Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRINIDI: Time-of-Flight Resonance Imaging With Neutrons for Isotopic Density Inference

Accurate reconstruction of 2D and 3D isotope densities is a desired capability with great potential impact in applications such as evaluation and development of next-generation nuclear fuels. Neutron time-of-flight (TOF) resonance imaging offers a potential approach by exploiting the characteristic neutron absorption spectra of each isotope. However, it is a major challenge to compute quantitatively accurate images due to a variety of confounding effects such as severe Poisson noise, background scatter, beam non-uniformity, absorption non-linearity, and extended source pulse duration. We present the TRINIDI algorithm which is based on a two-step process in which we first estimate the neutron flux and background counts, and then reconstruct the areal densities of each isotope and pixel. Both components are based on the inversion of a forward model that accounts for the highly non-linear absorption, energy-dependent emission profile, and Poisson noise, while also modeling the substantial spatio-temporal variation of the background and flux. Further, to do this, we formulate the non-linear inverse problem as two optimization problems that are solved in sequence. We demonstrate on both synthetic and measured data that TRINIDI can reconstruct quantitatively accurate 2D views of isotopic areal density that can then be reconstructed into quantitatively accurate 3D volumes of isotopic volumetric density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave-Optics Simulation Framework of Fourier Transform Holography with XMCD

We present a wave-optics simulation framework, implemented within the SRW, for modeling FTH with XMCD contrast. The framework propagates coherent, circularly polarized X-ray wavefronts from an undulator source through the sample and optics to the detector, reconstructing real-space images from the resulting holograms. Three principal extensions are introduced: (i) incorporation of polarization-dependent refractive indices in the sample plane, enabling direct simulation of XMCD contrast, (ii) a memory-efficient wavefront-splitting propagation scheme that treats individual apertures independently and coherently combines their fields at detector, and (iii) an integrated reconstruction module that delivers holographic images within the same framework. Together, these advances establish a versatile tool for quantitative exploration of coherence, aperture geometry, and detector sampling, and for the design and interpretation of XMCD-FTH experiments at synchrotron beamlines.

43 PARTICLE ACCELERATORS↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of concrete microstructure using complementarity of X-ray and neutron tomography

The concrete microstructure was successfully reconstructed using the complementarity of X-ray and neutron computed tomography (CT). Neither tomogram alone was found to be suitable to properly describe the microstructure of concrete under this study. However, by merging the information revealed by the two modalities, and using image segmentation, noise reduction, and image registration techniques we reconstruct the concrete microstructure. Void, aggregate, and cement paste phases are successfully captured down to the images' spatial resolution, even though the aggregate consists of multiple minerals. The coarse-aggregate volume fraction of the reconstructed microstructure was similar to that of the mixing proportions. Furthermore, image-based finite element analysis is performed to demonstrate the effects of microstructure on stress concentration and strain localization.

36 MATERIALS SCIENCE↗

MoRE-Brain: Routed Mixture of Experts for Interpretable and Generalizable Cross-Subject fMRI Visual Decoding

Decoding visual experiences from fMRI offers a powerful avenue to understand human perception and develop advanced brain-computer interfaces. However, current progress often prioritizes maximizing reconstruction fidelity while overlooking interpretability, an essential aspect for deriving neuroscientific insight. To address this gap, we propose MoRE-Brain, a neuro-inspired framework designed for high-fidelity, adaptable, and interpretable visual reconstruction. MoRE-Brain uniquely employs a hierarchical Mixture-of-Experts architecture where distinct experts process fMRI signals from functionally related voxel groups, mimicking specialized brain networks. The experts are first trained to encode fMRI into the frozen CLIP space. A finetuned diffusion model then synthesizes images, guided by expert outputs through a novel dual-stage routing mechanism that dynamically weighs expert contributions across the diffusion process. MoRE-Brain offers three main advancements: First, it introduces a novel Mixture-of-Experts architecture grounded in brain network principles for neuro-decoding. Second, it achieves efficient cross-subject generalization by sharing core expert networks while adapting only subject-specific routers. Third, it provides enhanced mechanistic insight, as the explicit routing reveals precisely how different modeled brain regions shape the semantic and spatial attributes of the reconstructed image. Extensive experiments validate MoRE-Brain’s high reconstruction fidelity, with bottleneck analyses further demonstrating its effective utilization of fMRI signals, distinguishing genuine neural decoding from over-reliance on generative priors. Consequently, MoRE-Brain marks a substantial advance towards more generalizable and interpretable fMRI-based visual decoding.

Wei, Yuxiang [Georgia Institute of Technology]↗

CryoDRGN-AI: neural ab initio reconstruction of challenging cryo-EM and cryo-ET datasets

Proteins and other biomolecules form dynamic macromolecular machines that are tightly orchestrated to move, bind, and perform chemistry. Cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET) can access the intrinsic heterogeneity of these complexes and are therefore key tools for understanding their function. However, 3D reconstruction of the collected imaging data presents a challenging computational problem, especially without any starting information, a setting termed ab initio reconstruction. Here, in this study, we introduce cryoDRGN-AI, a method leveraging an expressive neural representation and combining an exhaustive search strategy with gradient-based optimization to process challenging heterogeneous datasets. Using cryoDRGN-AI, we reveal new conformational states in large datasets, reconstruct previously unresolved motions from unfiltered datasets, and demonstrate ab initio reconstruction of biomolecular complexes from in situ data. With this expressive and scalable model for structure determination, we hope to unlock the full potential of cryo-EM and cryo-ET as a high-throughput tool for structural biology and discovery.

Levy, Axel [Stanford Univ., CA (United States); SL↗

System and method for x-ray compatible 2D streak camera for a snapshot multiframe imager

The present disclosure is directed to a snapshot multiframe imager having an aperture element having at least one aperture, an adjacently positioned random mask, an imaging element and a computer. The random mask has a plurality of micron scale apertures and receives light passing through the aperture element, which represents the spatial information from the scene being imaged, and generates a plurality of image frames encoded in a spatial domain. The imaging element may operate in a drift-scan mode receives the encoded image frames and generates a streaked pattern of electrons representing a plurality of images of the scene at a plurality of different times. The computer analyzes the streaked pattern of electrons and mathematically reconstructs the plurality of images.

Dayton, Matthew S.↗

SINGLE: Atomic-resolution structure identification of nanocrystals by graphene liquid cell EM

Analysis of the three-dimensional (3D) structures of nanocrystals with solution-phase transmission electron microscopy is beginning to reveal their unique physiochemical properties. We developed a “one-particle Brownian 3D reconstruction method” based on imaging of ensembles of colloidal nanocrystals using graphene liquid cell electron microscopy. Projection images of differently rotated nanocrystals are acquired using a direct electron detector with high temporal (<2.5 ms) resolution and analyzed to obtain an ensemble of 3D reconstructions. Here, we introduce computational methods required for successful atomic-resolution 3D reconstruction: (i) tracking of the individual particles throughout the time series, (ii) subtraction of the interfering background of the graphene liquid cell, (iii) identification and rejection of low-quality images, and (iv) tailored strategies for 2D/3D alignment and averaging that differ from those used in biological cryo–electron microscopy. Our developments are made available through the open-source software package SINGLE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

47 OTHER INSTRUMENTATION↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

Study of azimuthal anisotropy of $\Upsilon$ (1S) mesons in pPb collisions at $\sqrt{S_{NN}}$ = 8.16 TeV

The azimuthal anisotropy of Image 1 mesons in high-multiplicity proton-lead collisions is studied using data collected by the CMS experiment at a nucleon-nucleon center-of-mass energy of 8.16 TeV. The Image 1 mesons are reconstructed using their dimuon decay channel. The anisotropy is characterized by the second Fourier harmonic coefficients, found using a two-particle correlation technique, in which the Image 1 mesons are correlated with charged hadrons. A large pseudorapidity gap is used to suppress short-range correlations. Nonflow contamination from the dijet background is removed using a low-multiplicity subtraction method, and the results are presented as a function of Image 1 transverse momentum. The azimuthal anisotropies are smaller than those found for charmonia in proton-lead collisions at the same collision energy, but are consistent with values found for Image 1 mesons in lead-lead interactions at a nucleon-nucleon center-of-mass energy of 5.02 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Confronting Large‐Eddy Simulations With Stereo Camera Data by Means of Reconstructed Hemispheric Cloud Size Distributions

High-resolution hemispheric camera images at a meteorological site in western Germany are used to analyze the multi-dimensional spatial characteristics of continental cumulus cloud fields, and to evaluate Large-Eddy Simulations on this aspect. Traditional non-hemispheric cloud-detecting instruments provide additional reference data. The main model-observation comparison focuses on cloud size distributions (CSDs), employing two methods: (a) directly using three-dimensional model fields, direct CSDs, and (b) using rendered hemispheric images of the model fields as produced by a camera simulator based on path-tracing. In the latter method, both the real and rendered images are used to three-dimensionally reconstruct the cloud fields, yielding hemispheric CSDs. Advantages of hemispheric comparisons over more classic approaches include (a) fair comparisons between model and data, and (b) full use of the enhanced resolutions and hemispheric spatial coverage of the camera imagery. Basic evaluation of the simulations demonstrates good agreement on thermodynamic structure and its diurnal cycle. Cloud heights and cloud cover are intercompared between the model, camera data and other instrumentation, providing insight into their structural differences. A consistent alignment is found between the hemispheric CSDs from both the model and the cameras. Power law fits reveal structurally lower exponents in hemispheric CSDs compared to non-hemispheric CSDs, which particularly caution against directly comparing hemispheric CSDs to non-hemispheric distributions. This result is robust for sample size and fitting method. These findings inform future use of hemispheric camera systems for studying cumulus cloud field morphology and model evaluation.

54 ENVIRONMENTAL SCIENCES↗