Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

From RNNs to Foundation Models: An Empirical Study on Commercial Building Energy Consumption

Accurate short-term energy consumption forecasting for commercial buildings is crucial for smart grid operations. While smart meters and deep learning models enable forecasting using past data from multiple buildings, data heterogeneity from diverse buildings can reduce model performance. The impact of increasing dataset heterogeneity in time series forecasting, while keeping size and model constant, is understudied. We tackle this issue using the ComStock dataset, which provides synthetic energy consumption data for U.S. commercial buildings. Two curated subsets, identical in size and region but differing in building type diversity, are used to assess the performance of various time series forecasting models, including finetuned open-source foundation models (FMs). The results show that dataset heterogeneity and model architecture have a greater impact on post-training forecasting performance than the parameter count. Moreover, despite the higher computational cost, finetuned FMs demonstrate competitive performance compared to base models trained from scratch.

commercial buildings↗

Modeling Workloads of a Linear Electromagnetic Code for Load Balancing Matrix Assembly

This report presents our work to model the workloads of a linear electromagnetic application based on the method of moments in the frequency domain to effectively load balance the matrix assembly. This application is particularly challenging to load balance due to its lack of persistent iterative behavior, its operation under tight memory constraint (where the matrix may fill 80% of memory on each node), and the algorithmic complexity of the computational method. This report describes the first step in our work to apply an inspector-executor approach for load balancing workloads where key parameters are exposed during the inspector phase and a pre-trained model is applied to predict relative task weights for the load balancer.

97 MATHEMATICS AND COMPUTING↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Model to Account for the Effects of Load Ratio and Hydrogen Pressure on the Fatigue Crack Growth Behavior of Pressure Vessel Steels

A phenomenological model for estimating the effects of load ratio R and hydrogen pressure P H2 on the hydrogen-assisted fatigue crack growth rate (HA–FCGR) behavior in the transient and steady-state regimes of pressure vessel steels is described. The “transient regime” is identified with crack growth within a severely embrittled zone of intense plasticity at the crack tip. The “steady-state” behavior is associated with the crack growing into a region of comparatively lower hydrogen concentration located further away from the crack tip. The model treats the effects of R and P H2 as being functionally separable. In the transient regime, the effects of the hydrogen pressure on the HA–FCGR behavior were negligible but were significant in the steady-state regime. The hydrogen concentration in the steady-state region is modeled as being dependent on the kinetics of lattice diffusion, which is sensitive to pressure. Experimental HA–FCGR data from the literature were used to validate the model. The new model was shown to be valid over a wide range of conditions that ranged between –1 ≤ R ≤ 0.8 and 0.02 ≤ P H2 ≤ 103 MPa for pressure vessel steels.

36 MATERIALS SCIENCE↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Scheduling and Control of Flexible Building Loads for Grid Services Based on a Virtual Battery Model

This paper presents a framework for modeling, scheduling, and controlling residential thermostatically controlled loads (TCLs) to provide multiple grid services, such as energy shifting, peak load reduction, and ancillary services. A modeling method is proposed to characterize the aggregate flexibility from heterogeneous TCLs using a battery-equivalent model. Based on the flexibility model, a multi-period optimal scheduling formulation is developed to best utilize the flexibility from building loads and maximize total benefits from stacked value streams. An algorithm is proposed to control individual TCLs to follow the desired power consumption in real-time. The proposed methods are illustrated and validated through simulations.

Wu, Di↗

A control-oriented combustion model framework for compression ignition engines operating on low-reactivity fuel

This work focuses on zero-dimensional modeling of the heat release rate in a compression ignition engine operating on gasoline-like fuels. Due to the properties of gasoline, such as high volatility and longer ignition delay than diesel, the injection strategies can vary significantly from the operation with conventional diesel fuel. Different injection strategies are commonly used to achieve varying degrees of in-cylinder stratification in order to shape the combustion event and maximize efficiency. The proposed zero-dimensional combustion model was developed to account for the different stages in combustion caused by the fuel stratification. As the ignition delay model is an integral part of the entire combustion process and significantly affects the prediction accuracy, special attention has been paid to local phenomena influencing ignition delay. A one-dimensional spray model by Musculus and Kattke was employed in conjunction with a Lagrangian tracking approach in order to estimate the local air–fuel ratio within the spray tip, as a proxy for reactivity. The local air–fuel ratio, in-cylinder temperature and pressure were used in an integral fashion to estimate the ignition delay. Heat release rates were modeled using first-order non-linear differential equations. The proposed combustion model was validated against experimental data of a heavy-duty compression ignition engine with up to three injection events at mostly 1038 r/min and 14 bar brake mean effective pressure. Further validation of the model was carried out at other engine loads and speeds. Model prediction errors in CA50 of less than 1 °CA across all conditions were found. Modeling results of other combustion metrics such as combustion duration and indicated mean effective pressure are also highly satisfactory. In addition, the model has been shown to be capable of estimating the ringing intensity for most conditions.

Pamminger, Michael↗

Subhourly Clipping Correction Model Comparison

This work will compare the Allen method and Walker method of accounting for subhourly inverter clipping power losses in hourly PV performance models. The Allen method uses a matrix lookup based on DNI clearness and clipping potential to assign a clipping correction loss at each simulation timestep. The Walker method models the PV DC power input to the inverter as a distribution over the hourly timestep and uses integration over the timestep to determine the amount of clipping that occurs within the timestep. Both these models have been recently implemented in the System Advisor Model's (SAM) open-source code, and will be applied to hourly SURFRAD datasets to analyze the subhourly clipping loss predicted by each model for different system designs and inverter loading conditions. Both models will be compared to "true" 1-minute SURFRAD data simulations to see their accuracy against more accurate 1-minute clipping correction loss predictions. This model comparisons will be investigated in more detail at the PVSC conference in Seattle, Washington June 2024.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Declining carbohydrate solubilization with increasing solids loading during fermentation of cellulosic feedstocks by Clostridium thermocellum: documentation and diagnostic tests

Abstract Background For economically viable 2nd generation biofuels, processing of high solid lignocellulosic substrate concentrations is a necessity. The cellulolytic thermophilic anaerobe Clostridium thermocellum is one of the most effective biocatalysts for solubilization of carbohydrate harbored in lignocellulose. This study aims to document the solubilization performance of Clostridium thermocellum at increasing solids concentrations for two lignocellulosic feedstocks, corn stover and switchgrass, and explore potential effectors of solubilization performance. Results Monocultures of Clostridium thermocellum demonstrated high levels of carbohydrate solubilization for both unpretreated corn stover and switchgrass. However, fractional carbohydrate solubilization decreases with increasing solid loadings. Fermentation of model insoluble substrate (cellulose) in the presence of high solids lignocellulosic spent broth is temporarily affected but not model soluble substrate (cellobiose) fermentations. Mid-fermentation addition of cells ( C. thermocellum ) or model substrates did not significantly enhance overall corn stover solubilization loaded at 80 g/L, however cultures utilized the model substrates in the presence of high concentrations of corn stover. An increase in corn stover solubilization was observed when water was added, effectively diluting the solids concentration mid-fermentation. Introduction of a hemicellulose-utilizing coculture partner, Thermoanaerobacterium thermosaccharolyticum, increased the fractional carbohydrate solubilization at both high and low solid loadings. Residual solubilized carbohydrates diminished significantly in the presence of T. thermosaccharolyticum compared to monocultures of C. thermocellum, yet a small fraction of solubilized oligosaccharides of both C 5 and C 6 sugars remained unutilized. Conclusion Diminishing fractional carbohydrate solubilization with increasing substrate loading was observed for C. thermocellum -mediated solubilization and fermentation of unpretreated lignocellulose feedstocks. Results of experiments involving spent broth addition do not support a major role for inhibitors present in the liquid phase. Mid-fermentation addition experiments confirm that C. thermocellum and its enzymes remain capable of converting model substrates during the middle of high solids lignocellulose fermentation. An increase in fractional carbohydrate solubilization was made possible by (1) mid-fermentation solid loading dilutions and (2) coculturing C. thermocellum with T. thermosaccharolyticum , which ferments solubilized hemicellulose. Incomplete utilization of solubilized carbohydrates suggests that a small fraction of the carbohydrates is unaffected by the extracellular carbohydrate-active enzymes present in the culture.