Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drift-cyclotron loss-cone instability in 3-D simulations of a sloshing-ion simple mirror

The kinetic stability of collisionless, sloshing beam-ion (45° pitch angle) plasma is studied in a three-dimensional (3-D) simple magnetic mirror, mimicking the Wisconsin high-temperature superconductor axisymmetric mirror experiment. The collisional Fokker–Planck code CQL3D-m provides a slowing-down beam-ion distribution to initialize the kinetic-ion/fluid-electron code Hybrid-VPIC, which then simulates free plasma decay without external heating or fuelling. Over 1 – 10 μs, drift-cyclotron loss-cone (DCLC) modes grow and saturate in amplitude. The DCLC scatters ions to a marginally stable distribution with gas-dynamic rather than classical-mirror confinement. Sloshing ions can trap cool (low-energy) ions in an electrostatic potential well to stabilize DCLC, but DCLC itself does not scatter sloshing beam-ions into the said well. Instead, cool ions must come from external sources such as charge-exchange collisions with a low-density neutral population. Manually adding cool ∼1keV ions improves beam-ion confinement several-fold in Hybrid-VPIC simulations, which qualitatively corroborates prior measurements from real mirror devices with sloshing ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

Fast ion studies in the extended high-performance high β P plasma on EAST

Comprehending and optimizing fast ion behaviors is critical for the enhancement of performance in Experimental Advanced Superconducting Tokamak (EAST). This study explores the potential benefits of several factors that can improve the fast ion confinement. First, experiments show the change in the direction of the NBI2 from counter-I p to co-I p leads to a significant reduction in fast ion losses. TRANSP/NUBEAM simulation and tomography results based on fast-ion D-alpha measurements reveal that after the neutral beam injection (NBI) upgrade, the beam ion prompt loss is reduced by approximately 50%. Second, the upgraded ion cyclotron resonant frequency (ICRF) antenna at the N-port features twice the coupling resistance of the original antennas at EAST. This improved ICRF power coupling has enhanced the synergistic heating effect of NBI + ICRF, where the ICRF wave field accelerates beam ions at the harmonics. Experiments demonstrate that NBI + ICRF synergistic not only enhances plasma neutron yield and β P , but also accelerates beam ions to hundreds of keV. Further, the electron density and the neutral beam voltage have been optimized to reduce the fast ion slowing-down time and beam ion losses. Experimental and simulation results indicate that increasing the electron density reduces beam ion losses and enhances the bootstrap current fraction. While higher beam voltage results in a slight decrease in beam power absorption, it can increase the fraction of bootstrap current. With the understanding of these optimization of fast ion confinement, experiments have demonstrated fully non-inductive operation at high density (n e /n G ∼ 0.67, β P ∼ 3.1, β N ∼ 2.1, H 98,y2 ∼ 1.2) even without the support of co-I p beam NBI2. This investigation presents a potential regime to enhance fast ion confinement and extend performance in the high β P plasma for future experiments.

EAST tokamak↗

High Energy ERLs for Electron Cooling

Future electron-ion colliders such as the recently approved eRHIC collide high-intensity ion beams with high current electron beams. The electron beams take advantage of synchrotron radiation to damp emittances but the ion beams must be cooled via some beam-cooling mechanism, including electron cooling. The ion energies are typically a few hundreds of GeV per nucleon. At this energy, a DC cooler powered by an electrostatic accelerator, the preferred cooling approach on existing machines, is not feasible. An ERL, in principle, can provide the high current and brightness to cool these high-brightness ion beams. The beam quality requirements are much different from previous ERLs designs used for FELs. The cooling bunch must be very long to match the ion beam and the relative energy spread must be very small. Incoherent cooling can be enhanced with magnetized beams, but the magnetization must be maintained throughout the ERL. An alternate cooling mechanism, the so-called Coherent Electron Cooling, is, in principle, stronger and can be done with non-magnetized beams. We will present two applications of an ERL to high energy electron cooling and describe some of the technical challenges that must be overcome to operate such an ERL

Benson, Stephen↗

Modeling and design of compact, permanent-magnet transport systems for highly divergent, broad energy spread laser-driven proton beams

Laser-driven (LD) ion acceleration has been explored in a newly constructed short focal length laser beamline at the BELLA petawatt facility (interaction point 2, iP2). For applications utilizing such LD ion beams, a beam transport system is required, which for reasons of compactness be ideally contained within 3 m. While they are generated from a micron-scale source, large divergence and energy spread of LD ion beams present a unique challenge to transporting them compared to beams from conventional accelerators. This study gives an overview of proposed compact transport designs using permanent magnets satisfying different requirements depending on the application for the iP2 laser beamline such as radiation biology, material science, and high-energy density science. These designs are optimized for different parameters such as energy spread and peak proton density according to the application’s need. The various designs consist solely of permanent magnet elements, which can provide high magnetic field gradients on a small footprint. While the field strengths are fixed, we have shown that the beam size is able to be tuned effectively by varying the placement of the magnets. The performance of each design was evaluated based on high-order particle tracking simulations of typical LD proton beams. We also examine the ability of certain configurations to tune and select beam energies, critical for specific applications. A more detailed investigation was carried out for a design to deliver 10 MeV LD accelerated ions for radiation biology applications. With these transport system designs, the iP2 laser beamline is ready to house various application experiments.

43 PARTICLE ACCELERATORS↗

An Electron-Beam Ion-Neutralization Diagnostic for the Scorpius Radiography Accelerator

Electron beam spilling onto the beam pipe can produce positive ions that are accelerated inward into the beam body by its space charge. These ions partially neutralize the space charge, thereby causing the beam to be mismatched to the magnetic fields used for transport. A diagnostic of neutralization effects has been used on present accelerators, and in this note the feasibility of its use on a future accelerator is assessed.

43 PARTICLE ACCELERATORS↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Effect of fabrication processes on BaTiO 3 capacitor properties

There is an increasing desire to utilize complex functional electronic materials such as ferroelectrics in next-generation microelectronics. As new materials are considered or introduced in this capacity, an understanding of how we can process these materials into those devices must be developed. Here, the effect of different fabrication processes on the ferroelectric and related properties of prototypical metal oxide (SrRuO 3 )/ferroelectric (BaTiO 3 )/metal oxide (SrRuO 3 ) heterostructures is explored. Two different types of etching processes are studied, namely, wet etching of the top SrRuO 3 using a NaIO 4 solution and dry etching using an Ar + -ion beam (i.e., ion milling). Polarization-electric-field hysteresis loops for capacitors produced using both methods are compared. For the ion-milling process, it is found that the Ar + beam can introduce defects into the SrRuO 3 /BaTiO 3 /SrRuO 3 devices and that the milling depth strongly influences the defect level and can induce a voltage imprint on the function. Realizing that such processing approaches may be necessary, work is performed to ameliorate the imprint of the hysteresis loops via ex situ “healing” of the process-induced defects by annealing the ferroelectric material in a barium-and-oxygen-rich environment via a chemical-vapor-deposition-style process. This work provides a pathway for the nanoscale fabrication of these candidate materials for next-generation memory and logic applications.

36 MATERIALS SCIENCE↗

Overview of H- radio frequency ion sources for particle accelerators

Particle accelerators are among the most important scientific tools of the modern era. Large accelerator complexes have supported scientific user facilities which have had an enormous societal impact spanning many decades and enabling the work of thousands of scientific users worldwide contributing to many Nobel prizes in physics, biology and chemistry [1]. Many of the large hadron facilities employ accelerator complexes which include cyclotrons, synchrotrons, storage rings, linear or tandem accelerators and deliver ion beams of very high-intensity and/or very high-energy to their user facilities. These accelerator complexes require the injection of high-intensity beams of ions which are produced within an ion source and formed within a plasma or by bombardment of a surface [2]. Increasingly, RF systems are being utilized, to generate these ion-rich plasmas due to their high reliability and minimal use of consumable components. This report will first discuss the basic mechanisms of ion formation and plasma generation as well as some specifics of RF/microwave generators, matching circuits and plasma coupling structures typically employed. A detailed discussion will then be given of the RF-driven negative ion source systems employed by US Spallation Neutron Source as well as those used in similar facilities located around the globe. REFERENCES [1]Vladimir Shiltsev, “Particle beams behind physics discoveries”, Physics Today 73, Issue 4, 32 (2020) [2]Robert Welton et al, “Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations”, Journal of Physics Conf Series, 2244 012045

Welton, Robert F.↗

Physics of beam-driven ion cyclotron emission in the large plasma device

Abstract Ion cyclotron emission (ICE) is widely observed from spatially localised minority energetic ion populations in toroidal magnetically confined fusion (MCF) plasmas, both tokamaks and stellarators. Its spectral structure is typically regular with narrow suprathermal peaks, whose frequency separation matches a local energetic ion cyclotron frequency. Here we report the first computational (fully nonlinear self-consistent kinetic particle-in-cell code) and analytical (linear magnetoacoustic cyclotron instability (MCI)) studies of ICE observations from cylindrical plasmas contained in the Large Plasma Device (LAPD). Because LAPD is cylindrical, the plasma physics giving rise to the observed ICE spectrum necessarily excludes toroidal effects. Our approach, previously successful for toroidal plasma ICE, assumes slab geometry and hence is well adapted to LAPD. ICE from LAPD is strongly electrostatic, as distinct from electromagnetic, and is driven by 15 keV beam ions for which the ratio of perpendicular speed to the local Alfven speed, v ⊥ / v A , is 0.15, lower than in MCF plasmas from which beam-driven ICE has previously been observed. Our results are in good agreement with these observations. There is congruence between simulated ICE spectra, obtained in the saturated nonlinear regime of our computations, and observed ICE spectra; the underlying physics is essentially the same as in toroidal plasmas; and there is alignment with linear analytical theory where appropriate. The present work establishes a mapping from the cylindrical LAPD ICE observations to toroidal MCF ICE observations. The LAPD spectra are instances of beam-driven MCI-type ICE in its sub-Alfvenic, predominantly electrostatic manifestation, which has precedents in MCF stretching back to the 1990s. An interesting corollary is that, for many purposes, ICE in toroidal MCF plasmas ‘might as well’ be occurring in a cylinder.

Samant, O. (ORCID:0000000226055363)↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗

A Focused Ion Beam-Scanning Transmission Electron Microscopy with Energy-Dispersive X-ray Spectroscopy Study on Technetium Incorporation within Iron Oxides through Fe(OH) 2 (s) Mineral Transformation

Incorporation of Tc(IV) into iron oxide/hydroxide minerals has been explored and proposed as a promising pathway to preventing Tc(IV) reoxidation to environmentally mobile pertechnetate (TcO 4 - ) and improving long-term immobilization of radioactive technetium-99 (Tc). However, visual evidence evaluating the distribution of Tc(IV) incorporated within iron oxide/hydroxide phases has not been available, until now, despite potential implications on Tc(IV) stability within the host phase. For the purpose of this study Tc(IV) incorporation into iron oxide/hydroxide phases was facilitated via Fe(OH) 2 (s) oxidation and mineral transformation to magnetite (Fe 3 O 4 ). Focused ion beam - scanning transmission electron microscopy equipped with energy-dispersive X-ray spectroscopy (FIB/STEM-EDS) methods were then combined with X-ray diffraction and absorption spectroscopy techniques to characterize and visually demonstrate that, for the first time, Tc(IV) is heterogeneously incorporated into different iron oxide/hydroxide phases as Tc(IV)-incorporated magnetite and/or TcO 2 ·2H 2 O(s) via different incorporation mechanisms. Heterogeneous distribution of Tc(IV) in magnetite suggests either (i) TcO4- is reduced quickly at the magnetite surface and then encapsulated into magnetite during continued octahedral crystal growth, or (ii) Tc(IV) alternatively partitioned into multiple layers of a blocky, plate-like morphological magnetite structure showing stratified Tc. With limited Tc-hematite (Fe 2 O 3 ) incorporation, the results suggest that TcO 2 ·2H 2 O(s) is formed and mainly associated/embedded in fibrous nanometer-sized polycrystalline hematite. This work highlights the power of modern state-of-the-art FIB/STEM-EDS approach to provide essential visual insights of the Tc-iron oxide/hydroxide incorporation and generate reliable mechanism-informed designs for waste forms relying on Tc mineral incorporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗

Measuring recoiling nucleons from the nucleus with the future Electron Ion Collider

Short range correlated nucleon-nucleon (NN) pairs are an important part of the nuclear ground state. They are typically studied by scattering an electron from one nucleon in the pair and detecting its spectator correlated partner (spectator-nucleon tagging). The Electron Ion Collider (EIC)should be able to detect these nucleons, since they are boosted to high momentum in the lab frame by the momentum of the ion beam. To determine the feasibility of these studies with the planned EIC detector configuration, we have simulated quasi-elastic scattering for two electron and ion beam energy configurations: 5 GeV electrons and 41 GeV/A ions, and 10 GeV electrons and 110 GeV/A ions. We show that the knocked-out and recoiling nucleons can be detected over a wide range of initial nucleon momenta. We also show that these measurements can achieve much larger momentum transfers than current fixed target experiments. By detecting both low and high initial-momentum nucleons,the EIC will provide the data that should allow scientists to definitively show if the EMC effect and short-range correlation are connected, and to improve our understanding of color transparency

Hauenstein, F. (ORCID:0000000212652212)↗