Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Appendix A: The Impact of the HP 5071A on International Atomic Time

The international clock ensemble, which contributes to the generation of International Atomic Time (TAI and UTC) has improved dramatically over the last few years. The main change has been the introduction of a significant number of HP 5071A clocks. Of the 313 clocks contributing to TAI/UTC during 1994, 94 of these were HP 5071As. The environmental insensitivity of the HP 5071A clocks is more than an order of magnitude better than that of previously contributing clocks. This environmental insensitivity translates to outstanding long-term stability - with a typical flicker floor of a few x10(sup -15). in addition, there are now several hydrogen masers with cavity tuning contributing to TAI/UTC. These not only have outstanding short-term stability, but comparatively low frequency drifts and excellent intermediate-type frequency stability. By analyzing data available from the international ensemble, we have obtained two important results. First the frequency stability obtainable with an optimum algorithm is about 10(sup -15) for both the intermediate and long-term regions. It could be as good in the short-term (if time transfer measurement instabilities were reduced sufficiently. Second, with cooperation, this performance can be made available on an international basis in near real time. The recent enhancements in the contributing clocks are already providing a significant improvement in the accuracy with which UTC is made available to the world from several of the national timing centers, such as the National Institute for Standards and Technology (NIST) and the US Naval Observatory (USNO).

Allan, David W.↗

Computational Intelligence and Its Impact on Future High-Performance Engineering Systems

This document contains presentations from the joint UVA/NASA Workshop on Computational Intelligence held at the Virginia Consortium of Engineering and Science Universities, Hampton, Virginia, June 27-28, 1995. The presentations addressed activities in the areas of fuzzy logic, neural networks, and evolutionary computations. Workshop attendees represented NASA, the National Science Foundation, the Department of Energy, National Institute of Standards and Technology (NIST), the Jet Propulsion Laboratory, industry, and academia. The workshop objectives were to assess the state of technology in the Computational intelligence area and to provide guidelines for future research.

Noor, Ahmed K.↗

Solid State Research

This report covers in detail the research work of the Solid State Division at Lincoln Laboratory for the period 1 May-31 July 1995. The topics covered are: Electrooptical Devices, Quantum Electronics, Materials Research, Submicrometer Technology, High Speed Electronics, Microelectronics, and analog device technology. Funding is provided primarily by the Air Force, with additional Support provided by the Army, ARPA, Navy, BMDO, NASA and NIST.

Shaver, David C.↗

EOS Contract Report: The ASTER and MODIS Projects

Three major tasks occupied the group's efforts during this six months. The first was measuring the bidirectional reflectance properties of four reflectance samples provided by NIST. S. Biggar and P. Spyak made these measurements in both the VNIR and SWIR. The second major task was the group's move to a new facility in March. This required that our calibration laboratory and blacklab be disassembled and reassembled in addition to moving offices and other equipment. The third task was the joint vicarious calibration that took place the latter half of June. This campaign included two weeks of laboratory measurements by the RSG and nine days in the field. Other work during the past six months consisted of Science Team support activities including the attendance at meetings related to MODIS and ASTER. In addition, K. Scott continued work on the cross-calibration software package by developing a graphical interface to 6S, an uncertainty analysis code, and an image registration module. M. Sicard used a trip to Cimel in France to change the Cimel TIR radiometer's field of view and then characterized this new field of view. Z. Rouf and Z. Murshalin processed radiance-based data from last summer's Lunar Lake campaign.

Slater, P.↗

Solid State Research

This report covers in detail the research work of the Solid State Division at Lincoln Laboratory for the period 1 May - 31 July 1996. The topics covered are Electrooptical Devices, Quantum Electronics, Materials Research, Submicrometer Technology, High Speed Electronics, Microelectronics, and Analog Device Technology. Funding is provided primarily by the Air Force, with additional Support provided by the Army, DARPA, Navy, BMDO, NASA, and NIST.

SOLID STATE PHYSICS↗

Evaluation of Exposure From a Low Energy X-Ray Device Using Thermoluminescent Dosimeters

The exposure from an electron beam welding device was evaluated using thermoluminescent dosimeters (TLDs). The device generated low energy X-rays which the current dose equivalent conversion algorithm was not designed to evaluate making it necessary to obtain additional information relating to TLD operation at the photon energies encountered with the device. This was accomplished by performing irradiations at the National Institute of Standards and Technology (NIST) using low energy X-ray techniques. The resulting data was used to determine TLD badge response for low energy X-rays and to establish the relationship between TLD element response and the dose equivalent at specific depths in tissue for these photon energies. The new energy/dose equivalent calibration data was used to calculate the shallow and eye dose equivalent of badges exposed to the device.

Edwards, David L.↗

Atmospheric and Spectroscopic Research in the Far Infrared

The spectroscopic measurements of molecular parameters constitute one of the major areas of our research program. This part of our program has been conducted in close collaboration with Smithsonian Astrophysical Observatory (SAO) and National Institute of Standards and Technology (NIST). The references on HO2, OH, and O2 that appear on the publication list are examples of this type of work completed during the grant period. These pressure-broadening studies have provided the kind of improvements needed in the database for retrieving atmospheric profiles from far infrared limb sensing data. One example of this linkage between the pressure broadening studies and the improvements in data retrieval is described in the paper on HBr (paper #4, publication list). The retrieval of the concentration profile of this important species from the IBEX data was facilitated by a number of performance improvement factors, not the least of which was the database improvements.

Park, Kwangjai↗

Semi-Annual Status Report

This 6 month period continued the effort on absolute spectrally continuous stellar calibration begun in January 1991. The Midcourse Space Experiment (MSX) DCATT team has continued its analysis and intercomparisons of the Spatial Infrared Imaging Telescope (SPIRIT-III) ground calibration, the on-orbit stellar calibration (using our stellar spectra), and the on-orbit observations of the MIT Lincoln Labs. "emissive spheres". All three approaches are in very good agreement, at about the +/-3% level (absolute). This demonstrates the consistency of our overall calibration scheme and validates the context in which Infrared Space Observatory (ISO) and MSX data also reside. Final "globalization" of the overall MSX calibration is in progress, combining calibrations by stars, by the "emissive spheres" experiments, and by the NIST-traceable ground calibration. The work in support of the Infrared Telescope Satellite (IRTS) continues. I am currently calculating the contribution of diffuse starlight to the background in "dark" regions of the sky observed by the IRTS Near-IR Spectrometer. To accomplish this I am using the SKY model with a new extended wavelength capability, covering the 1.00-2.00 micron region for the first time. These calculations, together with models of the zodiacal light, will be used to seek the presence of a cosmic near-IR background. Papers VIII and IX in the calibration series appeared in this 6 month period. These describe our results on asteroid thermal nodes and anticipate the eventual production of a new network of stellar calibrators, numbering over 400 and extending over the whole sky. These will be constructed as stellar "templates", building on the legacy of our series of calibration papers. The first analyses of star counts from MSX are under way using SKY.

Cohen, Martin↗

SeaWiFS Postlaunch Technical Report Series: The 1997 Prelaunch Radiometric Calibration of SeaWiFS - Volume 4

The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was originally calibrated by the instrument's manufacturer, Santa Barbara Research Center (SBRC), in November 1993. In preparation for an August 1997 launch, the SeaWiFS Project and the National Institute of Standards and Technology (NIST) undertook a second calibration of SeaWiFS in January and April 1997 at the facility of the spacecraft integrator, Orbital Sciences Corporation (OSC). This calibration occurred in two phases, the first after the final thermal vacuum test, and the second after the final vibration test of the spacecraft. For the calibration, SeaWiFS observed an integrating sphere from the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at four radiance levels. The spectral radiance of the sphere at these radiance levels was also measured by the SeaWiFS Transfer Radiometer (SXR). In addition, during the calibration, SeaWiFS and the SXR observed the sphere at 16 radiance levels to determine the linearity of the SeaWiFS response. As part of the calibration analysis, the GSFC sphere was also characterized using a GSFC spectroradiometer. The 1997 calibration agrees with the initial 1993 calibration to within +/- 4%. The new calibration coefficients, computed before and after the vibration test, agree to within 0.5%. The response of the SeaWiFS channels in each band is linear to better than 1%. In order to compare to previous and current methods, the SeaWiFS radiometric responses are presented in two ways: using the nominal center wave-lengths for the eight bands; and using band-averaged spectral radiances. The band-averaged values are used in the flight calibration table. An uncertainty analysis for the calibration coefficients is also presented.

Hooker, Stanford B.↗

Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

Ferris, A. T. Judy↗

Survey of Fire Detection Technologies and System Evaluation/Certification Methodologies and Their Suitability for Aircraft Cargo Compartments

As part of the National Aeronautics and Space Administration (NASA) initiated program on global civil aviation, NIST is assisting Federal Aviation Administration in its research to improve fire detection in aircraft cargo compartments. Aircraft cargo compartment detection certification methods have been reviewed. The Fire Emulator-Detector Evaluator (FE/DE) has been designed to evaluate fire detection technologies such as new sensors, multi-element detectors, and detectors that employ complex algorithms. The FE/DE is a flow tunnel that can reproduce velocity, temperature, smoke, and Combustion gas levels to which a detector might be exposed during a fire. A scientific literature survey and patent search have been conducted relating to existing and emerging fire detection technologies, and the potential use of new fire detection strategies in cargo compartment areas has been assessed. In the near term, improved detector signal processing and multi-sensor detectors based on combinations of smoke measurements, combustion gases and temperature are envisioned as significantly impacting detector system performance.

Cleary, T.↗

Atmospheric and Spectroscopic Research in the Far Infrared

The spectroscopic measurements of molecular parameters constitute one of the major areas of our research program. This part of our program has been conducted in close collaboration with Smithsonian Astrophysical Observatory (SAO) and National Institute of Standards and Technology (NIST). The references on HO2, OH, and O2 that appear on the publication list are examples of this type of work completed during the grant period. These pressure-broadening studies have provided the kind of improvements needed in the database for retrieving atmospheric profiles from far infrared limb sensing data. Authors summarized the laboratory spectroscopic studies conducted during the grant period. We attempted to measure the pressure broadening coefficients of the O2 lines in the 50 and 117/ cm regions. An accurate characterization of these lines using the IBEX detector system was needed to analyze the flight data. These are difficult lines to measure because they arise from weak magnetic dipole transitions. We used a 4-meter absorption cell to obtain the pressure broadening coefficients for the 50 and 83 /cm lines. We also completed the pressure broadening studies including the temperature dependence of two lines of OH at 83 and 118 /cm. These two lines are important not only for the balloon data retrieval work but also for the future project proposals.Another area of focus in our program is the far infrared detector research. The third area of focus deals with data distribution and dissemination.

Park, Kwangjai↗

Intercomparison of Laboratory Radiance Calibration Standards

Several standards for radiometric calibration were measured repeatedly with a spectroradiometer in order to understand how they compared in accuracy and stability. The tested radiance standards included a NIST 1000 W bulb and halon panel, two calibrated and stabilized integrating spheres, and a cavity blackbody. Results indicate good agreement between the blackbody and 1000 W bulb/spectralon panel, If these two radiance sources are assumed correct, then the integrating spheres did not conform. to their manufacturer-reported radiances in several regions of the spectrum. More detailed measurements am underway to investigate the discrepancy.

Pavri, Betina↗

A Technology Demonstration Experiment for Laser Cooled Atomic Clocks in Space

We have been developing a laser-cooling apparatus for flight on the International Space Station (ISS), with the intention of demonstrating linewidths on the cesium clock transition narrower than can be realized on the ground. GLACE (the Glovebox Laser- cooled Atomic Clock Experiment) is scheduled for launch on Utilization Flight 3 (UF3) in 2002, and will be mounted in one of the ISS Glovebox platforms for an anticipated 2-3 week run. Separate flight definition projects funded at NIST and Yale by the Micro- gravity Research Division of NASA as a part of its Laser Cooling and Atomic Physics (LCAP) program will follow GLACE. Core technologies for these and other LCAP missions are being developed at JPL, with the current emphasis on developing components such as the laser and optics subsystem, and non-magnetic vacuum-compatible mechanical shutters. Significant technical challenges in developing a space qualifiable laser cooling apparatus include reducing the volume, mass, and power requirements, while increasing the ruggedness and reliability in order to both withstand typical launch conditions and achieve several months of unattended operation. This work was performed at the Jet Propulsion Laboratory under a contract with the National Aeronautics and Space Administration.

Klipstein, W. M.↗

Endpoint Security Using Biometric Authentication for Secure Remote Mission Operations

We propose a flexible security authentication solution for the spacecraft end-user, which will allow the user to interact over Internet with the spacecraft, its instruments, or with the ground segment from anywhere, anytime based on the user's pre-defined set of privileges. This package includes biometrics authentication products, such as face, voice or fingerprint recognition, authentication services and procedures, such as: user registration and verification over the Internet and user database maintenance, with a configurable schema of spacecraft users' privileges. This fast and reliable user authentication mechanism will become an integral part of end-to-end ground-to-space secure Internet communications and migration from current practice to the future. All modules and services of the proposed package are commercially available and built to the NIST BioAPI standard, which facilitates "pluggability" and interoperability.

Donohue, John T.↗

Performance Monitoring of Distributed Data Processing Systems

Test and checkout systems are essential components in ensuring safety and reliability of aircraft and related systems for space missions. A variety of systems, developed over several years, are in use at the NASA/KSC. Many of these systems are configured as distributed data processing systems with the functionality spread over several multiprocessor nodes interconnected through networks. To be cost-effective, a system should take the least amount of resource and perform a given testing task in the least amount of time. There are two aspects of performance evaluation: monitoring and benchmarking. While monitoring is valuable to system administrators in operating and maintaining, benchmarking is important in designing and upgrading computer-based systems. These two aspects of performance evaluation are the foci of this project. This paper first discusses various issues related to software, hardware, and hybrid performance monitoring as applicable to distributed systems, and specifically to the TCMS (Test Control and Monitoring System). Next, a comparison of several probing instructions are made to show that the hybrid monitoring technique developed by the NIST (National Institutes for Standards and Technology) is the least intrusive and takes only one-fourth of the time taken by software monitoring probes. In the rest of the paper, issues related to benchmarking a distributed system have been discussed and finally a prescription for developing a micro-benchmark for the TCMS has been provided.

Ojha, Anand K.↗

Arctic Gas Phase Water Vapor Measurements from the NASA DC-8 During SOLVE

The NASA Langley / Ames Diode Laser Hygrometer (DLH) was flown aboard the NASA DC-8 during all three arctic deployments of the SOLVE campaign. The DLH measures gas phase H2O in the freestream air between the fuselage and the outer right engine cowling, essentially free from aircraft perturbations. It uses wavelength-modulated near-IR laser radiation at about 1.4 microns to detect the H2O absorption. Calibration is based on short path experiments in the laboratory using a NIST-traceable dewpoint hygrometer with carefully conditioned air at dewpoints between - 10 and + 10 degrees C. The theory of operation of the DLH instrument will be presented, along with a description of the calibration methodology. A simple climatology of H2O observations from SOLVE will be presented.

Podolske, James↗

Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

Nguyen, Truong X.↗