Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Applying large datasets to developing a better understanding of air leakage measurement in homes

Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. There are several methods for measuring air tightness that may result in different values and sometimes quite different uncertainties. The two main approaches trade off bias and precision errors and thus result indifferent outcomes for accuracy and repeatability. To interpret results from the two approaches, various questions need to be addressed, such as the need to measure the flow exponent, the need to make both pressurization and depressurization measurements and the role of wind in determining the accuracy and precision of the results. This article uses two large datasets of blower door measurements to reach the following conclusions. For most tests the pressure exponent should be measured but for wind speeds greater than 6 m/s a fixed pressure exponent reduces experimental error. The variability in reported pressure exponents is mostly due to changes in envelope leakage characteristics. Finally, it is preferable to test in both pressurization and depressurization modes due to significant differences between the results in these two modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of air leakage paths: a comparison of airflow and acoustic measurements

Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Finally, although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neutral leakage, power dissipation and pedestal fueling in open vs closed divertors

The effect of divertor closure on neutral leakage, power dissipation and pedestal fueling is explored using the SOLPS code for different densities including attached and detached divertor conditions for DIII-D open and closed divertors. Here, a metric for divertor closure in terms of the percentage of neutrals escaping the divertor is presented. At the detachment onset the population of neutrals escaping the divertor is 12% for the closed divertor and 35% for the open divertor. This results in a lower contribution of the convective term to the total heat flux and increased power losses in the closed divertor. The comparison between the two geometries reveals that for the same upstream density, the upstream temperature is 23% higher in the closed divertor. The physical mechanisms for detachment at lower upstream density in the closed divertor are also identified with the reduction of the convective term directly resulting in 40% decrease and the increased power losses contributing with a factor of 2. The baffling also lowers the neutral flux refueling the pedestal resulting in further reduction of the core density for achieving detachment. The results introduced here show that the divertor recycling is the primary fueling mechanism in DIII-D. It is shown that fueling occurring in the region between the X-point and the outer midplane is at least four times lower in the closed divertor due the baffling structure which enhances target neutral trapping and consequently reduced upstream leakage. Due to the openness of the inner leg to the common flux and HFS regions both open and closed divertor experience almost identical fueling at the HFS highlighting the need to also consider the inboard divertor for shape optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity leakage and radiative cooling in the first nitrogen and neon seeding study in the closed DIII-D SAS configuration

A comparative study of nitrogen versus neon has been carried out to analyze the impact of the two radiative species on power dissipation, SOL impurity distribution, divertor and pedestal characteristics. The experimental results show that N remains compressed in the divertor, thereby providing high radiative losses without affecting the pedestal profiles and displacing carbon as dominant radiator. Neon, instead, radiates more upstream than N thus reducing the power flux through the separatrix leading to a reduced ELM frequency and compression in the divertor. A significant amount of neon is measured in the plasma core leading to a steeper density gradient. The different behavior between the two impurities is confirmed by SOLPS-ITER modeling which for the first time at DIII-D includes multiple impurity species and a treatment of full drifts, currents and neutral–neutral collisions. The impurity transport in the SOL is studied in terms of the parallel momentum balance showing that N is mostly retained in the divertor whereas Ne leaks out consistent with its higher ionization potential and longer mean free path. This is also in agreement with the enrichment factor calculations which indicate lower divertor enrichment for neon. The strong ionization source characterizing the SAS divertor causes a reversal of the main ions and impurity flows. The flow reversal together with plasma drifts and the effect of the thermal force contribute significantly in the shift of the impurity stagnation point affecting impurity leakage. This work provides a demonstration of the impurity leakage mechanism in a closed divertor structure and the consequent impact on pedestal. Since carbon is an intrinsic radiator at DIII-D, in this paper we have also demonstrated the different role of carbon in the N vs Ne seeded cases both in the experiments and in the numerical modeling. Here, carbon contributes more when neon seeding is injected compared to when nitrogen is used. Finally, the results highlight the importance of accompanying experimental studies with numerical modeling of plasma flows, drifts and ionization profile to determine the details of the SOL impurity transport as the latter may vary with changes in divertor regime and geometry. In the cases presented here, plasma drifts and flow reversal caused by high level of closure in the slot upper divertor at DIII-D play an important role in the underlined mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution of leakage currents in the cylindrical and conical sections of the magnetically insulated transmission line of the Angara-5-1 facility in experiments with wire arrays

Current leakages in the magnetically insulated transmission lines (MITL) impose restrictions on the transmission of electromagnetic pulses to the load in high-power electrophysical facilities. The multimodule Angara-5-1 facility with an output electric power of up to 6 TW is considered. In this work, the experimental and calculated profiles of leakage currents in two sections of the line are compared when the eight-module facility is loaded by a wire array. The azimuthal distribution of the current in the cylindrical section of the MITL is also considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Leakage currents in 4H-SiC JBS diodes

Leakage currents in high-voltage 4H-SiC diodes, which have an integrated (p-n) Schottky structure (Junction Barrier Schottky, JBS), have been studied using commercial diodes and specially fabricated (based on a commercial epitaxial material) test Schottky diodes with and without the JBS structure. It is shown that (i) the main role in reverse charge transport is played by SiC crystal structure defects, most probably, by threading dislocations (density {approx}10{sup 4} cm{sup -2}), and (ii) the JBS structure, formed by the implantation of boron, partially suppresses the leakage currents (by up to a factor of 10 at optimal separation, 8 {mu}m between local p-type regions).

36 MATERIALS SCIENCE↗

On the problem of internal optical loss and current leakage in laser heterostructures based on AlGaInAs/InP solid solutions

Semiconductor lasers based on MOCVD-grown AlGaInAs/InP separate-confinement heterostructures are studied. It is shown that raising only the energy-gap width of AlGaInAs-waveguides without the introduction of additional barriers results in more pronounced current leakage into the cladding layers. It is found that the introduction of additional barrier layers at the waveguide–cladding-layer interface blocks current leakage into the cladding layers, but results in an increase in the internal optical loss with increasing pump current. It is experimentally demonstrated that the introduction of blocking layers makes it possible to obtain maximum values of the internal quantum efficiency of stimulated emission (92%) and continuouswave output optical power (3.2 W) in semiconductor lasers in the eye-safe wavelength range (1400–1600 nm).

36 MATERIALS SCIENCE↗

Determination of the Steady State Leakage Current in Structures with Ferroelectric Ceramic Films

Steady state leakage currents have been investigated in capacitor structures with ferroelectric solgel films of lead zirconate titanate (PZT) formed on silicon substrates with a lower Pt electrode. It is established that Pt/PZT/Hg structures, regardless of the PZT film thickness, are characterized by the presence of a rectifying contact similar to p–n junction. The steady state leakage current in the forward direction increases with a decrease in the film thickness and is determined by the ferroelectric bulk conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Epitaxial InGaAs/InAlAs/AlAs Structures for Heterobarrier Varactors with Low Leakage Current

The quality of heteroboundaries and optimal conditions for epitaxial growth are critical parameters for obtaining low leakage currents of heterobarrier varactors in the InGaAs/InAlAs/AlAs material system. Grown by molecular-beam epitaxy, three-barrier heterobarrier varactor structures adjacent to InAlAs/AlAs/InAlAs barrier layers by additional mismatched InGaAs layers subjected to compressive stress show, under optimal epitaxy conditions, extremely low levels of leakage current density (not more than 0.06 A/cm{sup 2} at a voltage of 5 V and 85°C) with relatively thin AlAs inserts (with a thickness of 2 nm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Leakage Valves for Long Duration Missions

This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.

Cryogenic Fluid Management↗

Low Leakage Valves for Long Duration Missions

This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.

Cryogenic Fluid Management↗

Advancements in Low Leakage Valves for Long Duration Missions

This paper reports on the advancements in the development of low-leakage valve technology for cryogenic environments, currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and test results.

Cryogenic Fluid Management↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling CO 2 flow in support of a shallow subsurface controlled leakage field test

Here, controlled release of carbon dioxide (CO 2 ) into the soil and atmosphere is performed to test detection and monitoring tools, for which several field laboratories were established by a number of institutions worldwide. Numerical simulations of CO 2 behavior in the shallow subsurface region are other forms of validation and verification of the leakage pathways and destinations. These reports aim to improve monitoring and verification of CO 2 in case of unexpected leakages for public assurance. In this work, we introduce the results of a numerical modeling study conducted to simulate the injection of CO 2 as carried out during a field test in Viamão, southern Brazil, where 20 kg day –1 of CO 2 was pumped for 30 days through a vertical well 3 m below ground in an altered granitic soil. Multiphase flow simulations were performed with the TOUGH2/EOS7CA software for unsaturated porous media, using field data and injection parameters, including sensitivity tests to permeability direction, diffusivity, and boundary conditions. Results with increased horizontal permeabilities are in better agreement with the field observations. In this condition, mass balance calculations indicate approximately 90% of injected CO2 (20 kg day –1 during 30 days) remains in the soil after 180 days from injection start, consistent with the measured flow through the soil–atmosphere interface.

03 NATURAL GAS↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential method for measurement of CO2 leakage from underground sequestration fields using radioactive tracers

Reduction of anthropogenic carbon dioxide (CO2) release to the environment is a pressing challenge that should be addressed to avert the potential devastating effects of global warming. Within the United States, the most abundant sources of CO2 emissions are those generate from coal- or gas-fired power plants; one method to control CO2 emissions is to sequester it in deep underground geological formations. From integrated assessment models the overall leakage rates from these storage locations must be less than 0.1% of stored volume per year for long-term control. The ability to detect and characterize nascent leaks, in conjunction with subsequent remediation efforts, will significantly decrease the amount of CO2 released back into the environment. Because potential leakage pathways are not necessarily known a priori, onsite monitoring must be performed; the monitoring region in the vicinity of a CO2 injection well may be as large as 100 km2, which represents the estimated size of a supercritical CO2 bubble that would form under typical injection scenarios. By spiking the injected CO2 with a radiological or stable isotope tracer, it will be possible to detect ground leaks from the sequestered CO2 using fewer sampling stations, with greater accuracy than would be possible using simple CO2 sensors. The relative merits of various sorbent materials, radiological and stable isotope tracers, detection methods and potential interferences will be discussed.

01 COAL, LIGNITE, AND PEAT↗

CO 2 leakage impacts on shallow groundwater. Field-scale reactive-transport simulations informed by observations at a natural analog site

It is challenging to predict the degree to which shallow groundwater might be affected by leaks from a CO 2 sequestration reservoir, particularly over long time scales and large spatial scales. In this study observations at a CO 2 enriched shallow aquifer natural analog were used to develop a predictive model which is then used to simulate leakage scenarios. This natural analog provides the opportunity to make direct field observations of groundwater chemistry in the presence of elevated CO 2 , to collect aquifer samples and expose them to CO 2 under controlled conditions in the laboratory, and to test the ability of multiphase reactive transport models to reproduce measured geochemical trends at the field-scale. The field observations suggest that brackish water entrained with the upwelling CO 2 are a more significant source of trace metals than in situ mobilization of metals due to exposure to CO 2 . The study focuses on a single trace metal of concern at this site: U. Experimental results indicate that cation exchange/adsorption and dissolution/precipitation of calcite containing trace amounts of U are important reactions controlling U in groundwater at this site, and that the amount of U associated with calcite is fairly well constrained. Simulations incorporating these results into a 3-D multi-phase reactive transport model are able to reproduce the measured ranges and trends between pH, pCO 2 , Ca, total C, U and Cl - at the field site. Although the true fluxes at the natural analog site are unknown, the cumulative CO 2 flux inferred from these simulations are approximately equivalent to 37.8E-3 MT, approximately corresponding to a .001% leak rate for injection at a large (750 MW) power plant. The leakage scenario simulations suggest that if the leak only persists for a short time the volume of aquifer contaminated by CO 2 -induced mobilization of U will be relatively small, yet persistent over 100 a.

54 ENVIRONMENTAL SCIENCES↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗