Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Out-of-Pile Test of LVDT-Based Creep Test Rig at PWR Prototypical Conditions

New and improved materials are being considered to support the existing nuclear reactors and future next-generation reactors. The materials can significantly degrade and limit their properties in harsh reactor environments. To accurately understand the material’s degradation, real-time data is required under prototypic-irradiation conditions. Additionally, understanding the creep behavior of materials under harsh environments is essential for an evaluation of safety concerns. To provide these capabilities, the Idaho National Laboratory’s (INL’s) High Temperature Test Laboratory (HTTL) has developed several instrumented test rigs to obtain real-time data from specimens in well-controlled pressurized water reactor (PWR) coolant conditions in the Materials and Test Reactors (MTRs). This technical report focuses on INL’s efforts to evaluate and enhance the former prototype creep test rig that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig is capable of detecting changes in the length of tensile specimen, which is useful for measuring thermal expansion and creep loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Real-Time, In-pile Creep Test Rigs for Characterizing the Structural Materials of Nuclear Components

New and improved materials are being considered for supporting both existing and next-generation nuclear reactors. Reactor materials can significantly degrade with time, thus limiting or altering their properties in harsh reactor environments. To accurately understand such material degradation, real-time data obtained under prototypic irradiation conditions are required. In particular, understanding the creep behavior of materials exposed to irradiation and elevated temperatures is essential for safety concern evaluations. To provide these capabilities, Idaho National Laboratory (INL)’s High Temperature Test Laboratory (HTTL) developed several instrumented test rigs for obtaining real-time data from specimens in well-controlled pressurized-water reactor (PWR) coolant conditions at the Materials Test Reactor. This technical report focuses on INL’s efforts to evaluate and enhance the former creep test rig prototype that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig can detect changes in the length of creep specimens, which is useful for measuring thermal expansion and creep deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rotor-mounted digital instrumentation system for helicopter blade flight research measurements

A rotor mounted flight instrumentation system developed for helicopter rotor blade research is described. The system utilizes high speed digital techniques to acquire research data from miniature pressure transducers on advanced rotor airfoils which are flight tested on an AH-1G helicopter. The system employs microelectronic pulse code modulation (PCM) multiplexer digitizer stations located remotely on the blade and in a hub mounted metal canister. As many as 25 sensors can be remotely digitized by a 2.5 mm thick electronics package mounted on the blade near the tip to reduce blade wiring. The electronics contained in the canister digitizes up to 16 sensors, formats these data with serial PCM data from the remote stations, and transmits the data from the canister which is above the plane of the rotor. Data are transmitted over an RF link to the ground for real time monitoring and to the helicopter fuselage for tape recording. The complete system is powered by batteries located in the canister and requires no slip rings on the rotor shaft.

Knight, V. H., Jr.↗

CF6 Jet Engine Performance Improvement Program: High Pressure Turbine Aerodynamic Performance Improvement

The improved single shank high pressure turbine design was evaluated in component tests consisting of performance, heat transfer and mechanical tests, and in core engine tests. The instrumented core engine test verified the thermal, mechanical, and aeromechanical characteristics of the improved turbine design. An endurance test subjected the improved single shank turbine to 1000 simulated flight cycles, the equivalent of approximately 3000 hours of typical airline service. Initial back-to-back engine tests demonstrated an improvement in cruise sfc of 1.3% and a reduction in exhaust gas temperature of 10 C. An additional improvement of 0.3% in cruise sfc and 6 C in EGT is projected for long service engines.

Fasching, W. A.↗

Influence of rubbing on rotor dynamics, part 2

Rotor dynamic behavior depends considerably on how much the specific physical phenomena accompanying rotor rubbing against the stator is involved. The experimental results of rotor-to-stator rubbing contact are analyzed. The computer code is described for obtaining numerical calculations of rotor-to-stator rubbing system dynamic responses. Computer generated results are provided. The reduced dynamic data from High Pressure Fuel Turbo Pump (HPFTP) hot fire test are given. The results provide some significant conclusions. Information is provided on the electronic instrumentation used in the experimental testing.

Muszynska, Agnes↗

Flux of water vapor in the terrestrial stratosphere and in the Martian atmosphere

A summary of the terrestrial satellite data is presented. The observations indicate that at equatorial latitudes, relatively dry air is introduced at the tropopause and carried to the upper stratosphere. At that altitude, any methane present in the ascending air mass is oxidized photochemically into water vapor. This vapor is eventually transported to high latitudes, where it is carried to the lower stratosphere by the descending leg of the diabatic circulation. The Pressure Modulator Infrared Radiometer instrument aboard the Mars Observer should provide a comparable picture of vapor transport in the martian atmosphere.

Leovy, Conway↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

Vargas, Magda B.↗

A system for testing airdata probes at high angles of attack using a ground vehicle

A system to calibrate airdata probes at angles of attack between 0 and 90 deg was developed and tested at the NASA Ames Dryden Flight Research Facility. This system used a test fixture mounted to the roof of a ground vehicle and included an onboard instrumentation and data acquisition system for measuring pressures and flow angles. The data could be easily transferred to the facility mainframe computer for further analysis. The system was designed to provide convenient and inexpensive airdata probe calibrations for projects which require airdata at high angles of attack, such as the F-18 High Alpha Research Program. This type of probe was tested to 90 deg angle of attack in a wind tunnel and using the ground vehicle system. The results of both tests are in close agreement. An airdata probe with a swiveling pilot-static tube was also calibrated with the ground vehicle system. This paper presents the results of these tests and gives a detailed description of the test system.

Geenen, Robert J.↗

Commercial-Off-The-Shelf Microelectromechanical Systems (MEMS) Flow-Measurement Probes Fabricated And Assembled

As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.

Redding, Chip↗

Retrieval Of Cloud Pressure And Chlorophyll Content Using Raman Scattering In GOME Ultraviolet Spectra

Reliable cloud pressure estimates are needed for accurate retrieval of ozone and other trace gases using satellite-borne backscatter ultraviolet (buv) instruments such as the global ozone monitoring experiment (GOME). Cloud pressure can be derived from buv instruments by utilizing the properties of rotational-Raman scattering (RRS) and absorption by O2-O2. In this paper we estimate cloud pressure from GOME observations in the 355-400 nm spectral range using the concept of a Lambertian-equivalent reflectivity (LER) surface. GOME has full spectral coverage in this range at relatively high spectral resolution with a very high signal-to-noise ratio. This allows for much more accurate estimates of cloud pressure than were possible with its predecessors SBUV and TOMS. We also demonstrate the potential capability to retrieve chlorophyll content with full-spectral buv instruments. We compare our retrieved LER cloud pressure with cloud top pressures derived from the infrared ATSR instrument on the same satellite. The findings confirm results from previous studies that showed retrieved LER cloud pressures from buv observations are systematically higher than IR-derived cloud-top pressure. Simulations using Mie-scattering radiative transfer algorithms that include O2-O2 absorption and RRS show that these differences can be explained by increased photon path length within and below cloud.

Atlas, Robert↗

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗

Liquid neon heat transfer as applied to a 30 tesla cryomagnet

Since superconducting magnets cooled by liquid helium are limited to magnetic fields of about 18 teslas, the design of a 30 tesla cryomagnet necessitates forced convection liquid neon heat transfer in small coolant channels. As these channels are too small to handle the vapor flow if the coolant were to boil, the design philosophy calls for suppressing boiling by subjecting the fluid to high pressures. Forced convection heat transfer data are obtained by using a blowdown technique to force the fluid vertically through a resistance-heated instrumented tube. The data are obtained at inlet temperatures between 28 and 34 K and system pressures between 28 to 29 bars. Data correlation is limited to a very narrow range of test conditions, since the tests were designed to simulate the heat transfer characteristics in the coolant channels of the 30 tesla cryomagnet concerned. The results can therefore be applied directly to the design of the magnet system.-

Papell, S. S.↗

Airflow calibration of a bellmouth inlet for measurement of compressor airflow in turbine-powered propulsion simulators

The development of turbine-powered propulsion simulators for high-speed wind tunnel models requires a bellmouth inlet which can accurately measure compressor-inlet airflow. A bellmouth inlet was instrumented with total pressure probes, static pressure probes, and thermocouples for airflow measurement. The bellmouth flowmeter against a critical venturi flowmeter was calibrated. The calibration was done at four inlet pressures ranging from 58 to 114 kPa. The bellmouth discharge coefficient varied as a function of bellmouth-throat Mach number. Over the range of Reynolds number and Mach number tested the Reynolds number was not a significant influence on the discharge coefficient. The overall accuracy of the bellmouth inlet as a flowmeter was estimated to be + or - 0.5% of the flowmeter reading.

Smith, S. C.↗

A spectral radiance comparison of a noise tube and a HgXe arc lamp between 60 GHz and 600 GHz

The relative spectral radiance of a noise tube, model TN-167, designed for the frequency range 90-140 GHz (3.3 mm to 2.1 mm) was compared to that from a 200-watt high pressure HgXe arc lamp over the wavelength region from 0.5 to about 5 mm. A Michelson Fourier transform spectrometer and a lamellar grating instrument were used in conjunction with liquid helium-cooled bolometers of NEP 10 to the -12th to 10 to the -14th watt/(Hz) exp 1/2 to measure relative spectral radiant power. With this instrumental arrangement, the noise tube exhibited a very sharp low frequency cutoff at about 2.2/cm. The HgXe arc lamp emitted more radiant power than the noise tube in the wavelength region below 3 mm (100 GHz) down to 0.5 mm. Above 3 mm, the noise tube had a stronger output. The noise tube spectral radiance shifted to lower frequencies when the input current was lowered from 125 mA to 50 mA.

Heaney, J. B.↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unsteady pressure measurements on a supercritical airfoil at high Reynolds numbers

Steady and unsteady pressures were measured on a 14 percent supercritical airfoil at transonic Mach numbers at Reynolds numbers from 6,000,000 to 35,000,000. Instrumentation techniques were developed to measure unsteady pressures in a cryogenic tunnel at flight Reynolds numbers. Experimental steady data, corrected for wall effects show very good agreement with calculations from a full potential code with an interacted boundary layer. The steady and unsteady pressures both show a shock position that is dependent on Reynolds number. For a supercritical pressure distribution at a chord Reynolds number of 35,000,000 laminar flow was observed between the leading edge and the shock wave at 45 percent chord.

Hess, R. W.↗