Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Prototype Laboratory Concept

The prototype laboratory concept was developed to simplify the laboratory design process, and should be considered for use as a new laboratory design methodology. Many developing countries lack adequate public and animal health laboratories and typically do not have the economic means and the design and construction expertise to build a laboratory on their own. These countries rely on international sponsors to provide the funds necessary to design and construct a laboratory. However, these international sponsors are often located far away, making travel back and forth difficult, which leads to an increase in overall costs and delays for the project. The prototype laboratory concept and design methodology were developed to streamline the design process, saving time and money, while also minimizing the number of errors that typically arise using a traditional design process by providing well considered design decisions in advance of the project. By solving numerous detailed design issues early, this methodology will allow the time, attention and energies of the design team to be focused on addressing the specific needs of the end users, the unique design challenges related to a given site and scientific program, and the biosafety and biosecurity risks associated with the scientific activities planned to be conducted in the facility. While the concept could be expanded to cover other types of laboratories to date, it has primarily focused on supporting the implementation of good laboratory design best practices for infectious disease diagnostic and research laboratories for both the human and animal health sectors. This report presents the laboratory design concept and details associated with the modular layouts. It builds on the work previously provided in the interim prototype laboratory concept report delivered to the Cooperative Biological Engagement Program (CBEP) at the Defense Threat Reduction Agency (DTRA) in 2014. This report includes a number of revised and additional module layouts, more detailed information regarding laboratory finishes and equipment, engineering service information, electrical and lighting layouts, plumbing service information and two mechanical service options for each prototype module. Additionally, this report also includes a description of a cost estimating tool that will accompany this report and allow funding agencies to generate an approximate cost for the construction of a laboratory that utilizes the prototype laboratory concept modules. This report is intended to serve a complete document and includes all relevant information from the 2014 prototype laboratory concept report.

42 ENGINEERING↗

STS-102 Expedition 2 Increment and Science Briefing

Merri Sanchez, Expedition 2 Increment Manager, John Uri, Increment Scientist, and Lybrease Woodard, Lead Payload Operations Director, give an overview of the upcoming activities and objectives of the Expedition 2's (E2's) mission in this prelaunch press conference. Ms. Sanchez describes the crew rotation of Expedition 1 to E2, the timeline E2 will follow during their stay on the International Space Station (ISS), and the various flights going to the ISS and what each will bring to ISS. Mr. Uri gives details on the on-board experiments that will take place on the ISS in the fields of microgravity research, commercial, earth, life, and space sciences (such as radiation characterization, H-reflex, colloids formation and interaction, protein crystal growth, plant growth, fermentation in microgravity, etc.). He also gives details on the scientific facilities to be used (laboratory racks and equipment such as the human torso facsimile or 'phantom torso'). Ms. Woodard gives an overview of Marshall Flight Center's role in the mission. Computerized simulations show the installation of the Space Station Remote Manipulator System (SSRMS) onto the ISS and the installation of the airlock using SSRMS. Live footage shows the interior of the ISS, including crew living quarters, the Progress Module, and the Destiny Laboratory. The three then answer questions from the press.

Source record↗

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of Oci

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI↗

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of OCI

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI, PACE, LSF, PSF, Stray-light, Contrast, Cross-↗

Chemical Hygiene Program

The Chemical Management Team is responsible for ensuring compliance with the OSHA Laboratory Standard. The program at Lewis Research Center (LeRC) evolved over many years to include training, developing Standard Operating Procedures (SOPS) for each laboratory process, coordinating with other safety and health organizations and teams at the Center, and issuing an SOP binder. The Chemical Hygiene Policy was first established for the Center. The Chemical Hygiene Plan was established and reviewed by technical, laboratory and management for viability and applicability to the Center. A risk assessment was conducted for each laboratory. The laboratories were prioritized by order of risk, higher risk taking priority. A Chemical Management Team staff member interviewed the lead researcher for each laboratory process to gather the information needed to develop the SOP for the process. A binder containing the Chemical Hygiene Plan, the SOP, a map of the laboratory identifying the personal protective equipment and best egress, and glove guides, as well as other guides for safety and health. Each laboratory process has been captured in the form of an SOP. The chemicals used in the procedure have been identified and the information is used to reduce the number of chemicals in the lab. The Chemical Hygiene Plan binder is used as a training tool for new employees. LeRC is in compliance with the OSHA Standard. The program was designed to comply with the OSHA standard. In the process, we have been able to assess the usage of chemicals in the laboratories, as well as reduce or relocate the chemicals being stored in the laboratory. Our researchers are trained on the hazards of the materials they work with and have a better understanding of the hazards of the process and what is needed to prevent any incident. From the SOP process, we have been able to reduce our chemical inventory, determine and implement better hygiene procedures and equipment in the laboratories, and provide specific training to our employees. As a result of this program, we are adding labeling to the laboratories for emergency responders and initiating a certified chemical user program.

Mayor, Antoinette C.↗

A Low Cost Remote Sensing System Using PC and Stereo Equipment

A system using a personal computer, speaker, and a microphone is used to detect objects, and make crude measurements using a carrier modulated by a pseudorandom noise (PN) code. This system can be constructed using a personal computer and audio equipment commonly found in the laboratory or at home, or more sophisticated equipment that can be purchased at reasonable cost. We demonstrate its value as an instructional tool for teaching concepts of remote sensing and digital signal processing.

Campbell, Joel F.↗

Portable Neutron Sensors for Emergency Response Operations

This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps for neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

The NASA Space Radiation Laboratory

The Space Radiation Element (SRE) of the Human Research Program (HRP) aims to establish a robust biospecimen and tissue sharing collection (BTSC) to improve sample collection, tracking, access, distribution, and usability to maximize scientific return with intention. Future missions to the Moon, Mars, and beyond will require the appropriate characterization and mitigation of the many of the health risks associated with cosmic radiation exposure. An ongoing partnership between the National Aeronautics and Space Agency (NASA) and the Office of Science for the U.S. Department of Energy (DOE) has established the NASA Space Radiation Laboratory (NSRL) at the DOE Brookhaven National Laboratory (BNL) to create a space radiation ground-analog. NSRL provides the capability to use simulated space radiation with high energy ion beams for assessment of biological outcomes relevant space radiation risks as well as electronics testing for avionics safety. Current NSRL irradiation capabilities include a variety of exposure variables available for experimental needs: - Up to approximately 10 Gy/min dose-rates with a 20 × 20 cm 2 beam area. - Down to several hundred particles within a 60 × 60 cm 2 beam area. - Dose fractionation across multiple days is also possible. - For most radiobiology experiments the exposure structure, referred to as “spills”, has a 4 second repetition time where ions are extracted uniformly during a 0.3-0.4 second spill, followed by a ~3.6 second recovery time when the beam is off. - Both single or mixed-beam field irradiations are possible including a full 33-beam GCRSim and 6-beam SimGCRSim. Biological experiment capabilities: Two labs for Cell/tissue culture procedures can be conducted in two lab spaces with a separate lab available for sample processing that contains two chemical fume hoods. Sixteen fully equipped cell culture laboratories are available in the NSRL’s Long Term Support area in the Medical Building. The current vivarium configuration can support approximately 8,000 rodents/year for animal-based experiments. The NSRL area animal husbandry system includes five caging racks with 48 spaces in each coupled to a ventilation/filtration system in largest room, and two smaller rooms with conventional caging systems. Schedule: The NSRL is nominally open for experiment scheduling during three runs per year; Spring (March – May), Summer (May - June), and Fall (Sept – Nov). NASA funding is not required for biological and electronic testing experiments at the NSRL.

Jason M Weeks↗

Radiative Heating for MSL Entry: Verification of Simulations from Ground Test to Flight Data

The heat shield of the Mars Science Laboratory (MSL) was equipped with thermocouplestacks to measure in-depth heating of the thermal protection system during atmosphericentry. The heat load derived from the thermocouples in the stagnation region was found tobe 33 lower than corresponding post-flight predictions of convective heating alone. It washypothesized that this difference could be attributed to radiation from the shock-heated gas,a mechanism not considered in post-flight analyses of flow fields. In order to test thehypothesis and quantify the contribution of shock-layer radiation to total surface heating,ground tests and simulations (both flow and radiation) were performed at several pointsalong the best-estimated entry trajectory of MSL. The present paper provides anassessment of the quality of the radiation model and its impact to stagnation point heating.Although the impact of radiative heating is shown to be significant, it only accounts for 43of the discrepancy. Additional factors behind the remaining discrepancy are discussed.

Aeroheating↗

Workstations and gloveboxes for space station

Lockheed Missiles and Space Company is responsible for designing, developing, and building the Life Sciences Glovebox, the Laboratory Sciences Workbench, and the Maintenance Workstation plus 16 other pieces of equipment for the U.S. Laboratory Module of the Space Station Freedom. The Laboratory Sciences Workbench and the Maintenance Workstation were functionally combined into a double structure to save weight and volume which are important commodities on the Space Station Freedom. The total volume of these items is approximately 180 cubic feet. These workstations and the glovebox will be delivered to NASA in 1994 and will be launched in 1995. The very long lifetime of 30 years presents numerous technical challenges in the areas of design and reliability. The equipment must be easy to use by international crew members and also easy to maintain on-orbit. For example, seals must be capable of on-orbit changeout and reverification. The stringent contamination requirements established for Space Station Freedom equipment also complicate the zero gravity glovebox design. The current contamination control system for the Life Sciences Glovebox and the Maintenance Workstation is presented. The requirement for the Life Sciences Glovebox to safely contain toxic, reactive, and radioactive materials presents challenges. Trade studies, CAD simulation techniques and design challenges are discussed to illustrate the current baseline conceptual designs. Areas which need input from the user community are identified.

Junge, Maria↗

Solution‐Phase Metathesis of Li 3 N and FeCl 3 to Synthesize Fe 2 N/Fe 3 N Nanoparticles

Soft magnetic materials play key roles in the flow of energy in electrically driven machines and power conversion electronics, and there is a great need for improvements in their magnetic properties to provide the right combination of high saturation magnetization, low coercivity, and high permeability. Most phases of iron nitride (Fe x N) are soft magnetic materials with these characteristics, but they exist as numerous phases which are not all stoichiometric compounds. While the production and magnetic properties of the different phases of bulk iron nitride are well known, accessing phase‐pure nanoscale iron nitride consistently remains a challenge. Most methods for the synthesis of iron nitride nanoparticles require complicated apparatus to achieve high‐temperature nitriding of nanoparticle precursors with gaseous nitrogen sources such as ammonia. The first solution‐phase metathesis reaction between FeCl 3 and Li 3 N in oleylamine is developed to directly synthesize Fe 2 N/Fe 3 N nanoparticles, requiring only a fume hood, glove box, standard chemistry laboratory glassware, and equipment. Finally, the ≈10–15 nm spheres display nearly soft magnetic behavior with a saturation magnetization ≈50–60 A m 2 kg −1 , coercivities between 40–50 kA m −1 , and susceptibility values from 0.0001–0.0006 m 3 kg −1 , well within the ranges reported with other published Fe x N nanoparticle synthesis methods.

iron nitride↗

A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and longterm variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic.

54 ENVIRONMENTAL SCIENCES↗

Large aperture Fizeau interferometer commissioning and preliminary measurements of a long x-ray mirror at European X-ray Free Electron Laser

The European XFEL (X-ray Free Electron Laser) is a large facility under construction in Hamburg, Germany. It will provide a transversally fully coherent x-ray radiation with outstanding characteristics: high repetition rate (up to 2700 pulses with a 0.6 ms long pulse train at 10 Hz), short wavelength (down to 0.05 nm), short pulse (in the femtoseconds scale), and high average brilliance (1.6 ⋅ 10{sup 25} (photons s{sup −1} mm{sup −2} mrad{sup −2})/0.1% bandwidth). The beam has very high pulse energy; therefore, it has to be spread out on a relatively long mirror (about 1 m). Due to the very short wavelength, the mirrors need to have a high quality surface on their entire length, and this is considered very challenging even with the most advanced polishing methods. In order to measure the mirrors and to characterize their interaction with the mechanical mount, we equipped a metrology laboratory with a large aperture Fizeau interferometer. The system is a classical 100 mm diameter commercial Fizeau, with an additional expander providing a 300 mm diameter beam. Despite the commercial nature of the system, special care has been taken in the polishing of the reference flats and in the expander quality. We report the first commissioning of the instrument, its calibration, and performance characterization, together with some preliminary results with the measurement of a 950 mm silicon substrate. The intended application is to characterize the final XFEL mirrors with nanometer accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a standard capture efficiency test method for residential kitchen ventilation

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality standards. However, airflow alone does not show how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood indoor air quality performance is capture efficiency -- the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. The current article summarizes the development of a range hood capture efficiency test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ZPAL v.1.0.0

SAND2024-01003O ZPAL is a Python software development kit designed for use by network automation engineers. It is an application programming interface (API) wrapper that is compatible with ZPE System's Nodegrid API. ZPE produces networking equipment. ZPAL simplifies connections to the ZPE Nodegrid API and makes configuration changes on the associated networking equipment. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hill, Roscoe↗

Addendum to the Closure Report for Corrective Action Unit 484: Surface Debris, Waste Sites, and Burn Area, Tonopah Test Range, Nevada (Revision 0)

Corrective Action Unit (CAU) 484 Streamlined Approach for Environmental Restoration (SAFER) activities called for the identification and remediation of surface hot spot depleted uranium (DU) with some excavation to determine the vertical extent of contamination (NNSA/NSO, 2004). During the CAU 484 SAFER investigation (conducted November 2003 through August 2007), approximately 50 locations containing DU were identified on Antelope Lake. All but four locations (CA-1, SA-5-9, SA-12-15, and SA-4) were remediated. Figure 1-1 shows locations of the four use restriction (UR) sites. The four locations were determined to have failed the SAFER conceptual site model assumption of a small volume hot spot. Two of the locations (CA-1 and SA-5-9) were excavated to depths of 3.5 to 7 feet (ft) below ground surface (bgs), and a third location (SA-12-15) with a footprint of 30 by 60 ft was excavated to a depth of 0.5 ft. At the fourth site (SA-4), the discovery of unexploded ordnance (UXO) halted the excavation due to potential safety concerns. Remediation activities on Antelope Lake resulted in the removal of approximately 246 cubic yards (yd3) of DU-impacted soil from the four UR sites; however, Kiwi surveys confirmed that residual DU contamination remained at each of the four sites. (The Kiwi was a Remote Sensing Laboratory [RSL] vehicle equipped with a data-acquisition system and four sodium iodide gamma detectors. Surveys were conducted with the vehicle moving at a rate of approximately 10 miles per hour with the gamma detectors positioned 14 to 28 inches [in.] above the ground surface [NNSA/NSO, 2004]).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of LANL Capabilities for Fabrication of TREAT Conversion Fuel

This report estimates costs and schedule associated with scale up and fabrication of a low-enriched uranium (LEU) core for the Transient Reactor Test Facility (TREAT) reactor. This study considers facilities available at Los Alamos National Laboratory, facility upgrades, equipment, installation and staffing costs. Not included are costs associated with raw materials and off-site shipping. These estimates are considered a rough of magnitude. At this time, no specifications for the LEU core have been made and the final schedule needed by the national program. The estimate range (+/-100%) reflects this large uncertainty and is subject to change as the project scope becomes more defined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Oak Ridge National Laboratory Support of Non-light Water Reactor Technologies: Capabilities Assessment for NRC Near-term Implementation Action Plans for Non-light Water Reactors

The Oak Ridge National Laboratory (ORNL) has a rich history of support for light water reactor (LWR) and non-LWR technologies. The ORNL history involves operation of 13 reactors at ORNL including the graphite reactor dating back to World War II, two aqueous homogeneous reactors, two molten salt reactors (MSRs), a fast-burst health physics reactor, and seven LWRs. Operation of the High Flux Isotope Reactor (HFIR) has been ongoing since 1965. Expertise exists amongst the ORNL staff to provide non-LWR training; support evaluation of non-LWR licensing and safety issues; perform modeling and simulation using advanced computational tools; run laboratory experiments using equipment such as the liquid salt component test facility; and perform in-depth fuel performance and thermal-hydraulic technology reviews using a vast suite of computer codes and tools. Summaries of this expertise are included in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗