Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

One-dimensional stitching interferometry assisted by a triple-beam interferometer

In this work, we proposed for stitching interferometry to use a triple-beam interferometer to measure both the distance and the tilt for all sub-apertures before the stitching process. The relative piston between two neighboring sub-apertures is then calculated by using the data in the overlapping area. Comparisons are made between our method, and the classical least-squares principle stitching method. Our method can improve the accuracy and repeatability of the classical stitching method when a large number of sub-aperture topographies are taken into account. Our simulations and experiments on flat and spherical mirrors indicate that our proposed method can decrease the influence of the interferometer error from the stitched result. The comparison of stitching system with Fizeau interferometry data is about 2 nm root mean squares and the repeatability is within ± 2.5 nm peak to valley.

47 OTHER INSTRUMENTATION↗

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

47 OTHER INSTRUMENTATION↗

Micrometer-accuracy 2D displacement interferometer with plasmonic metasurface resonators

In this Letter, a high-accuracy, two-dimensional displacement sensor is proposed, designed, and demonstrated based on the concept of an extrinsic Fabry–Perot Interferometer. The sensor is composed of two bundled single-mode optic fibers in parallel and two plasmonic metasurface resonators inscribed on a gold substrate via a focused ion beam. The fiber end surface and the metasurface are in parallel with a small cavity between. The cavity change or Z -component displacement is determined from the pattern of interference fringes. The X -component displacement, perpendicular to the Z component, is identified from wavelength-selective metasurface resonators, which possess unique resonant wavelengths due to different nanostructure designs. The sensor was calibrated with six displacements applied through a three-axis precision linear stage. Test results indicated that the proposed interferometer can measure displacements with a maximum error of 5.4 µm or 2.2%.

Guo, Chuanrui (ORCID:0000000271412972)↗

A Laboratory Atom Interferometer Instrument

We have demonstrated a laboratory based, high bandwidth atom interferometer instrument and have performed an incipient gravity measurement with a fractional statistical uncertainty of ag/g = 4.4 x 10 -6 where g is the acceleration due to gravity. We have designed, constructed, and optimised numerous laser systems for this purpose, most notably a powerful Raman laser (12 W at 780 nm) which will allow large momentum transfer and large detuning interferometry to be carried out at high bandwidth for the first time. This experiment is a general purpose test bed for exploring the fundamental limitations of atom interferometer techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Atom Interferometer Accelerometer

This report presents the theoretical effort to model and simulate the atom-interferometer accelerometer operating in a highly mobile environment. Multitudes of non-idealities may occur in such a rapidly-changing environment with a large acceleration whose amplitude and direction both change quickly. We studied the undesired effect of high mobility in the atom-interferometer accelerator in a detailed model and a simulator. The undesired effects include the atom cloud's movement during Raman pulses, the Doppler effect due to the relative movement between the atom-cloud and the supporting platform, the finite atom cloud temperature, and the lateral movement of the atom cloud. We present the relevant feed-forward mitigation strategies for each identified non-ideality to neutralize the impact and obtain accurate acceleration measurements.

43 PARTICLE ACCELERATORS↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MAGIS-100 Experiment and a Future, Kilometer-scale Atom Interferometer

The dearth of signals unambiguously attributable to WIMP dark matter motivates exploring new parameter space, particularly the ultra-light dark matter (ULDM) regime, where the signal is not scattering events but wave phenomena. The proliferation of quantum technologies has enabled searches for ULDM at previously inaccessible sensitivity. One such technology is atom interferometry which can measure time-dependent fluctuations in the energy spacing of atoms as well as in the light-travel time across the apparatus, enabling searches for ULDM and gravitational waves, respectively. In this talk, I will review the science case for long baseline atom interferometers, such as MAGIS-100 at Fermilab, provide an update on the experiment’s status, and discuss the need for a future, kilometer-scale atom interferometer which would achieve unprecedented sensitivity to ULDM and gravitational waves in the “Mid-Band” region between LIGO and LISA.

Temples, Dylan J. [Fermilab] (ORCID:00000001601725↗

Ultraviolet interferometer

Grazing-incidence multi-beam interferometer /GIMBI/ obtains high resolution spectroscopic data from ultraviolet region of the spectrum without use of concave diffraction gratings or partially reflecting coatings. Device produces interference pattern whose fringes may be sharper than those produced by a Fabry-Perot interferometer.

Day, R. A.↗

Liquid-helium-cooled Michelson interferometer

Interferometer serves as a rocket-flight spectrometer for examination of the far infrared emission spectra of astronomical objects. The double beam interferometer is readily adapted to make spectral scans and for use as a detector of discrete line emissions.

Augason, G. C.↗

Interferometer using RF switching matrix

Radio frequency switching technique for single receiver and data processing channel to be used for phase movement measurement is discussed. Components of interferometer radio frequency unit, X-band receiver, and interferometer data processing unit are illustrated. Elimination of major measurement error source is described.

Vanvleet, R. N.↗

Development and testing of the infrared interferometer spectrometer for the Mariner Mars 1971 spacecraft

The design, development and testing of the infrared interferometer spectrometer is reported with emphasis on the unique features of the Mariner instrument as compared to previous IRIS instruments flown on the Nimbus meteorological research satellites. The interferometer functions in the spectral range from 50 microns to 6.3 microns. A noise equivalent radiance of 0.5 X 10 to the -7th power W/sq cm/ster/cm has been achieved. Major improvements that were implemented included the cesium iodide beamsplitter and electronic features to suppress the effect of vibration on the Michelson mirror motion and digital filtering through the summation of increased sampling of the infrared signal. A bit error detection and correction scheme was also implemented in order to recover the science data with a higher level of confidence over the telecommunication link.

Hanel, R. H.↗

Jones's matrix representation of optical instruments. II - Fourier interferometers /spectrometers and spectropolarimeters/.

Our method of matrix synthesis of optical components and instruments is applied to the derivation of Jones's matrices appropriate for Fourier interferometers (spectrometers and spectropolarimeters). These matrices are obtained for both the source beam and the detector beam. In the course of synthesis, Jones's matrices of the various reflectors (plane mirrors; retroreflectors: roofed mirror, trihedral and prism cube corner, cat's eye) used by these interferometers are also obtained.

Fymat, A. L.↗

The M.I.T. Ku-band radio interferometer.

The construction of a Ku-band radio interferometer and some preliminary observations are reported. The interferometer was built for the purpose of mapping discrete radio sources like the Crab Nebula, Cassiopeia A, and Cygnus A. It has two 8-ft parabolic antennas operating at 17.128 GHz. The maximum baseline of 100 m corresponds to a resolution of 35 sec of arc. A PDP-8 computer is incorporated in the system and is used for pointing, tracking, delay compensation, and real-time data analysis. The phase stability of the system was better than 10 deg over a period of 2 hours. Consistent fringe components were obtained from the Crab Nebula with a baseline set at 8 m.

Papadopoulos, G. D.↗

Three-Josephson-junction interferometer.

An analysis shows that a three-Josephson-junction asymmetric-feed quantum interferometer has increased magnetic field sensitivity and amplitude deviation over those of a two-junction interferometer. The critical current at zero applied field is lower than the critical current at zero flux in the interference loop.

Stuehm, D. L.↗

Electron density measurements of an inhomogeneous plasma using millimeter wave Fabry-Perot interferometers.

The electron density of a laboratory generated inhomogeneous plasma was measured using 60-90, GHz flat-plate and 150 GHz semi-confocal Fabry-Perot interferometers. The plasma was a negative glow-type and had a measured parabolic electron density profile. An analytical comparison between the derived equations of electron density for an assumed homogeneous plasma slab and an inhomogeneous plasma with parabolic distribution showed that the slab approximation was valid for such a profile. Comparison of measured values of electron density with those using X-band and K-band interferometers for the same plasma indicated good agreement.

Kendall, B. M.↗

Stability of fringe counting interferometers

Two configurations of an automatic bidirectional, fringe-counting corner-cube interferometer are compared. They differ only in the method of quadrature phase introduction. The one using polarization coding has good phase stability at optical path differences as large as 955 mm, the one using adjacent beams has such poor phase stability as to render it useless at path differences greater than 700 mm. A useful well-defined alignment procedure is given for the corner-cube interferometer.

Edgerton, J. W.↗