Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Studies of event burst phenomenon with SiPMs in liquid nitrogen

Silicon photomultiplier (SiPM) are used to collect scintillation photons in many cryogenic noble liquid detectors deployed around the world, such as DarkSide, nEXO, MEGII, ProtoDUNE and DUNE. An event burst phenomenon was observed during routine characterization on many models of SiPMs operated in liquid nitrogen. These bursts of consecutive pulses are initiated by an intense dark photoelectron pulse with an event rate much lower than the time-uncorrelated thermal dark pulse. Although the rate of these burst events is very low, it can potentially compromise some dedicated rare physics event searches which are also anticipated to be of extremely low rate. Here, we systematically studied the behavior of the event burst phenomenon and identified the probable cause of the phenomenon. Here, this investigation is important for the selection of SiPMs for use in noble liquid detectors, high energy physics experiments, and industrial applications where SiPMs are used in cryogenic environment.

47 OTHER INSTRUMENTATION↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Measurement of Rayleigh Scattering in Liquid Argon at Vacuum Ultraviolet Wavelengths

Liquid argon based experiments are limited in scintillation light analysis capabilities due to inconsistent measured values of fundamental constants essential for reconstructing scintillation events. This experiment measures the Rayleigh scattering length of vacuum ultraviolet light propagating in liquid argon to support liquid argon experiments by expanding the scope of scintillation signal analysis. Preliminary results are presented for the Rayleigh scattering length in arange of vacuum ultraviolet wavelengths, including the liquid argon scintillation peak wavelength. Currently, further data collection and analysis is required to reduce measurement uncertainty as well as quantify and correct for other effects such as the photon detector temperature dependence. Results will contribute to the development of new photon detector system analysis methods for liquid argon experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Updated parameters of the LArQL model

The need for a microscopic description of scintillation light generation in liquid argon becomes increasingly desirable with the upcoming operation of large scale LArTPCs in the next decade. While a detailed mathematical account of the process is still to be achieved, a phenomenological model for simultaneously treating ionization and scintillation, LArQL, has been successfully employed to describe the range of electric fields from 0 to 0.75 kV/cm and dE/dx from 2 to 40 MeV/cm providing the anti-correlation between the free ionization charge and scintillation light. A reanalysis of the original model parameter values has been performed within a global fit procedure and is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production and testing of the large-area photon detector ArCLight

Compact large-area dielectric photon detectors that ensure modular noble liquid detectors can sense scintillation light signals for triggering and reconstruction purposes with minimal impact to the overall target volume. ArCLight is a small-volume, sizeable sensitive-area detector that consists of a light trap covered in a thin layer of TPB that can be placed inside a time projection chamber's electric field. These sensors are used in the Deep Underground Neutrino Experiment Near Detector liquid argon (DUNE ND-LAr). They are constructed and tested at the University of Bern and will be deployed in the prototype experiment ProtoDUNE-ND. The talk discusses the details of assembling ArCLights, the quality control methods, and the test studies done with LEDs to assess their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Highly efficient photon detection systems for noble liquid detectors based on perovskite quantum dots

Abstract Wavelength shifting photon detection systems (PDS) are the critical functioning components in noble liquid detectors used for high energy physics (HEP) experiments and dark matter search. The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). The currently used organic wavelength shifting materials [such as 1,1,4,4 Tetraphenyl Butadiene (TPB)] have several disadvantages and are unreliable for longterm use. In this study, we demonstrate the application of the inorganic perovskite cesium lead bromide (CsPbBr 3 ) quantum dots (QDs) as highly efficient wavelength shifters. The absolute photoluminescence quantum yield of the PDS fabricated using these QDs exceeds 70%. CsPbBr 3 -based PDS demonstrated an enhancement in the SiPM signal enhancement by up to 3 times when compared to a 3 µm-thick TPB-based PDS. The emission spectrum from the QDs was optimized to match the highest quantum efficiency region of the SiPMs. In addition, we have demonstrated the deposition of the QD-based wavelength shifting material on a large area PDS substrate using low capital cost and widely scalable solution-based techniques providing a pathway appropriate for meter-scale PDS fabrication and widespread use for other wavelength shifting applications.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.