Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Model simulations of continuous ion injection into electron-beam ion source trap with slanted electrostatic mirror

The efficiency of trapping ions in an electron-beam ion source (EBIS) is of primary importance for many applications requiring operations with externally produced ions: RIA breeders, ion sources, and traps. At the present time, the most popular method of ion injection is pulsed injection, when short bunches of ions get trapped in a longitudinal trap while traversing the trap region. Continuous trapping is a challenge for EBIS devices because mechanisms which reduce the longitudinal ion energy per charge in a trap (cooling with residual gas, energy exchange with other ions, and ionization) are not very effective, and accumulation of ions is slow. A possible approach to increase trapping efficiency is to slant the mirror at the end of the trap which is opposite to the injection end. A slanted mirror will convert longitudinal motion of ions into transverse motion, and, by reducing their longitudinal velocity, prevent these ions from escaping the trap on their way out. The trade-off for the increased trapping efficiency this way is an increase in the initial transverse energy of the accumulated ions. The slanted mirror can be realized if the ends of two adjacent electrodes, drift tubes, which act as an electrostatic mirror, are machined to produce a slanted gap, rather than an upright one. Applying different voltages to these electrodes will produce a slanted mirror. The results of two-dimensional (2D) and three-dimensional (3D) computer simulations of the ion injection into an EBIS are presented using simplified models of an EBIS with conical (2D simulations) and slanted (3D simulations) mirror electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of the performance of an ion shutter for drift tubes in atmospheric pressure ion mobility spectrometry: Computer models and experimental findings

Ion mobility spectra are initiated when ions, derived from a sample, are pulsed or injected through ion shutters into a drift region. The effect on signal intensity from electric fields arising from the shutter grids (E{sub s}) and a superimposed electric field of the drift tube (E{sub d}) was determined experimentally and simulated computationally for ion motion at ambient pressure. The combination of these two fields influenced shutter performance in three ways: (1) intensity of an ion peak was suppressed by increased current in the baseline due to continuous leakage of ions into the drift region from insufficient E{sub s} to block ion motion when needed, at a given value of E{sub d}; (2) the ion shutter provided maximum peak intensity with some optimal ratio of E{sub s}/E{sub d} when ions were fully blocked except using the injection time; (c) the signal intensity was reduced when the blocking voltage of the ion shutter exceeded this optimal E{sub s}/E{sub d} ratio from ion depletion at the shutter grids. The optimal ratio from the computer models was equal to 1.50, whereas a value of 2.50 was obtained from the experimental findings. This difference was attributed to nonideal geometry with the grids of the shutter and the conducting elements in the drift tube establishing both E{sub s} and E{sub d}. As both the experimental and modeling results demonstrated, a mobility dependence of ion yield from the ionization source was found to cause a mobility dependent ion signal at the collector electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Donnan-Manning theory for selective ion partition and transport in ion exchange membrane

The use of ion exchange membranes (IEMs) for electrochemical ion-ion separation leverages the selectivity of the IEMs toward like-charged species via valence difference and/or other ion membrane interactions. A mechanistic model that relates selectivity with membrane structural and chemical properties is lacking in the literature. Here, in this study, we extend the Manning’s counter-ion condensation model for describing ion partition and ion mobility inside IEMs to mixed salts scenarios. We evaluate the extended Donnan-Manning model against experimental data from literature and compare the performance the Donnan-Manning model to that of the ideal Donnan model and the Donnan-Affinity model. Our analysis shows that, despite its structural complexity, the Donnan-Manning model has less fitting parameters than the Donnan-Affinity model and generally outperforms the two other models in predicting counter-ion and co-ion partition. With the assumption of a higher mobility of condensed ions than that of uncondensed ions, the generalized Manning’s model can also predict counter-ion mobility selectivity for cation exchange membranes, but its performance for predicting mobility selectivity for anion exchange membranes is still unsatisfactory.

42 ENGINEERING↗

The effect of ion pairing on speciation and transport in ion exchange membranes at varying hydration levels: A four-state model

Understanding ion pairing in ion exchange membranes (IEMs) is essential for advancing IEM applications in energy and environmental technologies. Here, this study introduces a four-state molecular dynamics model to quantify speciation and transport within Nafion-117, specifically examining the role of ion pairing in monovalent and divalent counterions (NaCl, Na 2 SO 4 , and MgSO 4 ). By analyzing radial distribution functions (RDFs) and molecular snapshots, we distinguish ion pairing modes and classify counterions into four states: condensed counterion, condensed ion pair, free ion pair, and free counterion. A key finding is that while divalent counterions (e. g., Mg 2+ ) maintain stable speciation across hydration levels, monovalent counterions (e.g., Na + ) show notable speciation shifts with hydration. Both monovalent and divalent counterions are not diffusive when condensed onto the polymer (sorbed to membrane functional groups). In contrast, free counterions are diffusive across all hydration levels. To evaluate the overall diffusivity of counterions, four-state fractions and diffusivities are computed, each contributing to counterion transport. The condensed/free ion speciation for multivalent sulfate salts aligns with previous revisions to the Donnan-Manning framework that include ion pairing, thereby validating its relevance to established membrane theories. The four-state model's diffusivity results support several current ion exchange assumptions, including that the condensed counterions are immobile, while uncondensed counterions are mobile. The four-state model offers insights into contact ion pairing within IEMs, highlighting its potential even when undetected in aqueous solution experiments. This work advances the theoretical understanding of counterion speciation in IEMs while identifying model limitations that suggest avenues for refinement, such as distinguishing water-mediated ion pairs between fully hydrated ions.

Ion exchange membranes↗

Electron cyclotron resonance ion sources in use for heavy ion cancer therapy

The use of electron cyclotron resonance (ECR) ion sources for producing ion beams for heavy ion cancer therapy has been established for more than ten years. After the Heavy Ion Medical Accelerator (HIMAC) at Chiba, Japan started therapy of patients with carbon ions in 1994 the first carbon ion beam for patient treatment at the accelerator facility of GSI was delivered in 1997. ECR ion sources are the perfect tool for providing the required ion beams with good stability, high reliability, and easy maintenance after long operating periods. Various investigations were performed at GSI with different combinations of working gas and auxiliary gas to define the optimal beam conditions for an extended use of further ion species for the dedicated Heidelberg Ion Beam Therapy (HIT) facility installed at the Radiological University Hospital Heidelberg, Germany. Commercially available compact all permanent magnet ECR ion sources operated at 14.5 GHz were chosen for this facility. Besides for {sup 12}C{sup 4+} these ion sources are used to provide beams of {sup 1}H{sub 3}{sup 1+}, {sup 3}He{sup 1+}, and {sup 16}O{sup 6+}. The final commissioning at the HIT facility could be finished at the end of 2006.

43 PARTICLE ACCELERATORS↗

Development of Compact Electron Cyclotron Resonance Ion Source with Permanent Magnets for High-Energy Carbon-Ion Therapy

Heavy-ion cancer treatment is being carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) with 140 to 400 MeV/n carbon ions at National Institute of Radiological Sciences (NIRS) since 1994. At NIRS, more than 4,000 patients have been treated, and the clinical efficiency of carbon ion radiotherapy has been demonstrated for many diseases. A more compact accelerator facility for cancer therapy is now being constricted at the Gunma University. In order to reduce the size of the injector (consists of ion source, low-energy beam transport and post-accelerator Linac include these power supply and cooling system), an ion source requires production of highly charged carbon ions, lower electric power for easy installation of the source on a high-voltage platform, long lifetime and easy operation. A compact Electron Cyclotron Resonance Ion Source (ECRIS) with all permanent magnets is one of the best types for this purpose. An ECRIS has advantage for production of highly charged ions. A permanent magnet is suitable for reduce the electric power and cooling system. For this, a 10 GHz compact ECRIS with all permanent magnets (Kei2-source) was developed. The maximum mirror magnetic fields on the beam axis are 0.59 T at the extraction side and 0.87 T at the gas-injection side, while the minimum B strength is 0.25 T. These parameters have been optimized for the production of C{sup 4+} based on experience at the 10 GHz NIRS-ECR ion source. The Kei2-source has a diameter of 320 mm and a length of 295 mm. The beam intensity of C{sup 4+} was obtained to be 618 e{mu}A under an extraction voltage of 30 kV. Outline of the heavy ion therapy and development of the compact ion source for new facility are described in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Energy Grazing Ion-Scattering From Alkali-Halide Surfaces: A Novel Approach To C-14 Detection

Carbon-14 labeled compounds are widely used in the pharmaceutical industry, e.g., as tracers to determine the fate of these compounds in vivo. Conventional accelerator mass spectrometry (AMS) is one approach that offers sufficiently high sensitivity to avoid radiological waste and contamination issues in such studies, but requires large, expensive facilities that are usually not solely dedicated to this task. At the ORNL Multicharged Ion Research Facility (MIRF) we are exploring a small size, low cost alternative to AMS for biomedical {sup 14}C tracer studies that utilizes ECR-ion-source-generated keV-energy-range multicharged C beams grazingly incident on an alkali halide target, where efficient negative ion production by multiple electron capture takes place. By using C ion charge states of +3 or higher, the molecular isobar interference at mass 14, e.g. {sup 12}CH{sub 2} and {sup 13}CH, is eliminated. The negatively charged ions in the beam scattered from the alkali halide surface are separated from other scattered charge states by two large acceptance ({approx}15 msr) stages of electrostatic analysis. The N-14 isobar interference is thus removed, since N does not support a stable negative ion. Initial results for C-14 detection obtained using C-14 enriched CO{sub 2} from ANSTO will be described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of ion abundances on electromagnetic ion cyclotron wave growth rate in the vicinity of the plasmapause

Electromagnetic ion cyclotron (EMIC) waves in multi-ion species plasmas propagate in branches. Except for the branch corresponding to the heaviest ion species, which has only a resonance at its gyrofrequency, these branches are bounded below by a cutoff frequency and above by a resonant gyrofrequency. The condition for wave growth is determined by the thermal anisotropies of each ion species, j, which sets an upper bound, ω{sub j}{sup ∗}, on the wave frequency below which that ion species contributes positively to the growth rate. It follows that the relative positions of the cutoffs and the critical frequencies ω{sub j}{sup ∗} play a crucial role in determining whether a particular wave branch will be unstable. The effect of the magnetospheric ion abundances on the growth rate of each branch of the EMIC instability in a model where all the ion species have kappa velocity distributions is investigated by appealing to the above ideas. Using the variation of the cutoff frequencies predicted by cold plasma theory as a guide, optimal ion abundances that maximise the EMIC instability growth rate are sought. When the ring current is comprised predominantly of H{sup +} ions, all branches of the EMIC wave are destabilised, with the proton branch having the maximum growth rate. When the O{sup +} ion abundance in the ring current is increased, a decrease in the growth rate of the proton branch and cyclotron damping of the helium branch are observed. The oxygen branch, on the other hand, experiences an increase in the maximum growth rate with an increase in the O{sup +} ion abundance. When the ring current is comprised predominantly of He{sup +} ions, only the helium and oxygen branches of the EMIC wave are destabilised, with the helium branch having the maximum growth rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rate theory of solvent exchange and kinetics of Li{sup +} − BF{sub 4}{sup −}/PF{sub 6}{sup −} ion pairs in acetonitrile

In this paper, we describe our efforts to apply rate theories in studies of solvent exchange around Li{sup +} and the kinetics of ion pairings in lithium-ion batteries (LIBs). We report one of the first computer simulations of the exchange dynamics around solvated Li{sup +} in acetonitrile (ACN), which is a common solvent used in LIBs. We also provide details of the ion-pairing kinetics of Li{sup +}-[BF{sub 4}] and Li{sup +}-[PF{sub 6}] in ACN. Using our polarizable force-field models and employing classical rate theories of chemical reactions, we examine the ACN exchange process between the first and second solvation shells around Li{sup +}. We calculate exchange rates using transition state theory and weighted them with the transmission coefficients determined by the reactive flux, Impey, Madden, and McDonald approaches, and Grote-Hynes theory. We found the relaxation times changed from 180 ps to 4600 ps and from 30 ps to 280 ps for Li{sup +}-[BF{sub 4}] and Li{sup +}-[PF{sub 6}] ion pairs, respectively. These results confirm that the solvent response to the kinetics of ion pairing is significant. Our results also show that, in addition to affecting the free energy of solvation into ACN, the anion type also should significantly influence the kinetics of ion pairing. These results will increase our understanding of the thermodynamic and kinetic properties of LIB systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MEASUREMENT AND CALCULATION OF ABSOLUTE SINGLE AND MULTIPLE CHARGE EXCHANGE CROSS SECTIONS FOR Fe {sup q} {sup +} IONS IMPACTING H{sub 2}O

Charge exchange (CE) plays a fundamental role in the collisions of solar- and stellar-wind ions with lunar and planetary exospheres, comets, and circumstellar clouds. Reported herein are absolute cross sections for single, double, triple, and quadruple CE of Fe {sup q} {sup +} (q = 5-13) ions with H{sub 2}O at a collision energy of 7q keV. One measured value of the pentuple CE is also given for Fe {sup 9} {sup +} ions. An electron cyclotron resonance ion source is used to provide currents of the highly charged Fe ions. Absolute data are derived from knowledge of the target gas pressure, target path length, and incident and charge-exchanged ion currents. Experimental cross sections are compared with new results of the n-electron classical trajectory Monte Carlo approximation. The radiative and non-radiative cascades following electron transfers are approximated using scaled hydrogenic transition probabilities and scaled Auger rates. Also given are estimates of cross sections for single capture, and multiple capture followed by autoionization, as derived from the extended overbarrier model. These estimates are based on new theoretical calculations of the vertical ionization potentials of H{sub 2}O up to H{sub 2}O{sup 10+}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Systematic Ion Source Parameter Assessment by Automated Determination of the Distribution of Ion Acceptance (DIA) Using APLI

The determination of the spatially resolved ion signal with atmospheric pressure laser ionization (APLI), which was introduced as distribution of ion acceptance (DIA), serves as a valuable tool for the understanding of complex and highly dynamical conditions in modern atmospheric pressure (AP) ion sources. DIA provides information about fluid dynamics, ion transport, and ion transformation processes in such sources and is an ideal basis for the validation of numerical models of the dynamics in the ion source enclosure. We present a fully automated setup for DIA measurements, which enabled us to acquire a comprehensive dataset of over 700 individual DIA measurements in a commercial AP ion source (Bruker Multi Purpose Ion Source, MPIS). Ion source parameters as voltages, gas heater temperatures and gas flows, were varied, and the effect of those parameters on the DIA of a chemically inert analyte, pyrene, was systematically investigated. It is shown that the response of the DIA is nonlinear and that gas dynamics largely dominates the ion transport in the ion source. Particularly, the position of the heated nebulizer, which is used to introduce one of two gas flows and the analyte into the ion source chamber, had a profound effect on the DIA. This suggests that the gas dynamics in the source switches between different states. The now available comprehensive DIA dataset reveals such critical effects and will guide further numerical modeling efforts to understand the details of the dynamics of ions in the source chamber. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of a reconnection-driven runaway ion tail in a reversed field pinch plasma

While reconnection-driven ion heating is common in laboratory and astrophysical plasmas, the underlying mechanisms for converting magnetic to kinetic energy remain not fully understood. Reversed field pinch discharges are often characterized by rapid ion heating during impulsive reconnection, generating an ion distribution with an enhanced bulk temperature, mainly perpendicular to magnetic field. In the Madison Symmetric Torus, a subset of discharges with the strongest reconnection events develop a very anisotropic, high energy tail parallel to magnetic field in addition to bulk perpendicular heating, which produces a fusion neutron flux orders of magnitude higher than that expected from a Maxwellian distribution. Here, we demonstrate that two factors in addition to a perpendicular bulk heating mechanism must be considered to explain this distribution. First, ion runaway can occur in the strong parallel-to-B electric field induced by a rapid equilibrium change triggered by reconnection-based relaxation; this effect is particularly strong on perpendicularly heated ions which experience a reduced frictional drag relative to bulk ions. Second, the confinement of ions varies dramatically as a function of velocity. Whereas thermal ions are governed by stochastic diffusion along tearing-altered field lines (and radial diffusion increases with parallel speed), sufficiently energetic ions are well confined, only weakly affected by a stochastic magnetic field. High energy ions traveling mainly in the direction of toroidal plasma current are nearly classically confined, while counter-propagating ions experience an intermediate confinement, greater than that of thermal ions but significantly less than classical expectations. The details of ion confinement tend to reinforce the asymmetric drive of the parallel electric field, resulting in a very asymmetric, anisotropic distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using support vector machines to improve elemental ion identification in macromolecular crystal structures

A method to automatically identify possible elemental ions in X-ray crystal structures has been extended to use support vector machine (SVM) classifiers trained on selected structures in the PDB, with significantly improved sensitivity over manually encoded heuristics. In the process of macromolecular model building, crystallographers must examine electron density for isolated atoms and differentiate sites containing structured solvent molecules from those containing elemental ions. This task requires specific knowledge of metal-binding chemistry and scattering properties and is prone to error. A method has previously been described to identify ions based on manually chosen criteria for a number of elements. Here, the use of support vector machines (SVMs) to automatically classify isolated atoms as either solvent or one of various ions is described. Two data sets of protein crystal structures, one containing manually curated structures deposited with anomalous diffraction data and another with automatically filtered, high-resolution structures, were constructed. On the manually curated data set, an SVM classifier was able to distinguish calcium from manganese, zinc, iron and nickel, as well as all five of these ions from water molecules, with a high degree of accuracy. Additionally, SVMs trained on the automatically curated set of high-resolution structures were able to successfully classify most common elemental ions in an independent validation test set. This method is readily extensible to other elemental ions and can also be used in conjunction with previous methods based on a priori expectations of the chemical environment and X-ray scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL (invited)

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e {mu}A of O{sup 7+}, 505 e {mu}A of Xe{sup 20+}, 306 e {mu}A of Xe{sup 27+}, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

43 PARTICLE ACCELERATORS↗

An electron cyclotron resonance ion source based low energy ion beam platform

To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced collective focusing of intense neutralized ion beam pulses in the presence of weak solenoidal magnetic fields

In this study, the design of ion drivers for warm dense matter and high energy density physics applications and heavy ion fusion involves transverse focusing and longitudinal compression of intense ion beams to a small spot size on the target. To facilitate the process, the compression occurs in a long drift section filled with a dense background plasma, which neutralizes the intense beam self-fields. Typically, the ion bunch charge is better neutralized than its current, and as a result a net self-pinching (magnetic) force is produced. The self-pinching effect is of particular practical importance, and is used in various ion driver designs in order to control the transverse beam envelope. In the present work we demonstrate that this radial self-focusing force can be significantly enhanced if a weak (B~100 G) solenoidal magnetic field is applied inside the neutralized drift section, thus allowing for substantially improved transport. It is shown that in contrast to magnetic self-pinching, the enhanced collective self-focusing has a radial electric field component and occurs as a result of the overcompensation of the beam charge by plasmaelectrons, whereas the beam current becomes well-neutralized. As the beam leaves the neutralizing drift section, additional transverse focusing can be applied. For instance, in the neutralized drift compression experiments (NDCX) a strong (several Tesla) final focus solenoid is used for this purpose. In the present analysis we propose that the tight final focus in the NDCX experiments may possibly be achieved by using a much weaker (few hundred Gauss) magnetic lens, provided the ion beam carries an equal amount of co-moving neutralizing electrons from the preceding drift section into the lens. In this case the enhanced focusing is provided by the collective electrondynamics strongly affected by a weak applied magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of ion-to-electron mass ratio on the evolution of ion beam driven instability in particle-in-cell simulations

In particle-in-cell (PIC) simulation studies of ion-ion two-stream instability, a reduced ion-to-electron mass ratio is often employed to save computation time. It is tacitly assumed that electrons do not play a significant role in the evolution of the instability as the ion-ion interactions are regarded to occur on time scales much slower than the response time of electrons. However, as the effect of such a reduced mass ratio has never been closely examined, we have studied the evolution of the ion beam driven instability using a one-dimensional electrostatic PIC code by rescaling the simulation parameters according to the ion-electron mass ratio. We made a reference simulation run with a mass ratio of 100 first and compared the results to the simulation results using the real mass ratio with parameters rescaled from those of the reduced mass ratio. External electric fields were applied in these simulations, which accelerated the electrons and excited an ion acoustic type instability, forming electron phase space holes. Merging of the electron holes affected the ion dynamics significantly when the reduced mass ratio was used, while the interplay between the electron and ion dynamics became different depending on the rescaling methods in the case of the real mass ratio. Another simulation test with much enhanced external electric field results in similar mass ratio dependence. The present simulation results clearly show that the reduced mass ratio should be used cautiously in PIC simulations as the electron dynamics can modify the ion instabilities significantly by affecting the ion motions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗