Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

WE-FG-BRA-07: Theranostic Nanoparticles Improve Clinical MR-Guided Radiation Therapy

Purpose: MR-guided radiation therapy is a current and emerging clinical reality. We have designed and tested a silica-based gadolinium chelates nanoparticle (AGuIX) for integration with MR-guided radiation therapy. The AGuIX nanoparticles used in this study are a dual-modality probe with radiosensitization properties and better MRI contrast than current FDA-approved gadolinium chelates. In advance of an approved Phase I clinical trial, we report on the efficacy and safety in multiple animal models and clinically relevant radiation conditions. By modeling our study on current clinic workflows, we show compatibility with modern patient care, thus heightening the translational significance of this research. Methods: The dual imaging and therapy functionality of AGuIX was investigated in mice with clinical radiation beams while safety was evaluated in mice, and nonhuman primates after systemic injection of 0.25 mg/g of nanoparticles. MRI/ICP-MS were used to measure tumor uptake and biodistribution. Due to their small size (2–3 nm), AGuIX have good renal clearance (t1/2=19min). We performed in vitro cell uptake quantification and radiosensitization studies (clonogenic assays and DNA damage quantification). In vivo radiation therapy studies were performed with both 6MV and 6MV-FFF clinical radiation beams. Histology was performed to measure the increase in DNA damage in the tumor and to evaluate the toxicity in healthy tissues. Results: In vitro and in vivo results demonstrate statistically significant increase (P < 0.01) in DNA damage, tumor growth supression and survival (+100 days) compared to radiation alone. Negligible toxicity was observed in all of the animal models. The combination of 6MV-FFF/AGuIX demonstrated a substantial dose enhancement compared to 6MV/AGuIX (DEF = 1.36 vs. 1.22) due to the higher proportion of low energy photons. Conclusion: With demonstrated efficacy and negligible toxicity in mice and non-human primates, AGuIX is a biocompatible nanoplatform with strong translational potential for MR-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Pragmatic Uncertainty Quantification and Propagation in Inverse Estimation of Structural Dynamics Parameters given Material Property Uncertainties and Limited Sensor Data

In this report we demonstrate some relatively simple and inexpensive methods to effectively account for various sources of epistemic lack-of-knowledge type uncertainty in inverse problems. The demonstration problem involves inverse estimation of six parameters of a bolted joint that attaches a kettlebell shaped object to a thick plate. The parameters are efficiently inverted in a modal-based model calibration using gradient-based optimization. Two material properties of the kettlebell are treated as uncertain to within given epistemic uncertainty bounds. We apply and test interval and sparse-sample probabilistic approaches to account for uncertainty in the estimated parameters (and various scalar functionals of the parameters as generic quantities of interest, QOIs) due to uncertainties in the material properties. We also investigate the error effects of limited numbers of vibration sensors (accelerometers) on the kettlebell and plate, and therefore abbreviated excitation/response information in the parameter inversions. We propose and demonstrate a Leave-K-Sensors-Out “cross-prediction” UQ approach to estimate related uncertainties on the parameters and QOI functionals. We indicate how uncertainties from material properties and limited sensors are treated in a combined manner. The economical combined UQ approach involves just three to five samples (i.e. three to five inverse simulations), with no added complication or error/uncertainty from use of surrogate models for affordability. Finally, we describe a related economical UQ approach for handling potential parameter solution non-uniqueness and numerical optimization related precision uncertainties in the estimated parameter values. Indicated further research is identified.

36 MATERIALS SCIENCE↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

42 ENGINEERING↗

Proton Beam Therapy and Concurrent Chemotherapy for Esophageal Cancer

Purpose: Proton beam therapy (PBT) is a promising modality for the management of thoracic malignancies. We report our preliminary experience of treating esophageal cancer patients with concurrent chemotherapy (CChT) and PBT (CChT/PBT) at MD Anderson Cancer Center. Methods and Materials: This is an analysis of 62 esophageal cancer patients enrolled on a prospective study evaluating normal tissue toxicity from CChT/PBT from 2006 to 2010. Patients were treated with passive scattering PBT with two- or three-field beam arrangement using 180 to 250 MV protons. We used the Kaplan-Meier method to assess time-to-event outcomes and compared the distributions between groups using the log-rank test. Results: The median follow-up time was 20.1 months for survivors. The median age was 68 years (range, 38-86). Most patients were males (82%) who had adenocarcinomas (76%) and Stage II-III disease (84%). The median radiation dose was 50.4 Gy (RBE [relative biologic equivalence]) (range, 36-57.6). The most common grade 2 to 3 acute toxicities from CChT/PBT were esophagitis (46.8%), fatigue (43.6%), nausea (33.9%), anorexia (30.1%), and radiation dermatitis (16.1%). There were two cases of grade 2 and 3 radiation pneumonitis and two cases of grade 5 toxicities. A total of 29 patients (46.8%) received preoperative CChT/PBT, with one postoperative death. The pathologic complete response (pCR) rate for the surgical cohort was 28%, and the pCR and near CR rates (0%-1% residual cells) were 50%. While there were significantly fewer local-regional recurrences in the preoperative group (3/29) than in the definitive CChT/PBT group (16/33) (log-rank test, p = 0.005), there were no differences in distant metastatic (DM)-free interval or overall survival (OS) between the two groups. Conclusions: This is the first report of patients treated with PBT/CChT for esophageal cancer. Our data suggest that this modality is associated with a few severe toxicities, but the pathologic response and clinical outcomes are encouraging. Prospective comparison with more traditional approach is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cu/Nb nano-composite wires processed by severe plastic deformation for applications in high pulsed magnets: effects of the multi-scale microstructure on the mechanical properties

Copper-based high strength and high electrical conductivity nano-composite wires reinforced by Nb nano-tubes are prepared by severe plastic deformation, applied with an Accumulative Drawing and Bundling process (ADB), for the windings of high pulsed magnets. The ADB process leads to a multi-scale Cu matrix containing up to N = 85{sub 4} (52.2.10{sup 6}) continuous parallel Nb tubes with diameter down to few tens nano-meters. After heavy strain, the Nb nano-tubes exhibit a homogeneous microstructure with grain size below 100 nm. The Cu matrix presents a multi-scale microstructure with multi-modal grain size distribution from the micrometer to the nano-meter range. The use of complementary characterization techniques at the microscopic and macroscopic level (in-situ tensile tests in the TEM, nano-indentation, in-situ tensile tests under high energy synchrotron beam) shed light on the interest of the multi-scale nature of the microstructure to achieve extreme mechanical properties, therefore allowing for design guidelines to further improve these properties. (authors)

36 MATERIALS SCIENCE↗

An Approach to Assessing the Added Mass for a Plate in a Channel

The Global Threat Reduction initiative (GTRI) was established by the National Nuclear Security Administration (NNSA) in 2004. One of the highlights of the program is to convert research and test reactors at home and abroad from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU) fuels. By switching directly from HEU to LEU, an LEU reactor produces fewer neutrons than an HEU reactor, and in some cases, a direct switch from HEU to LEU results in the reactor being unable to achieve criticality. Under certain circumstances, criticality is achieved and the original neutron fluxes are restored with LEU fuel by adding more fuel elements to the core. Not all reactors, exemplified by the Advanced Test Reactor (ATR) at the Idaho National Lab (INL), have the luxury of simply adding more fuel to the core. In such cases, entirely new designs must be created and tested. The ATR utilizes plate type fuel. During the design and testing of the ATR fuel, flow induced vibrations were identified as potential source for experiment and fuel failure. Flow induced vibrations are problematic to solve because both the frequency of excitation and the modal frequencies of the object need to be determined. For the frequency of the object the frequency is often determined, either theoretically or experimentally without any influence of fluid. When a fluid is introduced, the fundamental frequency of an object can be greatly reduced allowing for resonance between the excitation frequency and the fundamental frequency of the plate. The consequence of such resonance is often failure of the component. Current methods for determining the frequency of a body immersed in a fluid requires the use of multi-physics software in order to determine (if at all possible) the frequency of the object. The work herein provides an alternative means of calculating the frequency of a plate by combining plate frequency theory to determine the added mass on the plate when in the presence of narrow channels. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Test Plan for Underground Hydrogen Storage Demonstration in a Porous Reservoir

Climate and sea level change is causing numerous challenges across the globe to human societies and the cultural and infrastructure investments they have made over hundreds of years based on previous modalities in climate and sea level. Decarbonizing our global economy is therefore essential to stopping additional emissions of CO 2 to the atmosphere. One proposed decarbonization technology that has been advanced as a replacement for the “hydrocarbon economy” that exists today is the “hydrogen economy.” In the hydrogen economy, hydrogen is both an energy carrier and an industrial feedstock that can replace hydrocarbons’ traditional roles in these systems. While most hydrogen is produced from conventional, fossil-based feedstocks, hydrogen comes with the added benefits of being able to be made from water and electricity providing a promising way to store renewable energy from wind and solar developments.

08 HYDROGEN↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feature Detection From LiDAR Point Cloud and Aerial Imagery Using Distance Dependent Chinese Restaurant Process [Slides]

It is possible to integrate data captured by UAS from multiple data modalities spatially. We can detect features by combining information across images and LiDAR point clouds. Performance issues exist with the current algorithms in place & could be improved. We hope to test it for at least 500 iterations. Post processing of data takes enormous efforts in case of data generated by proprietary software tools…We intend to develop a better framework for seamless integration.

97 MATHEMATICS AND COMPUTING↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

A nanocomposite of Au-AgI core/shell dimer as a dual-modality contrast agent for x-ray computed tomography and photoacoustic imaging

Purpose: To develop a core/shell nanodimer of gold (core) and silver iodine (shell) as a dual-modal contrast-enhancing agent for biomarker targeted x-ray computed tomography (CT) and photoacoustic imaging (PAI) applications. Methods: The gold and silver iodine core/shell nanodimer (Au/AgICSD) was prepared by fusing together components of gold, silver, and iodine. The physicochemical properties of Au/AgICSD were then characterized using different optical and imaging techniques (e.g., HR- transmission electron microscope, scanning transmission electron microscope, x-ray photoelectron spectroscopy, energy-dispersive x-ray spectroscopy, Z-potential, and UV-vis). The CT and PAI contrast-enhancing effects were tested and then compared with a clinically used CT contrast agent and Au nanoparticles. To confer biocompatibility and the capability for efficient biomarker targeting, the surface of the Au/AgICSD nanodimer was modified with the amphiphilic diblock polymer and then functionalized with transferrin for targeting transferrin receptor that is overexpressed in various cancer cells. Cytotoxicity of the prepared Au/AgICSD nanodimer was also tested with both normal and cancer cell lines. Results: The characterizations of prepared Au/AgI core/shell nanostructure confirmed the formation of Au/AgICSD nanodimers. Au/AgICSD nanodimer is stable in physiological conditions for in vivo applications. Au/AgICSD nanodimer exhibited higher contrast enhancement in both CT and PAI for dual-modality imaging. Moreover, transferrin functionalized Au/AgICSD nanodimer showed specific binding to the tumor cells that have a high level of expression of the transferrin receptor. Conclusions: The developed Au/AgICSD nanodimer can be used as a potential biomarker targeted dual-modal contrast agent for both or combined CT and PAI molecular imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model-Based Ultrasonic SignalProcessing for the Nondestructive Evaluation of Additive Manufacturing Components

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detection of the part under investigation. A primary ingredient in UT besides the required precision robotic hardware for the acquisition of high quality measurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report, we discuss the basic steps in UT signal processing along with current and future capabilities that must be achieved in order to satisfy the critical demands created by the AM process. In its basic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques to extract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonic excitation from a physics-based perspective. Once developed, we briefly discuss the various choices of excitation signals and their tradeoffs. Next we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.” The underlying pre- and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data. Finally, we discuss some open problems in UT and suggest a much more sophisticated model-based approach expanding these revolutionary ideas and encompassing more realistic signal models that incorporate noise, jitter and other pertinent uncertainties into the processor.

36 MATERIALS SCIENCE↗

Model-Based Ultrasonic Signal Processing for the Nondestructive Evaluation of Additive Manufacturing Components

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detectionof the part under investigation. A primary ingredient in UT besides the required precision robotic hardware for theacquisition of high quality measurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report,we discuss the basic steps in UT signal processing along with current and future capabilities that must be achieved in order to satisfy the critical demands created by the AM process.

42 ENGINEERING↗

The metastable dynamo model of stellar rotational evolution

This paper introduces a new empirical model for the rotational evolution of Sun-like stars—those with surface convection zones and non-convective interior regions. Previous models do not match the morphology of observed (rotation period)-color diagrams, notably the existence of a relatively long-lived 'C-sequence' of fast rotators first identified by Barnes. This failure motivates the Metastable Dynamo Model (MDM) described here. The MDM posits that stars are born with their magnetic dynamos operating in a mode that couples very weakly to the stellar wind, so their (initially very short) rotation periods at first change little with time. At some point, this mode spontaneously and randomly changes to a strongly coupled mode, the transition occurring with a mass-dependent lifetime that is of the order of 100 Myr. I show that with this assumption, one can obtain good fits to observations of young clusters, particularly for ages of 150-200 Myr. Previous models and the MDM both give qualitative agreement with the morphology of the slower-rotating 'I-sequence' stars, but none of them have been shown to accurately reproduce the stellar-mass-dependent evolution of the I-sequence stars, especially for clusters older than a few hundred million years. I discuss observational experiments that can test aspects of the MDM, and speculate that the physics underlying the MDM may be related to other situations described in the literature, in which stellar dynamos may have a multi-modal character.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-182: Feasibility of Dose Painting by Numbers in Proton Therapy with Contour-Driven Plan Optimization

Purpose: The work aims to 1) prove the feasibility of dose painting by numbers (DPBN) in proton therapy with usual contour-driven plan optimization and 2) compare the achieved plan quality to that of rotational IMRT. Methods: For two patients with head and neck cancers, voxel-by-voxel prescription to the target volume (PTV-PET) was calculated from {sup 18} FDG-PET images and converted to contour-based prescription by defining several sub-contours. Treatments were planned with RayStation (RaySearch Laboratories, Sweden) and proton pencil beam scanning modality. In order to determine the optimal plan parameters to approach the DPBN prescription, the effect of the number of fields, number of sub-contours and use of range shifter were tested separately on each patient. The number of sub-contours were increased from 3 to 11 while the number of fields were set to 3, 5, 7 and 9. Treatment plans were also optimized on two rotational IMRT systems (TomoTherapy and Varian RapidArc) using previously published guidelines. Results: For both patients, more than 99% of the PTV-PET received at least 95% of the prescribed dose while less than 1% of the PTV-PET received more than 105%, which demonstrates the feasibility of the treatment. Neither the use of a range shifter nor the increase of the number of fields had a significant influence on PTV coverage. Plan quality increased when increasing number of fields up to 7 or 9 and slightly decreased for a bigger number of sub-contours. Good OAR sparing is achieved while keeping high plan quality. Finally, proton therapy achieved significantly better plan quality than rotational IMRT. Conclusion: Voxel-by-voxel prescriptions can be approximated accurately in proton therapy using a contour-driven optimization. Target coverage is nearly insensitive to the number of fields and the use of a range shifter. Finally, plan quality assessment confirmed the superiority of proton therapy compared to rotational IMRT.

60 APPLIED LIFE SCIENCES↗

Investigation of methods for targeted search of dominant higher modes in subcritical systems

The reactor physics modeling of subcritical systems requires a substantially different approach from that of a critical reactor due to the presence of the so-called higher modes. Earlier investigations showed that the dominant higher modes lie in the inner part of the eigenvalue spectrum, making the conventional eigenvalue searches unfeasible and calling for a targeted search. This paper investigates the possibility of targeted and multitudinous eigenvalue calculation by testing the Krylov-Schur and the Dynamic Modes Decomposition (DMD) method for simple, analytically tractable problems. While the DMD method clearly showed its efficiency in a one-group homogeneous problem, modal analysis of a three-dimensional reflected reactor in two-groups approximation demonstrated that the increasing complexity poses challenges for both methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗