Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOELECTRIC EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Go Pink! The Effect of Secondary Quanta on Detective Quantum Efficiency

Photons are never directly observable. Consequently, we often use photoelectric detectors (eg CCDs) to record associated photoelectrons statistically. Nonetheless, it is an implicit goal of radiographic detector designers to achieve the maximum possible detector efficiency1. In part the desire for ever higher efficiency has been due to the fact that detectors are far less expensive than associated accelerator facilities (e.g. DARHT and PHERMEX2). In addition, higher efficiency detectors often have better spatial resolution. Consequently, the optimization of the detector, not the accelerator, is the system component with the highest leverage per dollar. In recent years, imaging scientists have adopted the so-called Detective Quantum Efficiency, or DQE as a summary measure of detector performance. Unfortunately, owing to the complex nature of the trade-space associated with detector components, and the natural desire for simplicity and low(er) cost, there has been a recent trend in Los Alamos to focus only on the zerofrequency efficiency, or DQE(0), when designing such systems. This narrow focus leads to system designs that neglect or even ignore the importance of high-spatial-frequency image components. In this paper we demonstrate the significant negative impact of these design choices on the Noise Power Spectrum1 (NPS) and recommend a more holistic approach to detector design. Here we present a statistical argument which indicates that a very large number (>20) of secondary quanta (typically visible light and/or recorded photo-electrons) are needed to take maximum advantage of the primary quanta (typically x-rays or protons) which are available to form an image. Since secondary particles come in bursts, they are not independent. In short, we want to maximize the pink nature of detector noise at DARHT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photocurrent Enhancement Induced By Interface Modifications Due To Low Dose Electron Irradiation Of Amorphous/Crystalline Silicon Heterojunctions

A series of n-type amorphous silicon/p-type crystalline silicon solar cells has been exposed to different fluences of 1 MeV electrons. For intermediate fluences up to 1.10{sup 13} electrons/cm{sup 2}, an enhancement of the spectral response at shorter wavelengths and a increase of the short circuit current has been observed, while for higher fluences the usual device degradation due to the decrease of the charge carrier diffusion length in the crystalline silicon base after irradiation has been found.

36 MATERIALS SCIENCE↗

System-independent characterization of materials using dual-energy computed tomography

In this study, we present a new decomposition approach for dual-energy computed tomography (DECT) called SIRZ that provides precise and accurate material description, independent of the scanner, over diagnostic energy ranges (30 to 200 keV). System independence is achieved by explicitly including a scanner-specific spectral description in the decomposition method, and a new X-ray-relevant feature space. The feature space consists of electron density, ρ e , and a new effective atomic number, Z e , which is based on published X-ray cross sections. Reference materials are used in conjunction with the system spectral response so that additional beam-hardening correction is not necessary. The technique is tested against other methods on DECT data of known specimens scanned by diverse spectra and systems. Uncertainties in accuracy and precision are less than 3% and 2% respectively for the (ρ e , Z e ) results compared to prior methods that are inaccurate and imprecise (over 9%).

42 ENGINEERING↗

Effect of cadmium-selenide quantum dots on the conductivity and photoconductivity of nanocrystalline indium oxide

The effect of cadmium-selenide quantum dots addition on the electrical and photoelectric properties of nanocrystalline indium oxide with nanocrystal dimensions in the range from 7 to 40 nm is studied. By impedance spectroscopy, it is shown that the addition of quantum dots substantially influences the resistance of interfaces between In{sub 2}O{sub 3} crystals. A change in the character of the photoconductivity spectrum of In{sub 2}O{sub 3} upon the addition of CdSe quantum dots is detected, and it is established that this change depends on the In{sub 2}O{sub 3}-nanocrystal dimensions. An energy band diagram is proposed to explain the observed change in the photoconductivity spectrum of In{sub 2}O{sub 3} upon the addition of CdSe quantum dots.

36 MATERIALS SCIENCE↗

Gamma-ray lines from type I supernovae

Analytic calculations are made of the time-dependent fluxes, shapes, median energies, and effective widths of the gamma-ray lines expected from the decay of nucleosynthetic Ni-56, Co-56, Fe-56, and Co-57 in current models of type I SNe. The attenuation and distortion of the line shapes due to Compton scattering and photoelectric absorption in the SN ejecta, line broadening from the expansion, and further distortion by the lookback effect from the differential light-travel time across the SN and by special relativistic effects are all taken into account. It is shown that several gamma-ray lines from such SNe should be measurable by detectors on the Gamma Ray Observatory and by the high-resolution spectrometer on the proposed Nuclear Astrophysics Explorer. The most intense and most detectable lines are the 0.847 and 1.238 MeV lines from Co-56 decay. Five other Co-56 decay lines, as well as the 0.158 MeV line from Ni-56 decay, should also be measurable. The models which can be tested by such observations are pointed out.

Chan, Kai Wing↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

Electrical Properties of Indium-Oxide Thin Films Produced by Plasma-Enhanced Reactive Thermal Evaporation

The structure and electrical properties of transparent indium-oxide thin films produced by plasma-enhanced reactive thermal evaporation at different substrate temperatures are studied. It is found that the films have a grained structure. An increase in the substrate temperature yields a considerable increase in the conductivity of the films and a decrease in the photoconductivity-relaxation time. An interpretation of the effect of the substrate temperature on the observed changes in the electrical and photoelectric properties of the indium-oxide films under study is proposed.

36 MATERIALS SCIENCE↗

Photon-dominated regions around cool stars: The effects of the color temperature of the radiation field

We have investigated the influence of the color temperature of the illuminating radiation field on the chemical and thermal structure of photon-dominated regions (PDRs). We present the results of a study of the photoelectric efficiency of heating by large molecules such as polycyclic aromatic hydrocarbons (PAHs) and very small grains for radiation fields characterized by different effective temperatures. We show that the efficiency for cooler (T(sub eff) approximately = 6000-10,000 K) stars is at most an order of magnitude smaller than that for hotter (T(sub eff) approximately = 20,000-30,000 K) stars. While cooler radiation fields result in less ultraviolet photons capable of heating, the efficiency per absorbed photon is higher, because the grains become less positively charged. We also present detailed calculations of the chemistry and thermal balance for generic PDRs (n(sub 0) approximately = 10(exp 3), G(sub 0) approximately = 10(exp 3)). For cooler radiation fields, the H/H2 and C(+)/C/CO transition layers shift toward the surface of the PDR, because fewer photons are available to photodissociate H2 and CO and to ionize C. The dominant cooling lines are the (C II) 158 micron and the (O I) 63 micron lines for the hotter radiation fields, but cooling by CO becomes dominant for a color temperature of 6000 K or lower. The (C II)/CO and (O I)/CO ratios are found to be very good diagnostics for the color temperature of the radiation field.

Spaans, Marco↗

The influence of surface impurities on photoelectric currents driven by intense soft x rays

In an x-ray driven cavity experiment, an intense flux of soft x rays on the emitting surface produces significant emission of photoelectrons having several kiloelectronvolts of kinetic energy. At the same time, rapid heating of the emitting surface occurs, resulting in the release of adsorbed surface impurities and subsequent formation of an impurity plasma. This numerical study explores a simple model for the photoelectric currents and the impurity plasma. In this work, attention is given to the effect of varying the composition of the impurity plasma. The presence of protons or hydrogen molecular ions leads to a substantially enhanced cavity current, while heavier plasma ions are seen to have a limited effect on the cavity current due to their lower mobility. Additionally, it is demonstrated that an additional peak in the current waveform can appear due to the impurity plasma. A correlation between the impurity plasma composition and the timing of this peak is elucidated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Siloxane-functional small molecule acceptor for high-performance organic solar cells with 16.6% efficiency

As one of the simple but most effective molecular design strategies, side-chain engineering has been widely employed to modify the photoelectric properties of active layer materials for boosting the photovoltaic performance of organic solar cells (OSCs). In this work, a functionalized small molecule acceptor (SMA) named BTSi-4F with a bulky siloxane-terminated solubilizing group as side-chains, derived from a classical SMA of Y6, was designed and synthesized. The results demonstrate that the introduction of siloxane-functional terminated groups into SMA not only affects the optical absorption and molecular energy levels, but also regulates the miscibility between the polymer donor and SMA. Compared to the original Y6, BTSi-4F exhibits a better solubility, upshifted lowest unoccupied molecular orbital (LUMO) energy level, more ordered molecular packing, and higher electron-mobility. Matched with a wide bandgap polymer donor PM6, the chlorobenzene-processed OSCs based on PM6:BTSi-4F achieved a superior power conversion efficiency (PCE) of 16.6% with both high open-circuit voltage (V oc ) of 0.90 V and high fill factor (FF) of 0.77, while the devices based on PM6:Y6 obtained a much lower PCE of 13.0% with a V oc of 0.81 V and FF of 0.69 under the same conditions. This work offers a promising molecular design strategy of siloxane-terminated side chain engineering to develop high-performance SMAs for efficient OSCs.

14 SOLAR ENERGY↗

eXTP: Enhanced X-Ray Timing and Polarimetry Mission

eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary goals are the determination of the equation of state of matter at supra-nuclear density, the measurement of QED effects in highly magnetized star, and the study of accretion in the strong-field regime of gravity. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of approx. 0.9 m(exp. 2) and 0.6 m(exp. 2) at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering less than 180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of approx. 3.4 m(exp. 2), between 6 and 10 keV, and spectral resolution better than 250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm(exp. 2) at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees field of view. The eXTP international consortium includes major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.

X-ray astronomy↗

Background studies in gas ionizing x ray detectors

The background response of a gas ionizing proportional x ray detector is estimated by solving the one dimensional photon transport equation for two regions using Monte Carlo techniques. The solution was effected using the SSL VAX 780 and the CRAY XMP computers at Marshall Space Flight Center. The isotropic photon energy spectrum encompassing the range from 1 to 1000 KeV incident onto the first region, the shield, is taken so as to represent the measured spectrum at an altitude of 3 mb over Palastine, Texas. The differential energy spectrum deposited in the gas region, xenon, over the range of 0 to 100 KeV is written to an output file. In addition, the photon flux emerging from the shield region, tin, over the range of 1 to 1000 KeV is also tabulated and written to a separate file. Published tabular cross sections for photoelectric, elastic and inelastic Compton scattering as well as the total absorption coefficient are used. Histories of each incident photon as well as secondary photons from Compton and photoelectric interactions are followed until the photon either is absorbed or exits from the regions under consideration. The effect of shielding thickness upon the energy spectrum deposited in the xenon region for this background spectrum incident upon the tin shield was studied.

Eldridge, Hudson B.↗

Disentangling Planets from Photoelectric Instability in Gas-rich Optically Thin Dusty Disks

Structures in circumstellar disks such as gaps and rings are often attributed to planets. This connection has been difficult to show unequivocally, as other processes may also produce these features. In particular, a photoelectric instability (PEI) has been proposed, operating in gas-rich optically thin disks, that generates structures predicted by planet–disk interactions. We examine the question of how to disentangle the planetary effects on disk structure from the effects of the PEI. We use the Pencil Code to perform 2D global hydrodynamical models of the dynamics of gas and dust in a thin disk with and without planetary perturbers. Photoelectric heating is modeled with an equation of state where pressure is proportional to dust surface density. The drag force on grains and its backreaction on the gas are included. Analyzing the situation without PEI, we find that gas–dust interactions alter the shape of the planetary gap from the dust-free case when the local dust-to-gas ratio ε approaches unity. This result also applies to primordial disks, because dust drifting inward accumulates at the edge of the planetary gap, and any initial dust-to-gas ratio eventually achieves ε = 1 if the dust reservoir is sufficient. We find a result particular to high dust-to-gas ratio disks as well: as dust drifts inward, the dust front becomes a sharp transition, and the backreaction triggers the Rossby wave instability. When PEI is included, we find that it obscures structures induced by planets unless the planet's mass is sufficiently large to carve a noticeable gap. Specifically, the instability generates arcs and rings of regular spacing: a planet is discernible when it carves a dust gap wider than the wavelength of the PEI.

Areli Castrejon↗

Quantification of differences in the effective atomic numbers of healthy and cancerous tissues: A discussion in the context of diagnostics and dosimetry

Purpose: There are a range of genetic and nongenetic factors influencing the elemental composition of different human tissues. The elemental composition of cancerous tissues frequently differs from healthy tissue of the same organ, particularly in high-Z trace element concentrations. For this reason, one could suggest that this may be exploited in diagnostics and perhaps even influence dosimetry. Methods: In this work, for the first time, effective atomic numbers are computed for common cancerous and healthy tissues using a robust, energy-dependent approach between 10 keV and 100 MeV. These are then quantitatively compared within the context of diagnostics and dosimetry. Results: Differences between effective atomic numbers of healthy and diseased tissues are found to be typically less than 10%. Fibrotic tissues and calcifications of the breast exhibit substantial (tens to hundreds of percent) differences to healthy tissue. Expectedly, differences are most pronounced in the photoelectric regime and consequently most relevant for kV imaging/therapy and radionuclides with prominent low-energy peaks. Cancerous tissue of the testes and stomach have lower effective atomic numbers than corresponding healthy tissues, while diseased tissues of the other organ sites typically have higher values. Conclusions: As dose calculation approaches improve in accuracy, there may be an argument for the explicit inclusion of pathologies. This is more the case for breast, penile, prostate, nasopharyngeal, and stomach cancer, less so for testicular and kidney cancer. The calculated data suggest dual-energy computed tomography could potentially improve lesion identification in the aforementioned organs (with the exception of testicular cancer), with most import in breast imaging. Ultimately, however, the differences are very small. It is likely that the assumption of a generic 'tissue ramp' in planning will be sufficient for the foreseeable future, and that the Z differences do not notably aid lesion detection beyond that already facilitated by differences in mass density.

60 APPLIED LIFE SCIENCES↗

A Pennsylvania State University/General Electric Get Away Special (GAS) experiment

We describe four student-designed experiments by the Pennsylvania State University, which are planned for a GAS canister. The four experiments will measure: the effects of radiation on semiconductors; orbital debris impacts; the Space Shuttle's magnetic field; and the photoelectric yield of several different materials. These experiments are the result of the efforts of more than one hundred students.

Evanisko, George↗