Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatially enhanced electric field induced second harmonic (SEEFISH) generation for measurements of electric field distributions in high-pressure plasmas

Abstract The spatial resolution of the ps electric field induced second harmonic (EFISH) generation has been enhanced by using non-collinear pump laser beam arrangements. The pump laser beam (1064 nm, nominal pulse duration 150 ps, pulse energy 20–40 mJ) is separated into two coaxial or crossing beams, overlapping only near the focal point. The spatially enhanced EFISH (SEEFISH) signal is generated over a shorter beam overlap region compared to the collinear beam arrangement. Blocking of either of the two beams results in a complete suppression of the signal. The signal is spatially isolated from the ‘conventional’ EFISH signal and measured by a photomultiplier detector. Measurements of a known Laplacian field generated between two parallel cylinder electrodes in ambient air shows that SEEFISH improves the spatial resolution of the measurements by up to a factor of 2, such that the measurement results agree with the Laplacian field distribution. The spatial resolution is improved further by reducing the focal distance of the lens. The magnitude of the SEEFISH signal is significantly lower compared to that of the single-beam EFISH and decreases rapidly as the beam crossing angle is increased, due to the phase mismatch. This approach has a significant potential for measurements of electric field distributions in high-pressure plasmas, with an additional benefit of removing the stray second harmonic signal from the optical access windows.

Physics↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast response, optical radiance measurements of low intensity impurity emission in WEST plasmas with staggered wavelength filters

Fast response acquisition of atomic line emission through the use of a filterscope has been implemented on the WEST tokamak at multiple poloidal locations. Filterscopes consist of a fiber-optic-based transmission from the tokamak to specifically engineered optical bandpasses and photomultiplier tubes (PMT) that collect the emission intensity to measure a radiance, L [W/cm2/str], over the specified bandpass. This diagnostic records plasma-wall interaction (PWI) properties (e.g. impurity emission and recycling of main fuel ions) up to a max acquisition rate of 100 kHz. These PMT radiometric measurements are calibrated into a line-normalized radiance, LN [photons/sec/cm2/str], similar to traditional spectrometers, which can later be converted to a particle flux. Low intensity emission peaks are difficult to quantify due to often comparable continuum levels, thus a secondary filter shifted to a judiciously-selected, line-free region (~1 nm away) allows for background subtraction. The system currently installed on WEST targets tungsten (W) gross sputtering specifically by monitoring, with a filter pair, the spectral region near the neutral W line emission (W I 400.9 nm). The line and background filters of the pair are centered at 400.6 nm and 403.1 nm, respectively. Through a set beam splitters on each sight line, the filter pair are measuring from the same location. The two L signals near W I are then subtracted from each other yielding only the W I LN. W I LN data from a recent WEST experimental campaign is presented and compared with plasma parameters and traditional spectrometer measurements of W I line emission to demonstrate the capabilities of this staggered-filter filterscope method. Specifically, the choice of WEST-specific bandpass curves for the W I LN will be illustrated based on this latter comparison.

Neff, Anton↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

Performance of PMTs for the JSNS 2 experiment

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate γ-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS 2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS 2 did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS 2 experiment, and 120 PMTs were installed in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗