Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Image-adapted visually weighted quantization matrices for digital image compression

A method for performing image compression that eliminates redundant and invisible image components is presented. The image compression uses a Discrete Cosine Transform (DCT) and each DCT coefficient yielded by the transform is quantized by an entry in a quantization matrix which determines the perceived image quality and the bit rate of the image being compressed. The present invention adapts or customizes the quantization matrix to the image being compressed. The quantization matrix comprises visual masking by luminance and contrast techniques and by an error pooling technique all resulting in a minimum perceptual error for any given bit rate, or minimum bit rate for a given perceptual error.

Watson, Andrew B.↗

AXAF-1 High Resolution Assembly Image Model and Comparison with X-Ray Ground Test Image

The x-ray ground test of the AXAF-I High Resolution Mirror Assembly was completed in 1997 at the X-ray Calibration Facility at Marshall Space Flight Center. Mirror surface measurements by HDOS, alignment results from Kodak, and predicted gravity distortion in the horizontal test configuration are being used to model the x-ray test image. The Marshall Space Flight Center (MSFC) image modeling serves as a cross check with Smithsonian Astrophysical observatory modeling. The MSFC image prediction software has evolved from the MSFC model of the x-ray test of the largest AXAF-I mirror pair in 1991. The MSFC image modeling software development is being assisted by the University of Alabama in Huntsville. The modeling process, modeling software, and image prediction will be discussed. The image prediction will be compared with the x-ray test results.

Zissa, David E.↗

The Pixon Method for Data Compression Image Classification, and Image Reconstruction

As initially proposed, this program had three goals: (1) continue to develop the highly successful Pixon method for image reconstruction and support other scientist in implementing this technique for their applications; (2) develop image compression techniques based on the Pixon method; and (3) develop artificial intelligence algorithms for image classification based on the Pixon approach for simplifying neural networks. Subsequent to proposal review the scope of the program was greatly reduced and it was decided to investigate the ability of the Pixon method to provide superior restorations of images compressed with standard image compression schemes, specifically JPEG-compressed images.

Puetter, Richard↗

Development and Application of Non-Linear Image Enhancement and Multi-Sensor Fusion Techniques for Hazy and Dark Imaging

The purpose of this research was to develop enhancement and multi-sensor fusion algorithms and techniques to make it safer for the pilot to fly in what would normally be considered Instrument Flight Rules (IFR) conditions, where pilot visibility is severely restricted due to fog, haze or other weather phenomenon. We proposed to use the non-linear Multiscale Retinex (MSR) as the basic driver for developing an integrated enhancement and fusion engine. When we started this research, the MSR was being applied primarily to grayscale imagery such as medical images, or to three-band color imagery, such as that produced in consumer photography: it was not, however, being applied to other imagery such as that produced by infrared image sources. However, we felt that it was possible by using the MSR algorithm in conjunction with multiple imaging modalities such as long-wave infrared (LWIR), short-wave infrared (SWIR), and visible spectrum (VIS), we could substantially improve over the then state-of-the-art enhancement algorithms, especially in poor visibility conditions. We proposed the following tasks: 1) Investigate the effects of applying the MSR to LWIR and SWIR images. This consisted of optimizing the algorithm in terms of surround scales, and weights for these spectral bands; 2) Fusing the LWIR and SWIR images with the VIS images using the MSR framework to determine the best possible representation of the desired features; 3) Evaluating different mixes of LWIR, SWIR and VIS bands for maximum fog and haze reduction, and low light level compensation; 4) Modifying the existing algorithms to work with video sequences. Over the course of the 3 year research period, we were able to accomplish these tasks and report on them at various internal presentations at NASA Langley Research Center, and in presentations and publications elsewhere. A description of the work performed under the tasks is provided in Section 2. The complete list of relevant publications during the research periods is provided in Section 5. This research also resulted in the generation of intellectual property.

Rahman, Zia-ur↗

Single-Transducer, Ultrasonic Imaging Method for High-Temperature Structural Materials Eliminates the Effect of Thickness Variation in the Image

NASA Lewis Research Center's Life Prediction Branch, in partnership with Sonix, Inc., and Cleveland State University, recently advanced the development of, refined, and commercialized an advanced nondestructive evaluation (NDE) inspection method entitled the Single Transducer Thickness-Independent Ultrasonic Imaging Method. Selected by R&D Magazine as one of the 100 most technologically significant new products of 1996, the method uses a single transducer to eliminate the superimposing effects of thickness variation in the ultrasonic images of materials. As a result, any variation seen in the image is due solely to microstructural variation. This nondestructive method precisely and accurately characterizes material gradients (pore fraction, density, or chemical) that affect the uniformity of a material's physical performance (mechanical, thermal, or electrical). Advantages of the method over conventional ultrasonic imaging include (1) elimination of machining costs (for precision thickness control) during the quality control stages of material processing and development and (2) elimination of labor costs and subjectivity involved in further image processing and image interpretation. At NASA Lewis, the method has been used primarily for accurate inspections of high temperature structural materials including monolithic ceramics, metal matrix composites, and polymer matrix composites. Data were published this year for platelike samples, and current research is focusing on applying the method to tubular components. The initial publicity regarding the development of the method generated 150 requests for further information from a wide variety of institutions and individuals including the Federal Bureau of Investigation (FBI), Lockheed Martin Corporation, Rockwell International, Hewlett Packard Company, and Procter & Gamble Company. In addition, NASA has been solicited by the 3M Company and Allison Abrasives to use this method to inspect composite materials that are manufactured by these companies.

Roth, Don J.↗

Image Enhancement, Image Quality, and Noise

The Multiscale Retinex With Color Restoration (MSRCR) is a non-linear image enhancement algorithm that provides simultaneous dynamic range compression, color constancy and rendition. The overall impact is to brighten up areas of poor contrast/lightness but not at the expense of saturating areas of good contrast/brightness. The downside is that with the poor signal-to-noise ratio that most image acquisition devices have in dark regions, noise can also be greatly enhanced thus affecting overall image quality. In this paper, we will discuss the impact of the MSRCR on the overall quality of an enhanced image as a function of the strength of shadows in an image, and as a function of the root-mean-square (RMS) signal-to-noise (SNR) ratio of the image.

Rahman, Zia-ur↗

Application of a Near Infrared Imaging System for Thermographic Imaging of the Space Shuttle during Hypersonic Re-Entry

High resolution calibrated near infrared (NIR) imagery was obtained of the Space Shuttle s reentry during STS-119, STS-125, and STS-128 missions. The infrared imagery was collected using a US Navy NP-3D Orion aircraft using a long-range infrared optical package referred to as Cast Glance. The slant ranges between the Space Shuttle and Cast Glance were approximately 26-41 nautical miles at point of closest approach. The Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) project was a NASA Langley led endeavor sponsored by the NASA Engineering Safety Center, the Space Shuttle Program Office and the NASA Aeronautics Research Mission Directorate to demonstrate a quantitative thermal imaging capability. HYTHIRM required several mission tools to acquire the imagery. These tools include pre-mission acquisition simulations of the Shuttle trajectory in relationship to the Cast Glance aircraft flight path, radiance modeling to predict the infrared response of the Shuttle, and post mission analysis tools to process the infrared imagery to quantitative temperature maps. The spatially resolved global thermal measurements made during the Shuttle s hypersonic reentry provides valuable flight data for reducing the uncertainty associated with present day ground-to-flight extrapolation techniques and current state-of-the-art empirical boundary-layer transition or turbulent heating prediction methods. Laminar and turbulent flight data is considered critical for the development of turbulence models supporting NASA s next-generation spacecraft. This paper will provide the motivation and details behind the use of an upgraded NIR imaging system used onboard a Navy Cast Glance aircraft and describe the characterizations and procedures performed to obtain quantitative temperature maps. A brief description and assessment will be provided of the previously used analog NIR camera along with image examples from Shuttle missions STS-121, STS-115, and solar tower test. These thermal observations confirmed the challenge of a long-range acquisition during re-entry. These challenges are due to unknown atmospheric conditions, image saturation, vibration etc. This provides the motivation for the use of a digital NIR sensor. The characterizations performed on the digital NIR sensor included radiometric, spatial, and spectral measurements using blackbody radiation sources and known targets. An assessment of the collected data for three Space Shuttle atmospheric re-entries, STS-119, STS-125, and STS-128, are provided along with a description of various events of interest captured using the digital NIR imaging system such as RCS firings and boundary layer transitions. Lastly the process used to convert the raw image counts to quantitative temperatures is presented along with comparisons to the Space Shuttle's onboard thermocouples.

Zalameda, Joseph N.↗

On-Orbit Line Spread Function Estimation of the SNPP VIIRS Imaging System from Lake Pontchartrain Causeway Bridge Images

The visible infrared imaging radiometer suite (VIIRS) instrument was launched 28 October 2011 onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. The VIIRS instrument is a whiskbroom system with 22 spectral and thermal bands split between 16 moderate resolution bands (M-bands), five imagery resolution bands (I-bands) and a day-night band. In this study we estimate the along-scan line spread function (LSF) of the I-bands and M-bands based on measurements performed on images of the Lake Pontchartrain Causeway Bridge. In doing so we develop a model for the LSF that closely matches the prelaunch laboratory measurements. We utilize VIIRS images co-geolocated with a Landsat TM image to precisely locate the bridge linear feature in the VIIRS images as a linear best fit to a straight line. We then utilize non-linear optimization to compute the best fit equation of the VIIRS image measurements in the vicinity of the bridge to the developed model equation. From the found parameterization of the model equation we derive the full-width at half-maximum (FWHM) as an approximation of the sensor field of view (FOV) for all bands, and compare these on-orbit measured values with prelaunch laboratory results.

Tilton, James C.↗

Denoising with Three Dimensional Fourier Transform for Three Dimensional Images, Including Image Sequences

A method of mitigating noise in source image data representing pixels of a 3-D image. The "3-D image" may be any type of 3-D image, regardless of whether the third dimension is spatial, temporal, or some other parameter. The 3-D image is divided into three-dimensional chunks of pixels. These chunks are apodized and a three-dimensional Fourier transform is performed on each chunk, thereby producing a three-dimensional spectrum of each chunk. The transformed chunks are processed to estimate a noise floor based on spectral values of the pixels within each chunk. A noise threshold is then determined, and the spectrum of each chunk is filtered with a denoising filter based on the noise threshold. The chunks are then inverse transformed, and recombined into a denoised 3-D image.

DeForest, Craig E.↗

Observations from the GOES-R Solar UltraViolet Imager Extended Coronal Imaging Campaign

Solar corona in 17.1nm and 19.5nmwavelengths up to three solar radii from Sun center was observed by the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite (GOES) –16 and GOES-17. The nominally Sun-pointed SUVI was off-pointed to the left and to the right of the Sun center at a regular cadence and a composite Extended Coronal Imaging (ECI) frame was created. The imaging area in the composite is about three times the nominal image area in the East-West direction (about 5*R(sub Sun) versus 1.6*R(sub Sun) for nominal images). The campaign was conducted in February (4 hours), June (72 hours), and August-September of 2018 (5 weeks). Limited solar CME activity during the 5-week campaign was observed in both the SUVI and LASCO C2 imagers. Some of the observations during this campaign include structures up to a few solar radii off the solar limb, and interesting coronal activity –both on and off the solar disk. They are presented here.

Tadikonda, Sivakumar K.↗

Extended Coronal Imaging with GOES-R Solar UltraViolet Imager

Solar corona in 17.1nm and 19.5nm wavelengths up to three solar radii from Sun center was observed by the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite (GOES) – 16 and GOES‐17. The nominally Sun‐pointed SUVI was off‐pointed to the left and to the right of the Sun center at a regular cadence and a composite Extended Coronal Imaging (ECI) frame was created. The imaging area in the composite is about three times the nominal image area in the East‐West direction (about 5*R(sub Sun) versus 1.6*R(sub Sun) for nominal images). The campaign was conducted in February (4 hours), June (72 hours), and August‐September of 2018 (5 weeks). Limited solar CME activity during the 5‐week campaign was observed in both the SUVI and LASCO C2 imagers. Some of the observations during this campaign include structures up to a few solar radii off the solar limb, and interesting coronal activity – both on and off the solar disk. They are presented here.

EUV Solar Corona↗

Estimating the Subsolar Magnetopause Position from Soft X-Ray Images Using a Low-Pass Image Filter

The Lunar Environment heliospheric X-ray Imager (LEXI) and Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) missions will image the Earth’s dayside magnetopause and cusps in soft X-rays after their respective launches in the near future, to specify global magnetic reconnection modes for varying solar wind conditions. To support the success of these scientific missions, it is critical to develop techniques that extract the magnetopause locations from the observed soft X-ray images. In this research, we introduce a new geometric equation that calculates the subsolar magnetopause position ( R s ) from a satellite position, the look direction of the instrument, and the angle at which the X-ray emission is maximized. Two assumptions are used in this method: (1) The look direction where soft X-ray emissions are maximized lies tangent to the magnetopause, and (2) the magnetopause surface near the subsolar point is almost spherical and thus R s is nearly equal to the radius of the magnetopause curvature. We create synthetic soft X-ray images by using the Open Geospace General Circulation Model (OpenGGCM) global magnetohydrodynamic model, the galactic background, the instrument point spread function, and Poisson noise. We then apply the fast Fourier transform and Gaussian low-pass filters to the synthetic images to remove noise and obtain accurate look angles for the soft X-ray peaks. From the filtered images, we calculate R 2 and its accuracy for different LEXI locations, look directions, and solar wind densities by using the OpenGGCM subsolar magnetopause location as ground truth. Our method estimates R s with an accuracy of <0.3 R E when the solar wind density exceeds >10 cm -3 . The accuracy improves for greater solar wind densities and during southward interplanetary magnetic fields. The method captures the magnetopause motion during southward interplanetary magnetic field turnings. Consequently, the technique will enable quantitative analysis of the magnetopause motion and help reveal the dayside reconnection modes for dynamic solar wind conditions. This technique will support the LEXI and SMILE missions in achieving their scientific objectives.

Hyangpyo Kim↗

TEM phase contrast imaging with image plane phase grating

Transmission microscopy imaging systems include a mask and/or other modulator situated to encode image beams, e.g., by deflecting the image beam with respect to the mask and/or sensor. The beam is modulated/masked either before or after transmission through a sample to induce a spatially and/or temporally encoded signal by modifying any of the beam/image components including the phase/coherence, intensity, or position of the beam at the sensor. For example, a mask can be placed/translated through the beam so that several masked beams are received by a sensor during a single sensor integration time. Images associated with multiple mask displacements are then used to reconstruct a video sequence using a compressive sensing method. Another example of masked modulation involves a mechanism for phase-retrieval, whereby the beam is modulated by a set of different masks in the image plane and each masked image is recorded in the diffraction plane.

47 OTHER INSTRUMENTATION↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle

In the paper, new visible wide angle view imaging system of KTM tokamak is described. The system has been designed to observe processes inside of plasma and the processes occurring due to plasma-wall interactions through the long equatorial port. Imaging system is designed based on special image fiber bundle and entrance wide angle lens, which provide image of large section of the vacuum chamber, both poloidal half-section and divertor through the sufficiently long equatorial port. The system also consists of two video cameras: slow and fast with image intensifier. Commercial equipment had been used in design of the system that allowed reducing the cost and time for research and development. The paper also discusses advantages and disadvantages of the system in comparison with conventional endoscopes based on a lens system and considers its promising utilization in future tokamaks and future steady state fusion reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With 99m Tc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99m Tc MAG-3 and a thyroid scan with 123 I) and one plant study (a 99m TcO 4 - xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be a useful tool in image-guided interventions for prostate-cancer diagnosis and treatment.

60 APPLIED LIFE SCIENCES↗

SHOCKED SURFACE STEREO IMAGING WITH FIBER-OPTIC IMAGING PROBES

“A picture tells a thousand words”—this is a concept that captivates everyone, from the casual observer to the experimental physics scientist. To bring this concept to light in support of Stockpile Stewardship subcritical experiments executed at the Nevada National Security Site (NNSS), we have developed a new diagnostic tool to investigate the behavior of materials under high-explosive dynamic shock conditions. For the Leda subcritical experiment executed in August, 2014, a single line-of-sight imaging system was designed and fielded as a stretch diagnostic goal for National Security Technologies, LLC (NSTec). For the Lyra series, beginning with the Orpheus experiment in September 2015, a newly created dynamic stereo surface imaging (DSSI) capability was deployed. The DSSI diagnostic records a high-speed image sequence that allows scientists to peer inside an imploding hydrodynamic test article with stereoscopic imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗