Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multivariate sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

297 records · Page 17

Contraceptive Sabotage and Contraceptive Use at the Time of Pregnancy: An Analysis of People with a Recent Live Birth in the United States

Contraceptive sabotage and other forms of intimate partner violence (IPV) can interfere with contraceptive use. We used 2012 to 2015 Pregnancy Risk Assessment Monitoring System data from 8,981 people residing in five states who reported that when they became pregnant, they were not trying to get pregnant. We assessed the relationships between ever experiencing contraceptive sabotage and physical IPV 12 months before pregnancy (both by the current partner) and contraceptive use at the time of pregnancy using multivariable logistic regression. We also assessed the joint associations between physical IPV 12 months before pregnancy and ever experienced contraceptive sabotage with contraceptive use at the time of pregnancy. Few people ever experienced contraceptive sabotage (1.8%; 95% confidence interval [CI]: 1.4, 2.3) or physical IPV 12 months before pregnancy (2.8%; 95% CI: 2.3, 3.3). In models adjusted for age, race/ethnicity, marital status, education, and state of residence, ever experiencing contraceptive sabotage was associated with contraceptive use at the time of pregnancy (adjusted odds ratio [aOR]: 1.73; 95% CI: 1.06, 2.82), but not with physical IPV 12 months before pregnancy (aOR: 0.69; 95% CI: 0.46, 1.02). When examining the joint association, compared to not ever experiencing contraceptive sabotage or physical IPV 12 months before pregnancy, ever experiencing contraceptive sabotage was significantly related to contraceptive use at the time of pregnancy (aOR: 1.72; 95% CI: 1.00, 2.95). However, it was not associated with experiencing physical IPV 12 months before pregnancy (aOR: 0.68; 95% CI: 0.45, 1.04) or with experiencing both contraceptive sabotage and physical IPV 12 months before pregnancy (aOR: 1.21; 95% CI: 0.42, 3.50), compared to not ever experiencing contraceptive sabotage or physical IPV 12 months before pregnancy. Our study highlights that current partner contraceptive sabotage may motivate those not trying to get pregnant to use contraception; however, all people in our sample still experienced a pregnancy.

Huber-Krum, Sarah↗

Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

Non-NASA Center↗

A Performance Comparison of Low-Cost Near-Infrared (NIR) Spectrometers to a Conventional Laboratory Spectrometer for Rapid Biomass Compositional Analysis

The performance of a conventional laboratory near-infrared (NIR) spectrometer and two NIR spectrometer prototypes (a Texas Instruments NIRSCAN Nano evaluation model (EVM) and an InnoSpectra NIR-M-R2 spectrometer) are compared by collecting reflectance spectra of 270 well-characterized herbaceous biomass samples, building calibration models using the partial least squares (PLS-2) algorithm to predict five constituents of the samples from the reflectance spectra, and comparing the resulting model statistics. The prediction models developed using spectra from the Foss XDS spectrometer were slightly better than the prediction models developed using spectra from either the TI NIRSCAN Nano EVM and the InnoSpectra NIR-M-R2 as measured by the root mean square error (RMSECV) and the correlation coefficient (R 2 _cv) for “leave-one-out” cross-validation (CV). The models built from the two prototype units were not statistically significantly different from each other (p = 0.05). The Foss spectrometer has a larger wavelength range (400–2500 nm) compared with the two prototypes (900–1700 nm). When the spectra from the Foss XDS spectrometer were truncated so their wavelength range matched the wavelength range of the two prototype units, the resulting model was not statistically significantly different from the models from either prototype.

47 OTHER INSTRUMENTATION↗

Vector-Ordering Filter Procedure for Data Reduction

The vector-ordering filter (VOF) technique involves a procedure for sampling a large population of data vectors to select a subset of data vectors that fully characterize the state space of the large population. The VOF technique enables a large reduction of the volume of data that must be handled in the automated monitoring system and method discussed in the two immediately preceding articles. In so doing, the VOF technique enables the development of data-driven mathematical models of a monitored asset from sets of data that would otherwise exceed the memory capacities of conventional engineering computers. Data-driven mathematical models have been shown to offer high fidelity for purposes of control and monitoring of assets. In practice, a collection of asset-operating observations is acquired with the intention that the collection contain observations characteristic of the full dynamic range of operation of the asset. Often, such a collection contains an extremely large number of observations, many of which are redundant. The VOF technique fills the need for a means to extract, from the original collection of observational data, a reduced data matrix that excludes redundant data while maintaining the full statistical character and dynamic range of the original data. The reduced data matrix can then be used as the input data for development of a mathematical model of the monitored asset, or as training data for a neural-network substitute for an explicit mathematical model of the asset. Alternatively, the reduced data matrix can, itself, be used directly as a mathematical model of the monitored asset, as is commonly done in multivariate state-estimation techniques. The original data are collected from the asset over a range of operating states and are put in matrix form. Each column vector in the original data matrix represents the signal values acquired at a particular operational state of the asset. Thus, the number of columns of the original data matrix equals the number of observed states and the number of rows in this matrix equals the number of signals acquired at each observation. In the VOF technique, one extracts the reduced data matrix from the original data matrix through the selection of a representative subset of the column (state) vectors.

Bickford, Randall L.↗

The Validity Chlorophyll-a Estimation by Sun Induced Fluorescence in Estuarine Waters: An Analysis of Long-term (2003-2011) Water Quality Data from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chlorophyll-a inaccurate. Measurement of sun-induced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum, may provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite baseline algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms using a comprehensive long term in situ data set. In an unprecedented analysis of a long term (2003-2011) in situ monitoring data from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer (MODIS) against chlorophyll ]a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions within the estuary including water depth, distance from shore and structures and eight water quality parameters. From the 39 station for which data was derived, 22 stations showed significant correlations when the FLH product was matched with in situ chlorophyll-alpha data. The correlations (r2) for individual stations within Tampa Bay ranged between 0.67 (n=28, pless than 0.01) and-0.457 (n=12, p=.016), indicating that for some areas within the Bay, FLH can be a good predictor of chlorophyll-alpha concentration and hence a useful tool for the analysis of water quality. Overall, the results show a 106% increase in the validity of chlorophyll -a concentration estimates using FLH over the standard the blue-green OC3M algorithm. This analysis also illustrates that the correlations between FLH and in situ chlorophyll -a measurements increases with increasing water depth and distance of the monitoring sites from both the shore and structures. However, due to confounding factors related to the complexity of the estuarine system, a linear improvement in the FLH to chlorophyll ]a relationship was not clearly noted with increasing depth and distance from shore alone. Correlations of FLH with turbidity, nutrients (total nitrogen and total phosphorous) biological oxygen demand, salinity, sea surface temperature correlated positively with FLH concentrations, while dissolved oxygen and pH showed negative correlations. Principle component analyses are employed to further describe the relationships between the multivariate water quality parameters and the FLH product. The majority of sites with higher and very significant correlations (pless than 0.01) also showed high correlation values for nutrients, turbidity and biological oxygen demand. These sites were on average in greater than seven meters of water and over five kilometers from shore. A thorough understanding of the relationship between the MODIS FLH product and in situ water quality parameters will enhance our understanding of the accuracy MODIS fs global FLH algorithm and assist in optimizing its calibration for use in monitoring the quality of estuarine and coastal waters worldwide.

Moreno-Madrinan, Max Jacobo↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advantages of Intraprocedural Unenhanced CT During Adrenal Venous Sampling to Confirm Accurate Catheterization of the Right Adrenal Vein

Purpose: To evaluate the advantages of intraprocedural CT during adrenal venous sampling (AVS) to confirm accurate catheterization of the right adrenal vein (RAV). Materials and Methods: This single-institution study included 106 patients (mean age 52.4 years; range 28–74 years) with primary aldosteronism who performed contrast-enhanced CT (CECT) before AVS following AVS between January 2011 and March 2018. After catheterization of the RAV under fluoroscopic guidance, unenhanced CT images were obtained to confirm catheter position on unified CT angiography system. Catheter repositioning was performed when the catheter was inaccurately positioned. Venography findings were classified into two groups: (1) presumably cannulated in the RAV (presumed RAV group) and (2) obscured visualization of the RAV because of collateral vessels (obscured RAV group). Success rates of AVS were compared using Fisher’s exact test. Results: The overall success of AVS was achieved in 104 patients (98.1%). Catheter was deviated into the IVC during intraprocedural CT in four patients. Fourteen patients (14.0%) required catheter repositioning by intraprocedural CT images, and accurate catheterization in the RAV was eventually accomplished. The success rate of AVS was significantly higher in the presumed RAV group (90.1% [73/81]) than that in the obscured RAV group (68.4% [13/19]) (p = 0.024). If intraprocedural CT was not acquired during AVS, the success rate of AVS would have been significantly lower (84.9% [90/106]) compared with that use of intraprocedural CT (98.1% [104/106]) (p < 0.001). Conclusions: Intraprocedural unenhanced CT by referring to the preprocedural CECT before AVS enables the confirmation of accurate catheterization of the RAV. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inorganic characterization of switchgrass biomass using laser-induced breakdown spectroscopy

The inorganic characterization of 74 samples of switchgrass using laser-induced breakdown spectroscopy (LIBS) was undertaken. Determination of ash and inorganic elements content in biomass materials is vital for feedstock screening for bioconversion processes. Hierarchical models using principal component analysis (PCA) and partial least square analysis (PLS) were used to determine the presence of specific elemental micronutrients that are important in determining plant health for robust biomass production. LIBS uses a 532 nm laser with 45 mJ of laser power to excite the samples of switchgrass plant material and the emission of all the elements present in the plant samples were recorded in single spectra with a wide wavelength range of 200–800 nm. The results were compared to the laboratory standard technique, e.g., ICP-OES technique, to determine the true values for major micronutrients such as, silicon (Si), potassium (K), calcium (Ca), magnesium (Mg), phosphorus (P), and sulfur (S). Overall, our objectives were: 1) To determine the spectral features of switchgrass containing different amounts of these elements and 2) To examine the viability of this technique for determining the quality of the feedstock in terms of its inorganic composition. Cross-validation results showed that the broad-based model developed is promising for inorganics prediction in switchgrass. The LIBS validation prediction for the micronutrient elements mentioned here have been obtained. The regression coefficients for Si, were obtained to be 0.995, 0.994 for calibration and validation respectively, in case of Ca the regression coefficients were, 0.994 and 0.992 for calibration and validation. Similarly, in the case of Mg and K these were calculated to be 0.992 and 0.985, and 0.994 and 0.993 respectively. The regression coefficients are not as good as those for the elements mentioned, in case of the two elements S and P. They are 0.957, and 0.878, and 0.952 and 0.894 respectively for calibration, validation for the two elements. This demonstrates that LIBS-based techniques are inherently well suited for diverse environmental applications. Furthermore, LIBS along with PLS model can show capability in determining the viability of switchgrass as a biomass in the production of biofuels and survivability of switchgrass in processes associated with climate change. LIBS can help determining which switchgrass would be appropriate for a specific conversion process that favors low ash content overall or low value of specific inorganics.

59 BASIC BIOLOGICAL SCIENCES↗