Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focused upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for Monitoring around Marine Renewable Energy Converters: Workshop Final Report

To better understand the state of instrumentation and capabilities for monitoring around marine energy converters, the U.S. Department of Energy directed Pacific Northwest National Laboratory and the Northwest National Marine Renewable Energy Center at the University of Washington to convene an invitation-only workshop of experts from around the world to address instrumentation needs.

16 TIDAL AND WAVE POWER↗

In-Pile Instrumentation Multi- Parameter System Utilizing Photonic Fibers and Nanovision

An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In addition to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY17 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under the in-pile instrumentation work package supporting the transient testing program. These activities were performed in direct support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a complete summary of all work, which is of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers with emphasis on transient testing applications. Development activities are focused on devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. A brief summary of activities and accomplishments is first provided for each major activity. Detailed reports are presented in appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MethodOpt: a Shiny-based graphical user interface for multivariate optimization of sampling and analytical instrumentation

Method optimization is an important step in producing useful data in various experimental settings involving the use of sampling and analytical instrumentation, such as gas-chromatography mass-spectrometry or other analytical techniques. However, traditional optimization techniques often lack the sophistication of more modern optimization techniques developed in areas of applied mathematics. A graphical user interface has been developed that implements a multivariate, multi-objective optimization technique for spectra-generating sampling and analytical instrumentation, which saves substantial time and resources compared to the more traditional approaches to method development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gap Assessment on Sensors and Instrumentation for Advanced Reactors

The Sensor Technologies for Advanced Reactors Virtual Workshop—sponsored by the Gateway for Accelerated Innovation in Nuclear (GAIN), the Electric Power Research Institute, and the Nuclear Energy Institute—was held to exchange information on sensors and sensor technologies of interest to advanced nuclear technology developers, commercial instrument suppliers, and sensor researchers from Department of Energy (DOE) national laboratories, universities, and industry. The workshop objectives were to discuss measurement requirements and sensor needs for advanced reactor concepts, understand current national laboratory capabilities and accelerated development approaches for sensors and instrumentation, and identify gaps so as to inform applicable DOE Office of Nuclear Energy (DOE-NE) research programs. Due to the complexity of holding group discussions on individual gaps, a survey was sent to workshop participants, and personalized one-on-one feedback sessions were held to elicit additional information. Summaries of these sessions are provided in this gap assessment report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensors and Instrumentation 2022 Summary of Accomplishments

The Advanced Sensors and Instrumentation (ASI) program is the element of the Nuclear Energy Enabling Technologies (NEET) initiative dedicated to Instrumentation and Control (I&C) technology. This document collects in the form of summaries the research accomplishments presented at the program 2022 Annual Review meeting, which was held virtually between October 24 and October 27, 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensors & Instrumentation FY24 Summary of Accomplishments

The Advanced Sensors and Instrumentation (ASI) program is the element of the Nuclear Energy Enabling Technologies (NEET) initiative dedicated to Instrumentation and Control (I&C) technology. This document collects in the form of summaries the research accomplishments presented at the program 2024 Annual Review meeting, which was held virtually between November 4 & 6-7, 2024.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SERENA: Particle Instrument Suite for Determining the Sun-Mercury Interaction from BepiColombo

The ESA-JAXA BepiColombo mission to Mercury will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric particle dynamics at Mercury as well as their interactions with solar wind, solar radiation, and interplanetary dust. The particle instrument suite SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) is flying in space on-board the BepiColombo Mercury Planetary Orbiter (MPO) and is the only instrument for ion and neutral particle detection aboard the MPO. It comprises four independent sensors: ELENA for neutral particle flow detection, Strofio for neutral gas detection, PICAM for planetary ions observations, and MIPA, mostly for solar wind ion measurements. SERENA is managed by a System Control Unit located inside the ELENA box. In the present paper the scientific goals of this suite are described, and then the four units are detailed, as well as their major features and calibration results. Finally, the SERENA operational activities are shown during the orbital path around Mercury, with also some reference to the activities planned during the long cruise phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Flying Cages in Traveling Wave Ion Mobility: Influence of the Instrumental Parameters on the Topology of the Host–Guest Complexes

Supramolecular mass spectrometry has emerged in the last decade as an orthogonal method to access, at the molecular level, the structures of noncovalent complexes extracted from the condensed phase to the rarefied gas phase using electrospray ionization. It is often considered that the soft nature of the ESI source confers to the method the capability to generate structural data comparable to those in the condensed phase. In the present paper, using the ammonium ion/cucurbituril combination as a model system, we investigate using ion mobility and computational chemistry the influence of the instrumental parameters on the topology, i.e., internal versus external association, of gaseous host/guest complex ions. MS and theoretical data are confronted to condensed phase data derived from nuclear magnetic resonance spectroscopy to assess whether the instrumental parameters can play an insidious role when trying to derive condensed phase data from mass spectrometry results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An overview of polarized neutron instruments and techniques in Asia Pacific

Polarized neutron scattering is an indispensable tool for exploring a vast range of scientific phenomena. With its dynamic scientific community and significant governmental support as well as the rapid economic growth, the Asia–Pacific region has become a key player in the worldwide neutron scattering arena. From traditional research reactors to cutting-edge spallation neutron sources, this region is home to a myriad of advanced instruments offering a wide range of polarized neutron capabilities. This review aims to provide a comprehensive overview of the development and current status of polarized neutron instruments and techniques in the Asia–Pacific region, emphasizing the important role of the Asia–Pacific region in shaping the landscape of global polarized neutron scattering development.

47 OTHER INSTRUMENTATION↗

Nuclear characterization of a general-purpose instrumentation and materials testing location in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950s, provided thousands of transient irradiations before being placed in standby in 1994, and resumed operations in 2017 in order to reclaim its crucial role in nuclear-heated safety research. The latter half of TREAT’s historic operation was best known for integral-scale testing of fuel specimens under postulated reactor plant accident conditions, while TREAT’s earlier history included extensive simpler phenomena identification tests that elucidated fundamental behaviors and paved the way for these integral-scale tests. Advances in modern computational capabilities and a resurgence of interest in novel reactor technology have created an opportunity for emphasizing modernized science-based and separate effects test capabilities once again at TREAT. An innovative approach to this type of testing has been developed to leverage minor radioactivity built-in during brief TREAT irradiations in low activation hardware to facilitate handling for materials and instrumentation testing. This capability, termed the Minimal Activation Retrievable Capsule Holder (MARCH) irradiation vehicle system, will be used for inaugural fueled experiments in TREAT’s modern era as well as novel approaches to study materials undergoing neutron irradiation and instrumentation development and qualifications. This paper describes a comprehensive nuclear characterization, obtained via computational modeling, of the test position in the MARCH system. Though directly applicable to the MARCH system, the results also provide general quantification of the nuclear performance of the reactor and potential test materials, crucial for evaluating potential experiment design and response in TREAT. The neutron and photon flux environment was calculated via MCNP with ENDF/B-VII.1 nuclear data. Wire heating rate and DPA calculations were also performed and evaluated using historic TREAT test data. Furthermore, these calculations were performed to provide steady-state baseline reference values typical in both half- and full-slotted TREAT core configurations, enabling design scoping analysis prior to development of more specific design testing needs and transient testing experimentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking sensor fusion capabilities of an integrated instrumentation package

Quantifying and mitigating environmental risks introduced by marine energy conversion systems requires a variety of sensors (active acoustic, passive acoustic, and optical). The operation of these sensors must satisfy three directives to be effective: (1) do not alter the environment through operation of sensors; (2) capture rare events; and (3) do not accrue unmanageable volumes of low-value data. This requires integrating sensors into a single package, rather than operating them independently. The Adaptable Monitoring Package is an integrated instrumentation package that combines a multibeam sonar, acoustic camera, current profiler, optical cameras, and an array of hydrophones. The capabilities and limitations of the AMP sensors were benchmarked using cooperative targets, and real-time target tracking and detection was used to detect opportunistic targets (e.g., diving birds, seals). During an initial deployment, automatic detection of opportunistic targets achieved a 58% true positive rate and a 99% true negative rate (100% corresponding to an ideal system in both cases). In post-processing, target tracking data were used to evaluate automatic target classification capabilities using a k-nearest neighbor algorithm. Findings suggest that real-time target classification should be possible and enable integrated instrumentation systems to meet the monitoring needs of marine energy deployments.

16 TIDAL AND WAVE POWER↗

Simulation of differential die-away instrument’s response to asymmetrically burned spent nuclear fuel

Here, previous simulation studies of Differential Die–Away (DDA) instrument’s response to active interrogation of spent nuclear fuel from a pressurized water reactor (PWR) yielded promising results in terms of its capability to accurately measure or estimate basic spent fuel assembly (SFA) characteristics, such as multiplication, initial enrichment (IE) and burn-up (BU) as well as the total plutonium content. These studies were however performed only for a subset of idealized SFAs with a symmetric BU with respect to its longitudinal axis. Therefore, to complement the previous results, additional simulations have been performed of the DDA instrument’s response to interrogation of asymmetrically burned spent nuclear fuel in order to determine whether detailed assay of SFAs from all 4 sides will be necessary in real life applications or whether a cost and time saving single sided assay could be used to achieve results of similar quality as previously reported in case of symmetrically burned SFAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗