Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The materials science X-ray beamline BL8 at the DELTA storage ring

The instrumentation of the hard X-ray beamline BL8 at the 1.5 GeV Dortmund Electron Accelerator DELTA is described, and the properties of the X-ray optical elements are presented together with experimental data of different fields of research. The beamline, which makes use of the photons emitted by a superconducting asymmetric wiggler, is dedicated to X-ray studies--especially X-ray absorption spectroscopy (XAS)--in the spectral range from about 1 keV to ca. 25 keV photon energy using three different monochromators, namely YB{sub 66}(400), Si(111) and Si(311). The endstation comprises a 6-axis diffractometer that is capable of carrying heavy loads related to non-ambient sample environments such as high pressure cells, cryostats or even complete ultrahigh vacuum systems. X-ray absorption spectra from several reference compounds illustrate the performance of the beamline optics concerning e.g. energy range, energy resolution and beam stability. Fluorescence detection enables the investigation of dilute sample systems, and surface sensitive reflection mode experiments are possible for thin film studies.

36 MATERIALS SCIENCE↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Performance of Saga-University Beamline with Planer Undulator

A planer undulator consisted of 24 periods of an 85-mm length has been installed in a 2.7-m straight section of the SAGA-LS, in order to provide brilliant soft x-rays for advanced researches on nano-surfaces and interfaces at the Saga-university beamline BL13. The photon flux of 2x10{sup 11} photons/100 mA was obtained at 133 eV, and the available photon energy was beyond 800 eV using higher harmonics. The achieved resolving power of the varied-line-spacing (VLS) monochromator system was 8,670 at 130 eV with slits of 15 um. This agrees very well with the value of 8,790 expected from the ray-tracing calculation. The details in the performance tests will be reported, indicating the high performance of the beamline BL13 for photoelectron spectroscopy in the soft x-ray region.

43 PARTICLE ACCELERATORS↗

The New Structural Materials Science Beamlines BL8A and 8B at Photon Factory

BL8A and 8B are new beamlines for structural materials science at Photon Factory. The primary characteristics of both beamlines are similar. The incident beam is monochromatized by the Si(111) double-flat crystal monochromator and focused at the sample position by a Rh-coated bent cylindrical quartz mirror. The Weissenberg-camera-type imaging-plate (IP) diffractometers were installed. The X-ray diffraction experiments for structural studies of strongly correlated materials, such as transition metals, molecular conductors, endohedral fullerenes, nano-materials, etc, are conducted at these stations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Design of VLS-PGM Soft X-Ray Beamline on Indus-2

The optical design of a soft x-ray beamline on the bending magnet of Indus-2 synchrotron source is presented. A Varied Line Spacing Plane Grating Monochromator (VLS-PGM) was adopted with Hettrick type optics. The VLS-PGM consists of a spherical mirror and three interchangeable gratings of line densities 1200 l/mm, 400 l/mm and 150 l/mm to efficiently cover the energy region 50-1500 eV. The VLS groove parameters were obtained by minimizing defocus aberration, coma and spherical aberration. The overall performance of the beamline was estimated by detailed raytracing calculations. The beamline design, results of the raytracing calculations and the expected performances are presented.

43 PARTICLE ACCELERATORS↗

A Beamline for Fast Polarization Switching at NSLS-II

The first XUV beamline (200-2000 eV) at NSLS-II will have two branches, one optimized for photon hungry experiments requiring high coherent flux and one optimized for studies of polarization sensitive materials and interfaces based on fast polarization switching. We describe here the branch designed for fast polarization switching with frequencies up to 1 kHz, high photon flux, and good energy resolution. The beamline will be served by two canted undulators and is based on the focusing variable line spacing grating monochromator. The two beams will be focused at the same spot of approximately 80x10 {mu}m (hor.xver.). The expected circular polarized flux at the sample from each device up to 1.4 keV will be higher than 10{sup 12} photons/s at a resolving power better than 10{sup 4}. An additional KB focusing system will deliver the two beams to a spot in the {mu}m range.

43 PARTICLE ACCELERATORS↗

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

Optimization of Cylindrical Bent Crystals with Small Radius

To minimize the anticlastic curvature and lower the breaking risk of a sagittal bent crystal with a smaller bending radius, three types of crystal models including the stiffening ribs, the golden value and the assembly with metal were discussed in this paper. Overall structures of the models were predicted and the parameters were optimized by the finite element analysis method. Compared with the results of measurement by long-trace-profiler, theoretical calculations were in good agreed with practical tests. The single-crystal silicon strips glued on the titanium is preferred for the second crystal of the sagittal focusing monochromator at the NSRL-XAFS beamline. Because it not only minimizes the anticlastic distortion but also it achieves small radius less than one meter.

43 PARTICLE ACCELERATORS↗

Construction of a New VUV/Soft X-ray Undulator Beamline BL-13A in the Photon Factory for Study of Organic Thin Films and Biomolecules Adsorbed on Surfaces

A planar undulator beamline, BL-13A, covering 30-1,000 eV has been constructed in the Photon Factory. The main scientific targets are investigations of organic thin films and biomolecules adsorbed on well-defined surfaces using angle-resolved photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy. A variable-included-angle Monk-Gillieson mounting monochromator with varied-line-spacing plane gratings is used to achieve a high photon flux of 10{sup 10}-10{sup 12} photons/s with a high resolution (E/{Delta}E) of 7,000-30,000. A typical spot size on the sample position is estimated to be 130 {mu}m (horizontal)x40 {mu}m (vertical). After commissioning, BL-13A will be open for users from January 2010.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

High-performance soft x-ray spectromicroscopy beamline at SSRF

The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.

43 PARTICLE ACCELERATORS↗

Construction and testing of the instrument for neutron holographic study at the Budapest Research Reactor

Neutron scattering device dedicated to neutron holography experiments is described. The device is operating at a constant wavelength prepared by a double focusing monochromator. It is equipped by highly efficient shielding, proper collimator, Eulerian cradle, monitor detector, gamma-ray, and neutron detectors as well. Relevant software serves as control for the measurement and data collection. The harmonized application of the components enumerated above makes our device extremely efficient and unparalleled. Two atomic resolution neutron holographic experiments carried out illustrate the efficiency and power of the instrument.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optical sensor for measuring American Lobster vitality

The vitality of the American Lobster (Homarus americanus) is correlated to the total hemolymph protein (THP) in lobster hemolymph (blood). The standard technique for determining lobster vitality is to draw blood from a lobster and measure THP with a refractometer. This technique is invasive and endangers the lobster's health since blood must be drawn from the lobster. In the present work an optical sensor is developed to measure a lobster's vitality in vivo. It is comprised of a broadband light source, a monochromator, a fiber optic reflection probe, a spectrometer and a computer. This sensor measures protein concentrations by exciting a lobster with 280 nm and 334 nm wavelength light sources and measuring the corresponding absorbance peaks for THP and the fluorescence peak for hemocyanin (Hc), the majority protein in hemolymph. In this work several lobsters are tested. For each lobster, absorbance and fluorescence peaks are measured using the sensor and compared to protein concentrations measured using a refractometer. It is found that the shell thickness and muscle density, which correspond directly to protein concentration and the molting stage of the lobster have a significant effect on the absorbance and fluorescence measurements. It is also found that within specific molting stages, such as pre-molt and post-molt, protein concentration measured with a refractometer correlates linearly to absorbance and fluorescence measurements with the optical sensor.

60 APPLIED LIFE SCIENCES↗

Femtosecond time-resolved photoelectron spectroscopy with a vacuum-ultraviolet photon source based on laser high-order harmonic generation

A laser-based tabletop approach to femtosecond time-resolved photoelectron spectroscopy with photons in the vacuum-ultraviolet (VUV) energy range is described. The femtosecond VUV pulses are produced by high-order harmonic generation (HHG) of an amplified femtosecond Ti:sapphire laser system. Two generations of the same setup and results from photoelectron spectroscopy in the gas phase are discussed. In both generations, a toroidal grating monochromator was used to select one harmonic in the photon energy range of 20-30 eV. The first generation of the setup was used to perform photoelectron spectroscopy in the gas phase to determine the bandwidth of the source. We find that our HHG source has a bandwidth of 140 {+-} 40 meV. The second and current generation is optimized for femtosecond pump-probe photoelectron spectroscopy with high flux and a small spot size at the sample of the femtosecond probe pulses. The VUV radiation is focused into the interaction region with a toroidal mirror to a spot smaller than 100 x 100 {mu}m{sup 2} and the flux amounts to 10{sup 10} photons/s at the sample at a repetition rate of 1 kHz. The duration of the monochromatized VUV pulses is determined to be 120 fs resulting in an overall pump-probe time resolution of 135 {+-} 5 fs. We show how this setup can be used to map the transient valence electronic structure in molecular dissociation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source

We report commissioning of the microprobe-XRF beamline on Indus-2 synchrotron source. The beamline has been recently made operational and is now open for the user's experiments. The beamline comprises of Si(111) double crystal monochromator and Kirkpatrick-Baez focusing optics. The beamline covers wide photon energy range of 4 - 20 keV using both collimated and micro-focused beam modes. The design details and the first commissioning results obtained using this beamline are presented.

43 PARTICLE ACCELERATORS↗

Application of multilayer mirror for harmonic analysis in soft X-ray region

Order contamination in soft x-ray beamline is a severe problem which poses difficulty in various analysis techniques. Generally grating analyzer is used to estimate the higher order contribution where poor knowledge of wall and land roughness contribution makes it difficult to get theoretical fit and so analysis gives qualitative estimation only. Here we demonstrate the application of multilayer mirror for accurate determination of order contamination in Toroidal grating monochromator (TGM) at reflectivity beamline of Indus-1. We used a Mo/Si multilayer of d{approx}100Aa period to quantify 2{sup nd} and 3{sup rd} order composition to identify order contamination below 0.5% or better.

43 PARTICLE ACCELERATORS↗