Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Reliability Analysis in the Presence of Aleatory Uncertainty

This paper proposes a method for modeling a system’s response using data. In contrast to approaches that identify a limit state function, we focus on the case in which not all uncertain parameters affecting the response are observable and the measured response is corrupted by noise. To this end, the system response is not characterized by a limit state function but instead by a Random Predictor Model (RPM) having a nonparametric structure. Consequently, the resulting failure probability is not a scalar but a random variable. This variable accounts for the aleatory contributions of the model-form uncertainty and the measurement noise into the response. Furthermore, we propose a framework that enables trading off the predicted range of failure probabilities resulting from such an analysis with a measure of risk. In this context, risk is the percentage of all predicted outcomes the analyst is willing to ignore. The reliability analysis of an aeroelastic structure subject to flutter is used to illustrate the ideas proposed.

Crespo, L. G.↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

Improved Flaw Detection and Characterization with Difference Thermography

Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.

Winfree, William P.↗

Noise in state of the art clocks and their impact for fundamental physics

In this paper a review of the use of advanced atomic clocks in testing the fundamental physical laws will be presented. Noise sources of clocks will be discussed, together with an outline their characterization based on current models. The paper will conclude with a discussion of recent attempts to reduce the fundamental, as well as technical noise in atomic clocks.

noise state-of-the-art clocks fundamental physics↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

Previous characterization of scan-related low-frequency noise was extended and refined through detailed analysis of shutter calibration data on CCT-ADDS tapes and reflective-band data from nighttime acquisitions. A recommended correction procedure was identified that uses calibration shutter data both as a diagnostic and to obtain correction values. Through comparison of coincident TM and MSS data, illustrations of the added information content of TM data for agricultural applications were developed. The capability of improved spatial resolution to better define boundaries and to resolve spatial details is shown. Spectral analysis of tasseled-cap transformations of TM and MSS data shows high correlation between greenness features, greater signal range for TM, and indications that a subset of TM bands could accurately simulate MSS data, if required.

Malila, W. A.↗

Two AFC Loops For Low CNR And High Dynamics

Two alternative digital automatic-frequency-control (AFC) loops proposed to acquire (or reacquire) and track frequency of received carrier radio signal. Intended for use where carrier-to-noise ratios (CNR's) low and carrier frequency characterized by high Doppler shift and Doppler rate because of high relative speed and acceleration, respectively, between transmitter and receiver. Either AFC loops used in place of phase-locked loop. New loop concepts integrate ideas from classical spectrum-estimation, digital-phase-locked-loop, and Kalman-Filter theories.

Hinedi, Sami M.↗

Interstellar detection of the intersystem line Si II lambda 2335 toward zeta Ophiuchi

We report on the detection of the weak intersystem transistion of Si II lambda 2335 A in the sight line toward zeta Oph using the Ech-B mode (3.5 km/s resolution) of the Goddard High Resolution Spectrograph. The high-quality spectrum is characterized by an empirically measured signal-to-noise of 450, in excellent agreement with that expected from photon-statistics. The measured equivalent width of the Si II line is W(sub lambda) = 0.48 +/- 0.12 mA. Using the new experimental f-value of Calamai, Smith, and Bergeson, we find a Si II column density of 2.34 (+/- 0.58) x 10(exp 15) atoms/sq cm and (Si/H)(sub zeta Oph) = 1.78 (+/- 0.44) x 10(exp -6) for the principal absorbing component(s) at v(sub sun) approx. = -15 km/s. Analysis of the Si II lambda 1808 absorption over the same velocity range using the new experimental f-value of Bergeson & Lawler yields a column density (corrected for saturation) that is consistent within the weak line errors and confirms the relative accuracies of these new f-values. Furthermore, these results indicate that accurate abundances can now be derived for Si II, particularly from the weak Si II lambda 2335 A since it is free of saturation effects. For the zeta Oph v(sub sun) approx. = -15 km/s component(s), we find that greater than 95% of the available cosmic abundance (i.e. the 1989 meteoritic abundances of Anders & Grevesse) of Mg, Fe, and Si is 'missing' from the gas phase and is presumably locked up in the dust. These elements are present in the dust grains in ratios of Fe/Si approximately equals 0.9 and Mg/Si approximately equals 1.1, consistent with the ratio of their cosmic abundances. These ratios are in sharp contrast to more diffuse clouds like those seen toward the high-latitude halo star HD 93521 where in the dust Fe/Si approximately equals 1.8 and Mg/Si approximately equals 2.1.

Cardelli, Jason A.↗

Performance of Small Pore Microchannel Plates

Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

Siegmund, O. H. W.↗

Characterization of Photoreceivers for LISA

LISA will use quadrant photo receivers as front-end devices for the phase meter measuring the motion of drag-free test masses in both angular orientation and separation. We have set up a laboratory testbed for the characterization of photo receivers. Some of the limiting noise sources have been identified and their contribution has been either measured or determined from the measured data. We have built a photo receiver with a 0.5 mm diameter quadrant photodiode with an equivalent input noise of better than 1.8 pA/(square root of)Hz below 20 MHz and a 3 dB bandwidth of 34 MHz.

Cervantes, F. Guzman↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that make the SXS a powerful x-ray spectrometer also make it sensitive to the entire electromagnetic band. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10(exp -18) W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs are addressed by a series of five thin-film radiation blocking filters that block long-wavelength radiation while minimizing x-ray attenuation. The SXS aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three warmer filters also were equipped with thermometers and heaters for decontamination.

microcalorimeter↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

Georgiev, Georgi T.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

Georgiev, Georgi T.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

BRDF↗

Characterization of the Reverberation Chamber at the NASA Langley Structural Acoustics Loads and Transmission (SALT) Facility

In 2011 the noise generating capabilities in the reverberation chamber of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center were enhanced with two fiberglass reinforced polyester resin exponential horns, each coupled to Wyle Acoustic Source WAS-3000 airstream modulators. This report describes the characterization of the reverberation chamber in terms of the background noise, diffusivity, sound pressure levels, the reverberation times and the related overall acoustic absorption in the empty chamber and with the acoustic horn(s) installed. The frequency range of interest includes the 80 Hz to 8000 Hz one-third octave bands. Reverberation time and sound pressure level measurements were conducted and standard deviations from the mean were computed. It was concluded that a diffuse field could be produced above the Schroeder frequency in the 400 Hz one-third octave band and higher for all applications. This frequency could be lowered by installing panel diffusers or moving vanes to improve the acoustic modal overlap in the chamber. In the 80 Hz to 400 Hz one-third octave bands a successful measurement will be dependent on the type of measurement, the test configuration, the source and microphone locations and the desired accuracy. It is recommended that qualification measurements endorsed in the International Standards be conducted for each particular application.

Grosveld, Ferdinand W.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Nonlinearly stacked low noise turbofan stator

A nonlinearly stacked low noise turbofan stator vane having a characteristic curve that is characterized by a nonlinear sweep and a nonlinear lean is provided. The stator is in an axial fan or compressor turbomachinery stage that is comprised of a collection of vanes whose highly three-dimensional shape is selected to reduce rotor-stator and rotor-strut interaction noise while maintaining the aerodynamic and mechanical performance of the vane. The nonlinearly stacked low noise turbofan stator vane reduces noise associated with the fan stage of turbomachinery to improve environmental compatibility.

Schuster, William B.↗