Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design and Construction of Prototype Dark Matter Detectors: ΔLepton Quark Studies (LQS)

The Lepton Quark Studies (LQS) group is engaged in searching for dark matter using the Dark Matter Time Projection Chamber (DMTPC) at the Waste Isolation Pilot Plant (WIPP) (Carlsbad, NM). DMTPC is a direction-sensitive dark matter detector designed to measure the recoil direction and energy deposited by fluorine nuclei recoiling from the interaction with incident WIMPs. In the past year, the major areas of progress have been: • to publish the first dark matter search results from a surface run of the DMTPC prototype detector, • to build and install the 10L prototype in the underground laboratory at WIPP which will house the 1 m 3 detector, and • to demonstrate charge and PMT readout of the TPC using prototype detectors, which allow triggering and z measurement to be used in the 1 m 3 detector under development.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Electrostatically-focused UV HPD for Liquid Xenon

Appropriate photodetectors are a major challenge for liquid xenon technology as proposed by the next generation of double beta decay, solar neutrino, and dark matter searches. The primary photon signal is tiny and in the hard ultraviolet, the installation is cryogenic, and the sensors themselves must not introduce background. Hybrid photodiodes (HPDs) provide an easy substitute for a conventional PMT with the added advantages of low radioactivity, better area coverage, and single photoelectron counting. A computer-controlled test setup capable of characterizing optical properties of ultraviolet photodetectors was installed. It was used to compare photomultiplier tubes, silicon photomultipliers, avalanche photodiodes, and a novel-design custom HPD developed by the DEP company under this proposal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Vernier Scans during RHIC Run-13 (pp at 255 GeV/beam)

At RHIC the collision rate per IP is measured by the Zero Degree Calorimeters (ZDC). Both, STAR and PHENIX, contain those detectors that are of identical design but are equipped with different Photo Multiplier Tubes (PMT) and operated with individually different HV setups and also slightly different read-out electronics. The collision rate, as measured by the ZDC, corresponds to the rate of mutual forward neutral particles above a variable threshold and within a certain coincidence window. Due to the differences in the detector electronics the two devices are calibrated individually every year by the use of vernier scans. During the RHIC polarized proton Run in 2013 a total of 6 vernier scans per experiment were performed. This note presents the data and summarizes the results, i.e. effective ZDC cross section and emittance measurements, from those scans.

43 PARTICLE ACCELERATORS↗

Development and Deployment of a Compact Eye-Safe Scanning Differential absorption Lidar (DIAL) for Spatial Mapping of Carbon Dioxide for Monitoring/Verification/Accounting at Geologic Sequestration Sites

A scanning differential absorption lidar (DIAL) instrument for monitoring carbon dioxide has been developed. The laser transmitter uses two tunable discrete mode laser diodes (DMLD) operating in the continuous wave (cw) mode with one locked to the online absorption wavelength and the other operating at the offline wavelength. Two in-line fiber optic switches are used to switch between online and offline operation. After the fiber optic switch, an acousto- optic modulator (AOM) is used to generate a pulse train used to injection seed an erbium doped fiber amplifier (EDFA) to produce eye-safe laser pulses with maximum pulse energies of 66 {micro}J, a pulse repetition frequency of 15 kHz, and an operating wavelength of 1.571 {micro}m. The DIAL receiver uses a 28 cm diameter Schmidt-Cassegrain telescope to collect that backscattered light, which is then monitored using a photo-multiplier tube (PMT) module operating in the photon counting mode. The DIAL instrument has been operated from a laboratory environment on the campus of Montana State University, at the Zero Emission Research Technology (ZERT) field site located in the agricultural research area on the western end of the Montana State University campus, and at the Big Sky Carbon Sequestration Partnership site located in north-central Montana. DIAL data has been collected and profiles have been validated using a co-located Licor LI-820 Gas Analyzer point sensor.

47 OTHER INSTRUMENTATION↗

Neutrino Physics with SNO+

SNO+ is a neutrino experiment with a broad physics program, the primary goal being a search for the phenomenon of neutrinoless double beta decay, a process possible only if the neutrino is its own antiparticle, or a "Majorana" fermion. Such a discovery would substantially alter our understanding of particle physics, including introducing the need for a non-Higgs mechanism for generating particle mass, and place constraints on the as-yet-unknown neutrino mass scale. SNO+ will also detect neutrinos from the solar core, furthering our understanding of the fusion cycles that power the sun, and antineutrinos produced inside the Earth (geoneutrinos), which will enable a better understanding of heat production beneath the Earth's surface. We will continually monitor for neutrinos from nearby supernovae, which, if detected, could allow us to better understand the role of neutrinos in stellar core collapse, and potentially to determine the unknown neutrino mass hierarchy. With such a broad physics program, SNO+ has great potential both to advance our understanding of neutrinos, and to use neutrinos to understand the formation and behavior of our Universe. This report describes a targeted plan of optical calibrations of the SNO+ detector, with the goal of measuring and monitoring the PMT optical response independently of liquid scintillator properties. To this end we describe the design, construction, and operation of a source of Cherenkov light for deployment in SNO+. Successful deployment in the initial light water phase is described, demonstrating the capabilities of this calibration mechanism. The results of this work form a critical input to the SNO+ detector model, directly impacting the sensitivity of all SNO+ physics results. Also described is significant work on detector commissioning, DAQ and operations, the implementation of calibration efforts in multiple physics analyses, involvement in all levels of analysis activities, and leadership in SNO+ science.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for heavy Majorana neutrinos in pp collisions at √s = 8 TeV with the CMS detector & photodetector and calorimeter R&D for particle colliders

This thesis contains both physics analysis and hardware studies. It consists of two primary sections: the results of a search for heavy Majorana mass neutrinos, using the event signature of same (like) sign charged electron pairs ($e^{\pm} e^{\pm}$ ) and two jets, and the results of studies to upgrade the Hadronic Forward (HF) and Hadronic Endcap (HE) subdetectors in the Compact Muon Solenoid (CMS) detector in response to the high intensity proton-proton collisions generated at the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN, Conseil Europ\'{e}en pour la Recherche Nucl\'{e}aire). In this search for Majorana mass neutrinos, same sign dielectron ($e^{\pm} e^{\pm}$) + dijet events in the final state have been considered as a signature for neutrino particles. The analyzed data corresponds to an integrated luminosity of 19.7 fb\textsuperscript{-1} of proton-proton collisions at a center of mass energy of $\sqrt{s} = 8 \text{TeV}$, collected using the CMS detector during the 2012 operation at the LHC. Monte Carlo simulations accounting for the theoretical expectations of the Standard Model (SM) and the detector limitations are used to prototype the experiment and to test proposed analysis steps. No excess of events is observed in the data beyond the expected SM background. Upper limits are set on the mixing element squared, $|{V}_{eN}|^{2}$, of the heavy Majorana neutrino with standard model neutrinos, as a function of Majorana neutrino mass for masses in the range of 40-500 $GeV/c^2$. The detector upgrade search comprises three sections of this thesis. The first section describes the test results of 1785 multianode Hamamatsu R7600U-200-M4 photomultiplier tubes (PMT) in numerous parameters such as gain, dark current, and timing characteristics, which provide insights on the expected performance of the upgraded CMS-HF detector. These PMTs replaced the previous single anode R7525 PMTs because the glass windows of previous PMTs are the source of Cherenkov radiation, which causes a background noise in the experiment. The second section reports characterization results of two types of PMTs in a novel operation mode for Secondary Emission (SE) Ionization Calorimetry, which is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The third section presents the test results of novel scintillating materials for CMS experiment in specific and future particle accelerators in general. These materials are Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), high efficiency mirror (HEM) and quartz plates with various organic and inorganic coating materials such as p-Terphenyl (pTp), Anthracene and Gallium-doped Zinc Oxide (ZnO:Ga). We have investigated them for radiation hardness, light yield, timing characteristics, and scintillation and transmission properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Evaluation of Bang-Time Measurements from a Multichannel, Triaxial, nTOF Diagnostic for MagLIF Experiments at the Z facility

Neutron bang times for a series of MagLIF (Magnetic Liner Inertial Fusion) experiments with D 2 -filled targets have been measured at the Z facility. The emitted neutrons were detected as current-mode pulses in a multichannel, neutron time-of-flight (nTOF) diagnostic with conventional, scintillator-photomultiplier-tube (PMT) detectors. In these experiments, the detectors were fielded at known, fixed distances L (690-2510 cm) from the target, and on three, non-coplanar (but convergent) lines-of-sight (LOS). The primary goal of this diagnostic was to estimate a fiducial time (bang time) relative to an externally generated time-base for synchronizing all the diagnostics in an experiment. Recorded arrival times (A7) of the pulses were characterized experimentally by three numerical methods: a first-moment estimate (centroid) and two nodal measures — Savitzky-Golay (SG) smoothing and a single point peak estimate of the raw data. These times were corrected for internal detector time delays (transit and impulse-response function) — an adjustment that linked the recorded ATs to the corresponding arrival of uncollided neutrons at each detector. The bang time was then estimated by linearly regressing the arrival times against the associated distances to the source; t bang (on the system timescale) was taken as the temporal intercept of the regression equation at distance L = 0. This article reports the analysis for a representative shot #2584 for which (a) the recorded ATs — even without detector corrections — agreed by method in each channel to within 1-2 ns; (b) internal corrections were each ~3 — 5 ns; and (c) a 95% uncertainty (confidence) interval for t bang in this shot was estimated at ±3 ns with 4 degrees of freedom. A secondary goal for this diagnostic was to check that the bang time measurements corresponded to neutrons emitted by the D(d,n) 3 He reaction in a thermalized DD plasma. According to the theoretical studies by Brysk, such neutrons should be emitted with an isotropic Gaussian distribution of mean kinetic energy $ \overline{E}$ of 2.449 MeV; this energy translates to a mean neutron speed $ \overline{u}$ of 2.160 cm/ns [D. H. Munro, Nuclear Fusion, 56(3) 036001 (2016)]. In the MagLIF series of shots there was no evidence of spatial asymmetry in the time-distance regressions, and it was possible to extract the mean neutron speed from the slope of these fits. In shot 2584 $ \overline{u}$ was estimated at 2.152 cm/ns ± 0.010 cm/ns [95 % confidence, 4 dof] and the mean kinetic energy $ \overline{E}$ (with relativistic corrections) was 2.431 MeV ± 0.022 MeV [95 % confidence, 4 dof] — results supporting the assumption that D-D neutrons were, in fact, measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Level 2 Milestone MRT 6218: Improve Nuclear Measurements on the NIF

This report documents the completion of the Inertial Confinement Fusion, Level 2 Milestone MRT 6218, “Improve Nuclear Measurements on the NIF.” The three completion criteria are, “1) Complete Operational qualification (OQ) of Pulse Dilation PMT on the Gas Cherenkov Detector in the Well DIM at NIF, 2) Measure highly resolved (temporal magnification >= 5x) gamma signals for Carbon (ablator) history, 3) Measure highly resolved (temporal magnification >= 5x) gamma signals for DT fusion reaction history.”

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MicroBooNE Detector Stability

The Micro Booster Neutrino Experiment (MicroBooNE) is designed to explore the lowenergy excess in the ν e event spectrum reported by the MiniBooNE experiment [1] and to measure ν-Ar cross sections in the 1 GeV energy range. The detector is a liquid argon time projection chamber with wire readout, supplemented with a light detection system based on photo-multiplier tubes (PMTs). The apparatus is located in the Booster Neutrino Beamline (BNB) at Fermilab and started collecting neutrino data in October 2015. This note presents a study of the stability of the MicroBooNE detector by measuring the average number of reconstructed tracks per event, the average number of reconstructed vertices per event, and the average number of multi-PMT coincidences (flashes) per event. These quantities are chosen since these are the most relevant to the ν µ charged-current inclusive analysis [2].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GCD: Current Performance / Issues [Slides]

LANL purchased a man instrument (pulse dilation PMT) from the Sydor Instruments, Inc. The company requests to get experimental data obtained using the instrument, for their record.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects of Neutrino Cross Section Measurements Using the NuMI off axis at ICARUS [Poster]

ICARUS, a Liquid Argon Time Projection Chamber, will serve as the Far Detector of the short-baseline neutrino program using the Booster beamline at Fermilab. It is 103 mrad off-axis of the NuMI beamline. Prospects for cross-section measurements and the status of the trigger system using the PMT system to collect electron and muon neutrinos from NuMI will be shown. Accurate neutrino cross-section measurements on argon are required for precise measurements of neutrino oscillation physics such as CP- violation and the ordering of the neutrino masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tile Detector with Wavelength Shifting Fiber Readout

At low beam intensity, ion chambers and the Digital Beam Imager are not able to produce a beam uniformity measurement. Plastic scintillator with PMT readout has been used to calibrate the beam in the past. The paper examines the use of scintillator tiles readout using wavelength shifting fibers and PMTs to create a low intensity device similar in function to the 256-pixel ion chamber for measuring the relative flux in 1x1 cm 2 regions over a 32 x 32 cm 2 area.

43 PARTICLE ACCELERATORS↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IER 480: TEX-Pu Benchmark (PU-MET-THERM-004) to Test Polyethylene and Lucite Thermal Scattering Laws [Slides]

This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff at 20°C. Accepted into 2023 version of the ICSBEP Handbook. Temperature had a large impact on reactivity of the critical configuration. Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to aid in data testing and benchmark adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing Neutrino Event Simulation through Overlays at the ICARUS Experiment on the Short-Baseline Neutrino Program

In the pursuit of precise neutrino event simulation, the ICARUS experiment within the Short-Baseline Neutrino (SBN) program at Fermilab uses an overlay technique to closely align simulations with experimental data. This technique consists of taking signals from data from each of the each of the three subsystems (TPC, PMT, CRT) and overlaying a simulated neutrino interaction onto the event. The overlay procedure includes superimposing simulated waveforms from neutrino interactions from both Time Projection Chambers (TPC) and Photomultiplier Tubes (PMTs) onto their respective data counterparts. Furthermore, the Cosmic Ray Tagger (CRT) hits from both data and simulations are combined to form the overlay event. By combining signals in this manner, we can obtain a data-driven modeling of cosmic backgrounds as well as the detector response enabling a more precise handling of noise sources when using neutrino simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗