Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Recent progress in tailoring trap-based positron beams

Recent progress is described to implement two approaches to specially tailor trap-based positron beams. Experiments and simulations are presented to understand the limits on the energy spread and pulse duration of positron beams extracted from a Penning-Malmberg (PM) trap after the particles have been buffer-gas cooled (or heated) in the range of temperatures 1000 {>=} T {>=} 300 K. These simulations are also used to predict beam performance for cryogenically cooled positrons. Experiments and simulations are also presented to understand the properties of beams formed when plasmas are tailored in a PM trap in a 5 tesla magnetic field, then non-adiabatically extracted from the field using a specially designed high-permeability grid to create a new class of electrostatically guided beams.

43 PARTICLE ACCELERATORS↗

Positron production using a 1.7 MV pelletron accelerator

We report the foremost phase of a fourth generation positron source, being constructed at the Federal University of Rio de Janeiro. Positron yields are reported by making use of the {sup 19}F(p,{alpha}e{sup +}e{sup -}){sup 16}O reaction, where the fluorine target is in the form of a CaF{sub 2} pellet. Positron production has been observed by detecting 511 keV annihilation gamma rays emerging from the irradiated CaF{sub 2} target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Positron interactions with water–total elastic, total inelastic, and elastic differential cross section measurements

Utilising a high-resolution, trap-based positron beam, we have measured both elastic and inelastic scattering of positrons from water vapour. The measurements comprise differential elastic, total elastic, and total inelastic (not including positronium formation) absolute cross sections. The energy range investigated is from 1 eV to 60 eV. Comparison with theory is made with both R-Matrix and distorted wave calculations, and with our own application of the Independent Atom Model for positron interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A trap-based pulsed positron beam optimised for positronium laser spectroscopy

We describe a pulsed positron beam that is optimised for positronium (Ps) laser-spectroscopy experiments. The system is based on a two-stage Surko-type buffer gas trap that produces 4 ns wide pulses containing up to 5 × 10{sup 5} positrons at a rate of 0.5-10 Hz. By implanting positrons from the trap into a suitable target material, a dilute positronium gas with an initial density of the order of 10{sup 7} cm{sup −3} is created in vacuum. This is then probed with pulsed (ns) laser systems, where various Ps-laser interactions have been observed via changes in Ps annihilation rates using a fast gamma ray detector. We demonstrate the capabilities of the apparatus and detection methodology via the observation of Rydberg positronium atoms with principal quantum numbers ranging from 11 to 22 and the Stark broadening of the n = 2 → 11 transition in electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PAMELA positron excess as a signal from the hidden sector

The recent positron excess observed in the PAMELA satellite experiment strengthens previous experimental findings. We give here an analysis of this excess in the framework of the Stueckelberg extension of the standard model which includes an extra U(1){sub X} gauge field and matter in the hidden sector. Such matter can produce the right amount of dark matter consistent with the Wilkinson Microwave Anisotropy Probe (WMAP) constraints. Assuming the hidden sector matter to be Dirac fermions it is shown that their annihilation can produce the positron excess with the right positron energy dependence seen in the HEAT, AMS, and the PAMELA experiments. The predictions of the p/p flux ratio also fit the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of interactions of electrons and positrons with matter in MCU-PD code

The Monte Carlo method is used in the MCU code-an application package for solving equations of transport of neutrons, photons, electrons, and positrons. The code has a modular structure, and every working version of the code is formed from modules and submodules depending on the problem in question. The submodules BETA and BEG, included in the SOFIZM compound physical module of the MCU-PD code, are described: BETA submodule simulates interaction of electrons and positrons with matter and BEG submodule generates photons in the electron and positron reactions with matter. The library of constants which is involved in the MCUDB50 database and supports execution of the MCU-PD code is briefly characterized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Design of the Positron Source for the International Linear Collider

The high luminosity requirements and the option of a polarized positron beam present a great challenge for the positron source of a future linear collider. This paper provides a comprehensive overview of the latest proposed design for the baseline positron source of the International Linear Collider (ILC). We report on recent progress and results concerning the main components of the source: including the undulator, capture optics, and target.

43 PARTICLE ACCELERATORS↗

Modeling and prototyping of a flux concentrator for positron capture.

An adiabatic matching device (AMD) generates a tapered high-strength magnetic field to capture positrons emitted from a positron target to a downstream accelerating structure. The AMD is a key component of a positron source and represents a technical challenge. The International Linear Collider collaboration is proposing to employ a pulsed, normal-conducting, flux-concentrator to generate a 5 Tesla initial magnetic field. The flux-concentrator structure itself and the interactions between the flux-concentrator and the external power supply circuits give rise to a nontrivial system. In this paper, we present a recently developed equivalent circuit model for a flux concentrator, along with the characteristics of a prototype fabricated for validating the model. Using the model, we can obtain the transient response of the pulsed magnetic field and the field profile. Calculations based on the model and the results of measurements made on the prototype are in good agreement.

43 PARTICLE ACCELERATORS↗

On possible interpretations of the high energy electron–positron spectrum measured by the Fermi Large Area Telescope

The Fermi-LAT experiment recently reported high precision measurements of the spectrum of cosmic-ray electrons-plus-positrons (CRE) between 20 GeV and 1 TeV. The spectrum shows no prominent spectral features, and is significantly harder than that inferred from several previous experiments. In this paper, we discuss several interpretations of the Fermi results based either on a single large scale Galactic CRE component or by invoking additional electron–positron primary sources, e.g. nearby pulsars or particle dark matter annihilation. We show that while the reported Fermi-LAT data alone can be interpreted in terms of a single component scenario, when combined with other complementary experimental results, specifically the CRE spectrum measured by H.E.S.S. and especially the positron fraction reported by PAMELA between 1 and 100 GeV, that class of models fails to provide a consistent interpretation. Rather, we find that several combinations of parameters, involving both the pulsar and dark matter scenarios, allow a consistent description of those results. Finally, we also briefly discuss the possibility of discriminating between the pulsar and dark matter interpretations by looking for a possible anisotropy in the CRE flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of Proton Beam Range Verification Using Post-Treatment Positron Emission Tomography/Computed Tomography as Function of Treatment Site

Purpose: For 23 patients, an off-line positron emission tomography scan and a computed tomography scan after proton radiotherapy was performed at the Massachusetts General Hospital to assess in vivo treatment verification. A well-balanced population of patients was investigated to assess the effect of the tumor location on the accuracy of the technique. Methods and Materials: Range verification was achieved by comparing the measured positron emission tomography activity distributions with the corresponding Monte Carlo-simulated distributions. Observed differences in the distal end of the activity distributions were analyzed as potential indicators for the range differences between the actual delivered and planned dose. Results: The average spatial agreement between the measured and simulated activity distribution was within {+-}3 mm, and the corresponding average absolute agreement was within {+-}45% (derived from gamma index analysis). The mean absolute range deviation at 93 randomly chosen positions in 17 treatment fields delivered to 11 patients was 3.6 mm. Characteristic differences in the agreement of the measured and simulated activity distribution for the different tumor/target sites were found. This resulted from the different effect of factors such as biologic washout effects, motion, or limitations in the Monte Carlo-simulated activity patterns. Conclusion: We found that intracranial and cervical spine patients can greatly benefit from off-line positron emission tomography and computed tomography range verification. However, for the successful application of the method to patients with abdominopelvic tumors, major technological and methodologic improvements are needed. Among the intracranial and cervical spine target sites, patients with arteriovenous malformations or metal implants represent groups that could especially benefit from the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity-modulated radiotherapy. In these patients, elective nodal irradiation can be safely omitted from the planning target volume for the purposes of dose escalation and toxicity reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-Based Parameters of {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Improve Disease Recurrence Prediction in Postmastectomy Breast Cancer Patients With 1 to 3 Positive Axillary Lymph Nodes

Purpose: To determine whether volume-based parameters on pretreatment {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography in breast cancer patients treated with mastectomy without adjuvant radiation therapy are predictive of recurrence. Methods and Materials: We retrospectively analyzed 93 patients with 1 to 3 positive axillary nodes after surgery, who were studied with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography for initial staging. We evaluated the relationship between positron emission tomography parameters, including the maximum standardized uptake value, metabolic tumor volume (MTV), and total lesion glycolysis (TLG), and clinical outcomes. Results: The median follow-up duration was 45 months. Recurrence was observed in 11 patients. Metabolic tumor volume and TLG were significantly related to tumor size, number of involved nodes, nodal ratio, nuclear grade, estrogen receptor (ER) status, and triple negativity (TN) (all P values were <.05). In receiver operating characteristic curve analysis, MTV and TLG showed better predictive performance than tumor size, ER status, or TN (area under the curve: 0.85, 0.86, 0.79, 0.74, and 0.74, respectively). On multivariate analysis, MTV was an independent prognostic factor of locoregional recurrence-free survival (hazard ratio 34.42, 95% confidence interval 3.94-882.71, P=.0008) and disease-free survival (DFS) (hazard ratio 13.92, 95% confidence interval 2.65-103.78, P=.0018). The 3-year DFS rate was 93.8% for the lower MTV group (<53.1; n=85) and 25.0% for the higher MTV group (≥53.1; n=8; P<.0001, log–rank test). The 3-year DFS rate for patients with both ER-positive status and MTV <53.1 was 98.2%; and for those with ER-negative status and MTV ≥53.1 it was 25.0% (P<.0001). Conclusions: Volume-based parameters improve recurrence prediction in postmastectomy breast cancer patients with 1 to 3 positive nodes. The addition of MTV to ER status or TN has potential benefits to identify a subgroup at higher risk for recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single crystal growth of Ga[subscript 2](Se[subscript x]Te[subscript 1;#8722;x])[subscript 3] semiconductors and defect studies via positron annihilation spectroscopy

Small single crystals of Ga{sub 2}(Se{sub x}Te{sub 1-x}){sub 3} semiconductors, for x = 0.1, 0.2, 0.3, were obtained via modified Bridgman growth techniques. High resolution powder x-ray diffractometry confirms a zincblende cubic structure, with additional satellite peaks observed near the (111) Bragg line. This suggests the presence of ordered vacancy planes along the [111] direction that have been previously observed in Ga{sub 2}Te{sub 3}. Defect studies via positron annihilation spectroscopy show an average positron lifetime of {approx} 400 ps in bulk as-grown specimens. Such a large lifetime suggests that the positron annihilation sites in these materials are dominated by defects. Moreover, analyzing the electron momenta via coincidence Doppler broadening measurements suggests a strong presence of large open-volume defects, likely to be vacancy clusters or voids.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural transition in rare earth doped zirconium oxide: A positron annihilation study

Graphical abstract: New microstructural analysis and phase transition of rare earth doped mixed oxide compounds such as: Sm{sub 2−x}Dy{sub x}Zr{sub 2}O{sub 7} (where x = 0.0 ≤ x ≥ 2.0) that are potentially useful as solid oxide fuels, ionic conductors, optoelectronic materials and most importantly as radiation resistant host for high level rad-waste disposal, structural transition in the system is reported through positron annihilation spectroscopy as there is an indication in the X-ray diffraction analysis. Highlights: ► Zirconium oxide material doped with rare earth ions. ► The method of positron annihilation spectroscopy suggests a phase transition in the system. ► The crystal structure transformation from pure pyrochlore to defect fluorite type of structure is shown by X-ray diffraction results. -- Abstract: A series of compounds with the general composition Sm{sub 2−x}Dy{sub x}Zr{sub 2}O{sub 7} (where 0 ≤ x ≥ 2.0) were synthesized by chemical route and characterized by powder X-ray diffraction (XRD) analysis. The rare earth ion namely Sm{sup +3} in the compound was gradually replaced with another smaller and heavier ion, Dy{sup +3} of the 4f series, there by resulting in order–disorder structural transition, which has been studied by positron annihilation lifetime and Doppler broadening spectroscopy. This study reveals the subtle electronic micro environmental changes in the pyrochlore lattice (prevalent due to the oxygen vacancy in anti-site defect structure of the compound) toward its transformation to defect fluorite structure as found in Dy{sub 2}Zr{sub 2}O{sub 7}. A comparison of the changes perceived with PAS as compared to XRD analysis is critically assayed.

36 MATERIALS SCIENCE↗

General features of experiments on the dynamics of laser-driven electron–positron beams

The experimental study of the dynamics of neutral electron–positron beams is an emerging area of research, enabled by the recent results on the generation of this exotic state of matter in the laboratory. Electron–positron beams and plasmas are believed to play a major role in the dynamics of extreme astrophysical objects such as supermassive black holes and pulsars. For instance, they are believed to be the main constituents of a large number of astrophysical jets, and they have been proposed to significantly contribute to the emission of gamma-ray bursts and their afterglow. However, despite extensive numerical modelling and indirect astrophysical observations, a detailed experimental characterisation of the dynamics of these objects is still at its infancy. Here in this paper, we will report on some of the general features of experiments studying the dynamics of electron–positron beams in a fully laser-driven setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffusion of an annular plasma in positron acceleration

Electron acceleration to multi-GeV energies has been demonstrated using plasma wakefields in a tunnel-ionized plasma. However, coherent wakefields for positron acceleration may require hollow plasmas pre-ionized by a laser beam. The lifetime of such a plasma is determined by an unusual diffusion problem in which the diffusion rate varies by an order of magnitude inside the hole. The problem is solved by numerical differentiation without using a particle-in-cell code. The densities assumed in this work match those in existing positron experiments and are low compared with those in electron experiments. Future positron experiments at higher densities will not exhibit the nonlinear diffusion treated here because they will be dominated by recombination and tunneling ionization by the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially limited ion acoustic drift soliton in electron-positron-ion magnetoplasma

Ion acoustic drift solitary wave with intermediate parametric range in both linear and nonlinear regimes has been studied in electron-positron-ion magnetoplasma. In the spatially limited region dispersion relation in the linear and Zakharov-Kuznetsov-type equation in the nonlinear regime are derived, respectively. Both equations show the coupling of electrostatic drift and ion acoustic waves. The stationary soliton solution for oblique drift solitary waves with the effect of positron concentration and temperature has been discussed analytically and graphically. The results are relevant for astrophysical observations and diagnostics of laboratory electron-positron-ion magnetoplasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modulation instability of low-frequency electrostatic ion waves in magnetized electron-positron-ion plasma

The nonlinear amplitude modulation of low-frequency electrostatic ion waves propagating in collisionless magnetized electron-positron-ion plasma are studied. The Krylov-Bogoliubov-Mitropolsky perturbation method is employed to derive the nonlinear Schroedinger equation. Modulation instability of both ion-acoustic and ion-cyclotronlike modes is examined. We found that the ion-acoustic mode, which propagates below the ion-cyclotron frequency, is stable if the strength of the external magnetic field is small. However, as the strength of the magnetic field increases, this mode becomes modulationally unstable for a range of wave numbers and angles of propagation. This range increases as the strength of the magnetic field and/or positron density increases. For the ion-cyclotronlike mode, which propagates above the ion-cyclotron frequency, a number of stability/instability regions appear in the (k{sub c},{theta}) plane even for a very small value of the magnetic field. It is found that, for both modes, critical wave number k{sub c} separating the stability and instability regions, shifts towards higher values as the density of the positron increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗