Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-01: BEST IN PHYSICS (THERAPY): -Field-Induced Dose Effects in a Mouse Lung Phantom: Monte Carlo and Experimental Assessments

Purpose: To simulate and measure magnetic-field-induced radiation dose effects in a mouse lung phantom. This data will be used to support pre-clinical experiments related to MRI-guided radiation therapy systems. Methods: A mouse lung phantom was constructed out of 1.5×1.5×2.0-cm{sup 3} lung-equivalent material (0.3 g/cm{sup 3}) surrounded by a 0.6-cm solid water shell. EBT3 film was inserted into the phantom and the phantom was placed between the poles of an H-frame electromagnet. The phantom was irradiated with a cobalt-60 beam (1.25 MeV) with the electromagnet set to various magnetic field strengths (0T, 0.35T, 0.9T, and 1.5T). These magnetic field strengths correspond to the range of field strengths seen in MRI-guided radiation therapy systems. Dose increases at the solid-water-to-lung-interface and dose decreases at the lung-to-solid-water interface were compared with results of Monte Carlo simulations performed with MCNP6. Results: The measured dose to lung at the solid-water-to-lung interface increased by 0%, 16%, and 29% with application of the 0.35T, 0.9T, and 1.5T magnetic fields, respectively. The dose to lung at the lung-to-solid-water interface decreased by 4%, 18%, and 24% with application of the 0.35T, 0.9T, and 1.5T magnetic fields, respectively. Monte Carlo simulations showed dose increases of 0%, 16%, and 31% and dose decreases of 4%, 16%, and 25%. Conclusion: Only small dose perturbations were observed at the lung-solid-water interfaces for the 0.35T case, while more substantial dose perturbations were observed for the 0.9T and 1.5T cases. There is good agreement between the Monte Carlo calculations and the experimental measurements (within 2%). These measurements will aid in designing pre-clinical studies which investigate the potential biological effects of radiation therapy in the presence of a strong magnetic field. This work was partially funded by Elekta.

60 APPLIED LIFE SCIENCES↗

COSUBS

COSUBS (COrrelated Sampling Using Batch Statistics) reads MCNP6 output files and propagates the statistical uncertainties of various combinations of tallies using batch statistics, accounting for correlations.

Favorite, Jeffrey↗

sinbad-dt-source

MCNP6 source subroutine for simulating D-T neutrons in Ti-T Target

Armstrong, Jerawan [Los Alamos National Laboratory↗

Comparative analysis of energy deposition modes available in Serpent 2 within the framework of the supercritical water reactor - Fuel qualification test reactor physics benchmark

A joint European Canadian Chinese development of a supercritical water-cooled small modular reactor (SCW-SMR) technology is in progress since September 2020 in the framework of a Horizon 2020 project called ECC-SMART. As a main purpose of the project, proper estimates of energy deposition and its spatial distribution are prerequisites for the accurate analysis of safety related parameters of the SCW-SMR concept under development. A supercritical water reactor fuel computational benchmark model, provided by Canadian Nuclear Laboratories, was applied for detailed comparison of different energy deposition calculation options available in the Serpent 2 Monte Carlo code. The effect of energy deposition options on the normalization of the results as well as on the spatial distribution of the energy deposition are discussed. Consistent energy deposition calculation methods are presented between three Monte Carlo codes, viz., Serpent 2, MCNP6 and OpenMC. Although resource-intensive, the use of the coupled neutron-photon transport mode of Serpent 2 is recommended for accurate spatial and quantitative characterization of energy deposition in the SCW-SMR fuel assemblies, accounting for both neutron and photon heating of all the materials. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark evaluation of one dimensional array of HEU moderated and reflected by Lucite

The evaluation of two HEU-Lucite experiments is presented. The critical experiments were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. In these experiments, HEU foils were interleaved with Lucite in a column stack and were moderated and reflected from the square Lucite plates. The neutron data produced were used to approximate the multiplication of each measured configuration. The evaluation of the experiments using calculational techniques is presented in the paper. A Monte-Carlo computational model to be used with MCNP6 was developed for the determination of uncertainties and the effects of various uncertainties on the multiplication factor were studied. The evaluation of the benchmark was performed for comparison of calculation results with the experimental data and validation of calculation techniques in particular the newly available thermal scattering data for the Lucite material. The sensitivity studies include parametric variations of material composition and geometry. Experimental uncertainties were low, with the overall height of the HEU/Lucite stack being the largest contributor to the overall uncertainty in k{sub eff}. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative study of decay heat calculations with FLUKA and MCNP/CINDER2008

In designing a high-power tungsten target, decay heat driven temperature rise in the spallation volume is a safety concern during maintenance and in loss of coolant accidents. As tungsten hydrates and becomes volatile in steam at above 800 ◦C, it is important to keep the target temperature below this threshold when active cooling is unavailable. Decay heat in a target is calculated with particle transport simulation codes combined with transmutation codes. The calculated decay heat usually differs depending on the nuclear cross sections and the decay particle transport models built in the code architecture. In this paper, we calculated decay heat of a water-cooled tungsten target using popular particle transport codes, FLUKA and MCNP6® paired with CINDER2008 and compared the results. The target-moderator-reflector (TMR) system is modeled with a water-cooled solid tungsten target, water premoderators, liquid hydrogen cold moderators and beryllium reflectors. Water-cooled stainless-steel shielding is modeled around the TMR system. The tungsten volume is clad with a thin layer of erosion/corrosion resistant material. This study provides information about the uncertainty range in decay heat prediction of high-power spallation targets for hazard analysis.

Lee, Yong Joong↗

IER-163 Post-Experiment MCNP Calculations (U)

IER-163 has been modeled with high fidelity in MCNP6. The model k eff was high, as in other similar calculations. The fission ratio 238 U(n,f)/ 235 U(n,f) was 12.6% too small compared with measurements; the ratio 239 Pu(n,f)/ 235 U(n,f) was 11.5% too small compared with measurements; the iridium ratio 193 Ir(n,n´)/ 191 Ir(n,γ) was 16.4% too large; and the gold ratios 197 Au(n,2n)/ 197 Au(n,γ), 197 Au(n,2n)/ 235 U(n,f), and 197 Au(n,γ)/ 235 U(n,f) were within one standard deviation of the measured values. It is suggested that the calculated 235 U fission rate is too large and the calculated 238 U fission rate is too small.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MCNP Simulations of Material Exposure Experiments (U)

Simulations of proposed material exposure experiments were performed using MCNP6. The experiments will expose ampules containing different materials of interest with radiation to observe the chemical breakdown of the materials. Simulations were performed to map out dose in materials as a function of distance from the source, dose variation between materials, dose variation due to ampule orientation, and dose variation due to different source energy. This write up is an overview of the simulations and will provide guidance on how to use the data in the spreadsheet.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MODEX ─ A Program for Calculation of the Energy Spectra of Particle Emitted in the Reactions of Pre-Equilibrium and Equilibrium Statistical Decays

The program is described intended for calculation of the energy distribution of particles, emitted by excited nucleus, using the Modified Exciton Model (MEM). The complete text of the program is presented in FORTRAN66 language. We reproduce here this 1974 JINR Communication as it was never published in a journal but it represents a historical interest as the first (in the world) Monte Carlo realization of the preequilibrium plus evaporation model, and was and still is used in dozens of countries all over the world. E.g., the current CEM03.03 and LAQGSM03.03 event-generators of the latest LANL Monte Carlo transport code MCNP6 have today modified parts from MODEX, the first Monte Carlo preequilibrium code in the world. [Abstract is in English. The 1974 JINR Communication is in Russian.]

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Listing of Available ACE Data Tables

This document is divided into multiple sections. Section 2 lists some of the more frequently used ENDF/B reaction types that can be used with the FM input card. The remaining sections (described below) contain tables showing the available ACE data tables for various types of data. These ACE data libraries are distributed by the Radiation Safety Information Computational Center (RSICC) with MCNP6.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proposed ACE Covariance Format (Version 1.0)

A new ACE format for covariance data is proposed. Rather than storing an upper triangular matrix, the principal eigenvalues and eigenvectors of the matrix for an isotope are stored. The eigenvectors are used by MCNP6 to reconstruct an approximate covariance matrix. The matrix consists of blocks corresponding to ZA/MT pairs. Each block uses the same unionized energy grid. The information is stored into a contiguous block of information in an array called XSS. The array JXS(.,ISOTOPE) gives the pointer to the start of the covariance block for that isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eigenfunction Decomposition of Reactor Perturbations and Transitions Using MCNP Monte Carlo

Monte Carlo criticality calculations for nuclear reactors have typically only been able to find the primary eigenvalue and eigenmode. With the new fission matrix capability in MCNP6, it becomes possible to solve for higher modes, which are useful in wide variety of analyses. As a test case of this new capability, two reactor models in both a base configuration and a perturbed configuration were simulated in MCNP to generate fission matrices. Tools were written to find a relatively small number of eigenpairs of the resulting matrices, whereupon it was found that the implicitly restarted Arnoldi method outperformed the previously used power iteration as an eigenvalue algorithm by a factor of 1500 for a 3600 × 3600 sparse matrix.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Higher-Mode Applications of Fission Matrix Capability for MCNP

In this work, the fission matrix method, implemented into MCNP6, is used to study criticality calculations and compute quantities of practical use. Physically, the fission matrix consists of spatial transition terms between two fission generations. With a sufficiently refined mesh (achieved here with a sparse storage scheme) these rates can be accurately tallied without knowledge of the correct fission distribution. The matrix can then be solved for K-eigenvalues and eigenvectors. The right and left eigenvectors correspond to forward and adjoint fission source modes, respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗