Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evolution of shell gaps in the neutron-poor calcium region from invariant-mass spectroscopy of 37,38 Sc, 35 Ca, 34 K

A fast secondary beam of 37 Ca impinged on a 9 Be target resulting in a set of reactions populating proton-rich nuclei including 35 Ca and the first observations of 37,38 Sc and 34 K. Invariant-mass spectroscopy, used to reconstruct proton decays for these nuclei, yielded three new ground-state masses and information on their low-lying structures. The newly measured mass excesses are: ΔM( 37 Sc) = 3500(410) keV, ΔM( 38 Sc) = –4656(14) keV, and ΔM( 34 K) = –1487(17) keV. These nuclei straddle the well-known Z = 20 shell closure as well as the N = 16 subshell closure. Furthermore, trends in separation energies help elucidate how nuclear structure evolves showing a fading of the Z = 20 shell gap for N ≥ 18 and indications of a N = 16 subshell gap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Searching for Extrasolar Planets with SIM

The Space Interferometry Mission (SIM) will be the first spacebased long base-line Michelson interferometer designed for precision astrometry. SIM will extend the reach of astrometry to cover the entire Galaxy, and will address a wide range of problems in Galactic structure and stellar astrophysics. It will also serve as a technology precursor for future astrophysics missions using interferometers. SIM will be a powerful tool for discovering planets around nearby stars, through detection of the reflex motion, and it will directly measure masses for the planets detected this way. It will have a single-measurement precision of 1 microarcsecond in a frame defined by nearby reference stars, enabling SIM to search for planets with masses as small as a few earth masses around the nearest star. More massive planets will be detectable to much larger distances.

Unwin, Stephen C.↗

Astrophysics to z approx. 10 with Gravitational Waves

The most useful characterization of a gravitational wave detector's performance is the accuracy with which astrophysical parameters of potential gravitational wave sources can be estimated. One of the most important source types for the Laser Interferometer Space Antenna (LISA) is inspiraling binaries of black holes. LISA can measure mass and spin to better than 1% for a wide range of masses, even out to high redshifts. The most difficult parameter to estimate accurately is almost always luminosity distance. Nonetheless, LISA can measure luminosity distance of intermediate-mass black hole binary systems (total mass approx.10(exp 4) solar mass) out to z approx.10 with distance accuracies approaching 25% in many cases. With this performance, LISA will be able to follow the merger history of black holes from the earliest mergers of proto-galaxies to the present. LISA's performance as a function of mass from 1 to 10(exp 7) solar mass and of redshift out to z approx. 30 will be described. The re-formulation of LISA's science requirements based on an instrument sensitivity model and parameter estimation will be described.

Stebbins, Robin↗

Criticality Control Overpack Fire Testing (Phase III)

This report will describe the one test conducted during phase III of the Pipe Overpack Container (POC) test campaign, present preliminary results from these tests, and discuss implications for the Criticality Control Overpack (CCO). The goal of this test was to see if aerosol surrogate material inside the Criticality Control Container (CCC) gets released when the drum lid of the CCO comes off during a thirty-minute long, fully-engulfing, fire test. As expected from POC tests conducted in Phase I and II of this test campaign, the CCO drum lid is ejected about one minute after the drum is exposed to fully-engulfing flames. The remaining pressure inside the drum is high enough to eject the top plywood dunnage a considerable distance from the drum. Subsequently, most of the bottom plywood dunnage supporting the CCC burns off during and after the fire. High pressure buildup inside the CCC and inside two primary containers holding the surrogate powder also results in damage to the filter media of the CCC and the filter-house, thread attachment of the primary canisters. No discernable release of surrogate powder material was detected from the two primary containers when pre- and post-test average mass were compared. However, when the average masses are corrected to account for possible uncertainties in mass measurements, error overlap does not preclude the possibility that some surrogate powder mass may have been lost from these primary canisters. Still, post-test conditions of the secondary canisters enclosing these two primary canisters suggest it is very unlikely this mass loss would have escaped into the CCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental evaluation of resistojet thruster plume shields

The exhaust of an engineering model resistojet has been investigated using rotary pitot probes and a rotary quartz crystal microbalance. The resistojet operated on CO2 propellant at a mass flow rate of 0.29 g/sec in both heated and unheated flows. Measurements of local flow angles in the near field of a conical plume shield indicated that the shield was not wholly effective in confining the flow to the region upstream of its exit plane. However, the absolute levels of the measured mass flux into the backflow region were very low, on the order of 7 x 10 to the -7 power g/sqcm/sec or less. The use of a circualr disk at the exit plane of the existing conical shield showed some benefit in decreasing the amount of backflow by a factor of two. Lastly, a detached shield placed upstream of the resistojet exit plane demonstrated a small degree of local shielding for the region directly behind it.

Carney, Lynnette M.↗

Experimental evaluation of resistojet thruster plume shields

The exhaust of an engineering model resistojet has been investigated using rotary pitot probes and a rotary quartz crystal microbalance. The resistojet operated on CO2 propellant at a mass flow rate of 0.29 g/sec in both heated and unheated flows. Measurements of local flow angles in the near field of a conical plume shield indicated that the shield was not wholly effective in confining the flow to the region upstream of its exit plane. However, the absolute levels of the measured mass flux into the backflow region were very low, on the order of 7 x 10 to the -7 power g/sq cm/sec or less. The use of a circular disk at the exit plane of the existing conical shield showed some benefit in decreasing the amount of backflow by a factor of two. Lastly, a detached shield placed upstream of the resistojet exit plane demonstrated a small degree of local shielding for the region directly behind it.

Carney, Lynnette M.↗

High-resolution spectroscopy of gaseous 83m Kr conversion electrons with the KATRIN experiment

Abstract In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous 83m Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The obtained results represent one of the major commissioning milestones for the subsequent direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the KATRIN beamline. Precise measurement of the narrow K-32, L 3 -32, and N 2,3 -32 conversion electron lines allowed to verify the eV-scale energy resolution of the KATRIN main spectrometer necessary for competitive measurement of the absolute neutrino mass scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on Nuclear Symmetry Energy Parameters

A review is made of constraints on the nuclear symmetry energy parameters arising from nuclear binding energy measurements, theoretical chiral effective field predictions of neutron matter properties, the unitary gas conjecture, and measurements of neutron skin thicknesses and dipole polarizabilities. While most studies have been confined to the parameters 𝑆 𝑉 and L, the important roles played by, and constraints on 𝐾 sym , or, equivalently, the neutron matter incompressibility 𝐾 𝑁 , are discussed. Strong correlations among 𝑆 𝑉 ,𝐿, and 𝐾 𝑁 are found from both nuclear binding energies and neutron matter theory. However, these correlations somewhat differ in the two cases, and those from neutron matter theory have smaller uncertainties. To 68% confidence, it is found from neutron matter theory that 𝑆 𝑉 = 32.0 ± 1.1 MeV, 𝐿 = 51.9 ± 7.9 MeV and 𝐾 𝑁 = 152.2 ± 38.1 MeV. Theoretical predictions for neutron skin thickness and dipole polarizability measurements of the neutron-rich nuclei 48 Ca, 120 Sn, and 208 Pb are compared to recent experimental measurements, most notably the CREX and PREX neutron skin experiments from Jefferson Laboratory. By themselves, PREX I+II measurements of 208 Pb and CREX measurement of 48 Ca suggest 𝐿 = 121 ± 47 MeV and 𝐿 = −5 ± 40 MeV, respectively, to 68% confidence. However, we show that nuclear interactions optimally satisfying both measurements imply 𝐿 = 53 ± 13 MeV, nearly the range suggested by either nuclear mass measurements or neutron matter theory, and is also consistent with nuclear dipole polarizability measurements. This small parameter range implies 𝑅 1.4 = 11.6 ± 1.0 km and Λ 1.4 = 228$^{+148}_{−90}$, which are consistent with NICER X-ray and LIGO/Virgo gravitational wave observations of neutron stars.

neutron skins↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗

The role of dust in mass loss from late-type stars

It is noted that, in almost all late-type stars with measured mass loss rates, there is sufficient momentum in the radiation to dominate the dynamics. The opacity of the material is sufficiently great to render radiation pressure important; the dust forms close enough to the central star for radiation pressure to account for the observed outflow velocities. Pulsations appear to be important in raising the material far enough above the photosphere for grains to condense.

Jura, M.↗

The HST See Change Program. I. Survey Design, Pipeline, and Supernova Discoveries*

The See Change survey was designed to make z > 1 cosmological measurements by efficiently discovering high-redshift Type Ia supernovae (SNe Ia) and improving cluster mass measurements through weak lensing. This survey observed twelve galaxy clusters with the Hubble Space Telescope (HST) spanning the redshift range z = 1.13–1.75, discovering 57 likely transients and 27 likely SNe Ia at z ~ 0.8–2.3. As in similar previous surveys, this proved to be a highly efficient use of HST for supernova observations; the See Change survey additionally tested the feasibility of maintaining, or further increasing, the efficiency at yet higher redshifts, where we have less detailed information on the expected cluster masses and star formation rates. Furthermore, we find that the resulting number of SNe Ia per orbit is a factor of ~8 higher than for a field search, and 45% of our orbits contained an active SN Ia within 22 rest-frame days of peak, with one of the clusters by itself yielding 6 of the SNe Ia. We present the survey design, pipeline, and supernova discoveries. Novel features include fully blinded supernova searches, the first random forest candidate classifier for undersampled IR data (with a 50% detection threshold within 0.05 mag of human searchers), real-time forward-modeling photometry of candidates, and semi-automated photometric classifications and follow-up forecasts. We also describe the spectroscopic follow-up, instrumental in measuring host galaxy redshifts. The cosmology analysis of our sample will be presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

Charged-particle fluxes from breakdown events were studied. Methods to measure mass spectra and total emitted flux of neutral particles were developed. The design and construction of the specialized mass spectrometer was completed. Electrical breakdowns were initiated by a movable blunt contact touching the insulating surface. The contact discharge apparatus was used for final development of two different high-speed recording systems and for measurements of the composition of the materials given off by the discharge. It was shown that intense instantaneous fluxes of neutral particles were released from the sites of electrical breakdown events. A laser micropulse mass analyzer showed that visible discoloration at breakdown sites were correllated with the presence of iron on the polymer side of the film, presumably caused by punch-through to the Inconel backing. Kapton samples irradiated by an oxygen ion beam were tested. The irradiated samples were free of surface hydrocarbon contamination but otherwise behaved in the same way as the Kapton samples tested earlier. Only the two samples exposed to oxygen ion bombardment were relatively clean. This indicates an additional variable that should be considered when testing spacecraft materials in the laboratory.

Kendall, B. R. F.↗

Precise interpretations of traditional fine-tuning measures

We uncover two precise interpretations of traditional electroweak fine-tuning (FT) measures that were historically missed. (i) a statistical interpretation : the traditional FT measure shows the change in plausibility of a model in which a parameter was exchanged for the 𝑍 boson mass relative to an untuned model in light of the 𝑍 boson mass measurement. (ii) an information-theoretic interpretation : the traditional FT measure shows the exponential of the extra information, measured in nats, relative to an untuned model that you must supply about a parameter in order to fit the 𝑍 mass. We derive the mathematical results underlying these interpretations, and explain them using examples from weak scale supersymmetry. These new interpretations allow us to rigorously define FT in particle physics and beyond, shed fresh light on the status of extensions to the Standard Model and, lastly, allow us to precisely reinterpret historical and recent studies using traditional FT measures.

electroweak symmetry breaking↗

Semiempirical method of determining flow coefficients for pitot rake mass flow rate measurements

Flow coefficients applicable to area-weighted pitot rake mass flow rate measurements are presented for fully developed, turbulent flow in an annulus. A turbulent velocity profile is generated semiempirically for a given annulus hub-to-tip radius ratio and integrated numerically to determine the ideal mass flow rate. The calculated velocities at each probe location are then summed, and the flow rate as indicated by the rake is obtained. The flow coefficient to be used with the particular rake geometry is subsequently obtained by dividing the ideal flow rate by the rake-indicated flow rate. Flow coefficients ranged from 0.903 for one probe placed at a radius dividing two equal areas to 0.984 for a 10-probe area-weighted rake. Flow coefficients were not a strong function of annulus hub-to-tip radius ratio for rakes with three or more probes. The semiempirical method used to generate the turbulent velocity profiles is described in detail.

Trefny, C. J.↗

Calibration of the Forward Scattering Spectrometer Probe used on the ER-2 during the Airborne Antarctic Ozone Experiment

The Particle Measuring Systems (PMS) Forwared Scattering Spectrometer Probe (FSSP-100) which was flown on the ER-2 during the Airborne Antarctic Ozone Experiment for the measurement of particles in polar stratospheric clouds has been evaluated and calibrated. The sample volume of the probe per 10-s sampling period increases from 257 cu cm for 1-micron particles to 412 for 15-micron particles, but there is substantial uncertainty in this value. Limitations in the measurements from this instrument and possible corrections are discussed. The uncertainty in the total particle mass measured by the probe may be as large as + or - 100 percent. Recommendations are given for the processing of data from the FSSP used in this project.

Baumgardner, Darrel↗

Estimated Environmental Exposures for MISSE-7B

This paper details the 18-month environmental exposure for Materials International Space Station Experiment 7B (MISSE-7B) ram and wake sides. This includes atomic oxygen, ultraviolet radiation, particulate radiation, thermal cycling, meteoroid/space debris impacts, and observed contamination. Atomic oxygen fluence was determined by measured mass and thickness loss of polymers of known reactivity. Diodes sensitive to ultraviolet light actively measured solar radiation incident on the experiment. Comparisons to earlier MISSE flights are discussed.

Finckenor, Miria M.↗

Measurement of Mass-Independent Perturbations of Cadmium in Nuclear Debris Samples

The isotopic composition of cadmium in nuclear debris was measured by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Mass-independent perturbations due to fission product decay on the isotopes of Cd were observed. Relative fission yields for masses 111, 112, 114 and 116 were determined in each sample of nuclear debris and compared with reported values found in irradiated plutonium and uranium fuels. Mass spectrometry measurements of the valley fission product endpoints are extremely challenging due to the low cumulative fission yields and small amounts of each isotope that are produced. To overcome these challenges, a new purification method for Cd was developed and validated by examination of a number of geological reference materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the Spatial Coherence of Magnetic Ejecta: Measurements of Coronal Mass Ejections by Multiple Spacecraft Longitudinally Separated by 0.01 au

Measurements of coronal mass ejections (CMEs) by multiple spacecraft at small radial separations but larger longitudinal separations is one of the ways to learn about the three-dimensional structure of CMEs. Here, we take advantage of the orbit of the Wind spacecraft that ventured to distances of up to 0.012 au from the Sun-Earth line during 2000-2002. Combined with measurements from the Advanced Composition Experiment, which is in a tight halo orbit around L1, the multipoint measurements allow us to investigate how the magnetic field inside magnetic ejecta (MEs) changes on scales of 0.005-0.012 au. We identify 21 CMEs measured by these two spacecraft for longitudinal separations of 0.007 au or more. We find that the time-shifted correlation between 30 minute averages of the non-radial magnetic field components measured at the two spacecraft is systematically above 0.97 when the separation is 0.008 au or less, but is on average 0.89 for greater separations. Overall, these newly analyzed measurements, combined with 14 additional ones when the spacecraft separation is smaller, point toward a scale length of longitudinal magnetic coherence inside MEs of 0.25-0.35 au for the magnitude of the magnetic field, but 0.06-0.12 au for the magnetic field components. This finding raises questions about the very nature of MEs. It also highlights the need for additional "mesoscale" multipoint measurements of CMEs with longitudinal separations of 0.01-0.2 au.

CMEs↗