Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INFRARED SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Infrared transmission spectra of Sea of Fertility regolith

Transmission spectra in the 2-25 micrometer region were obtained for samples of lunar regolith returned by the Luna 16 automatic station. A comparison of the Luna 16, Apollo 11, and Apollo 12 samples showed that the infrared transmission spectra of regolith samples from the mare regions are similar and characteristic of basic basaltic rocks. The absorption bands show up in the vibration region of the SiO4 groups. No water and OH groups were found in the samples based on the spectrum. Spectra of regolith samples calcined at 1000C showed changes that can be interpreted as changes in the spectra of irradiated crystals (especially distinctly for the Luna 16 samples).

Akhmanova, M. V.↗

Modeling the infrared cascade spectra of small PAHs: the 11.2 μm band

The profile of the 11.2 μm feature of the infrared (IR) cascade emission spectra of polycyclic aromatic hydrocarbon (PAH) molecules is investigated using a vibrational anharmonic method. Several factors are found to affect the profile including: the energy of the initially absorbed ultraviolet (UV) photon, the density of vibrational states, the anharmonic nature of the vibrational modes, the relative intensities of the vibrational modes, the rotational temperature of the molecule, and blending with nearby features. Each of these factors is explored independently and influence either the red or blue wing of the 11.2 μm feature. The majority impact solely the red wing, with the only factor altering the blue wing being the rotational temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Mid-Infrared Absorption Spectra of Neutral PAHs in Dense Interstellar Clouds

Polycyclic aromatic hydrocarbons (PAHs) are common throughout the universe and are expected to be present in dense interstellar clouds. In these environments, some P.4Hs may be present in the gas phase, but most should be frozen into ice mantles or adsorbed onto dust grains and their spectral features are expected to be seen in absorption. Here we extend our previous work on the infrared spectral properties of the small PAH naphthalene (C10H8) in several media to include the full mid-infrared laboratory spectra of 11 other PAHs and related aromatic species frozen in H2O ices. These include the molecules 1,2-dihydronaphthalene, anthracene, 9,1O-dihydroanthracene, phenanthrene, pyrene, benzo[e]pyrene, perylene, benzo(k)fluoranthene, pentacene, benzo[ghi]perylene, and coronene. These results demonstrate that PAHs and related molecules, as a class, show the same spectral behaviors as naphthalene when incorporated into H2O-rich matrices. When compared to the spectra of these same molecules isolated in inert matrices (e.g., Ar or N2), the absorption bands produced when they are frozen in H2O matrices are broader (factors of 3-10), show small position shifts in either direction (usually < 4/cm, always < 10/cm), and show variable changes in relative band strengths (typically factors of 1-3). There is no evidence of systematic increases or decreases in the absolute strengths of the bands of these molecules when they are incorporated in H2O matrices. In H2O-rich ices, their absorption bands are relatively insensitive to concentration over the range of 10 < H2O/PAH < 200): The absorption bands of these molecules are also insensitive to temperature over the 10 K < T < 125 K range, although the spectra can show dramatic changes as the ices are warmed through the temperature range in which amorphous H2O ice converts to its cubic and hexagonal crystalline forms (T > 125 Kj. Given the small observed band shifts cause by H2O, the current database of spectra from Ar matrix-isolated neutral PAHs and related molecules should be useful for the search for these species in dense clouds on the basis of observed absorption band positions. Furthermore, these data permit determination of column densities to better than a factor of 3 for PAHs in dense clouds. Column density determination of detected aromatics to better than a factor of 3 will, however, require good knowledge about the nature of the matrix in which the PAH is embedded and laboratory studies of relevant samples.

Bernstein, M. P.↗

The Near-Earth Encounter of Asteroid 308635 (2005 YU55): Thermal IR Observations

The near-Earth approach (0.00217 AU, or 0.845 lunar distances) of the C-type asteroid 308635 (2005 YU55) in November 2011 presented a rare opportunity for detailed observations of a low-albedo NEA in this size range. As part of a multi-telescope campaign to measure visible and infrared spectra and photometry, we obtained mid-infrared (approx. 8 to 22 micron) photometry and spectroscopy of 2005 YU55 using Michelle on the Gemini North telescope on UT November 9 and 10,2011. An extensive radar campaign together with optical light-curves established the rotation state of YU55. In addition, the radar imaging resulted in a shape model for the asteroid, detection of numerous boulders on its surface, and a preliminary estimate of its equatorial diameter at 380 +/- 20 m. In a preliminary analysis, applying the radar and lightcurve-derived parameters to a rough-surface thermophysical model fit to the Gemini/Michelle thermal emission photometry results in a thermal inertia range of approximately 500 to 1500 J/sq m/0.5s/K, with the low-thermal-inertia solution corresponding to the small end of the radar size range and vice versa. Updates to these results will be presented and modeling of the thermal contribution to the measured near-infrared spectra from Palomar/Triplespec and IRTF/SpeX will also be discussed.

Lim, Lucy F.↗

Infrared frequencies and intensities for astrophysically important polycyclic aromatic hydrocarbon cations

Polycyclic aromatic hydrocarbons (PAHs) have been implicated as the carriers of the 'unidentified infrared' (UIR) emission bands observed from the interstellar medium. It has long been thought that these molecules, if present, probably exist as cations. In this paper we present infrared spectra of the cations of five moderate-sized PAHs. The PAH cations have been produced by low-energy electron impact and then trapped and stabilized in argon matrices at 12 K. To date, results have been obtained on naphthalene, anthracene, pyrene, perylene, and coronene. A common feature of the infrared spectra of all these cations is the very different intensity pattern of the ions compared to the neutral parents. Visible and (partial) infrared spectra of the coronene cation are also presented. It is shown that the out-of-plane CH bending mode shifts to a position very close to the UIR band at 11.3 microns. The astrophysical impact of these observations is discussed.

Szczepanski, Jan↗

The effect of ionization on the infrared absorption spectra of PAHs: A preliminary report

The emission lines observed in many interstellar IR sources at 3.28, 6.2, 7.7, 8.7, and 11.3 microns are theorized to originate from polycyclic aromatic hydrocarbons (PAHs). These assignments are based on analyses of lab IR spectra of neutral PAHs. However, it is likely that in the interstellar medium that PAHs are ionized, i.e., are positively charged. Besides, as pointed out by Allamandola et al., although the IR emission band spectrum resembles what one might expect from a mixture of PAHs, it does not match in details such as frequency, band profile, or relative intensities predicted from the absorption spectra of any known PAH molecule. One source of more information to test the PAH theory is ab initio molecular orbital theory. It can be used to compute, from first principles, the geometries, vibrational frequencies, and vibrational intensities for model PAH compounds which are difficult to study in the lab. The Gaussian 86 computer program was used to determine the effect of ionization on the infrared absorption spectra of several small PAHs: naphthalene and anthracene. A preliminary report is presented of the results of these calculations.

Defrees, Doug J.↗

Effects of micrometer-scale surface roughness on thermal infrared emittance spectra of silica glass

Surface roughness is known to decrease thermal infrared (TIR) absorption band intensity, but studies of the effect on geologically relevant samples are relatively limited. To determine the effect of surface roughness (with features smaller than ~2/3 of the wavelength) on TIR spectra, we investigated two glass compositions with prepared roughened surfaces: (1) high purity fused silica and (2) soda-lime glass (73 wt% SiO$_2$). We roughened the surfaces of the glasses by sandblasting and polishing with grit paper. The surfaces were characterized with scanning electron microscopy and stylus profilometry. We then analyzed the roughened glasses with TIR emittance spectroscopy. Micrometer-scale roughness causes a decrease in TIR absorption band intensity, relative to a specular surface. No significant changes in band shape or shifts in wavelength were detected. As roughness increases, empirical results show a logarithmic decrease in TIR absorption band intensity. The logarithmic trends of the two glass compositions are different; empirical roughness calibrations do not translate across different compositions. A linear, least-squares spectral deconvolution using two endmembers, specular and blackbody, predicts model spectra of roughened glass surfaces with relatively low error. This is of consequence to orbital TIR measurements of poorly constrained targets, such as the martian surface, because micrometer-scale roughness is adequately modeled by the addition of a blackbody spectrum to the deconvolution endmember matrix.

36 MATERIALS SCIENCE↗

Aluminum oxide in stellar spectra - An infrared electronic transition

Review of recent research on the possibility of detecting the infrared electronic transition of aluminum oxide in the spectra of cool stars. It is shown that this transition may be of considerable significance for the study of Mira-type variables. Specific targets of further laboratory investigation of the transition are pointed out.

Luck, R. E.↗

Infrared reflectance spectra (4-12 microns) of typical lunar samples

A laboratory study of the mid-infrared spectral reflectance properties of typical Apollo lunar rock and soil samples was conducted using a modern interferometric spectrometer. The results show that characteristic spectral features exist in the 4-12 micrometer range that are diagnostic of rock composition and mineralogy, especially for the plagioclase-rich rocks and soils. This is the first phase of a comprehensive infrared reflectance study under way to better understand the use of infrared emission spectroscopy for mapping the surface composition of the moon and other silicate bodies.

Nash, Douglas B.↗

Comparison of visible and near-infrared reflectance spectra of CM2 carbonaceous chondrites and primitive asteroids

Spectra of primitive asteroids (defined as C, P, and D classes and associated subclasses) were compared to the limited number of spectra of CM2 carbonaceous chondrites. An absorption feature located at 0.7 microns attributed to an Fe(+2) - Fe(+3) charge transfer absorption in iron oxides in phyllosilicates is apparent in some of the CM2 carbonaceous chondrite spectra and many of the asteroid spectra. Sawyer found a correlation between the area of the 0.7 micron feature and the mean semimajor axis of the asteroids. Spectra of a larger sample of carbonaceous chondrites, including 7 CM2 chondrites, covering a spectral interval of 0.30-2.5 microns were recently obtained using the Relab instrument at Brown University. These spectra were compared with spectrophotometric asteroid observations in a separate abstract. Those spectra of CM2 chondrites were isolated into the UV, visible and near-infrared spectral regions in order to compare them with high-quality narrowband reflectance spectra.

Vilas, F.↗

Downwelling Far-Infrared Emission Spectra Measured by FIRST at Cerro Toco, Chile and Table Mountain Facility, CA

The Far-Infrared Spectroscopy of the Troposphere (FIRST) instrument is a fourier transform spectrometer developed to measure the far-infrared portion of the Earth's longwave spectrum. Specifically, the purpose is measurement of the important, yet under-investigated 100 to 1000 cm-1 band. Presented here are measurements made by FIRST at two successful deployments in a ground-based configuration to measure downwelling longwave radiation. The initial deployment was to Cerro Toco, Chile. FIRST operated from August to October, 2009 as part of the Radiative Heating in Underexplored Bands Campaign (RHUBC-II) campaign. After recalibration, FIRST was deployed to the Table Mountain Facility from August to October, 2012. Dry days for both campaigns were chosen for analysis ? 09/24/2009 and 10/19/2012. Also available from both deployments are coincident radiosonde temperature and water vapor vertical profiles used as inputs to radiance calculations performed by two platforms, the AER Line-by-Line Radiative Transform Model (using the AER line database), and a research platform, MRTA utilizing HITRAN 2012. Thus, we have three streams of data for the closure studies, and results of the comparisons are presented showing good agreement in the optically thick regions of 200-400 cm-1 and 600-800 cm-1. Differences between measured and coincident calculated spectra between 400 and 600 cm-1 are less than 10 mW/m^2/sr/cm-1. Uncertainties accounted for in this study include uncertainty from multiple detectors, water vapor, temperature, line strength and width as presented in HITRAN 2012, and due to internal heating caused by black bodies. The residuals fall within the root-sum-square envelope of the uncertainties.

J Mast↗

Infrared-ultraviolet spectra of active galactic nuclei

Data from IRAS and IUE were combined with ground based optical and infrared spectrophotometry to derive emission line free spectral energy distributions (SEDs) for 29 active galactic nuclei (AGNs) between 0.1 and 100 microns. The IRAS data were scaled down to account for extended emission. These correction factors, determined by comparing small aperture ground based 10.6 micron data with large aperture IRAS 12 micron fluxes, were usually less than 25%. These corrected SEDs are shown.

Malkan, M. A.↗

Spectral reflectance of hydrophytes

Identification of hydrophytes will improve the delineation and classification of wetlands on remotely sensed imagery. Spectral reflectance measurements of 10 species of hydrophytes were made with an Exotech radiometer during three phenological stages, flowering and early seed, senescent, and early emergent. Reflectance data were analyzed to determine significant (P not greater than 0.5) differences between species in each of four spectral regions during each phenological stage. Eight species had significantly (P not greater than 0.05) different reflectances during the flower and early seed stage. Among the ten species only one could not be spectrally isolated during at least 1 phenological stage. The results indicate that films sensitive to both visible and infrared spectra (e.g., Ektachrome infrared) should enable recognition of different species of hydrophytes.

Best, R. G.↗

Chemical analysis of metal and polymer surfaces on the front and rear LDEF

The University of Alabama in Huntsville experiment AO114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of the Long Duration Exposure Facility (LDEF). Each sample is being subject to a battery of analysis methods. In poster form, details of the x-ray photoelectron spectra, Auger electron spectra, Fourier Transform Infrared and ATR infrared spectra, high resolution profilometry, and scanning electron microscope imagery will be presented from a selection of metal and non-metal surfaces.

Christi, L.↗

Mars Ozone Absorption Line Shapes from Infrared Heterodyne Spectra Applied to GCM-Predicted Ozone Profiles and to MEX/SPICAM Column Retrievals

We present the application of infrared heterodyne line shapes of ozone on Mars to those produced by radiative transfer modeling of ozone profiles predicted by general circulation models (GCM), and to contemporaneous column abundances measured by Mars Express SPICAM. Ozone is an important tracer of photochemistry Mars' atmosphere, serving as an observable with which to test predictions of photochemistry-coupled GCMs. Infrared heterodyne spectroscopy at 9.5 microns with spectral resolving power >1,000,000 is the only technique that can directly measure fully-resolved line shapes of Martian ozone features from the surface of the Earth. Measurements were made with Goddard Space Flight Center's Heterodyne instrument for Planetary Wind And Composition (HIPWAC) at the NASA Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii on February 21-24 2008 UT at Ls=35deg on or near the MEX orbital path. The HIPWAC observations were used to test GCM predictions. For example, a GCM-generated ozone profile for 60degN 112degW was scaled so that a radiative transfer calculation of its absorption line shape matched an observed HIPWAC absorption feature at the same areographic position, local time, and season. The RMS deviation of the model from the data was slightly smaller for the GCM-generated profile than for a line shape produced by a constant-with-height profile, even though the total column abundances were the same, showing potential for testing and constraining GCM ozone-profiles. The resulting ozone column abundance from matching the model to the HIPWAC line shape was 60% higher than that observed by SPICAM at the same areographic position one day earlier and 2.5 hours earlier in local time. This could be due to day-to-day, diurnal, or north polar region variability, or to measurement sensitivity to the ozone column and its distribution, and these possibilities will be explored. This work was supported by NASA's Planetary Astronomy Program.

Fast, Kelly E.↗

The Origin, Composition and History of Comets from Spectroscopic Studies

A wealth of information essential to understanding the composition and physical structure of cometary ice and hence gain deep insight into the comet's origin and history, can be gleaned by carrying out a full range of spectroscopic studies on the returned sample. These studies ought to be among the first performed as they are generally non-destructive and will provide a broad data bank which will be crucial in planning subsequent analysis. Examples of the spectroscopic techniques along with relative sensitivities and transitions probed, are discussed. Different kind of "spectroscopy" is summarized, with emphasis placed on the kind of information each provides. Infrared spectroscopy should be the premier method of analysis as the mid-IR absorption spectrum of a substance contains more global information about the identity and structure of that material than any other property. In fact, the greatest strides in our understanding of the composition of interstellar ices (thought by many to be the primordial material from which comets have formed) have been taken during the past ten years or so because this was when high quality infrared spectra of the interstellar medium (ISM) first became available. The interpretation of the infrared spectra of mixtures, such as expected in comets, is often (not always) ambiguous. Consequently, a full range of other non-destructive, complementary spectroscopic measurements are required to fully characterize the material, to probe for substances for which the IR is not well suited and to lay the groundwork for future analysis. Given the likelihood that the icy component (including some of the organic and mineral phases) of the returned sample will be exceedingly complex, these techniques must be intensely developed over the next decade and then made ready to apply flawlessly to what will certainly be one of the most precious, and most challenging, samples ever analyzed.

Allamandola, L. J.↗

Seasonal Change on Saturn from Cassini/CIRS Observations, 2004-2009

Five years of thermal infrared spectra from the Cassini Composite Infrared Spectrometer (CIRS) are analyzed to determine the response of Saturn's atmosphere to seasonal changes in insolation. Hemispheric mapping sequences at 15.0 cm-1 spectral resolution are used to retrieve the variation in the zonal mean temperatures in the stratosphere (0.5-5.0 mbar) and upper troposphere (75-800 mbar) between October 2004 (shortly after the summer solstice in the southern hemisphere) and July 2009 (shortly before the autumnal equinox). Saturn's northern mid-latitudes show signs of dramatic warming in the stratosphere (by 6-10 K) as they emerge from ring-shadow into springtime conditions, whereas southern mid-latitudes show evidence for cooling (4-6 K). The 40-K asymmetry in stratospheric temperatures between northern and southern hemispheres (at 1 mbar) slowly decreased during the timespan of the observations. Tropospheric temperatures also show temporal variations but with a smaller range, consistent with the increasing radiative time constant of the atmospheric response with increasing pressure. The tropospheric response to the insolation changes shows the largest magnitude at the locations of the broad retrograde jets. Saturn's warm south-polar stratospheric hood has cooled over the course of the mission, but remains present. Stratospheric temperatures are compared to a radiative climate model which accounts for the spatial distribution of the stratospheric coolants. The model successfully predicts the magnitude and morphology of the observed changes at most latitudes. However, the model fails at locations where strong dynamical perturbations dominate the temporal changes in the thermal field, such as the hot polar vortices and the equatorial semi-annual oscillation (Orton, G., and 27 colleagues [2008]. Nature 453, 196-198). Furthermore, observed temperatures in Saturn's ring-shadowed regions are larger than predicted by all radiative-climate models to date due to the incomplete characterization of the dynamical response to the shadow. Finally, far-infrared CIRS spectra are used to demonstrate variability of the para-hydrogen distribution over the 5-year span of the dataset, which may be related to observed changes in Saturn's tropospheric haze in the spring hemisphere.

Fletcher, Leigh N.↗