Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrated charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Boltzmann Transport Code Update: Parallelization and Integrated Design Updates

The on going efforts at developing a web site for radiation analysis is expected to result in an increased usage of the High Charge and Energy Transport Code HZETRN. It would be nice to be able to do the requested calculations quickly and efficiently. Therefore the question arose, "Could the implementation of parallel processing speed up the calculations required?" To answer this question two modifications of the HZETRN computer code were created. The first modification selected the shield material of Al(2219) , then polyethylene and then Al(2219). The modified Fortran code was labeled 1SSTRN.F. The second modification considered the shield material of CO2 and Martian regolith. This modified Fortran code was labeled MARSTRN.F.

Heinbockel, J. H.↗

The IRAS radiation environment

Orbital flux integration for three selected mission altitudes and geographic instantaneous flux-mapping for nominal flight-path altitude were used to determine the external charged particle radiation predicted for the Infrared Astronomy Satellite. A current field model was used for magnetic field definitions for three nominal circular trajectories and for the geographic mapping positions. Innovative analysis features introduced include (1) positional fluxes as a function of time and energy for the most severe pass through the South Atlantic Anomaly; (2) total positional doses as a function of time and shield thickness; (3) comparison mapping fluxes for ratios of positional intensities to orbit integrated averages; and (4) statistical exposure-time history of a trajectory as a function of energy indicating, in percent of total mission duration, the time intervals over which the instantaneous fluxes would exceed the orbit integrated averages. Results are presented in tables and graphs.

Stassinopoulos, E. G.↗

Soft-error generation due to heavy-ion tracks in bipolar integrated circuits

Both bipolar and MOS integrated circuits have been empirically demonstrated to be susceptible to single-particle soft-error generation, commonly referred to as single-event upset (SEU), which is manifested in a bit-flip in a latch-circuit construction. Here, the intrinsic characteristics of SEU in bipolar (static) RAM's are demonstrated through results obtained from the modeling of this effect using computer circuit-simulation techniques. It is shown that as the dimensions of the devices decrease, the critical charge required to cause SEU decreases in proportion to the device cross-section. The overall results of the simulations are applicable to most integrated circuit designs.

Zoutendyk, J. A.↗

Active pixel sensor array with multiresolution readout

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node. There is also a readout circuit, part of which can be disposed at the bottom of each column of cells and be common to all the cells in the column. The imaging device can also include an electronic shutter formed on the substrate adjacent the photogate, and/or a storage section to allow for simultaneous integration. In addition, the imaging device can include a multiresolution imaging circuit to provide images of varying resolution. The multiresolution circuit could also be employed in an array where the photosensitive portion of each pixel cell is a photodiode. This latter embodiment could further be modified to facilitate low light imaging.

Fossum, Eric R.↗

Numerical integration of kinetic equations.

Relaxation to Maxwellian of Balescu-Lenard equation solved numerically as initial value problem for isotropic distributions of electrons in background of positive charge

MAXWELL DISTRIBUTION↗

Geomagnetic Cutoff Rigidity Computer Program: Theory, Software Description and Example

The access of charged particles to the earth from space through the geomagnetic field has been of interest since the discovery of the cosmic radiation. The early cosmic ray measurements found that cosmic ray intensity was ordered by the magnetic latitude and the concept of cutoff rigidity was developed. The pioneering work of Stoermer resulted in the theory of particle motion in the geomagnetic field, but the fundamental mathematical equations developed have 'no solution in closed form'. This difficulty has forced researchers to use the 'brute force' technique of numerical integration of individual trajectories to ascertain the behavior of trajectory families or groups. This requires that many of the trajectories must be traced in order to determine what energy (or rigidity) a charged particle must have to penetrate the magnetic field and arrive at a specified position. It turned out the cutoff rigidity was not a simple quantity but had many unanticipated complexities that required many hundreds if not thousands of individual trajectory calculations to solve. The accurate calculation of particle trajectories in the earth's magnetic field is a fundamental problem that limited the efficient utilization of cosmic ray measurements during the early years of cosmic ray research. As the power of computers has improved over the decades, the numerical integration procedure has grown more tractable, and magnetic field models of increasing accuracy and complexity have been utilized. This report is documentation of a general FORTRAN computer program to trace the trajectory of a charged particle of a specified rigidity from a specified position and direction through a model of the geomagnetic field.

Smart, D. F.↗

Preliminary Pioneer-10 intensity gradients of galactic cosmic rays.

Selected data from the University of Chicago charged-particle telescope on the Pioneer-10 spacecraft bound for Jupiter have been examined and compared with data from the University of Chicago charged-particle telescopes on the Earth satellites IMP-5 and IMP-6 at 1 AU to derive a preliminary integral intensity gradient for relativistic galactic protons and helium nuclei. The preliminary value obtained is (4.5 plus or minus 1.0) percent per AU over the radial range 1-2.8 AU. Preliminary differential gradients also have been obtained for the energy range 29-67 MeV per nucleon.

Mckibben, R. B.↗

Sensors and detectors in NASA's future missions

Advances in electronics are responsible for major improvements in NASA's sensing and detection capabilities for future space missions. Technologies such as charge-transfer devices, tunable diode lasers, millimeter and submillimeter wave solid-state receiver components, large-scale circuit integration, new electronic materials and processing techniques, and novel detector electronics are contributing to the goal of a tenfold increase in the capacity of data collection from future platforms and will be used for space exploration and utilization.

Rubin, B.↗

Three-dimensional relativistic field-electron interaction in a multicavity high-power klystron. Part 2: Working Equations

A high power multicavity klystron amplifier was designed and a computation package containing all equations and procedures needed is presented. The rigorously derived three dimensional relativistic axisymmetric equations of motion are used to compute the bunched current and the induced RF gap voltage for all interaction cavities except the input and second cavities, where the linear space charge wave theory data are employed in order to reduce the computation time. Both distance step and time step integration methods are used to compute the Fourier coefficients of both the beam current and induced current.

Kosmahl, H. G.↗

Recent developments in semiconductor research

Recent findings drawn from various laboratories focused toward a new understanding of the nature of crystal growth and how impurities are incorporated or excluded from the lattice were considered. From these findings a heuristic approach is given for improving the uniformity and charge carrier concentration of thin semiconductor films. Such improvement is considered essential to achieve respectable yield on large scale integrated circuits. A tentative conclusion is drawn which indicates that if the host compound crystal reactants are provided to the growing crystal surface in a reasonably stoichiometric manner, it is virtually impossible to include impurities into a growing crystal surface held at a sufficiently low temperature; impurities are incorporated into the crystal by gettering action of crystal defects located one and two monlayers beneath the growing surface. Devices in 3-5 semiconductors based on heterojunctions and two dimensional electron gases are noted and reliability concerns are voiced. Alternatives and novel device structures such as truly single crystal high quality silicon on insulator and beta silicon carbide devices are presented.

Yoder, M. N.↗

Chaos and nonlinear dynamics of single-particle orbits in a magnetotaillike magnetic field

The properties of charged-particle motion in Hamiltonian dynamics are studied in a magnetotaillike magnetic field configuration. It is shown by numerical integration of the equation of motion that the system is generally nonintegrable and that the particle motion can be classified into three distinct types of orbits: bounded integrable orbits, unbounded stochastic orbits, and unbounded transient orbits. It is also shown that different regions of the phase space exhibit qualitatively different responses to external influences. The concept of 'differential memory' in single-particle distributions is proposed. Physical implications for the dynamical properties of the magnetotail plasmas and the possible generation of non-Maxwellian features in the distribution functions are discussed.

Chen, J.↗

Galactic Cosmic Radiation (GCR) Measurements Made by M-42 Active Dosimeters on NASA Balloon Flights (New Mexico & Antarctica) Resemble Levels Expected at Mars

Mimicking galactic cosmic radiation (GCR) is difficult with ground-based simulations and experimental results are limited by facility constraints. In the past year, we flew two consecutive missions on large NASA scientific balloons (to ~ 38 km altitude) launched from New Mexico (6.5-hr flight) and Antarctica (32-d flight) and will report GCR doses comparable to levels expected at the equatorial Mars surface. Measurements were made in collaboration with the DLR and utilizing the M-42 active radiation dosimeter developed for use on Artemis 1. The M-42 instrument stores data in flash memory, records charged particles over a substantial part of the trapped proton and the GCR LET spectrum, and can be easily integrated into payloads due to its compact size (182 x 44 x 22 mm; 237 g) and internal battery (up to 6 weeks of operation). Our presentation will provide an overview of the two recent balloon missions (payload description; flight profiles), and summarize the radiation data collected in the middle stratosphere, highlighting how robust, real GCR exposures can be achieved without needing to fly orbital or deep space experiments.

radiation↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Buccino, Dustin R↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Oudrhiri, Kamal↗

GLAST Large Area Telescope - Design and Optimization of Anti-Coincidence Detector

The gamma-ray Large Area Telescope (GLAST) with LAT as its main instrument is now in the final stage of integration into the spacecraft and is scheduled for launch in November 2007. The Anti-Coincidence Detector (ACD) is one of the key telescope systems, providing much of the charged particle background rejection. Taking into account the required large ACD detecting area (more than 8 sq m) and high efficiency of relativistic single charged particle detection (greater than 0.9997 over the entire ACD area), the design was very challenging. It included the choice of conceptual design, extensive Monte Carlo simulations and trade-offs of the experimental techniques, supported by numerous bench tests, custom electronics, careful mechanical design and extensive mechanical/environmental tests, precision fabrication and finally the decisive step- final integration and system-level tests. Currently the LAT (with ACD integrated) is integrated into the spacecraft and undergoing the numerous spacecraft-level tests

Moiseev, Alexander↗

Ionisation from the 3s sub-level of highly charged ions

Scaled electron-impact cross sections are calculated for ionization from the 3s sublevel of hydrogenic ions with Z equal infinity by use of the Born exchange or the Coulomb-Born Oppenheimer approximation (which is exact, apart from relativistic corrections, in this limit). The results are fitted to an analytic expression which goes into the correct Bethe approximation result at high energies and which can readily be integrated over a Maxwellian electron velocity distribution to obtain collision rates. These results permit calculation of the approximate cross section and collision rate for ionization from the 3s sublevel of any highly charged ion with Z/N larger than approximately 2. Results obtained by the described procedure for Fe-14(+) and Fe-15(+) are compared with results obtained by other procedures.

Golden, L. B.↗

Cryogenic Nitrogen Thermosyphon Developed and Characterized

A two-phase nitrogen thermosyphon was developed at the NASA Glenn Research Center to efficiently integrate a cryocooler into an insulated liquid-nitrogen-filled tank as part of an advanced development zero-boiloff (ZBO) ground test. NASA Marshall Space Flight Center's (MSFC) Advanced Space Transportation Program supported this test to improve the performance of in-space propulsion system concepts. Recent studies (ref. 1) have shown significant mass reductions and other advantages when incorporating active cooling in a ZBO configuration, enabling consideration of high-performing cryogenic propellants for long-duration applications in space. Active cooling was integrated via a thermosyphon, made of copper, 42 in. (1070 mm) long with an inner diameter of 0.436 in. (11 mm). It was charged with nitrogen to 225 psia at 300 K, which provided a fill ratio of 15 percent. The temperatures and heat flows through the thermosyphon were monitored during the startup phase of the ZBO test, and steady-state tests were conducted over a range of increasing and decreasing heat flows. The results also were compared with the initial design calculations and with results for a similar thermosyphon. They show that the thermal resistance of the thermosyphon was one-half of that expected--0.2 K/W at a heat flow of 8.0 W. The design calculations also showed that this resistance can be made relatively constant over a wider range of heat flows by making the ratio of evaporator area to condenser area 3:1. The better-than-expected results will translate into reduced integration loss for the ZBO concept.

Plachta, David W.↗

Cosmic ray induced errors in I2L microprocessors and logic devices

Large-scale integrated (LSI) devices fabricated with integrated injection logic (I2L) were studied by both heavy ion experiments and device analysis to determine the upset threshold, the charge collection volumes and ultimately the probability for upset in the galactic cosmic ray spectrum. The devices studied, the SEP9900A, the SBP9989 and the P-Code generator were fabricated by Texas Instruments, Inc.

Price, W. E.↗