Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

rustpix

rustpix is a high-performance, open-source Rust library with first-class Python bindings (via PyO3) for processing pixel-detector data in neutron imaging. It targets time-stamping detectors such as Timepix3 (TPX3) at ORNL's Spallation Neutron Source (VENUS beamline), where each detected neutron deposits charge across a cluster of pixels within a very high-rate event stream (96M+ hits/sec). rustpix parses TPX3 event data in parallel using memory-mapped I/O, offers four interchangeable clustering algorithms (ABS adjacency-based search, DBSCAN, graph/union-find connected components, and a parallel grid method), and extracts weighted, super-resolved centroids to produce neutron-event lists. A streaming architecture lets it process files larger than available memory. rustpix is distributed as a pip-installable Python package (with NumPy integration), Rust crates, a command-line tool, and an interactive GUI; it writes HDF5, Apache Arrow, and CSV; and it is designed to extend to TPX4 and other detector types. Released as open-source under the MIT License.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements

The US Department of Energy National Nuclear Security Administration and the European Atomic Energy Community (Euratom) are collaborating with the Radiation and Nuclear Safety Authority in Finland to assess spent fuel verification methods for potential application to measurements at the planned spent fuel encapsulation plant and geological repository prior to final disposal in Finland. The fork detector (FDET) used to measure the neutron and gamma radiation from a given spent fuel assembly is an existing technology widely used by the International Atomic Energy Agency (IAEA) and Euratom for the safeguards verification of spent fuel operator declaration. Recently, an FDET data analysis software, referred to as the ORIGEN module, was developed and incorporated into the IAEA/Euratom Integrated Review and Analysis Program. This module uses the ORIGEN burnup code to calculate the nuclide concentrations and the neutron and gamma source terms in the spent fuel based on operator declarations. Then, to predict the expected FDET signals for a given fuel assembly, the module combines the source terms calculated by ORIGEN with FDET response functions that were pre-generated using MCNP models. The inspector can compare the calculated signals to the measured values in real time to identify possible anomalies in fuel assembly’s operator declaration, integrity, or measurement. In this work, the capability of the ORIGEN module was extended from application to typical light water reactor fuels to use for VVER-440 assembly types. The accuracy of ORIGEN for this type of fuel assembly calculations was assessed by comparing calculated nuclide concentrations against destructive assay measurements for VVER-440 spent fuel. The performance of the ORIGEN module for FDET safeguards verification in routine inspections was assessed using FDET measurement data for 13 spent VVER-440 assemblies that were measured at the Loviisa Nuclear Power Plant in Finland, by comparing the calculated signals to the measured quantities. The results show that the calculated FDET neutron and gamma detector signals are generally within 12% of the measurements except for one assembly. Thus, these results are applicable to future safeguards verification in the planned Finland encapsulation plant, such as for passive neutron albedo reactivity safeguards measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Survey of Neutron Flux Sensors for Monitoring Advanced Reactor Concepts Operating with Low Neutron Fluence Rate and Extended Uninterrupted Lifespans

The purpose of this report is to provide a survey of neutron sensors applicable to the low power levels (low neutron fluence rate) for reactor monitoring and controls. A survey of detectors for reactor power monitoring and controls from various commercial vendors—Reuter Stokes, Framatome, Exosens, and Mirion—is presented in the following sections based on application of reactor power ranges. Detector specifications are provided where available per each of the vendor’s catalogues and specification sheets found on their websites. While this is not an all encompassing list, it provides an example of detector options. Fission chambers and self powered neutron detectors (SPNDs) for in-core application with changes to the neutron-sensitive materials—fissile depots for fission chambers and emitters for SPNDs—for regenerative capabilities will be discussed in the latter sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

Measurement of neutron production in atmospheric neutrino interactions at Super-Kamiokande

We present measurements of total neutron production from atmospheric neutrino interactions in water, analyzed as a function of electron-equivalent visible energy over a range of 30 MeV to 10 GeV. These results are based on 4,270 days of data collected by Super-Kamiokande, including 564 days with 0.011 wt% gadolinium added to enhance neutron detection. Neutron signal selection is based on a neural network trained on simulation, with its performance validated using an Am/Be neutron point source. The measurements are compared to predictions from neutrino event generators combined with various hadron-nucleus interaction models, which include an intranuclear cascade model and a nuclear deexcitation model. We observe significant variations in the predictions depending on the choice of hadron-nucleus interaction model. We discuss key factors that contribute to describing our data, such as in-medium effects in the intranuclear cascade and the accuracy of statistical evaporation modeling.

Cherenkov detectors↗

Calibration of large neutron detection arrays using cosmic rays

Cosmic muons are used to calibrate the position, light output and the relative timing offset of the Large Area Neutron Array (LANA). Each 2 × 2 m 2 LANA wall consists of twenty-five horizontal neutron detection bars. Each bar is 2 m long with a cross-section of 6.35 × 7.62 cm 2 Pyrex container filled with NE-213 organic scintillation liquid. The average position and time resolution of a bar is found to be about 8 cm and 500 ps FWHM, respectively. Furthermore, our method provides an accurate, fast and convenient calibration of LANA that can be applied to general scintillation arrays without the use of radioactive sources or beams.

79 ASTRONOMY AND ASTROPHYSICS↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗