Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

General strategy for the protection of organs at risk in IMRT therapy of a moving body

We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the interplay effect when using RapidArc to treat targets moving in the craniocaudal or right-left direction

Purpose: We have investigated the dosimetric errors caused by the interplay between the motions of the LINAC and the tumor during the delivery of a volume modulated arc therapy treatment. This includes the development of an IMRT QA technique, applied here to evaluate RapidArc plans of varying complexity. Methods: An IMRT QA technique was developed, which involves taking a movie of the delivered dose (0.2 s frames) using a 2D ion chamber array. Each frame of the movie is then moved according to a respiratory trace and the cumulative dose calculated. The advantage of this approach is that the impact of turning the beam on at different points in the respiratory trace, and of different types of motion, can be evaluated using data from a single irradiation. We evaluated this technique by comparing with the results when we actually moved the phantom during irradiation. RapidArc plans were created to treat a 62 cc spherical tumor in a lung phantom (16 plans) and a 454 cc irregular tumor in an actual patient (five plans). The complexity of each field was controlled by adjusting the MU (312-966 MU). Each plan was delivered to a phantom, and a movie of the delivered dose taken using a 2D ion chamber array. Patient motion was modeled by shifting each dose frame according to a respiratory trace, starting the motion at different phases. The expected dose distribution was calculated by blurring the static dose distribution with the target motion. The dose error due to the interplay effect was then calculated by comparing the delivered dose with the expected dose distribution. Peak-to-peak motion of 0.5, 1.0, and 2.0 cm in the craniocaudal and right-left directions, with target periods of 3 and 5 s, were evaluated for each plan (252 different target motion/plan combinations). Results: The daily dose error due to the interplay effect was less than 10% for 98.4% of all pixels in the target for all plans investigated. The percentage of pixels for which the daily dose error could be larger than 5% increased with increasing plan complexity (field MU), but was less than 15% for all plans if the motion was 1 cm or less. For 2 cm motion, the dose error could be larger than 5% for 40% of pixels, but was less than 5% for more than 80% of pixels for MU<550, and was less than 10% for 99% of all pixels. The interplay effect was smaller for 3 s periods than for 5 s periods. Conclusions: The interplay between the motions of the LINAC and the target can result in an error in the delivered dose. This effect increases with plan complexity, and with target magnitude and period. It may average out after many fractions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Moving target irradiation with fast rescanning and gating in particle therapy

Purpose: In moving target irradiation with pencil beam scanning, the interplay effect between the target motion and the scanned beam is a problem because this effect causes over or under dosage in the target volume. To overcome this, we have studied rescanning using a gating technique. Methods: A simulation and experimental study was carried out. In the experiment, we used the fast scanning system developed at the HIMAC to verify the validity of phase controlled rescanning method, in which the time for rescanning irradiation of each slice is matched to the gating duration. Results: Simulation and experimental results showed that controlling the scan speed to match the respiration cycle with rescans can deliver the blurred dose distribution. In the comparison between the static measurements and the moving measurements with the phase controlled rescanning method, the dose difference was less than 2% for pinpoint chambers in the target volume. Conclusions: The simulation and experimental results demonstrated that the phase controlled rescanning method makes it possible to deliver the dose distribution close to the expected one. As an experimental result for 3D irradiation, it was estimated that blurring by the probability density function was not only for a lateral distribution, but also for a distal distribution, even in the lateral rescanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-E-18A-11: Fluoro-Tomographic Images From Projections of On-Board Imager (OBI) While Gantry Is Moving

Purpose: A method to generate a series of fluoro-tomographic images (FTI) of the slice of interest (SOI) from the projection images of the On-board imager (OBI) while gantry is moving is developed and tested. Methods: Tomographic image via background subtraction, TIBS has been published by our group. TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). We extended the idea to 4D TIBS, which enables to generate from the projection of different gantry angles. A set of background images for different angles are prepared. A background image at a given gantry angle is subtracted from the projection image at the same angle to generate a TIBS image. Then the TIBS image is converted to a reference angle. The 4D TIBS is the set of TIBS that originated from gantry angles other than the reference angle. Projection images of lung patients for CBCT acquisition are used to test the 4D TIBS. Results: Fluoroscopic images of a coronal plane of lung patients are acquired from the CBCT projections at different gantry angles and times. Change of morphology of hilar vessels due to breathing and heart beating are visible in the coronal plane, which are generated from the set of the projection images at gantry angles other than antero-posterior. Breathing surrogate or sorting process is not needed. Unlike tomosynthesis, FTI from 4D TIBS maintains the independence of each of the projections thereby reveals temporal variations within the SOI. Conclusion: FTI, fluoroscopic imaging of a SOI with x-ray projections, directly generated from the x-ray projection images at different gantry angles is tested with a lung case and proven feasible. This technique can be used for on-line imaging of moving targets. NIH Grant R01CA133539.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-D-304-01: Development of An Applicator for Treating Shallow and Moving Tumors with Respiratory-Gated Spot-Scanning Proton Therapy Using Real-Time Image Guidance

Purpose: To develop a method for treating shallow and moving tumors (e.g., lung tumors) with respiratory-gated spot-scanning proton therapy using real-time image guidance (RTPT). Methods: An applicator was developed which can be installed by hand on the treatment nozzle. The mechanical design was considered such that the Bragg peaks are placed at the patient surface while a sufficient field of view (FOV) of fluoroscopic X-rays was maintained during the proton beam delivery. To reduce the treatment time maintaining the robustness of the dose distribution with respect to motion, a mini-ridge filter (MRF) was sandwiched between two energy absorbers. The measurements were performed to obtain a data for beam modeling and to verify the spot position-invariance of a pencil beam dose distribution. For three lung cancer patients, treatment plans were made with and without the MRF and the effects of the MRF were evaluated. Next, the effect of respiratory motion on the dose distribution was investigated. Results: To scan the proton beam over a 14 x 14 cm area while maintaining the φ16 cm of fluoroscopic FOV, the lower face of the applicator was set 22 cm upstream of the isocenter. With an additional range variance of 2.2 mm and peak-to-peak distance of 4 mm of the MRF, the pencil beam dose distribution was unchanged with the displacement of the spot position. The quality of the treatment plans was not worsened by the MRF. With the MRF, the number of energy layers was reduced to less than half and the treatment time by 26–37%. The simulation study showed that the interplay effect was successfully suppressed by respiratory-gating both with and without MRF. Conclusions: The spot-scanning proton beam was successfully delivered to shallow and moving tumors within a sufficiently short time by installing the developed applicator at the RTPT nozzle.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-04: An Inter-Projection Sensor Fusion (IPSF) Approach to Estimate Missing Projection Signal in Synchronized Moving Grid (SMOG) System

Purpose: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution to this issue is acquiring 2 complimentary projections at each position, which increases scanning time. This study reports our first Result using an inter-projection sensor fusion (IPSF) method to estimate missing projection in our prototype SMOG-based CBCT system. Methods: An in-house SMOG assembling with a 1:1 grid of 3 mm gap has been installed in a CBCT benchtop. The grid moves back and forth in a 3-mm amplitude and up-to 20-Hz frequency. A control program in LabView synchronizes the grid motion with the platform rotation and x-ray firing so that the grid patterns for any two neighboring projections are complimentary. A Catphan was scanned with 360 projections. After scatter correction, the IPSF algorithm was applied to estimate missing signal for each projection using the information from the 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was applied to reconstruct CBCT images. The CBCTs were compared to those reconstructed using normal projections without applying the SMOG system. Results: The SMOG-IPSF method may reduce image dose by half due to the blocked radiation by the grid. The method almost completely removed scatter related artifacts, such as the cupping artifacts. The evaluation of line pair patterns in the CatPhan suggested that the spatial resolution degradation was minimal. Conclusion: The SMOG-IPSF is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-563: Delivered Dose Reconstruction of Moving Targets for Gated Volumetric Modulated Arc Therapy (VMAT)

Purpose: Actual delivered dose of moving tumors treated with gated volumetric arc therapy (VMAT) may significantly differ from the planned dose assuming static target. In this study, we developed a method which reconstructs actual delivered dose distribution of moving target by taking into account both tumor motion and dynamic beam delivery of gated VMAT, and applied to abdominal tumors. Methods: Fifteen dual-arc VMAT plans (Eclipse, Varian Medical Systems) for 5 lung, 5 pancreatic, and 5 liver cancer patients treated with gated VMAT stereotactic body radiotherapy (SBRT) were studied. For reconstruction of the delivered dose distribution, we divided each original arc beam into control-point-wise sub-beams, and applied beam isocenter shifting to each sub-beam to reflect the tumor motion. The tumor positions as a function of beam delivery were estimated by synchronizing the beam delivery with the respiratory signal which acquired during treatment. For this purpose, an in-house program (MATLAB, Mathworks) was developed to convert the original DICOM plan data into motion-involved treatment plan. The motion-involved DICOM plan was imported into Eclipse for dose calculation. The reconstructed delivered dose was compared to the plan dose using the dose coverage of gross tumor volume (GTV) and dose distribution of organs at risk (OAR). Results: The mean GTV dose coverage difference between the reconstructed delivered dose and the plan dose was 0.2 % in lung and pancreas cases, and no difference in liver cases. Mean D1000cc of ipsilateral lungs was reduced (0.8 ± 1.4cGy). Conclusion: We successfully developed a method of delivered dose reconstruction taking into account both respiratory tumor motion and dynamic beam delivery, and applied it to abdominal tumors treated with gated VAMT. No significant deterioration of delivered dose distribution indicates that interplay effect would be minimal even in the case of gated SBRT. This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (No. 2015038710)

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP3-01: A Model of Baseline Shift to Improve Robustness of Proton Therapy Treatments of Moving Tumors

Purpose: The shift in mean position of a moving tumor also known as “baseline shift”, has been modeled, in order to automatically generate uncertainty scenarios for the assessment and robust optimization of proton therapy treatments in lung cancer. Methods: An average CT scan and a Mid-Position CT scan (MidPCT) of the patient at the planning time are first generated from a 4D-CT data. The mean position of the tumor along the breathing cycle is represented by the GTV contour in the MidPCT. Several studies reported both systematic and random variations of the mean tumor position from fraction to fraction. Our model can simulate this baseline shift by generating a local deformation field that moves the tumor on all phases of the 4D-CT, without creating any non-physical artifact. The deformation field is comprised of normal and tangential components with respect to the lung wall in order to allow the tumor to slip within the lung instead of deforming the lung surface. The deformation field is eventually smoothed in order to enforce its continuity. Two 4D-CT series acquired at 1 week of interval were used to validate the model. Results: Based on the first 4D-CT set, the model was able to generate a third 4D-CT that reproduced the 5.8 mm baseline-shift measured in the second 4D-CT. Water equivalent thickness (WET) of the voxels have been computed for the 3 average CTs. The root mean square deviation of the WET in the GTV is 0.34 mm between week 1 and week 2, and 0.08 mm between the simulated data and week 2. Conclusion: Our model can be used to automatically generate uncertainty scenarios for robustness analysis of a proton therapy plan. The generated scenarios can also feed a TPS equipped with a robust optimizer. Kevin Souris, Ana Barragan, and Dario Di Perri are financially supported by Televie Grants from F.R.S.-FNRS.

60 APPLIED LIFE SCIENCES↗

Collapse and revival of the Doppler-Rabi oscillations of a moving atom in a cavity

Collapse and revival of the Doppler-Rabi oscillations of a two-level atom moving in a cavity electromagnetic field are analyzed. The coupled atom-field dynamics are predicted accurately by numerical calculation and approximately by using the stationary phase approximation combined with the Poisson summation formula. The collapse and revival patterns are shown to be qualitatively different in the cases of moving atom and atom at rest. In particular, quantum revivals of Doppler-Rabi oscillations occur with a period determined by the Doppler shift of the atomic transition frequency. This regime of Doppler-Rabi oscillations requires that the Rabi frequency and the Doppler shift satisfy the condition {omega}{sub R} << {omega}{sub D}. Under the inverse relation, the collapse- revival phenomenon generally does not occur. It is shown that even a small amount of atom-cavity detuning eliminates collapse-revival behavior. The analysis is performed for both coherent and thermal cavity fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Stefan problem of solidification of ternary systems in the presence of moving phase transition regions

The process of solidification of ternary systems in the presence of moving phase transition regions has been investigated theoretically in terms of the nonlinear equation of the liquidus surface. A mathematical model is developed and an approximate analytical solution to the Stefan problem is constructed for a linear temperature profile in two-phase zones. The temperature and impurity concentration distributions are determined, the solid-phase fractions in the phase transition regions are obtained, and the laws of motion of their boundaries are established. It is demonstrated that all boundaries move in accordance with the laws of direct proportionality to the square root of time, which is a general property of self-similar processes. It is substantiated that the concentration of an impurity of the substance undergoing a phase transition only in the cotectic zone increases in this zone and decreases in the main two-phase zone in which the other component of the substance undergoes a phase transition. In the process, the concentration reaches a maximum at the interface between the main two-phase zone and the cotectic two-phase zone. The revealed laws of motion of the outer boundaries of the entire phase transition region do not depend on the amount of the components under consideration and hold true for crystallization of a multicomponent system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Moving branes in the presence of background tachyon fields

We compute the boundary state associated with a moving Dp-brane in the presence of the open string tachyon field as a background field. The effect of the tachyon condensation on the boundary state is discussed. It leads to a boundary state associated with a lower-dimensional moving D-brane or a stationary instantonic D-brane. The former originates from condensation along the spatial directions and the latter comes from the temporal direction of the D-brane worldvolume. Using the boundary state, we also study the interaction amplitude between two arbitrary Dp{sub 1}- and Dp{sub 2}-branes. The long-range behavior of the amplitude is investigated, demonstrating an obvious deviation from the conventional form, due to the presence of the background tachyon field.

79 ASTRONOMY AND ASTROPHYSICS↗

Transition radiation emitted by a particle moving along the axis of a perfectly conducting conical surface

The spatial field distribution is determined for the transition radiation emitted by a relativistic particle moving along the axis of a perfectly conducting circular conical surface with a fixed apex. Emission from particles moving away from and towards the apex is examined. Expressions are obtained that can be used to calculate the angular distribution of radiation intensity for various apex angles between 0 and {pi}. Significant differences are demonstrated between the spatial distributions of radiation generated by outgoing and incoming particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of metallic surface microroughness on the probability and spectrum of plasmon excitation by a fast charged particle moving parallel to the surface

The Green's function of the electric field of plasmons is determined in a semi-infinite medium with an abrupt plasma boundary where nonequilibrium conduction electrons either undergo elastic reflection from the boundary or 'stick' to it and give rise to a stationary surface charge. The angular reflection of elastically scattered electrons can be either specular or diffuse. The Green's function is used to find the singleevent spectrum of energy loss by a fast electron moving parallel to the boundary. The effect of electronboundary scattering parameters on the structure of bulk and surface plasmon resonances is analyzed. The probability of transition radiation of bulk plasmon by an electron moving in vacuum is examined. A new type of surface resonance is found under conditions of perfectly elastic scattering of conduction electrons from the plasma boundary, similar in structure to a tangential surface plasmon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Properties of Moving Discrete Breathers in Beryllium

Discrete breathers (DBs) have been described among pure metals with face-centered cubic (FCC) and body-centered cubic (BCC) lattice, but for hexagonal close-packed (HCP) metals, their properties are little studied. In this paper, the properties of standing and moving DBs in beryllium HCP metal are analyzed by the molecular dynamics method using the many-body interatomic potential. It is shown that the DB is localized in a close-packed atomic row in the basal plane, while oscillations with a large amplitude along the close-packed row are made by two or three atoms, moving in antiphase with the nearest neighbors. Dependences of the DB frequency on the amplitude, as well as the velocity of the DB on its amplitude and on parameter δ, which determines the phase difference of the oscillations of neighboring atoms, are obtained. The maximum velocity of the DB movement in beryllium reaches 4.35 km/s, which is 33.7% of the velocity of longitudinal sound waves. The obtained results supplement our concepts about the mechanisms of localization and energy transport in HCP metals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method of Moving Asymptotes Optimization Algorithm in Python

Python implementation of the Method of Moving Asymptotes optimization algorithm described in[Svanberg, K., The method of moving asymptotes- a new method for structural optimization. International journal for numerical methods in engineering, 1987. 24(2): p.359 (https://onlinelibrary.wiley.com/doi/abs/10.1002/nme.1620240207). Originally implemented in[GetDP](https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=717799) [project](https://gitlab.onelab.info/getdp/getdp), although it has been deleted in their repository.

Salazar De Troya, Miguel↗

Multi-modal Free-moving Data Fusion (MFDF) v1.0

Multi-modal Free-moving Data Fusion (MFDF) is a python package that implements low and high-level functionality for performing qualitative and quantitative gamma-ray imaging analyses. Such analyses enable the use of gamma-ray spectrometers and/or imagers to estimate the distribution and quantity of radiological materials in an environment. Free-moving 3D imaging requires additional information about the 3D trajectory and orientation of the system, however all of these methods can be applied to 2D static gamma-ray imaging as well. The package includes methods (MLEM and MAP) for distributed source reconstruction, methods (PSL) for point source reconstruction, the ability to ingest and utilize quantitative detector response functions (for absolute analyses), and the ability to perform 3D estimation of dose-rates from quantitative reconstructions.

Joshi, Tenzing↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗