Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Entanglement swapping systems toward a quantum internet

We demonstrate conditional entanglement swapping, i.e. teleportation of entanglement, between time-bin qubits at the telecommunication wavelength of 1536.4 nm with high fidelity of 87%. Our system is deployable, utilizing modular, off-the-shelf, fiber-coupled, and electrically controlled components such as electro-optic modulators. It leverages the precise timing resolution of superconducting nanowire detectors, which are controlled and read out via a custom developed graphical user interface. The swapping process is described, interpreted, and guided using characteristic function-based analytical modeling that accounts for realistic imperfections. Our system supports quantum networking protocols, including source-independent quantum key distribution, with an estimated secret key rate of approximately 0.5 bits per sifted bit.

Davis, Samantha I. [Caltech] (ORCID:00000001999481↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, an experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the $z$ dimension.

Rao, Shardul↗

Modeling and Proof-of-Concept of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a pilot experiment realization of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD coaxial reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the axial dimension. Additionally, it is demonstrated that the blackbody photon source used in this calibration must be at a temperature of at least $\SI{15}{\kelvin}$ to $\SI{40}{\kelvin}$, depending on the sensitivity of the SNSPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Heralded Multiplexed High-Efficiency Cascaded Source of Dual-Rail Entangled Photon Pairs Using Spontaneous Parametric Down-Conversion

Deterministic sources of high-fidelity entangled qubit pairs encoded in the dual-rail photonic basis, i.e., presence of a single photon in one of two orthogonal modes, are a key enabling technology of many applications of quantum information processing, including high-rate, high-fidelity quantum communications over long distances. The most popular and mature sources of such photonic entanglement, e.g., those that leverage spontaneous parametric down-conversion (SPDC) or spontaneous four-wave mixing, generate an entangled (so-called continuous-variable) quantum state that contains contributions from high-order photon terms that lie outside the span of the dual-rail basis, which is detrimental to most applications. One often uses low pump power to mitigate the effects of those high-order terms. However, that reduces the pair generation rate, and the source becomes inherently probabilistic. We investigate a cascaded source that performs a linear-optical entanglement swap between two SPDC sources, to generate a heralded photonic entangled state that has a higher fidelity (to the ideal Bell state) compared to a free-running SPDC source. Furthermore, with the Bell swap providing a heralding trigger, we show how to build a multiplexed source, which despite reasonable switching losses and detector loss and noise, yields a fidelity versus success probability trade-off of a high-efficiency source of high-fidelity dual-rail photonic entanglement. We find, however, that there is a threshold of 1.5 dB of loss per switch, beyond which multiplexing hurts the fidelity versus success probability trade-off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of radiation tolerance in optical cements

We study the effect ionizing radiation has on light transmission in the wavelength range 190–1100 nm for a number of optically clear epoxies. We find that the transmittance of traditional, commercially available, optical epoxies show significant degradation for exposures of 1×10 12 MIPs/cm 2 . Degradation of light transmission progresses from the shortest wavelengths at low doses to longer wavelengths as the dose increases. In epoxy joints that are 0.1 mm thick, we observe that more than 5% of the light is lost for wavelengths less than 400 nm for traditional optical epoxies. Our studies have identified an optically clear epoxy that shows little degradation for radiation exposures up to 5.9× 10 14 MIPs/cm 2 (≈ 220 kGy).

Radiation-hard detectors↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

The Phase-2 Upgrade of the CMS Data Acquisition

The High Luminosity LHC (HL-LHC) will start operating in 2027 after the third Long Shutdown (LS3), and is designed to provide an ultimate instantaneous luminosity of 7:5 × 10$^{34}$ cm$^{-2}$ s$^{-1}$, at the price of extreme pileup of up to 200 interactions per crossing. The number of overlapping interactions in HL-LHC collisions, their density, and the resulting intense radiation environment, warrant an almost complete upgrade of the CMS detector. The upgraded CMS detector will be read out by approximately fifty thousand highspeed front-end optical links at an unprecedented data rate of up to 80 Tb/s, for an average expected total event size of approximately 8 - 10 MB. Following the present established design, the CMS trigger and data acquisition system will continue to feature two trigger levels, with only one synchronous hardware-based Level-1 Trigger (L1), consisting of custom electronic boards and operating on dedicated data streams, and a second level, the High Level Trigger (HLT), using software algorithms running asynchronously on standard processors and making use of the full detector data to select events for offline storage and analysis. The upgraded CMS data acquisition system will collect data fragments for Level-1 accepted events from the detector back-end modules at a rate up to 750 kHz, aggregate fragments corresponding to individual Level- 1 accepts into events, and distribute them to the HLT processors where they will be filtered further. Events accepted by the HLT will be stored permanently at a rate of up to 7.5 kHz. This paper describes the baseline design of the DAQ and HLT systems for the Phase-2 of CMS.

Badaro, Gilbert↗

Impact of dopant-induced band tails on optical spectra, charge carrier transport, and dynamics in single-crystal CdTe

Abstract Cadmium telluride (CdTe) semiconductors are used in thin-film photovoltaics, detectors, and other optoelectronic applications. For all technologies, higher efficiency and sensitivity are achieved with reduced charge carrier recombination. In this study, we use state-of-the-art CdTe single crystals and electro-optical measurements to develop a detailed understanding of recombination rate dependence on excitation and temperature in CdTe. We study recombination and carrier dynamics in high-resistivity (undoped) and arsenic (As)-doped CdTe by employing absorption, the Hall effect, time-resolved photoluminescence, and pump-probe in the 80–600 K temperature range. We report extraordinarily long lifetimes (30 µs) at low temperatures in bulk undoped CdTe. Temperature dependencies of carrier density and mobility reveal ionization of the main acceptors and donors as well as dominant scattering by ionized impurities. We also distinguish different recombination defects. In particular, shallow As Te and deep V Cd −As Cd acceptors were responsible for p-type conductivity. AX donors were responsible for electron capture, while nonradiative recombination centers (V Cd −As Te , As 2 precipitates), and native defects (V Cd −Te Cd ) were found to be dominant in p-type and n-type CdTe, respectively. Bimolecular and surface recombination rate temperature dependencies were also revealed, with bimolecular coefficient T −3/2 temperature dependence and 170 meV effective surface barrier, leading to an increase in surface recombination velocity at high temperatures and excitations. The results of this study allowed us to conclude that enhanced crucible rotation growth of As-doped CdTe is advantageous to As activation, leading to longer lifetimes and larger mobilities and open-circuit voltages due to lower absorption and trapping.

36 MATERIALS SCIENCE↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analog optical signal transmission for HEP experiments

A critical element in all high-energy physics experiments is the signal transmission from the active elements to the data acquisition system. It is especially challenging in large volume detectors based on noble liquids that are extensively being used for dark matter and neutrino detection.The topic of this contribution is the optical signal transmission of the signals acquired with silicon photomultipliers, which is able to satisfy many stringent experimental requirements. It is RF-noise immune and operates in cryogenic liquids and in high-electric fields.This transmission system is based on commercially available electronics components and customized Fabry-Perot laser diodes.I will talk about encountered challenges, breakthrough, and advances from the original concept of this system up to final validation tests, demonstrating progressive developments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Hierarchical Phased-Array Antennas Coupled to Al KIDs: A Scalable Architecture for Multi-band Millimeter/Submillimeter Focal Planes

We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher-frequency bands (190–365 GHz), and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest frequency band (125–175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.

47 OTHER INSTRUMENTATION↗