

09 BIOMASS FUELS↗

Altitude Cooling Investigation of the R-2800-21 Engine in the P-47G Airplane. IV - Engine Cooling-Air Pressure Distribution

A study of the data obtained in a flight investigation of an R-2800-21 engine in a P-47G airplane was made to determine the effect of the flight variables on the engine cooling-air pressure distribution. The investigation consisted of level flights at altitudes from 5000 to 35,000 feet for the normal range of engine and airplane operation. The data showed that the average engine front pressures ranged from 0.73 to 0.82 of the impact pressure (velocity head). The average engine rear pressures ranged from 0.50 to 0.55 of the impact pressure for closed cowl flaps and from 0.10 to 0.20 for full-open cowl flaps. In general, the highest front pressures were obtained at the bottom of the engine. The rear pressures for the rear-row cylinders were .lower and the pressure drops correspondingly higher than for the front-row cylinders. The rear-pressure distribution was materially affected by cowl-flap position in that the differences between the rear pressures of the front-row and rear-row cylinders markedly increased as the cowl flaps were opened. For full-open cowl flaps, the pressure drops across the rear-row cylinders were in the order of 0.2 of the impact pressure greater than across the front-row cylinders. Propeller speed and altitude had little effect on the -coolingair pressure distribution, Increase in angle of inclination of the thrust axis decreased the front ?pressures for the cylinders at the top of the engine and increased them for the cylinders at the bottom of the engine. As more auxiliary air was taken from the engine cowling, the front pressures and, to a lesser extent, the rear pressures for the cylinders at the bottom of the engine decreased. No correlation existed between the cooling-air pressure-drop distribution and the cylinder-temperature distribution.

Kaufman, Samuel J.↗

Condensation in horizontal heat exchanger tubes

Many innovative reactor concepts for Generation III nuclear power plants use passive safety equipment for residual heat removal. These systems use two phase natural circulation. Heat transfer to the coolant results in a density difference providing the driving head for the required mass flow. By balancing the pressure drop the system finds its operational mode. Therefore the systems depend on a strong link between heat transfer and pressure drop determining the mass flow through the system. In order to be able to analyze these kind of systems with the help of state of the art computer codes the implemented numerical models for heat transfer, pressure drop or two phase flow structure must be able to predict the system performance in a wide parameter range. Goal of the program is to optimize the numerical models and therefore the performance of computer codes analyzing passive systems. Within the project the heat transfer capacity of a heat exchanger tube will be investigated. Therefore the tube will be equipped with detectors, both temperature and pressure, in several directions perpendicular to the tube axis to be able to resolve the angular heat transfer. In parallel the flow structure of a two phase flow inside and along the tube will be detected with the help of x-ray tomography. The water cooling outside of the tube will be realized by forced convection. It will be possible to combine the flow structure measurement with an angular resolved heat transfer for a wide parameter range. The test rig is set up at the TOPLFOW facility at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR), so that it will be possible to vary the pressure between 5 and 70 bar. The steam mass content will be varied between 0 and 100 percent. The results will be compared to the large scaled Emergency Condenser Tests performed at the INKA test facility in Karlstein (Germany). The paper will explain the test setup and the status of the project will be presented. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Research Performance Report - Small Molecular Associative Carbon Dioxide (CO 2 ) Thickeners for Improved Mobility Control

The initial objective of this project was to promote the application of a CO 2 thickener for improved mobility control during CO 2 EOR based on solubility tests, viscosity tests, and core floods. Ultimately, it was demonstrated that the CO 2 -soluble polymeric thickeners are much better suited for use a CO 2 -soluble conformance control agents for diverting the flow of CO 2 away from thief zones. Our team generated several effective small molecule CO 2 thickeners with ARPA-e funding. Unfortunately, none of these small molecule thickeners could dissolve in CO 2 without the addition of unacceptably large amounts of hexane or toluene as a co-solvent Therefore none were viable candidates for the core flooding studies associated with NETL award. Therefore during the entire core flood testing program associated with this NETL award, our team used only the most promising polymeric CO 2 thickener, a polyfluoroacrylate (PFA). In order to produce an environmentally benign polymer, the monomer used to make the new polymers used in this study was a fluoroacrylate that contains only six fluorinated carbons. We verified CO 2 solubility with a phase behavior cell. The thickening potential of all polymer samples was substantiated with a falling ball viscometer and a falling cylinder viscometer at Pitt. Two different viscometers were used to determine the increase in CO 2 viscosity that could be achieved via the dissolution of PFA. Praxair, which has an interest in thickening CO 2 for pilot EOR projects and for waterless hydraulic fracturing, agreed to measure the viscosity of CO 2 -PFA solutions at no cost to the project. Falling cylinder viscometery was conducted at Pitt in our windowed high pressure phase behavior cell. Both apparatuses indicated that at very low shear rates the CO 2 viscosity increased by a factor of roughly 3.5 when 1wt% PFA was dissolved in the CO 2 2. Our team also planned thickener concentrations and compositions at Pitt for the core tests that were conducted at Special Core Analysis Laboratories, Inc., (SCAL) in Midland, TX, where the ability for PFA to reduce CO 2 mobility in a core was then tested. During the beginning of these tests, the PFA polymer was then shown to impart reasonable improvements in mobility control during the SCAL core tests; as the CO 2 -PFA solution displaced CO 2 from the core at a constant volumetric flow rate, the pressure drop increased as expected. However, as the test progressed, there was clear and surprising evidence of dramatic reductions in core permeability due to PFA adsorption, especially for sandstones. For example, as the CO 2 -PFA solution displaced pure CO 2 from sandstone and limestone cores, the pressure drop increased by factors of multiple hundreds to over a thousand. It was subsequently demonstrated that the PFA injected into the core either (a) adsorbed strongly and irreversibly onto the rock surfaces, (b) deposited/precipitated within the rock, thereby blocking pores in a manner that could be dislodged by large changes in flow rate or flow direction, or (c) remained in solution and passed completely through the core. The loss of PFA to the porous media and the unacceptably large increases in pressure drop both indicated that PFA was inappropriate for CO 2 EOR mobility control, where thickener adsorption must be minimized and mobility reductions of only 10-100-fold are typically required. However, we realized that because the CO 2 -PFA solution could greatly reduce the permeability of porous media, it could serve as a near wellbore conformance control agent for blocking “thief zones”, where adsorption is acceptable and dramatic increases in pressure drop are desirable. These effects were more dramatic for sandstone than for limestone. Therefore, these PFA fluoroacrylate polymers can serve as a CO 2 -soluble conformance control agent for CO 2 -EOR, especially in sandstone formations. This injection of a single phase solution of CO 2 -PFA for permeability reduction is (to the best of our knowledge) the first report of a CO 2 -soluble conformance control additive. We also demonstrated that the optimal strategy for using CO 2 -PFA solutions for conformance control is analogous to the application of water-based polymeric gels; the CO 2 -PFA solution should first be injected only in an isolated thief zone to induce dramatic reductions in permeability only in that thief zone, and then CO 2 should be injected into all of the zones. Finally, it was noted that given the propensity of PFA to adsorb onto sandstone, the adsorption of PFA from CO 2 -PFA solutions onto cement surfaces promote the sealing of extremely fine cracks in casing cement.

02 PETROLEUM↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Coolant-Flow Calibrations of Three Simulated Porous Gas-Turbine Blades

An investigation was conducted at the NACA Lewis laboratory to determine whether simulated porous gas-turbine blades fabricated by the Eaton Manufacturing Company of Cleveland, Ohio would be satisfactory with respect to coolant flow for application in gas-turbine engines. These blades simulated porous turbine blades by forcing the cooling air onto the blade surface through a large number of chordwise openings or slits between laminations of sheet metal or wire. This type of surface has a finite number of openings, whereas a porous surface has an almost infinite number of smaller openings for the coolant flow. The investigation showed that a blade made of sheet-metal laminations stacked on a support member that passed up through the coolant passage was completely unsatisfactory because of extremely poor coolant flow distribution over the blade surface. The flow distribution for two wire-wound blades was more uniform, but the pressure drop between the coolant supply pressure and the local pressure on the outside of the blades was too low by a factor ranging from 3 to 3.5 for the required coolant flow rates. The pressure drop could be increased by forcing the wires closer together during blade fabrication.

Esger, Jack B.↗

Digital Valve for High Pressure High Flow Applications

To address the challenges, which are involved with the development of flow control valves that can meet the requirements of deep oil wells such as high pressure, high flow rate, limited power and limited space, the authors have conceived a novel design configuration [1]. This design consists of a digitalized flow control valve with multipath and multistage pressure reduction structures. Specifically, the valve is configured as a set of parallel flow paths from the inlet to the outlet. A choke valve controls the total flow rate by digitally opening different paths or different combination of the paths. Each path is controlled by a poppet cap valve basically operated in on-off states. The number of flow states is 2N where N is the number of flow paths. To avoid erosion from sand in the oil and high speed flow, the seal area of the poppet cap valve is located at a distance from the flow inlet away from the high speed flow and the speed is controlled to stay below a predefined erosion safe limit. The path is a multistage structure composed of a set of serial nozzles-expansion chambers that equally distribute the total pressure drop to each stage. The pressure drop of each stage and, therefore, the flow speed at the nozzles and expansion chambers is controlled by the number of stages. The paths have relatively small cross section and could be relatively long for large number of stages and still fit in the strict annular space limit of a typical downhole region of an oil well. The paper will present the design configuration, analysis and preliminary test results.

downhole↗

A 4DCT imaging-based breathing lung model with relative hysteresis

To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for both models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. - Highlights: • We developed a breathing human lung CFD model based on 4D-dynamic CT images. • The 4DCT-based breathing lung model is able to capture lung relative hysteresis. • A new boundary condition for lung model based on one static CT image was proposed. • The difference between lung models based on 4D and static CT images was quantified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat transfer and fluid dynamics of air-water two-phase flow in micro-channels

Heat transfer, pressure drop, and void fraction were simultaneously measured for upward heated air-water non-boiling two-phase flow in 0.51 mm ID tube to investigate thermo-hydro dynamic characteristics of two-phase flow in micro-channels. At low liquid superficial velocity j{sub l} frictional pressure drop agreed with Mishima-Hibiki's correlation, whereas agreed with Chisholm-Laird's correlation at relatively high j{sub l}. Void fraction was lower than the homogeneous model and conventional empirical correlations. To interpret the decrease of void fraction with decrease of tube diameter, a relation among the void fraction, pressure gradient and tube diameter was derived. Heat transfer coefficient fairly agreed with the data for 1.03 and 2.01 mm ID tubes when j{sub l} was relatively high. But it became lower than that for larger diameter tubes when j{sub l} was low. Analogy between heat transfer and frictional pressure drop was proved to hold roughly for the two-phase flow in micro-channel. But satisfactory relation was not obtained under the condition of low liquid superficial velocity. (author)

42 ENGINEERING↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lunar Dust Capture Using a Novel, Multiplexed Inertial Filter

Multiplexed inertial filtration is new. It holds promise to capture and contain lunar dust with less pressure drop. Even when the filter contains significant amounts of captured lunar dust, the pressure drop remains relatively low. State of the art vacuum cleaners use a system with 4 different filter: they can contain large amounts of lunar dust and maintain low pressure drop, but because they require 4 filters, the system size is relatively large. State of the are miniature vacuum cleaners are small, but the single in-line depth filter clogs easily. The goal of this CIF project is to develop a lunar dust vacuum cleaner <1000 cc in size, with high capacity and low dP.

Lunar Soil↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗