Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Airborne dual laser excitation and mapping of phytoplankton photopigments in a Gulf Stream Warm Core Ring

Utilization of a two-color airborne lidar system in the systematic study of a major oceanographic feature is reported here for the first time. An excimer pumped dye laser was optically and electronically integrated into the NASA Airborne Oceanographic Lidar for simultaneous use with a frequency doubled Nd:YAG laser. The output beams exit the laser system along parallel paths after being produced on an alternating pulse basis at a combined rate of 12.5 pps. Results are presented for missions flown over a Gulf Stream Warm Core Ring (WCR) as well as over shelf, slope, Gulf Stream, and Sargasso Sea waters. From the airborne data a high coherence is shown between the two-color chlorophyll a data and between the Nd:YAG chlorophyll a and phycoerythrin responses within each of these water masses. However, distinct differences in the response patterns of these photopigments are shown to exist between the differing water masses. At certain of the boundaries separating the water masses a sharp transition is seen to occur, while at others a wider transition zone was observed in which the correlation between the photopigments appears to degrade.

Hoge, F. E.↗

Laser wavelength selector and output coupler

Optical system eliminates displacement occurring when wavelengths are selected in multiple wavelength laser utilizing intracavity wavelength selection by first-order Littrow reflection of plane grating. Output coupling varies direction of output beam as different wavelengths are selected by grating rotation.

Hard, T. M.↗

Simulation of the output power of copper bromide lasers by the MARS method

The dependence of the output power of CuBr lasers (operating at wavelengths of 510.6 and 578.2 nm) on ten input physical parameters has been statistically analysed based on a large amount of experimental data accumulated for these lasers. Regression models have been built using the flexible nonparametric method of multivariate adaptive regression splines (MARS) to describe both linear and nonlinear local dependences. These models cover more than 97% initial data with an error comparable with the experimental error; they are applied to estimate and predict the output powers of both existing and future lasers. The advantage of the models constructed for estimating laser parameters over the standard parametric methods of multivariate factor and regression analysis is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mirror with a variable amplitude - phase reflectance. 2. Modelling of a laser resonator with an active output mirror

We present the operator model of the laser resonator with an active output mirror based on the Fabry - Perot interferometer with nonflat (spherical and aspherical) mirrors and an adjustable gap. The results of numerical simulation of a microchip laser with a thermal lens and an active output interferometer-based mirror are given. It is shown that the use of an active interferometer as the output cavity mirror allows one to control the number of transverse modes of laser radiation and its power; in this case, the beam divergence can be reduced by a factor of 1.5 - 2.5. (laser resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of the waveguide layer thickness on output characteristics of semiconductor lasers with emission wavelength from 1500 to 1600 nm

The effect of the waveguide layer thickness on output characteristics of AlGaInAs/InP quantum-well semiconductor lasers is analysed. The samples of semiconductor lasers with narrow and wide waveguides are experimentally fabricated. Their comparison is carried out and the advantages of particular constructions depending on the current pump are demonstrated. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavelength-selective, sequential Q-switching laser cavity

Single-frequency continuous output of laser is converted into series of high-power laser pulses at high repetition rates. Applications include pollutant detection by absorption, laser gain measurements at discrete wavelengths, laser propagation measurement, and laser plasma diagnostics.

Allario, F.↗

Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vs treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single longitudinal mode operation of an XeCl laser

Single longitudinal mode output from a directly tuned, long pulse, magnetically switched XeCl laser is reported for the first time. Mode control was achieved using spatial apertures and intracavity etalons. The narrow bandwidth laser output was diffraction limited with an optical pulse width of 30 ns, which would yield a transform limited bandwidth of 30 MHz.

Pacala, T. J.↗

Method and device for remotely monitoring an area using a low peak power optical pump

A method and device for remotely monitoring an area using a low peak power optical pump comprising one or more pumping sources, one or more lasers; and an optical response analyzer. Each pumping source creates a pumping energy. The lasers each comprise a high reflectivity mirror, a laser media, an output coupler, and an output lens. Each laser media is made of a material that emits a lasing power when exposed to pumping energy. Each laser media is optically connected to and positioned between a corresponding high reflectivity mirror and output coupler along a pumping axis. Each output coupler is optically connected to a corresponding output lens along the pumping axis. The high reflectivity mirror of each laser is optically connected to an optical pumping source from the one or more optical pumping sources via an optical connection comprising one or more first optical fibers.

47 OTHER INSTRUMENTATION↗

Repetitively pulsed Fe: ZnSe laser with an average output power of 20 W at room temperature of the polycrystalline active element

The energy and spectral-temporal characteristics of a Fe : ZnSe laser operating in pulsed and repetitively pulsed regimes are studied at room temperature of the polycrystalline active element. The crystal was pumped by a nonchain electric-discharge HF laser. The energy of the Fe : ZnSe laser in a single-pulse regime was 1.67 J at the slope efficiency with respect to the absorbed and incident energy of ∼43% and ∼27%, respectively. In a repetitively pulsed regime with a pulse repetition rate of 20 Hz and an efficiency with respect to the absorbed power of ∼40%, the average laser power was ∼20 W with an individual pulse energy of ∼1 J. The possibility of increasing the average power of the repetitively pulsed Fe : ZnSe laser at room temperature is discussed. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct solar-pumped iodine laser amplifier

A XeCl laser which was developed earlier for an iodine laser oscillator was modified in order to increase the output pulse energy of XeCl laser so that the iodine laser output energy could be increased. The electrical circuit of the XeCl laser was changed from a simple capacitor discharge circuit of the XeCl laser to a Marx system. Because of this improvement the output energy from the XeCl laser was increased from 60 mj to 80 mj. Subsequently, iodine laser output energy was increased from 100 mj to 3 mj. On the other hand, the energy storage capability and amplification characteristics of the Vortek solar simulator-pumped amplifier was calculated expecting the calculated amplification factor is about 2 and the energy extraction efficiency is 26 percent due to the very low input energy density to the amplifier. As a result of an improved kinetic modeling for the iodine solar simulator pumped power amplifier, it is found that the I-2 along the axis of the tube affects seriously the gain profile. For the gas i-C3F7I at the higher pressures, the gain will decrease due to the I-2 as the pumping intensity increases, and at these higher pressures an increase in flow velocity will increase the gain.

Han, Kwang S.↗

Development of a Fiber Laser Welding Capability for a Firing Set

Development work to implement a new welding system for a Firing Set is presented. The new system is significant because it represents the first use of fiber laser welding technology at the KCP. The work used Six-Sigma tools for weld characterization and to define process performance. Determinations of workable weld parameters and comparison to existing equipment were completed. Replication of existing waveforms was done utilizing an Arbitrary Pulse Generator (APG), which was used to modulate the fiber laser’s exclusive continuous wave (CW) output. Fiber laser weld process capability for a Firing Set is demonstrated.

36 MATERIALS SCIENCE↗

Controlling Chaotic Lasers

Irregular fluctuations in intensity have long plagued the operation of a wide variety of solid-state lasers. We are exploring the possibility of exploiting rather than avoiding a laser's chaotic output. As an important step in that direction, we have applied a novel control technique to stabilize a solid state laser. By making small periodic changes in only one input parameter of the laser, we are able to stabilize complex periodic waveforms and steady state behavior in the laser output. We demonstrate the application of this approach in a diode pumped Nd:/YAG laser system.

Gills, Zelda↗

A model for a continuous-wave iodine laser

A model for a continuous-wave (CW) iodine laser has been developed and compared with the experimental results obtained from a solar-simulator-pumped CW iodine laser. The agreement between the calculated laser power output and the experimental results is generally good for various laser parameters even when the model includes only prominent rate coefficients. The flow velocity dependence of the output power shows that the CW iodine laser cannot be achieved with a flow velocity below 1 m/s for the present solar-simulator-pumped CW iodine laser system.

Hwang, In H.↗

Chaotic microcavity laser with high quality factor and unidirectional output

We demonstrate a chaotic microcavity laser whose quality is comparable to typical nonchaotic microcavity lasers, yet it has the unique characteristic of unidirectional output. The cavity shape is a disk with the boundary defined by a curve called limacon of Pascal. For a lasing mode of volume less than 0.2 {mu}m{sup 3}, the measured quality factor is 23 000. The record-high quality and small modal volume result in extremely low-lasing threshold. The spontaneous emission coupling efficiency is approximately 6% and is the reported value for a chaotic microcavity laser. All the lasing modes have one output beam in the same direction with a divergence angle less than 40 deg. This universal directionality is determined by the chaotic ray dynamics in the open cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct solar-pumped iodine laser amplifier

The improvement on the collection system of the Tarmarack Solar Simulator beam was attemped. The basic study of evaluating the solid state laser materials for the solar pumping and also the work to construct a kinetic model algorithm for the flashlamp pumped iodine lasers were carried out. It was observed that the collector cone worked better than the lens assembly in order to collect the solar simulator beam and to focus it down to a strong power density. The study on the various laser materials and their lasing characteristics shows that the neodymium and chromium co-doped gadolinium scandium gallium garnet (Nr:Cr:GSGG) may be a strong candidate for the high power solar pumped solid state laser crystal. On the other hand the improved kinetic modeling for the flashlamp pumped iodine laser provides a good agreement between the theoretical model and the experimental data on the laser power output, and predicts the output parameters of a solar pumped iodine laser.

Han, Kwang S.↗