Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Emissive probe diagnostics in low temperature plasma--effect of the space charge and variations of the electron saturation current

We report on the effect of over{approx}underestimation of the plasma potential by the strongly emitting probe technique in the low temperature plasma due to the effect of the space charge of the emitted electrons; experimental data are compared with theoretical model. Further we studied the electron saturation current variations at varying probe heating and we found them to be closely related to the probe wire contamination. The study was performed in two types of low temeperature argon plasma--weakly magnetized plasma of the cylindrical magnetron and the hollow cathode plasma jet showing different trends.

36 MATERIALS SCIENCE↗

Non-invasive in situ plasma monitoring of reactive gases using the floating harmonic method for inductively coupled plasma etching application

The floating harmonic method was developed for in situ plasma diagnostics of allowing real time measurement of electron temperature (T{sub e}) and ion flux (J{sub ion}) without contamination of the probe from surface modification by reactive species. In this study, this novel non-invasive diagnostic system was studied to characterize inductively coupled plasma of reactive gases monitoring T{sub e} and J{sub ion} for investigating the optimum plasma etching conditions and controlling of the real-time plasma surface reaction in the range of 200-900 W source power, 10-100 W bias power, and 3-15 mTorr chamber pressure, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic mass dependent electrostatic diagnostics of colliding laser plasma plumes

The behaviours of colliding laser plasma plumes (C{sub p}) compared with single plasma plumes (S{sub p}) are investigated for 14 different atomic mass targets. A Faraday cup, situated at the end of a drift tube (L = 0.99 m), is employed to record the time-of-flight (TOF) current traces for all elements and both plume configurations, for a fixed laser intensity of I{sub p} = 4.2 × 10{sup 10} W cm{sup −2} (F = 0.25 kJ cm{sup −2}). The ratio of the peak current from the C{sub p} relative to twice that from the S{sub p} is designated as the peak current ratio while the ratio of the integrated charge yield from the C{sub p} relative to twice that from the S{sub p} is designated as the charge yield ratio. Variation of the position of the Faraday cup within the drift tube (L = 0.33, 0.55, and 0.99 m) in conjunction with a lower laser fluence (F = 0.14 kJ cm{sup −2}) facilitated direct comparison of the changing TOF traces from both plasma configurations for the five lightest elements studied (C, Al, Si, Ti, and Mn). The results are discussed in the frame of laser plasma hydrodynamic modelling to approximate the critical recombination distance L{sub CR}. The dynamics of colliding laser plasma plumes and the atomic mass dependence trends observed are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-color interferometer for the study of laser filamentation triggered electric discharges in air

We present a space and time resolved interferometric plasma diagnostic for use on plasmas where neutral-bound electron contribution to the refractive index cannot be neglected. By recording simultaneously the plasma optical index at 532 and 1064 nm, we are able to extract independently the neutral and free electron density profiles. We report a phase resolution of 30 mrad, corresponding to a maximum resolution on the order of 4×10{sup 22} m{sup −3} for the electron density, and of 10{sup 24} m{sup −3} for the neutral density. The interferometer is demonstrated on centimeter-scale sparks triggered by laser filamentation in air with typical currents of a few tens of A.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and space resolved diagnostics for plasma thermal-chemical instability of fuel oxidation in nanosecond plasma discharges

Here, an instability in a nanosecond pulsed dielectric barrier discharge plasma occurring in methane–oxygen–argon mixtures is experimentally observed and measured by 1D time-resolved in situ electric field measurements. This instability, which seems to be created by the positive feedback between plasma kinetics and plasma-assisted low temperature fuel oxidation, is studied using electric field induced second harmonic generation and direct ICCD imaging. The rapid formation of streamers from an originally uniform discharge appears to be caused by the chemical kinetics of plasma-assisted low temperature methane oxidation, which may be resulting in a new type of plasma instability: a thermal-chemical instability. The results also revealed that the occurrence of this possible thermal-chemical instability in a reactive flow drastically changes the plasma properties by forming multiple secondary discharges and possibly leads to micron-sized non-uniform electric distributions. Single shot uncalibrated measurements of the electric field of the micron sized streamers appears to show much greater strengths than the average electric field. Furthermore, one-dimensional data analysis shows the positive feedback loop between the streamers and the low temperature plasma assisted oxidation chemistry in the plasma thermal-chemical instability. The present finding advances the understanding plasma instability growth and provides a new way to control plasma uniformity in plasma-assisted combustion and plasma fuel reforming.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a High-Speed Multichannel Data Acquisition System for Magnetic Diagnostics and Plasma Centroid Position Control in ISTTOK

In tokamak and other fusion devices, magnetic control is the main tool that allows to regulate the plasma current, position and shape; it is in charge of actuating the desired plasma current waveform, steering the plasma position to a given set point and maintain the plasma shape close to a prescribed plasma equilibrium. This work describes the application of several physics concepts and computational tools in order to obtain a novel optimal controller for the plasma centroid position, which has been implemented and tested in the real-time plasma control system at the ISTTOK tokamak. A key point for the development of the new control system was the installation of a recently upgraded hardware, that numerically integrates in real-time the magnetic probes signals.

poloidal field coils↗

Hot ion plasmas from the cloud of neutral gases surrounding the Space Shuttle

Large intensities of hot positive ions are observed out to distances of several hundred meters from the Space Shuttle with a plasma analyzer on a small free-flying satellite, the Plasma Diagnostics Package. This ion plasma is inferred to be generated by the charge exchange of ionospheric O+ ions with a large cloud of water molecules from the Space Shuttle. The measured ion density ranges from about 30 to 10,000 H2O+ ions/cu cm. A model for the water vapor cloud provides the basis for density estimates as high as 10 to the 9th H2O molecules/cu cm at a distance of 50 m from the Space Shuttle. Thus, the Space Shuttle possesses a substantial coorbiting atmosphere.

Paterson, W. R.↗

Laboratory Plasma Source as an MHD Model for Astrophysical Jets

The significance of the work described herein lies in the demonstration of Magnetized Coaxial Plasma Gun (MCG) devices like CPS-1 to produce energetic laboratory magneto-flows with embedded magnetic fields that can be used as a simulation tool to study flow interaction dynamic of jet flows, to demonstrate the magnetic acceleration and collimation of flows with primarily toroidal fields, and study cross field transport in turbulent accreting flows. Since plasma produced in MCG devices have magnetic topology and MHD flow regime similarity to stellar and extragalactic jets, we expect that careful investigation of these flows in the laboratory will reveal fundamental physical mechanisms influencing astrophysical flows. Discussion in the next section (sec.2) focuses on recent results describing collimation, leading flow surface interaction layers, and turbulent accretion. The primary objectives for a new three year effort would involve the development and deployment of novel electrostatic, magnetic, and visible plasma diagnostic techniques to measure plasma and flow parameters of the CPS-1 device in the flow chamber downstream of the plasma source to study, (1) mass ejection, morphology, and collimation and stability of energetic outflows, (2) the effects of external magnetization on collimation and stability, (3) the interaction of such flows with background neutral gas, the generation of visible emission in such interaction, and effect of neutral clouds on jet flow dynamics, and (4) the cross magnetic field transport of turbulent accreting flows. The applicability of existing laboratory plasma facilities to the study of stellar and extragalactic plasma should be exploited to elucidate underlying physical mechanisms that cannot be ascertained though astrophysical observation, and provide baseline to a wide variety of proposed models, MHD and otherwise. The work proposed herin represents a continued effort on a novel approach in relating laboratory experiments to astrophysical jet observation. There exists overwhelming similarity among these flows that has already produced some fascinating results and is expected to continue a high pay off in future flow similarity studies.

Mayo, Robert M.↗

Experimental study of the asymmetric charge transfer reaction between Ar{sup +} ions and Fe atoms

We investigate the Ar{sup +}-Fe asymmetric charge transfer (ACT) reaction using a combination of plasma diagnostics methods and a kinetic model of the afterglow plasma, which allow monitoring of the temporal evolution of the densities of different species. The iron vapor is created inside a discharge cell by cathode sputtering; its density is measured by atomic absorption spectroscopy. The rate coefficient of the reaction is evaluated from the emission intensity decay of Fe{sup +}* lines pumped by the ACT process in the He-Ar-Fe and Ar-Fe afterglow plasmas. The measurements yield a rate coefficient k= 7.6( {+-} 3.0) x 10{sup -9} cm{sup 3} s{sup -1} at T = 300 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can we estimate plasma density in ICP driver through electrical parameters in RF circuit?

To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveance condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.

43 PARTICLE ACCELERATORS↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics for first plasma and development plan on KSTAR

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of maximum likelihood methods to laser Thomson scattering measurements of low density plasmas

Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. The key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New focusing multilayer structures for X-ray plasma spectroscopy

New focusing short-period multilayer structures are developed which opens up wide possibilities for X-ray and VUV spectroscopy. Multilayer structures are deposited on a flat surface of a mica crystal which is then bent to a small-radius cylinder. The use of this structure in a von Hamos spectrometer for X-ray laser plasma diagnostics is demonstrated. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Etching characteristics and mechanism of indium tin oxide films in an inductively coupled HBr/Ar plasma

The investigations of etch characteristics and mechanisms for indium tin oxide (In{sub 2}O{sub 3}){sub 0.9}:(SnO{sub 2}){sub 0.1} (ITO) thin films using HBr/Ar inductively coupled plasma were carried out. The ITO etch rate was measured in the range of 0%-100% Ar in the HBr/Ar mixture at fixed gas pressure (6 mTorr), input power (700 W), and bias power (200 W). Plasma parameters and composition were examined with a combination of plasma diagnostics by double Langmuir probe and global (zero-dimensional) plasma model. It was found that the ITO etch rate follows the behavior of Br atom flux but contradicts with that for H atoms and positive ions. This suggests that the ITO etch process is not limited by the ion-surface interaction kinetics and appears in the reaction-rate-limited etch regime with the Br atoms as the main chemically active species.

36 MATERIALS SCIENCE↗

Etch mechanism of In{sub 2}O{sub 3} and SnO{sub 2} thin films in HBr-based inductively coupled plasmas

The investigations of etch characteristics and mechanisms for both In{sub 2}O{sub 3} and SnO{sub 2} thin films in the HBr-based inductively coupled plasmas were carried out. The etch rates were measured as functions of gas mixing ratio (0%-100% Ar), input power (400-700 W), and gas pressure (4-10 mTorr) at fixed bias power (200 W) and gas flow rate [40 SCCM (SCCM denotes cubic centimeter per minute at STP)]. Plasma parameters and composition were determined using a combination of plasma diagnostics by double Langmuir probe and global (zero-dimensional) plasma model. The correlations between the behaviors of etch rates and fluxes of plasma active species allow one to infer both In{sub 2}O{sub 3} and SnO{sub 2} etch mechanisms as the transitional regime of ion-assisted chemical reaction, which is controlled by neutral and charged fluxes together.

36 MATERIALS SCIENCE↗