Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Assimilation of the Microwave Limb Sounder Radiances

It has been shown that the assimilation of limb-sounder data can significantly improve the representation of ozone in NASA's GEOS Data Assimilation Systems (GEOS-DAS), particularly in the stratosphere. The studies conducted so far utilized retrieved data from the MIPAS, POAM, ILAS and EOS Microwave Limb Sounder (EOS MLS) instruments. Direct assimilation of the radiance data can be seen as the natural next step to those studies. The motivation behind working with radiances is twofold. First, retrieval algorithms use a priori data which are either climatological or are obtained from previous analyses. This introduces additional uncertainty and, in some cases, may lead to "self-contamination"- when the a priori is taken from the same assimilation system in which subsequently ingests the retrieved observations. Second, radiances can be available in near real time thus providing an opportunity for operational assimilation, which could help improve the use of infrared radiance instruments from operational satellite instruments. In this presentation we summarize our ongoing work on an implementation of the assimilation of EOS MLS radiances into the GEOS-5 DAS. This work focuses on assimilation of band 7 brightness temperatures which are sensitive to ozone. Our implementation uses the MLS Callable Forward Model developed by the MLS team at NASA JPL as the observation operator. We will describe our approach and recent results which are not yet final. In particular, we will demonstrate that this approach has a potential to improve the vertical structure of ozone in the lower tropical stratosphere as compared with the retrieved MLS product. We will discuss the computational efficiency of this implementation.

Wargan, K.↗

LADEE UVS Observations of Solar Occulation by Exospheric Dust above the Lunar Limb

The Lunar Atmosphere and Dust Environment Explorer (LADEE) is a lunar orbiter launched in September 2012 that investigates the composition and temporal variation of the tenuous lunar exosphere and dust environment. The primary goals of the mission are to characterize the pristine gas and dust exosphere prior to future lunar exploration activities, which may alter the lunar environment. To address this goal, the LADEE instrument suite includes an Ultraviolet/ Visible Spectrometer (UVS), which searches for dust, Na, K, and trace gases such as OH, H2O, Si, Al, Mg, Ca, Ti, Fe, as well as other previously undetected species. UVS has two sets of optics: a limb-viewing telescope, and a solar viewing telescope. The solar viewer is equipped with a diffuser (see Figure 1a) that allows UVS to stare directly at the solar disk as the Sun starts to set (or rise from) behind the lunar limb. Solar viewer measurements generally have very high signal to noise (SNR>500) for 20-30 ms integration times. The 1-degree solar viewer field of view subtends a diameter of ~8 km at a distance of 400-450 km

pristine gas↗

LADEE UVS Observations of Solar Occultation by Exospheric Dust Above the Lunar Limb

The Lunar Atmosphere and Dust Environment Explorer (LADEE) is a lunar orbiter launched in September 2012 that investigates the composition and temporal variation of the tenuous lunar exosphere and dust environment. The primary goals of the mission are to characterize the pristine gas and dust exosphere prior to future lunar exploration activities, which may alter the lunar environment. To address this goal, the LADEE instrument suite includes an Ultraviolet/ Visible Spectrometer (UVS), which searches for dust, Na, K, and trace gases such as OH, H2O, Si, Al, Mg, Ca, Ti, Fe, as well as other previously undetected species. UVS has two sets of optics: a limb-viewing telescope, and a solar viewing telescope. The solar viewer is equipped with a diffuser (see Figure 1a) that allows UVS to stare directly at the solar disk as the Sun starts to set (or rise from) behind the lunar limb. Solar viewer measurements generally have very high signal to noise (SNR greater than 500) for 20-30 ms integration times. The 1-degree solar viewer field of view subtends a diameter of approximately 8 km at a distance of 400-450 km.

LADEE↗

Altitude Registration of Limb-Scattered Radiation

One of the largest constraints to the retrieval of accurate ozone profiles from UV backscatter limb sounding sensors is altitude registration. Two methods, the Rayleigh scattering attitude sensing (RSAS) and absolute radiance residual method (ARRM), are able to determine altitude registration to the accuracy necessary for long-term ozone monitoring. The methods compare model calculations of radiances to measured radiances and are independent of onboard tracking devices. RSAS determines absolute altitude errors, but, because the method is susceptible to aerosol interference, it is limited to latitudes and time periods with minimal aerosol contamination. ARRM, a new technique introduced in this paper, can be applied across all seasons and altitudes. However, it is only appropriate for relative altitude error estimates. The application of RSAS to Limb Profiler (LP) measurements from the Ozone Mapping and Profiler Suite (OMPS) on board the Suomi NPP (SNPP) satellite indicates tangent height (TH) errors greater than 1 km with an absolute accuracy of +/-200 m. Results using ARRM indicate a approx. 300 to 400m intra-orbital TH change varying seasonally +/-100 m, likely due to either errors in the spacecraft pointing or in the geopotential height (GPH) data that we use in our analysis. ARRM shows a change of approx. 200m over 5 years with a relative accuracy (a long-term accuracy) of 100m outside the polar regions.

Ozone profiles↗

Improving the Performance of the OMPS Limb Profiling Instrument in Monitoring Aerosols in the Post-Pinatubo Stratosphere

The OMPS Limb Profiling (LP) instrument was launched on NOAA's Suomi NPP (SNPP) weather satellite in October 2011. The instrument measures limb-scattered radiation in the ultraviolet, visible and NIR wavelengths with high vertical resolution (~2 km) and relatively dense spatial and temporal sampling (several thousand measurements/day covering the entire sunlit globe). These measurements have very high sensitivity to stratospheric aerosols due to long path of the incoming solar photons through the aerosol layer. However, unlike the recently launched ISS/SAGE III that directly measures extinction of solar/lunar radiation by gases and particles along the line of sight (LOS) of the instrument, information content of OMPS LP measurements is complex. It consists of solar radiation singly scattered and attenuated by aerosols, air, and trace gases along the LOS of the instrument, as well as diffuse upwelling radiation from the lower atmosphere that also gets scattered and attenuated into the LOS. To unscramble this complex signal one needs to have good knowledge of aerosol size distribution (ASD) and their complex refractive index. We will describe our recent efforts in constraining the ASD parameters by analyzing in-situ balloon data from Laramie, Wyoming; aerosol microphysical model data from CARMA; and spectral information provided by OMPS LP. We will also discuss our proposed methodology to refine this information by adjusting the microphysical properties of the aerosols to make data from various occultation and scattering instruments internally consistent. This is a generalized version of the technique employed by AERONET in which solar extinction data are combined with scattered radiation measured by the almucantar technique to determine aerosol particle shape, complex refractive index and size distribution. We suggest that such closure studies are essential to develop confidence in space-based data to validate aerosol microphysical models, such as CARMA, and aerosol chemistry- transport models, such as GOCART, and for estimating radiative forcing due to stratospheric aerosols in both volcanic and quiescent time periods.

Bhartia, P. K.↗

Vertical Profiles of Mars 1.27 Micrometer O2 Dayglow from MRO CRISM Limb Spectra: Seasonal/global Behaviors, Comparisons to LMDGCM Simulations, and a Global Definition for Mars Water Vapor Profiles

Since July of 2009, The Compact Reconnaissance Imaging Spectral Mapper (CRISM) onboard the Mars Re- connaissance Orbiter (MRO) has periodically obtained pole-to-pole observations (i.e., full MRO orbits) of limb scanned visible/near IR spectra (lambda= 0.4 - 4.0 micrometers, delta lambda approx. 10 nm- Murchie et al., 2007). These CRISM limb observations support the first seasonally and spatially extensive set of Mars 1.27 micometers O2 (1 delta(sub g)) day-glow profile retrievals (approx. 1100) over greater than or equal to 8-80 km altitudes. Their comparison to Laboratoire de Meteorologie Dynamique (LMD) global climate model (GCM) simulated O2 (1 delta(sub g)) volume emission rate (VER) profiles, as a function of altitude, latitude, and season (solar longitude, L(sub s), supports several key conclusions regarding Mars atmospheric water vapor (which is derived from O2 (1 delta(sub g)) emission rates), Mars O3, and the collisional de-excitation of O2 (1 delta(sub g)) in the Mars CO2 atmosphere. Current (Navarro et al., 2014) LMDGCM simulations of Mars atmospheric water vapor fall 2-3 times below CRISM derived water vapor abundances at 20-40 km altitudes over low-to-mid latitudes in northern spring (L(sub s) = 30-60 deg), and northern mid-to-high latitudes over northern summer (L(sub s) = 60-140 deg). In contrast, LMDGCM simulated water vapor is 2-5 times greater than CRISM derived values at all latitudes and seasons above 40 km, within the aphelion cloud belt (ACB), and over high-southern to mid-southern latitudes in southern summer (L(sub s) = 190-340 deg) at 15-35 km altitudes. Overall, the solstitial summer-to-winter hemisphere gradients in water vapor are reversed between the LMDGCM modeled versus the CRISM derived water vapor abundances above 10-30 km altitudes. LMDGCM-CRISM differences in water vapor profiles correlate with LMDGCM-CRISM differences in cloud mixing profiles; and likely reflect limitations in simulating cloud microphysics and radiative forcing, both of which restrict meridional transport of water from summer- to-winter hemispheres on Mars (Clancy et al., 1996; Montmessin et al., 2004; Steele et al., 2014; Navarro et al., 2014) and depend on uncertain cloud microphysical properties (Navarro et al., 2014). The derived low-to-mid latitude changes in Mars water vapor vertical distributions should reduce current model- data disagreements in column O3 and H2O2 abundances over low-to-mid latitudes (e.g., within the ACB; Lefevre et al., 2008; Encrenaz et al., 2015; Clancy et al., 2016). Lastly, the global/seasonal average com- parison of CRISM and LMDGCM O2 (1 delta(sub g)) VER below 20 km altitudes indicates a factor of approx. 3 times lower value (0.25 x 10(exp -20) cu cm sec(exp -1)) for the CO2 collisional de-excitation rate coefficient of O2 (1 delta(sub g)) than derived recently by Guslyakova et al. (2016).

Clancy, R. Todd↗

Autonomous Navigation over Europa Analogue Terrain for an Actively Articulated Wheel-on-Limb Rover

The ocean world Europa is a prime target forexploration given its potential habitability [1]. We proposea mobile robotic system that is capable of autonomouslytraversing hundreds of meters to visit multiple sites of intereston a Europan analogue surface. Due to the topology of Europanterrain being largely unknown, it is desired that this mobilitysystem traverse a large variety of terrain types. The mobilitysystem should also be capable of crossing unstructured terrainin an autonomous manner given the communications limitationsbetween Earth and Europa.A wheel-on-limb robotic rover is presented that may activelyconform to terrain features up to 1.5 wheel diameters tall whiledriving. The robot uses a sampling-based motion planner togenerate paths that leverage its unique locomotive capabilities.The planner assesses terrain hazards and wheel workspacelimits as obstacles. It may also select a mobility mode basedon predicted energy usage and the need for limb articulationon the terrain being traversed. This autonomous mobility wasevaluated on the chaotic salt-evaporite terrain found in DeathValley, CA, an analogue to the Europan surface. Over the courseof 38 trials, the rover autonomously traversed 435m of extremeterrain while maintaining a rate of 0.64 traverse ending failuresfor every 10m driven.

Meirion-Griffith, Gareth↗

Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Center-to-limb Variation of Transition-region Doppler Shifts in Active Regions

Studying Doppler shifts provides deep insights into the flow of mass and energy in the solar atmosphere. We perform a comprehensive measurement of Doppler shifts in the transition region and its center-to-limb variation (CLV) in the strong-field regions (∣B∣ ≥ 50 G) of 50 active regions (ARs), using the Si iv 1394 Å line recorded by the Interface Region Imaging Spectrometer. To locate the ARs and identify strong-field regions, we have used the magnetograms obtained by the Helioseismic and Magnetic Imager (HMI). We find that in strong-field regions, on average, all the ARs show a mean redshift ranging between 4 and 11 km s−1, which varies with ARs. These flows show a mild CLV, with sizable magnitudes at the limb and substantial scatter in the mid-longitude range. Our observations do not support the idea that redshifts in the lower transition region (T ≲ 0.1 MK) are produced by field-aligned downflows as a result of impulsive heating and they warrant an alternative interpretation, such as a downflow of type-II spicules in the presence of a chromospheric wall created by cooler type-I spicules.

Abhishek Rajhans↗

A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

Mueller, John Kyle P↗

Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolisation of a Proximal Type I Endoleak Post-Nellix Aortic Aneurysm Repair Complicated by Reflux of Onyx into the Nellix Endograft Limb

We report the first case of intervention for a proximal type 1 endoleak following Nellix endovascular aneurysm sealing repair of an aortic aneurysm. This was complicated by migration of Onyx into one of the Nellix graft limbs causing significant stenosis. Subsequent placement of a covered stent to affix the Onyx between the stent and the wall of the Nellix endograft successfully restored stent patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic Tumor Location Influences the Success of Contemporary Limb-Sparing Surgery and Radiation Among Adults With Soft Tissue Sarcomas of the Extremities

Purpose: To examine the influence of anatomic location in the upper extremity (UE) vs. lower extremity (LE) on the presentation and outcomes of adult soft tissue sarcomas (STS). Methods and Materials: From 2001 to 2008, 118 patients underwent limb-sparing surgery (LSS) and external beam radiotherapy (RT) with curative intent for nonrecurrent extremity STS. RT was delivered preoperatively in 96 and postoperatively in 22 patients. Lesions arose in the UE in 28 and in the LE in 90 patients. Patients with UE lesions had smaller tumors (4.5 vs. 9.0 cm, p < 0.01), were more likely to undergo a prior excision (43 vs. 22%, p = 0.03), to have close or positive margins after resection (71 vs. 49%, p = 0.04), and to undergo postoperative RT (32 vs. 14%, p = 0.04). Results: Five-year actuarial local recurrence-free and distant metastasis-free survival rates for the entire group were 85 and 74%, with no difference observed between the UE and LE cohorts. Five-year actuarial probability of wound reoperation rates were 4 vs. 29% (p < 0.01) in the UE and LE respectively. Thigh lesions accounted for 84% of the required wound reoperations. The distribution of tumors within the anterior, medial, and posterior thigh compartments was 51%, 26%, and 23%. Subset analysis by compartment showed no difference in the probability of wound reoperation between the anterior and medial/posterior compartments (29 vs. 30%, p = 0.68). Neurolysis was performed during resection in (15%, 5%, and 67%, p < 0.01) of tumors in the anterior, medial, and posterior compartments. Conclusions: Tumors in the UE and LE differ significantly with respect to size and management details. The anatomy of the UE poses technical impediments to an R0 resection. Thigh tumors are associated with higher wound reoperation rates. Tumor resection in the posterior thigh compartment is more likely to result in nerve injury. A better understanding of the inherent differences between tumors in various extremity sites will assist in individualizing treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V{sub d}) receiving specified doses ({>=}30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 {+-} 8.9 Gy, V30 of 14.5 {+-} 2.3 cc, V45 of 11.8 {+-} 1.1 cc, and V60 of 7.2 {+-} 2.2 cc at the femoral neck compared with 22.9 {+-} 20.8 Gy, 4.8 {+-} 5.6 cc, 2.5 {+-} 3.9 cc, and 0.8 {+-} 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose-volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trunk muscle forces and spinal loads while walking in persons with lower limb amputation: Influences of chronic low back pain

Persons with lower limb amputation (LLA) are at high risk for developing chronic low back pain (LBP), often with biomechanical factors considered as likely contributors. Here, trunk and pelvis kinematics, muscle forces, and resultant spinal loads were characterized in persons with LLA, with and without chronic LBP. Thirty-five persons with unilateral LLA – 19 with chronic LBP (“LLA-cLBP”), 16 without LBP (“LLA-nLBP”) – and 15 (uninjured) persons without LBP (“CTR-nLBP”) walked overground (1.3 m/s) while thorax and pelvis kinematics were tracked (and ranges of motion [ROM] computed), and used as inputs for a non-linear finite element model of the spine to estimate global and local muscle forces, and resultant spinal loads. In the frontal and transverse planes, thorax ROM were up to 66.6% smaller in LLA-nLBP versus LLA-cLBP (P < 0.001) and CTR-nLBP (P < 0.001). In the sagittal plane, pelvis ROM was 50.4% smaller in LLA-nLBP versus LLA-cLBP (P = 0.014). LLA-cLBP exhibited 45.5% and 34.2% greater peak local and global muscle forces, respectively, versus CTR-nLBP (P < 0.011). Up to 48.1% greater spinal loads were observed in LLA-cLBP versus CTR-nLBP (P < 0.013); peak compression and local muscle forces were respectively 20.2% and 41.0% larger in LLA-nLBP versus CTR-nLBP (P < 0.005). Despite differences in trunk and pelvis kinematics between LLA-cLBP and LLA-nLBP, trunk muscle forces and spinal loads were similar (P > 0.101) between these groups. Similar loading parameters regardless of LBP presence, while highly dependent on trunk muscle activation strategies, may mitigate further accumulation of mechanical fatigue. Finally, it remains important to understand the temporality of loading with respect to LBP onset following LLA.

60 APPLIED LIFE SCIENCES↗