Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIVER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting patient survival and stent patency, and stent patency showed statistically significant correlation with patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Visibility of Metastatic Disease in the Liver During Intra-Arterial Therapy Using Delayed Arterial Phase Cone-Beam CT

PurposeTo compare the visibility of liver metastases on dual-phase cone-beam CT (DP-CBCT) and digital subtraction angiography (DSA), with reference to preinterventional contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis IRB-approved, retrospective study included 28 patients with neuroendocrine (NELM), colorectal (CRCLM), or sarcoma (SLM) liver metastases who underwent DP-CBCT during intra-arterial therapy (IAT) between 01/2010 and 10/2014. DP-CBCT was acquired after a single contrast agent injection in the tumor-feeding arteries at early and delayed arterial phases (EAP and DAP). The visibility of each lesion was graded by two radiologists in consensus on a three-rank scale (complete, partial, none) on DP-CBCT and DSA images using CE-MRI as reference.Results47 NELM, 43 CRCLM, and 16 SLM were included. On DSA 85.1, 44.1, and 37.5 % of NELM, CRCLM, and SLM, were at least partially depicted, respectively. EAP-CBCT yielded significantly higher sensitivities of 88.3 and 87.5 % for CRCLM and SLM, respectively (p < 0.01), but not for NELM (89.4 %; p = 1.0). On DAP-CBCT all NELM, CRCLM, and SLM were visible (p < 0.001). Complete depiction was achieved on DSA for 59.6, 16.3, and 18.8 % of NELM, CRCLM, and SLM, respectively. The complete depiction rate on EAP-CBCT was significantly higher for CRCLM (46.5 %; p < 0.001), lower for NELM (40.4 %; p = 0.592), and similar for SLM (25 %, p = 0.399). On DAP-CBCT however, the highest rates of complete depiction were found—NELM (97.8 %; p = 0.008), CRCLM (95.3 %; p = 0.008), and SLM (100 %; p < 0.001).ConclusionDAP-CBCT substantially improved the visibility of liver metastases during IAT. Future studies need to evaluate the clinical impact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization of Neuroendocrine Liver Metastases Using Streptozocin and Tris-acryl Microspheres: Embozar (EMBOsphere + ZAnosaR) Study

PurposeThe purpose of this prospective observational study was to evaluate the efficacy and tolerability of transarterial chemoembolization (TACE) for neuroendocrine liver metastases using a combination of streptozocin, Lipiodol, and tris-acryl microspheres.Patients and MethodsA total of 16 men and 9 women aged 59.6 ± 11.3 years, all with predominant liver disease, underwent 54 courses of TACE using an emulsion of 1.5 g of streptozocin and 10 ml of Lipiodol. Additional embolization was performed using 300–500 µm tris-acryl microspheres. Morphological response was evaluated using the RECIST criteria on multi-detector computed tomography or MRI. Clinical efficacy was evaluated particularly in patients with carcinoid syndrome.ResultsThe primary tumor was located in the small bowel or pancreas in 21 (84%) patients. Eleven (44%) patients presented with a carcinoid syndrome. Nineteen (76%) patients presented with more than 10 liver nodules. One delayed case of ischemic cholecystitis was treated conservatively. After a median follow-up of 36.1 months, 1 (4%) patient had a complete response, 12 (48%) patients had a partial response, and 7 (28%) patients had a stable disease corresponding to a disease control rate of 80%. All patients with carcinoid syndrome had significant improvement. Median time to progression was 18.8 months and overall survival was 100, 100, and 92% at 1, 2, and 3 years, respectively. Seven patients presented with extrahepatic progression with abdominal lymphadenopathies or metastases to the brain, ovary, adrenal gland, or lung.ConclusionOptimized TACE using a combination of streptozocin, Lipiodol, and tris-acryl microspheres is effective and well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Combined with Hepatic Arterial Chemoembolization Using Degradable Starch Microsphere Mixed with Mitomycin C for the Treatment of Liver Metastasis from Colorectal Cancer: A Prospective Multicenter Study

PurposeThis phase II prospective study investigates possible benefits of radiofrequency ablation (RFA) combined with hepatic arterial chemoembolization using degradable starch microsphere (DSM) mixed with mitomycin C (MMC) in non-surgical candidates with colorectal liver metastases.Materials and MethodsThis study, approved by the respective institutional review board, included non-surgical candidates with 3 or fewer liver tumors of 3 cm or smaller, or a single lesion 5 cm or smaller. Percutaneous RFA was performed immediately after chemoembolization using DSM-MMC. Primary and secondary endpoints were the local tumor control rate, safety, and 2-year recurrence-free and overall survival rates.ResultsThis study examined 25 patients (22 males, 3 females) with 38 tumors of mean maximum diameter of 2.2 ± 0.9 cm (standard deviation) (range 1.0–4.2 cm). Their mean age was 70.2 ± 8.2 years (range 55–82 years). Local tumor progression developed in 3 tumors (7.9%, 3/38) of 3 patients (12%, 3/25) during the mean follow-up of 34.9 ± 9.2 months (range 18.3–50.1 months). The 2-year local tumor control rates were 92.0% [95% confidence interval (CI), 81.4–100%] on a patient basis and 94.6% (95% CI, 87.3–100%) on a tumor basis. The respective 2-year overall and recurrence-free survival rates were 88.0% (95% CI, 75.3–98.5%) and 63.3% (95% CI, 44.2–82.5%), with median survival time of 48.4 months. Fever was the only adverse event requiring treatments in 2 patients (8%).ConclusionsThis combination therapy is safe, exhibiting strong anticancer effects on colorectal liver metastasis, which might contribute to patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segment 2/3 Hypertrophy is Greater When Right Portal Vein Embolisation is Extended to Segment 4 in Patients with Colorectal Liver Metastases: A Retrospective Cohort Study

Background: In patients with colorectal cancer liver metastases (CRLM), right portal vein embolisation (RPVE) is used to increase the volume of the future remnant liver (FRL) before major hepatic resection. It is not established whether embolisation of segment 4 in addition RPVE (RPVE + 4) induces greater hypertrophy of the FRL. Limitations of prior studies include heterogenous populations and use of hypertrophy metrics sensitive to baseline variables. Methods: From 2010 to 2015, consecutive patients undergoing RPVE or RPVE + 4 for CRLM, who had not undergone prior major hepatic resection and in whom imaging was available, were included in a retrospective study. Data were extracted from hospital electronic records. Volumetric assessments of segments 2–3 were made on cross-sectional imaging before and after embolisation and corrected for standardised liver volume. Results: Ninety-nine patients underwent PVE, and 60 met the inclusion criteria. Thirty-eight patients underwent RPVE, and 22 underwent RPVE + 4. Forty-five patients had undergone median 6 cycles of prior chemotherapy. Eighteen patients had FRL metastases at PVE, and 16 had undergone subsegmental metastasectomy in the FRL. Assessments of the degree of hypertrophy (DH) of segments 2/3 were made at median 35 (interquartile range 30–49) days after PVE. RPVE + 4 resulted in a significantly greater increase in DH than RPVE (7.7 ± 1.8% vs 11.3 ± 2.6%, p = 0.011). No confounding association between baseline variables and the decision to undertake RPVE or RPVE + 4 was identified. Median survival was 2.4 years and was not influenced by segment 4 embolisation. Conclusion: RPVE + 4 results in greater DH of segments 2/3 than RPVE in people with CLRM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose and Risk Estimates of CT-Guided Percutaneous Liver Ablations and Factors Associated with Dose Reduction

PurposeTo determine the radiation dose associated with CT-guided percutaneous liver ablations and identify potential risk factors that result in higher radiation doses.Materials and MethodsBetween June 2011 and June 2015, 245 consecutive patients underwent 304 CT-guided liver ablation treatments. Patient demographics, tumor characteristics and procedural parameters were identified and analyzed. The peak skin dose and effective dose were assessed for each procedure. Excess relative risk related to radiation effects was calculated. A logistic regression model was prepared by means of stepwise logistic regression to identify variables predictive of increased radiation exposure.ResultsTumor ablations were performed with microwave (n = 220), radiofrequency (n = 74) or irreversible electroporation (IRE) (n = 10). The mean peak skin dose for ablations was 239.2 ± 136.4 mGy, and the mean effective dose was 36.6 ± 22.3 mSv. Of the patient and procedural parameters that were analyzed, increasing weight, use of intravenous contrast and/or hydrodissection during the procedure, together with treatment of multiple lesions in the same sitting were all associated with higher radiation exposure. The mean increase in the absolute risk of fatal malignancy from a single procedure was 0.18% (range 0.02–0.9%). No deterministic skin changes were identified in the patient cohort.ConclusionThe overall risk of stochastic and deterministic effects from radiation associated with CT-guided ablations is low compared with other inherent procedural complications. This study identifies several factors that are associated with higher radiation dose in percutaneous liver ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time US-{sup 18}FDG-PET/CT Image Fusion for Guidance of Thermal Ablation of {sup 18}FDG-PET-Positive Liver Metastases: The Added Value of Contrast Enhancement

Purpose: To assess the feasibility of US-{sup 18}FDG-PET/CT fusion-guided microwave ablation of liver metastases either poorly visible or totally undetectable with US, CEUS and CT, but visualized by PET imaging. Materials and Methods: Twenty-three patients with 58 liver metastases underwent microwave ablation guided by image fusion system that combines US with {sup 18}FDG-PET/CT images. In 28/58 tumors, {sup 18}FDG-PET/CT with contrast medium (PET/CECT) was used. The registration technical feasibility, registration time, rates of correct targeting, technical success at 24 h, final result at 1 year and complications were analyzed and compared between the PET/CT and PET/CECT groups. Results: Registration was successfully performed in all cases with a mean time of 7.8 + 1.7 min (mean + standard deviation), (4.6 + 1.5 min for PET/CECT group versus 10.9 + 1.8 min for PET/CT group, P < 0.01). In total, 46/58 (79.3%) tumors were correctly targeted, while 3/28 (10.7%) and 9/30 (30%) were incorrectly targeted in PET/CT and PET/CECT group, respectively (P < 0.05). Complete ablation was obtained at 24 h in 70.0% of cases (n = 40 tumors), 23/28 (82.1%) in the PET/CECT group and 17/30 (56.7%) in the PET/CT group (P < 0.037). Fourteen tumors underwent local retreatment (11 ablations, 2 with resection and 1 with stereotactic body radiation therapy), while 4 tumors could not be retreated because of distant disease progression and underwent systemic therapy. Finally, 54/58 (93.1%) tumors were completely treated at 1 year. One major complication occurred, a gastrointestinal hemorrhage which required surgical repair. Conclusions: Percutaneous ablation of {sup 18}FDG-PET-positive liver metastases using fusion imaging of real-time US and pre-acquired {sup 18}FDG-PET/CT images is feasible, safe and effective. Contrast-enhanced PET/CT improves overall ablation accuracy and shortens procedural duration time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reiterative Radiofrequency Ablation in the Management of Pediatric Patients with Hepatoblastoma Metastases to the Lung, Liver, or Bone

Background and Purpose: Conventional treatments of systemic chemotherapy and surgical resection for recurrent or metastatic hepatoblastoma (HB) may be inhibitive for the pediatric patient and family who have already been through extensive therapies. This single-institution case series evaluates the safety and efficacy of percutaneous radiofrequency ablation (RFA) in the management of metastatic HB. Materials and Methods: Between March 2008 and February 2015, RFA was used as part of multidisciplinary management for HB recurrence or metastasis in 5 children (median 5.0 years old) in an attempt to provide locoregional control and preclude additional surgery. Combined local treatments of 38 metachronous metastases included surgical metastasectomy (14 lesions: 7 lung, 7 liver), percutaneous RFA (23 lesions: 21 lung, 1 liver, 1 bone), and stereotactic radiotherapy (1 liver lesion). Results: For lesions treated with RFA (median diameter 6 mm, range 3–15 mm), local control was achieved in 22/23 metastases (95.6%) with median follow-up of 30.1 months after RFA (range 18.9–65.7). Median hospitalization was 3 days (2–7), with major complications limited to 1 pneumothorax requiring temporary small-caliber chest tube. Four children remain in complete remission with median follow-up of 67 months (range 41.2–88.8) after primary tumor resection, with mean disease-free survival of 31.7 months after last local treatment. One child succumbed to rapidly progressive disease 12 months after RFA (23.9 months after primary tumor resection). Conclusion: RFA provides a safe and effective reiterative treatment option in the multidisciplinary management of children with metastatic HB.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Accumulation and Effects of Liposomal Doxorubicin in Tissues Treated by Radiofrequency Ablation and Irreversible Electroporation in Liver: In Vivo Experimental Study on Porcine Models

Purpose: To compare the accumulation and effect of liposomal doxorubicin in liver tissue treated by radiofrequency ablation (RFA) and irreversible electroporation (IRE) in in vivo porcine models. Materials and Methods: Sixteen RFA and 16 IRE procedures were performed in healthy liver of two groups of three pigs. Multi-tined RFA parameters included: 100 W, target temperature 105°C for 7 min. 100 IRE pulses were delivered using two monopolar electrodes at 2250 V, 1 Hz, for 100 µsec. For each group, two pigs received 50 mg liposomal doxorubicin (0.5 mg/kg) as a drip infusion during ablation procedure, with one pig serving as control. Samples were harvested from the central and peripheral zones of the ablation at 24 and 72 h. Immunohistochemical analysis to evaluate the degree of cellular stress, DNA damage, and degree of apoptosis was performed. These and the ablation sizes were compared. Doxorubicin concentrations were also analyzed using fluorescence photometry of homogenized tissue. Results: RFA treatment zones created with concomitant administration of doxorubicin at 24 h were significantly larger than controls (2.5 ± 0.3 cm vs. 2.2 ± 0.2 cm; p = 0.04). By contrast, IRE treatment zones were negatively influenced by chemotherapy (2.2 ± 0.4 cm vs. 2.6 ± 0.4 cm; p = 0.05). At 24 h, doxorubicin concentrations in peripheral and central zones of RFA were significantly increased in comparison with untreated parenchyma (0.431 ± 0.078 µg/g and 0.314 ± 0.055 µg/g vs. 0.18 ± 0.012 µg/g; p < 0.05). Doxorubicin concentrations in IRE zones were not significantly different from untreated liver (0.191 ± 0.049 µg/g and 0.210 ± 0.049 µg/g vs. 0.18 ± 0.012 µg/g). Conclusions: Whereas there is an increased accumulation of periprocedural doxorubicin and an associated increase in ablation zone following RFA, a contrary effect is noted with IRE. These discrepant findings suggest that different mechanisms and synergies will need to be considered in order to select optimal adjuvants for different classes of ablation devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety of Percutaneous Hepatic Perfusion with Melphalan in Patients with Unresectable Liver Metastases from Ocular Melanoma Using the Delcath Systems’ Second-Generation Hemofiltration System: A Prospective Non-randomized Phase II Trial

Purpose: To investigate the safety and toxicity of percutaneous hepatic perfusion with melphalan (M-PHP) with the Delcath Systems’ second-generation (GEN 2) filter and compare the outcomes with historical data from studies using the first-generation filter. Materials and Methods: A prospective, single-arm, single-center phase II study was carried out including 35 patients with unresectable, histologically confirmed liver metastases from ocular melanoma between February 2014 and June 2017. Main exclusion criteria were extrahepatic disease and age > 75 years. M-PHP was performed with melphalan 3 mg/kg (maximum dose 220 mg). Safety and toxicity were assessed according to the Common Terminology Criteria for Adverse Events version 4.03. Results: A total of 67 M-PHPs were performed in 35 patients (median 2 procedures). Although hematologic grade 3/4 events were seen in the majority of patients (thrombocytopenia 54.5%, leukopenia 75.6%, neutropenia 66.7%, anemia (only grade 3) 18.1%), these were all well manageable or self-limiting. Of the non-hematologic grade 3 events (n = 14), febrile neutropenia (n = 3), pulmonary emboli (n = 2) and post-procedural hemorrhage (n = 2) were most common. A case of sepsis with bacterial pharyngitis was the only non-hematologic grade 4 event. Prior therapy for liver metastases was found to be a predictor of late grade 3/4 neutropenia with an odds ratio of 5.5 (95% CI 1.4–21.7). Conclusions: M-PHP using the GEN 2 filter has an acceptable safety and toxicity profile, and seems to reduce hematologic toxicity when compared to M-PHP with a first-generation filter. Prior therapy of liver metastases is a possible predictive factor in developing grade 3/4 hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tissue-Specific Peculiarities of Vibration-Induced Hypoxia in Rabbit Liver and Kidney

Activity of the energy production systems in rabbit liver and kidney under conditions of unfavorable vibration exposure was studied by the polarography method using a galvanic-type closed oxygen sensor. The rate of oxidation of endogenous substrates by mitochondria was determined by the tissue and was 5.2±0.6 and 8.13±1.4 (ng-atom O)×min{sup —1}×mg{sup —1} protein for liver and kidney of intact animals, respectively. After 21 vibration sessions against the background of inhibition of NAD-dependent substrate oxidation in liver mitochondria, the rate metabolism of exogenous succinic acid increased by 44% and then decreased with prolongation of the effect, which indicated impaired function of the respiratory chain. Similar fluctuations of the parameters were revealed in kidney mitochondria, though their amplitude was lower. The study of bioenergetic mechanisms of hypoxia in various tissues makes it possible to determine the targets for the pharmacological action of antihypoxic drugs.

60 APPLIED LIFE SCIENCES↗

Chlorogenic acid ameliorates endotoxin-induced liver injury by promoting mitochondrial oxidative phosphorylation

Acute or chronic hepatic injury is a common pathology worldwide. Mitochondrial dysfunction and the depletion of adenosine triphosphate (ATP) play important roles in liver injury. Chlorogenic acids (CGA) are some of the most abundant phenolic acids in human diet. This study was designed to test the hypothesis that CGA may protect against chronic lipopolysaccharide (LPS)-induced liver injury by modulating mitochondrial energy generation. CGA decreased the activities of serum alanine aminotransferase, aspartate aminotransferase and alkaline phosphatase. The contents of ATP and adenosine monophosphate (AMP), as well as the ratio of AMP/ATP, were increased after CGA supplementation. The activities of enzymes that are involved in glycolysis were reduced, while those of enzymes involved in oxidative phosphorylation were increased. Moreover, phosphorylated AMP-activated protein kinase (AMPK), and mRNA levels of AMPK-α, peroxisome proliferator-activated receptor-gamma coactivator 1α (PGC-1α), nuclear respiratory factor 1, and mitochondrial DNA transcription factor A were increased after CGA supplementation. Collectively, these findings suggest that the hepatoprotective effect of CGA might be associated with enhanced ATP production, the stimulation of mitochondrial oxidative phosphorylation and the inhibition of glycolysis. - Highlights: • Dietary supplementation with chlorogenic acid (CGA) improved endotoxin-induced liver injury. • Chlorogenic acid enhances ATP increase and shifts energy metabolism, which is correlated with up-regulation AMPK and PGC-1α. • The possible mechanism of CGA on mitochondrial biogenesis was correlated with up-regulation AMPK and PGC-1α.

60 APPLIED LIFE SCIENCES↗

Isoliquiritigenin protects against sepsis-induced lung and liver injury by reducing inflammatory responses

Highlights: • Inflammation plays a key role in sepsis-induced lung and liver injury. • Isoliquiritigenin reduced the LPS-induced inflammation in MPMs. • Isoliquiritigenin attenuated the inflammation-mediated liver and injury. • Isoliquiritigenin exhibited anti-inflammatory effects via inactivation of NF-κB. • Isoliquiritigenin is a potential agent for inflammatory injuries in sepsis. Sepsis, one of the most fatal diseases worldwide, often leads to multiple organ failure, mainly due to uncontrolled inflammatory responses. Despite accumulating knowledge obtained in recent years, effective drugs to treat sepsis in the clinic are still urgently needed. Isoliquiritigenin (ISL), a chalcone compound, has been reported to exert anti-inflammatory properties. However, little is known about the effects of ISL on sepsis and its related complications. In this study, we investigated the potential protective effects of ISL on lipopolysaccharide (LPS)-induced injuries and identified the mechanisms underlying these effects. ISL inhibited inflammatory cytokine expression in mouse primary peritoneal macrophages (MPMs) exposed to LPS. In an acute lung injury (ALI) mouse model, ISL prevented LPS-induced structural damage and inflammatory cell infiltration. Additionally, pretreatment with ISL attenuated sepsis-induced lung and liver injury, accompanied by a reduction in inflammatory responses. Moreover, these protective effects were mediated by the nuclear factor kappa B (NF-κB) pathway-mediated inhibition of inflammatory responses in vitro and in vivo. Our study suggests that ISL may be a potential therapeutic agent for sepsis-induced injuries.

60 APPLIED LIFE SCIENCES↗

Long-term fermented soybean paste improves metabolic parameters associated with non-alcoholic fatty liver disease and insulin resistance in high-fat diet-induced obese mice

Highlights: • LFSP, but not SFSP, reverses HFD-induced NAFLD and insulin resistance in mice. • LFSP suppresses mesenteric fat lipolysis and hepatic lipid uptake. • LFSP enhances insulin sensitivity and adiponectin-mediated anti-inflammatory action. • LFSP suppresses HFD-induced gut permeability leading to attenuated chronic inflammation. • LFSP-derived Bacillus strains attenuates HFD-induced obesity and glucose intolerance. Recently, Korean traditional fermented soybean paste, called Doenjang, has attracted attention for its protective effect against diet-related chronic diseases such as obesity and type 2 diabetes. Long-term fermented soybean pastes (LFSPs) are made by fermentation with naturally-occurring microorganisms for several months, whereas short-term fermented soybean pastes (SFSPs) are produced by shorter-time fermentation inoculated with a starter culture. Here, we demonstrate that administration of LFSP, but not SFSP, protects high-fat diet (HFD)-fed obese mice against non-alcohol fatty liver disease (NAFLD) and insulin resistance. LFSP suppressed body weight gain in parallel with reduction in fat accumulation in mesenteric adipose tissue (MAT) and the liver via modulation of MAT lipolysis and hepatic lipid uptake. LFSP-treated mice also had improved glucose tolerance and increased adiponectin levels concomitantly with enhanced AMPK activation in skeletal muscle and suppressed expression of pro-inflammatory cytokines in skeletal muscle and the liver. LFSP also attenuated HFD-induced gut permeability and lowered serum lipopolysaccharide level, providing an evidence for its probiotic effects, which was supported by the observation that treatment of a probiotic mixture of LFSP-originated Bacillus strains protected mice against HFD-induced adiposity and glucose intolerance. Our findings suggest that the intake of LFSP, but not SFSP, offers protection against NAFLD and insulin resistance, which is an effect of long-term fermentation resulting in elevated contents of active ingredients (especially flavonoids) and higher diversity and richness of Bacillus probiotic strains compared to SFSP.

60 APPLIED LIFE SCIENCES↗

Effect of cisplatin on the clock genes expression in the liver, heart and kidney

Highlights: • Cisplatin-induced nephrotoxicity showed a circadian rhythm. • Cisplatin altered the clock genes expression in a tissue- and gene-specific manner. • Dbp was consistently suppressed in peripheral tissues after cisplatin treatment. Cisplatin is a platinum-based chemotherapy drug that is widely used to treat various types of malignancies. Although the involvement of circadian clock in cisplatin metabolism and excretion has been reported, the effect of cisplatin on circadian rhythm remains unclear. In the present study, we investigated the effects of cisplatin on clock genes expression in mouse peripheral tissues. Cisplatin induced severe nephrotoxicity, as revealed by the significant increase of blood urea nitrogen and serum creatinine levels. Moreover, cisplatin circadian time-dependently induced p21 expression in the liver, heart and kidney, with the highest increase during the dark phase. In addition, cisplatin altered the clock genes expression in the liver, heart and kidney in a tissue- and gene-specific manner. Interesting, the expression of D site of the albumin promoter binding protein (Dbp), a gene involved in detoxification and drug metabolism, was consistently suppressed in the liver, heart and kidney after cisplatin treatment, implying a role of DBP in the toxicity of cisplatin.

60 APPLIED LIFE SCIENCES↗

Dose Escalated Liver Stereotactic Body Radiation Therapy at the Mean Respiratory Position

Purpose: The dosimetric impact of dose probability based planning target volume (PTV) margins for liver cancer patients receiving stereotactic body radiation therapy (SBRT) was compared with standard PTV based on the internal target volume (ITV). Plan robustness was evaluated by accumulating the treatment dose to ensure delivery of the intended plan. Methods and Materials: Twenty patients planned on exhale CT for 27 to 50 Gy in 6 fractions using an ITV-based PTV and treated free-breathing were retrospectively evaluated. Isotoxic, dose escalated plans were created on midposition computed tomography (CT), representing the mean breathing position, using a dose probability PTV. The delivered doses were accumulated using biomechanical deformable registration of the daily cone beam CT based on liver targeting at the exhale or mean breathing position, for the exhale and midposition CT plans, respectively. Results: The dose probability PTVs were on average 38% smaller than the ITV-based PTV, enabling an average ± standard deviation increase in the planned dose to 95% of the PTV of 4.0 ± 2.8 Gy (9 ± 5%) on the midposition CT (P<.01). For both plans, the delivered minimum gross tumor volume (GTV) doses were greater than the planned nominal prescribed dose in all 20 patients and greater than the planned dose to 95% of the PTV in 18 (90%) patients. Nine patients (45%) had 1 or more GTVs with a delivered minimum dose more than 5 Gy higher with the midposition CT plan using dose probability PTV, compared with the delivered dose with the exhale CT plan using ITV-based PTV. Conclusions: For isotoxic liver SBRT planned and delivered at the mean respiratory, reduced dose probability PTV enables a mean escalation of 4 Gy (9%) in 6 fractions over ITV-based PTV. This may potentially improve local control without increasing the risk of tumor underdosing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗