Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Method and system to maintain electrolyte stability for all-iron redox flow batteries

Methods and systems are provided which maintain the positive and negative electrolyte pH and stability of a redox flow battery through the use of electrochemical rebalancing cells. The electrochemical cells may be activated by applying an electrical load to affect changes to the pH of the electrolytes. The use of the electrochemical cells improves long term performance stability redox flow batteries by decreasing and/or eliminating Fe(OH)3 precipitation formation.

25 ENERGY STORAGE↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful selection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Issues about implementation of geometry control to maintain nuclear criticality safety - 14438

The control of the geometry to establish and maintain Nuclear Criticality Safety (NCS) of a fissile unit is usually preferred by licensees and regulators since such a control is based on passive engineering and requires less operating constraints than other methods of control (mass, etc.). Nevertheless, several safety issues are associated with this method of control to ensure the geometry during all the unit lifetime, in normal and abnormal situations, from its manufacturing to its decommissioning. The first issue is to identify the dimensions defining the geometry, taking into account reflectors and mobile equipment, and the interaction conditions of the controlled unit to ensure the subcriticality. Thus, the dimensions important and to be controlled are identified in the NCS assessment. These dimensions are called Nuclear Criticality Safety Dimensions (NCSD) in this paper. Then, the second and the third issues are to define NCSD limits to be respected and to verify the compliance of the actual unit geometry with these limits at each stage of the unit life. Regarding the third issue, the challenges are the practicality of the control, its uncertainty and the management of non-compliances. Finally, the fourth issue is to properly document and record the NCSD and the compliance verification. This paper focuses on the main issues related to the implementation of geometry control on the NCS assessment and suggests advices to fulfill these challenges. (authors)

42 ENGINEERING↗

Performance Versus Maintainability: A Case Study of Scream on Frontier

The Simple Cloud-Resolving E3SM Atmosphere Model (Scream) won the inaugural ACM Gordon Bell Prize for Climate Modeling. While most of Scream is portable Kokkos code, the Gordon-Bell runs did include tuning specifically for Frontier, the exascale computer at Oak Ridge National Laboratory. Production science runs use the same high-level configuration of Scream, but the tuned kernels do not meet the software standards necessary to merge into the production code base. This work describes experiments to refactor these kernels to meet the maintainability requirements of the production Scream code base while preserving high performance.

White, Trey↗

Radiation Protection Instrument Reliability and Maintainability Data

This report is a collection of reliability and maintenance data on several types of radiation protection instrumentation. Some radiation detectors are used for personnel safety; others are used for environmental stewardship. Six types of instruments are addressed in this report. These are: continuous air monitors, tritium room air monitors, facility vent stack monitors, tritium bubbler monitors, tritium in effluent water monitors, and general purpose radiation survey meters. Literature searches, operating experience data, and occurrence reports were used to identify failure modes and to estimate quantitative failure rates for several general types of radiation protection instruments. Likewise, data on instrument repair has been found when possible and used to estimate the mean time to repair. These data can be useful for facility safety assessment, personnel safety assessment, environment assessment, and for equipment and labor planning purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Genome‐wide CRISPR‐Cas9 screen reveals a persistent null‐hyphal phenotype that maintains high carotenoid production in Yarrowia lipolytica

Abstract Yarrowia lipolytica is a metabolic engineering host of growing industrial interest due to its ability to metabolize hydrocarbons, fatty acids, glycerol, and other renewable carbon sources. This dimorphic yeast undergoes a stress‐induced transition to a multicellular hyphal state, which can negatively impact biosynthetic activity, reduce oxygen and nutrient mass transfer in cell cultures, and increase culture viscosity. Identifying mutations that prevent the formation of hyphae would help alleviate the bioprocess challenges that they create. To this end, we conducted a genome‐wide CRISPR screen to identify genetic knockouts that prevent the transition to hyphal morphology. The screen identified five mutants with a null‐hyphal phenotype— ΔRAS2 , ΔRHO5 , ΔSFL1 , ΔSNF2 , and ΔPAXIP1 . Of these hits, only ΔRAS2 suppressed hyphal formation in an engineered lycopene production strain over a multiday culture. The RAS2 knockout was also the only genetic disruption characterized that did not affect lycopene production, producing more than 5 mg L −1 OD −1 from a heterologous pathway with enhanced carbon flux through the mevalonate pathway. These data suggest that a ΔRAS2 mutant of Y. lipolytica could prove useful in engineering a metabolic engineering host of the production of carotenoids and other biochemicals.

59 BASIC BIOLOGICAL SCIENCES↗

Real‐time quantification and supplementation of bioreactor amino acids to prolong culture time and maintain antibody product quality

Abstract Real‐time monitoring of cell cultures in bioreactors can enable expedited responses necessary to correct potential batch failure perturbations which may normally go undiscovered until the completion of the batch and result in failure. Currently, analytical technologies are dedicated to real‐time monitoring of bioreactor parameters such as pH, dissolved oxygen, and temperature, nutrients such as glucose and glutamine, or metabolites such as lactate. Despite the importance of amino acids as the building blocks of therapeutic protein products, other than glutamine their concentrations are not commonly measured. Here, we present a study into amino acid monitoring, supplementation strategies, and how these techniques may impact the cell growth profiles and product quality. We used preliminary bioreactor runs to establish baselines by determining initial amino acid consumption patterns, the results of which were used to select a pool of amino acids which gets depleted in the bioreactor. These amino acids were combined into blends which were supplemented into bioreactors during a subsequent run, the concentrations of which were monitored using a mass spectrometry based at‐line method we developed to quickly assess amino acid concentrations from crude bioreactor media. We found that these blends could prolong culture life, reversing a viable cell density decrease that was leading to batch death. Additionally, we assessed how these strategies might impact protein product quality, such as the glycan profile. The amino acid consumption data were aligned with the final glycan profiles in principal component analysis to identify which amino acids are most closely associated with glycan outcomes.

Powers, David N.↗

Evolving efforts to maintain and improve XPS analysis quality in an era of increasingly diverse uses and users

Based on literature analysis, X-ray photoelectron spectroscopy (XPS) use continues to increase exponentially. This increased use is accompanied by anecdotal reports and systematic analyses indicating a growing presence of significantly flawed data analyses. Recognition of this problem within the surface analysis community has increased with an understanding that both inexperienced users and increased use of XPS outside the surface analysis community contribute to the problem. The XPS community has initiated several efforts to help address the problem, which is not unique to XPS. This paper describes some of the specific problems identified and some of the community efforts intended to address them. Here, we describe activities focused on three specific issues: (i) requests for detailed guides and protocols and bite-sized versions of information for non-experts, (ii) incomplete data and analysis reporting, and (iii) the high rate of peak fitting problems. A 2019 survey identified the need for guides, protocols, and standards to assist XPS users. One set of such guides has been published, and another is being assembled. Providing incremental bites of useful information is the goal of a series of papers on specific challenges to surface analysis with example solutions has been initiated as Notes and Insights papers in Surface and Interface Analysis. Examination of XPS-containing papers finds that information to establish the credibility and reproducibility of XPS results is often very incomplete. Unfortunately, ISO and ASTM standards require an amount of parameter reporting that seems excessive and unrealistic for many research publications. Initial approaches to develop and distribute a graded approach to parameter reporting are briefly described. Multiple efforts are underway to address the high rate of problems associated with photoelectron peak fitting. These include guides to peak fitting, guides to peak identification and fitting for specific elements, and the development of a peak fitting social network. The fitting social network is designed to facilitate interactions between new and experienced XPS users; analysts trying to fit XPS data (for publication or other reasons) can ask questions and establish dynamic conversations. Encouraging and enabling high-quality XPS analysis and reporting requires several different types of effort from all members of the surface and interface analysis community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protective spin-labeled fluorenes maintain amyloid beta peptide in small oligomers and limit transitions in secondary structure

Alzheimer's disease is characterized by the presence of extracellular plaques comprised of amyloid beta (Aβ) peptides. Soluble oligomers of the Aβ peptide underlie a cascade of neuronal loss and dysfunction associated with Alzheimer's disease. Here, single particle analyses of Aβ oligomers in solution by fluorescence correlation spectroscopy (FCS) were used to provide real-time descriptions of how spin-labeled fluorenes (SLFs; bi-functional small molecules that block the toxicity of Aβ) prevent and disrupt oligomeric assemblies of Aβ in solution. Furthermore, the circular dichroism (CD) spectrum of untreated Aβ shows a continuous, progressive change over a 24-hour period, while the spectrum of Aβ treated with SLF remains relatively constant following initial incubation. These findings suggest the conformation of Aβ within the oligomer provides a complementary determinant of Aβ toxicity in addition to oligomer growth and size. Although SLF does not produce a dominant state of secondary structure in Aβ, it does induce a net reduction in beta secondary content compared to untreated samples of Aβ. The FCS results, combined with electron paramagnetic resonance spectroscopy and CD spectroscopy, demonstrate SLFs can inhibit the growth of Aβ oligomers and disrupt existing oligomers, while retaining Aβ as a population of smaller, yet largely disordered oligomers.

59 BASIC BIOLOGICAL SCIENCES↗

Potential role of 20S proteasome in maintaining stem cell integrity of human bone marrow stromal cells in prolonged culture expansion

Highlights: Black-Right-Pointing-Pointer Prolonged culture expansion retards proliferation and induces senescence of hBMSCs. Black-Right-Pointing-Pointer Reduced 20S proteasomal activity and expression potentially contribute to cell aging. Black-Right-Pointing-Pointer MG132-mediated 20S proteasomal inhibition induces senescence-like phenotype. Black-Right-Pointing-Pointer 18{alpha}-GA stimulates proteasomal activity and restores replicative senescence. Black-Right-Pointing-Pointer 18{alpha}-GA retains differentiation without affecting stem cell characterizations. -- Abstract: Human bone marrow stromal cells (hBMSCs) could be used in clinics as precursors of multiple cell lineages following proper induction. Such application is impeded by their characteristically short lifespan, together with the increasing loss of proliferation capability and progressive reduction of differentiation potential after the prolonged culture expansion. In the current study, we addressed the possible role of 20S proteasomes in this process. Consistent with prior reports, long-term in vitro expansion of hBMSCs decreased cell proliferation and increased replicative senescence, accompanied by reduced activity and expression of the catalytic subunits PSMB5 and PSMB1, and the 20S proteasome overall. Application of the proteasome inhibitor MG132 produced a senescence-like phenotype in early passages, whereas treating late-passage cells with 18{alpha}-glycyrrhetinic acid (18{alpha}-GA), an agonist of 20S proteasomes, delayed the senescence progress, enhancing the proliferation and recovering the capability of differentiation. The data demonstrate that activation of 20S proteasomes assists in counteracting replicative senescence of hBMSCs expanded in vitro.

60 APPLIED LIFE SCIENCES↗

On the conformational stability of the smallest RNA kissing complexes maintained through two G·C base pairs

Two identical 5′GACG3′ tetra-loop motifs with different stem sequences (called H2 and H3) are found in the 5′ end region of Moloney Murine Leukemia Virus (MMLV) genomic RNA. They play important roles in RNA dimerization and encapsidation through two identical tetra-loops (5′GACG3′) forming a loop-to-loop kissing complex, the smallest RNA kissing complex ever found in nature. We examined the effects of a loop-closing base pair as well as a stem sequence on the conformational stability of the kissing complex. UV melting analysis and gel electrophoresis were performed on eight RNA sequences mimicking the H2 and H3 hairpin tetra-loops with variation in loop-closing base pairs. Our results show that changing the loop-closing base pair from the wildtype (5′A·U3′ for H3, 5′U·A3′ for H2) to 5′G·C3’/5′C·G3′ has significant effect on the stability of the kissing complexes: the substitution to 5′C·G3′ significantly decreases both thermal and mechanical stability, while switching to the 5′G·C3′ significantly increases the mechanical stability only. The kissing complexes with the wildtype loop-closing base pairs (5′A·U3′ for H3 and 5′U·A3′ for H2) show different stability when attached to a different stem sequence (H2 stem vs. H3 stem). This suggests that not only the loop-closing base pair itself, but also the stem sequence, affects the conformational stability of the RNA kissing complex. - Highlights: • Thermodynamic parameters of the smallest RNA kissing interactions were measured. • The effects of loop-closing base pairs on the RNA kissing complex was investigated. • Changing the base pair to 5′CG3′ decreases the stability of the kissing complex. • Changing it to 5′GC3′ increases the mechanical resilience of the kissing complex. • Difference in its stem sequence also affects the stability of the kissing complex.

60 APPLIED LIFE SCIENCES↗