Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: Impact of the MRI and MRI fringe field

Purpose: In recent times, longitudinal field MRI-linac systems have been proposed for 6 MV MRI-guided radiotherapy (MRIgRT). The magnetic field is parallel with the beam axis and so will alter the transport properties of any electron contamination particles. The purpose of this work is to provide a first investigation into the potential effects of the MR and fringe magnetic fields on the electron contamination as it is transported toward a phantom, in turn, providing an estimate of the expected patient skin dose changes in such a modality. Methods: Geant4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam were performed. Longitudinal magnetic fields of strengths between 0 and 3 T were applied to a 30 x 30 x 20 cm{sup 3} phantom. Surrounding the phantom there is a region where the magnetic field is at full MRI strength, consistent with clinical MRI systems. Beyond this the fringe magnetic field entering the collimation system is also modeled. The MRI-coil thickness, fringe field properties, and isocentric distance are varied and investigated. Beam field sizes of 5 x 5, 10 x 10, 15 x 15 and 20 x 20 cm{sup 2} were simulated. Central axis dose, 2D virtual entry skin dose films, and 70 {mu}m skin depth doses were calculated using high resolution scoring voxels. Results: In the presence of a longitudinal magnetic field, electron contamination from the linear accelerator is encouraged to travel almost directly toward the patient surface with minimal lateral spread. This results in a concentration of electron contamination within the x-ray beam outline. This concentration is particularly encouraged if the fringe field encompasses the collimation system. Skin dose increases of up to 1000% were observed for certain configurations and increases above Dmax were common. In nonmagnetically shielded cases, electron contamination generated from the jaw faces and air column is trapped and propagated almost directly to the phantom entry region, giving rise to intense dose hot spots inside the x-ray treatment field. These range up to 1000% or more of Dmax at the CAX, depending on field size, isocenter, and coil thickness. In the case of a fully magnetically shielded collimation system and the lowest MRI field of 0.25 T, the entry skin dose is expected to increase to at least 40%, 50%, 65%, and 80% of Dmax for 5 x 5, 10 x 10, 15 x 15, and 20 x 20 cm{sup 2}, respectively. Conclusions: Electron contamination from the linac head and air column may cause considerable skin dose increases or hot spots at the beam central axis on the entry side of a phantom or patient in longitudinal field 6 MV MRIgRT. This depends heavily on the properties of the magnetic fringe field entering the linac beam collimation system. The skin dose increase is also related to the MRI-coil thickness, the fringe field, and the isocenter distance of the linac. The results of this work indicate that the properties of the MRI fringe field, electron contamination production, and transport must be considered carefully during the design stage of a longitudinal MRI-linac system.

43 PARTICLE ACCELERATORS↗

Measurements of the fast electron bremsstrahlung emission during electron cyclotron resonance heating in the HL-2A tokamak

A fast electron bremsstrahlung (FEB) diagnostic technique based on cadmium telluride (CdTe) detector has been developed recently in the HL-2A tokamak for measurements of the temporal evolution of FEB emission in the energy range of 10-200 keV. With a perpendicular viewing into the plasma on the equatorial plane, the hard x-ray spectra with eight different energy channels are measured. The discrimination of the spectra is implemented by an accurate spectrometry. The system also makes use of fast digitization and software signal processing technology. An ambient environment of neutrons, gammas, and magnetic disturbance requires careful shielding. During electron cyclotron resonance heating, the generation of fast electrons and the oscillations of electron fishbone (e-fishbone) have been found. Using the FEB measurement system, it has been experimentally identified that the mode strongly correlates with the electron cyclotron resonance heating produced fast electrons with 30-70 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PROBABILITY OF CME IMPACT ON EXOPLANETS ORBITING M DWARFS AND SOLAR-LIKE STARS

Solar coronal mass ejections (CMEs) produce adverse space weather effects at Earth. Planets in the close habitable zone of magnetically active M dwarfs may experience more extreme space weather than at Earth, including frequent CME impacts leading to atmospheric erosion and leaving the surface exposed to extreme flare activity. Similar erosion may occur for hot Jupiters with close orbits around solar-like stars. We have developed a model, Forecasting a CME's Altered Trajectory (ForeCAT), which predicts a CME's deflection. We adapt ForeCAT to simulate CME deflections for the mid-type M dwarf V374 Peg and hot Jupiters with solar-type hosts. V374 Peg's strong magnetic fields can trap CMEs at the M dwarfs's Astrospheric Current Sheet, that is, the location of the minimum in the background magnetic field. Solar-type CMEs behave similarly, but have much smaller deflections and do not become trapped at the Astrospheric Current Sheet. The probability of planetary impact decreases with increasing inclination of the planetary orbit with respect to the Astrospheric Current Sheet: 0.5–5 CME impacts per day for M dwarf exoplanets, 0.05–0.5 CME impacts per day for solar-type hot Jupiters. We determine the minimum planetary magnetic field necessary to shield a planet's atmosphere from CME impacts. M dwarf exoplanets require values between tens and hundreds of Gauss. Hot Jupiters around a solar-type star, however, require a more reasonable <30 G. These values exceed the magnitude required to shield a planet from the stellar wind, suggesting that CMEs may be the key driver of atmospheric losses.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Effect of Island Overlap on ELM Suppression by Resonant Magnetic Perturbations in DIII-D

Recent DIII-D [J.L. Luxon, et al., Nucl. Fusion 43, 1813 (2003)] experiments show a correlation between the extent of overlap of magnetic islands induced in the edge plasma by perturbation coils and complete suppression of Type-I edge localized modes (ELMs) in plasmas with ITER-like electron pedestal collisionality {nu}*{sub e} {approx} 0.1, flux surface shape and low edge safety factor (q{sub 95} {approx} 3.6). With fixed n = 3 resonant magnetic perturbation (RMP) strength, ELM suppression is obtained only in a finite window in the edge safety factor (q{sub 95}) consistent with maximizing the resonant component of the applied helical field. ELM suppression is obtained over an increasing range of q{sub 95} by either increasing the n = 3 RMP strength, or by adding n = 1 perturbations to 'fill in' gaps between islands across the edge plasma. The suppression of Type-I ELMs correlates with a minimum width of the edge region having magnetic islands with Chirikov parameter >1.0, based on vacuum calculations of RMP mode components excluding the plasma response or rotational shielding. The fraction of vacuum magnetic field lines that are lost from the plasma, with connection length to the divertor targets comparable to an electron-ion collisional mean free path, increases throughout the island overlap region in the ELM suppressed case compared with the ELMing case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source (abstract only)

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (versatile ECR for nuclear science), produce large amounts of x rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power, and heating frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet, adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different from that for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper, we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates depending on various ion source parameters, such as confinement fields, minimum B-field, rf power, and heating frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of electrostatic shielding on the photoelectric properties of heterostructures with deep QWs

The effect of the electrostatic potential induced by charge carriers of the same sign, localized in a deep quantum well, on the current–voltage characteristics of photodetector heterostructures is theoretically analyzed. It is shown for the example of a p–i–n structure with a single deep quantum well in the i-type region that the shielding of an external electric field makes the differential photoconductivity of the heterostructure higher than that in a p–i–n structure without an intermediate 2D layer.

36 MATERIALS SCIENCE↗

Experimental studies of high-confinement mode plasma response to non-axisymmetric magnetic perturbations in ASDEX Upgrade

Here, the interaction of externally applied small non-axisymmetric magnetic perturbations (MP) with tokamak high-confinement mode (H-mode) plasmas is reviewed and illustrated by recent experiments in ASDEX Upgrade. The plasma response to the vacuum MP field is amplified by stable ideal kink modes with low toroidal mode number n driven by the H-mode edge pressure gradient (and associated bootstrap current) which is experimentally evidenced by an observable shift of the poloidal mode number m away from field alignment (m = qn, with q being the safety factor) at the response maximum. A torque scan experiment demonstrates the importance of the perpendicular electron flow for shielding of the resonant magnetic perturbation, as expected from a two-fluid MHD picture. Two significant effects of MP occur in H-mode plasmas at low pedestal collisionality, $\nu _{\text{ped}}^{\ast}\leqslant 0.4$ : (a) a reduction of the global plasma density by up to $61 \% $ and (b) a reduction of the energy loss associated with edge localised modes (ELMs) by a factor of up to 9. A comprehensive database of ELM mitigation pulses at low ${{\nu}^{\ast}}$ in ASDEX Upgrade shows that the degree of ELM mitigation correlates with the reduction of pedestal pressure which in turn is limited and defined by the onset of ELMs, i. e. a modification of the ELM stability limit by the magnetic perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of recent studies and modifications being made to RHIC to mitigate the effects of a potential failure to the helium distribution system

In order to cool the superconducting magnets in RHIC, its helium refrigerator distributes 4.5 K helium throughout the tunnel along with helium distribution for the magnet line recoolers, the heat shield, and the associated return lines. The worse case for failure would be a release from the magnet distribution line which operates at 3.5 to 4.5 atmospheres and contains the energized magnet but with a potential energy of 70 MJoules should the insulation system fail or an electrical connection opens. Studies were done to determine release rate of the helium and the resultant reduction in O{sub 2} concentration in the RHIC tunnel and service buildings. Equipment and components were also reviewed for design and reliability and modifications were made to reduce the likelihood of failure and to reduce the volume of helium that could be released.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two way coupling RAM-SCB to the space weather modeling framework

The Ring current Atmosphere interaction Model with Self-Consistently calculated 3D Magnetic field (RAM-SCB) has been used to successfully study inner magnetosphere dynamics during different solar wind and magnetosphere conditions. Recently, one way coupling of RAM-SCB with the Space Weather Modeling Framework (SWMF) has been achieved to replace all data or empirical inputs with those obtained through first-principles-based codes: magnetic field and plasma flux outer boundary conditions are provided by the Block Adaptive Tree Solar wind Roe-type Upwind Scheme (BATS-R-US) MHO code, convection electric field is provided by the Ridley Ionosphere Model (RIM), and ion composition is provided by the Polar Wind Outflow Model (PWOM) combined with a multi-species MHO approach. These advances, though creating a powerful inner magnetosphere virtual laboratory, neglect the important mechanisms through which the ring current feeds back into the whole system, primarily the stretching of the magnetic field lines and shielding of the convection electric field through strong region two Field Aligned Currents (FACs). In turn, changing the magnetosphere in this way changes the evolution of the ring current. To address this shortcoming, the coupling has been expanded to include feedback from RAM-SCB to the other coupled codes: region two FACs are returned to the RIM while total plasma pressure is used to nudge the MHO solution towards the RAMSCB values. The impacts of the two way coupling are evaluated on three levels: the global magnetospheric level, focusing on the impact on the ionosphere and the shape of the magnetosphere, the regional level, examining the impact on the development of the ring current in terms of energy density, anisotropy, and plasma distribution, and the local level to compare the new results to in-situ measurements of magnetic and electric field and plasma. The results will also be compared to past simulations using the one way coupling and no coupling whatsoever. This work is the first to fully couple an anisotropic kinetic ring current code with a selfconsistently calculated magnetic field to a set of global models.

47 OTHER INSTRUMENTATION↗

Commissioning of horizontal-bend superconducting magnet for Jefferson Lab's 11-GeV super high momentum spectrometer

Commissioning characteristics of the Superconducting High Momentum Spectrometer (SHMS) Horizontal Bend (HB) magnet was presented. Pre-commissioning peer review of the magnet uncovered issues with eddy currents in the thermal shield, resulting in additional testing and modeling of the magnet. A three-stage test plan was discussed. A solution of using a small dump resistor and a warm thermal shield was presented. Analyses illustrated that it was safe to run the magnet to full test current. As a result, the HB magnet was successfully cooled to 4 K and reached its maximum test current of 4000 A.

47 OTHER INSTRUMENTATION↗

Magnetically insulated baffled probe for real-time monitoring of equilibrium and fluctuating values of space potentials, electron and ion temperatures, and densities

By restricting the electron-collection area of a cold Langmuir probe compared to the ion-collection area, the probe floating potential can become equal to the space potential, and thus conveniently monitored, rather than to a value shifted from the space potential by an electron-temperature-dependent offset, i.e., the case with an equal-collection-area probe. This design goal is achieved by combining an ambient magnetic field in the plasma with baffles, or shields, on the probe, resulting in species-selective magnetic insulation of the probe collection area. This permits the elimination of electron current to the probe by further adjustment of magnetic insulation which results in an ion-temperature-dependent offset when the probe is electrically floating. Subtracting the floating potential of two magnetically insulated baffled probes, each with a different degree of magnetic insulation, enables the electron or ion temperature to be measured in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal coupling of Ho W 10 molecular magnets to superconducting circuits near spin clock transitions

A central goal in quantum technologies is to maximize GT 2 , where G stands for the coupling of a qubit to control and readout signals and T 2 is the qubit’s coherence time. Furthermore, this is challenging, as increasing G (e.g., by coupling the qubit more strongly to external stimuli) often leads to deleterious effects on T 2 . Here, we study the coupling of pure and magnetically diluted crystals of Ho W 10 magnetic clusters to microwave superconducting coplanar waveguides. Absorption lines give a broadband picture of the magnetic energy level scheme and, in particular, confirm the existence of level anticrossings at equidistant magnetic fields determined by the combination of crystal field and hyperfine interactions. Such “spin clock transitions” are known to shield the electronic spins against magnetic field fluctuations. The analysis of the microwave transmission shows that the spin-photon coupling also becomes maximum at these transitions. The results show that engineering spin-clock states of molecular systems offers a promising strategy to combine sizable spin-photon interactions with a sufficient isolation from unwanted magnetic noise sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of island overlap on edge localized mode suppression by resonant magnetic perturbations in DIII-D

Recent DIII-D [J. L. Luxon et al., Nucl. Fusion 43, 1813 (2003)] experiments show a correlation between the extent of overlap of magnetic islands induced in the edge plasma by perturbation coils and complete suppression of Type-I edge localized modes (ELMs) in plasmas with ITER-like electron pedestal collisionality {nu}{sub e}*{approx}0.1, flux surface shape and low edge safety factor (q{sub 95}{approx_equal}3.6). With fixed amplitude n=3 resonant magnetic perturbation (RMP), ELM suppression is obtained only in a finite window in the edge safety factor (q{sub 95}) consistent with maximizing the resonant component of the applied helical field. ELM suppression is obtained over an increasing range of q{sub 95} by either increasing the n=3 RMP strength, or by adding n=1 perturbations to ''fill in'' gaps between islands across the edge plasma. The suppression of Type-I ELMs correlates with a minimum width of the edge region having magnetic islands with Chirikov parameter >1.0, based on vacuum calculations of RMP mode components excluding the plasma response or rotational shielding. The fraction of vacuum magnetic field lines that are lost from the plasma, with connection length to the divertor targets comparable to an electron-ion collisional mean free path, increases throughout the island overlap region in the ELM suppressed case compared with the ELMing case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗