Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Heat pipe systems using new working fluids

The performance of a heat pipe system is greatly improved by the use of a dilute aqueous solution of about 0.0005 and about 0.005 moles per liter of a long chain alcohol as the working fluid. The surface tension-temperature gradient of the long-chain alcohol solutions turns positive as the temperature exceeds a certain value, for example about 40.degree. C. for n-heptanol solutions. Consequently, the Marangoni effect does not impede, but rather aids in bubble departure from the heating surface. Thus, the bubble size at departure is substantially reduced at higher frequencies and, therefore, increases the boiling limit of heat pipes. This feature is useful in microgravity conditions. In addition to microgravity applications, the heat pipe system may be used for commercial, residential and vehicular air conditioning systems, micro heat pipes for electronic devices, refrigeration and heat exchangers, and chemistry and cryogenics.

Chao, David F.↗

ERTS-C (Landsat 3) cryogenic heat pipe experiment definition

A flight experiment designed to demonstrate current cryogenic heat pipe technology was defined and evaluated. The experiment package developed is specifically configured for flight aboard an ERTS type spacecraft. Two types of heat pipes were included as part of the experiment package: a transporter heat pipe and a thermal diode heat pipe. Each was tested in various operating modes. Performance data obtained from the experiment are applicable to the design of cryogenic systems for detector cooling, including applications where periodic high cooler temperatures are experienced as a result of cyclic energy inputs.

Brennan, P. J.↗

Measurements of the performance of an electrohydrodynamic heat pipe

The performance of an electrohydrodynamic heat pipe formed by enclosing three straight axial electrodes with a 1.27 cm O.D. internally threaded stainless steel tube was measured with Freon-11 as working fluid. The condenser and evaporator conductances at low power were comparable to those measured in a conventional capillary driven heat pipe using similar working fluids. The evaporator conductance improved at high power probably due to the onset of nucleate boiling. The maximum heat throughput for this pipe was substantially higher than that of a conventional pipe.

Loehrke, R. I.↗

AN INITIAL LOOK AT THE HEAT PIPE RESILIENCY TO REACTOR OPERATION

Several special purpose reactor designs are aiming to utilize heat pipes due to its inherently passive features allowing safe heat removal to the power conversion systems. There is insufficient data on heat pipe survivability in reactor environments, although heat-pipe failures are predicted to have low failure rates. In this paper, we perform a coupled neutronics and thermo-mechanics analyses for a 45 kWth HALEU fueled, hydride moderated homogenous design to evaluate the transient effects during both startup and a heatpipe-failure scenario. The heatpipe-failure study includes both a single failure case and a failure-propagation (cascading) case. While the model only evaluates a homogenous core, the approach could be applied to more complex models for any heat pipe cooled small reactor.

99 GENERAL AND MISCELLANEOUS↗

Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

Ku, Jentung↗

Evolution of non-condensable gas in ammonia heat pipes

Accumulation of noncondensible gas (NCG) has been observed in ammonia heat pipes. NCG has been found to be detrimental to the performance of heat pipes and can result in complete operational failure. A kinetic and thermodynamic analysis has been performed that evaluates the dissociation of ammonia under various conditions and predicts the amount of NCG present in heat pipes. The analysis indicates that the observed NCG in ammonia heat pipes can be attributed to the dissociation of ammonia into its constituents, hydrogen and nitrogen. It shows time and temperature to be the important parameters, in conjunction with the catalytic characteristic of the container material.

Richter, Robert↗

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗

Long Duration Exposure Facility (LDEF) low-temperature Heat Pipe Experiment Package (HEPP)

The flight test results are discussed obtained with the Heat Pipe Experiment Package (HEPP). The HEPP was designed to demonstrate the performance of an ethane constant conductance heat pipe (CCHP) and an ethane heat pipe diode in microgravity. These heat pipes have a nominal operating temperature range of 140 to 250 K. Also, included in the HEPP is a Phase Change Material (PCM) canister which provides temperature stability through melting and freezing of the n-heptane PCM. A comparison of pre-flight, flight, and post-flight thermal performance is also presented.

Mcintosh, Roy↗

Modular heat pipe radiators for enhanced Shuttle mission capabilities

Current heat pipe radiator technology is reviewed and the results from three state-of-the-art hardware programs are summarized. Heat pipe radiators are shown to be an improvement over all-fluid loop panels for long duration space missions, when micrometeoroid survivability is important. Finally, several heat pipe radiator design concepts are presented which would enhance Shuttle mission capabilities by either extending mission life and/or augmenting heat rejection capability.

Alario, J.↗

Heat Rejection Systems Utilizing Composites and Heat Pipes: Design and Performance Testing

Polymer matrix composites offer the promise of reducing the mass and increasing the performance of future heat rejection systems. With lifetimes for heat rejection systems reaching a decade or more in a micrometeoroid environment, use of multiple heat pipes for fault tolerant design is compelling. The combination of polymer matrix composites and heat pipes is of particular interest for heat rejection systems operating on the lunar surface. A technology development effort is under way to study the performance of two radiator demonstration units manufactured with different polymer matrix composite face sheet resin and bonding adhesives, along with different titanium-water heat pipe designs. Common to the two radiator demonstration units is the use of high thermal conductivity fibers in the face sheets and high thermal conductivity graphite saddles within a light weight aluminum honeycomb core. Testing of the radiator demonstration units included thermal vacuum exposure and thermal vacuum exposure with a simulated heat pipe failure. Steady state performance data were obtained at different operating temperatures to identify heat transfer and thermal resistance characteristics. Heat pipe failure was simulated by removing the input power from an individual heat pipe in order to identify the diminished performance characteristics of the entire panel after a micrometeoroid strike. Freeze-thaw performance was also of interest. This paper presents a summary of the two radiator demonstration units manufactured to support this technology development effort along with the thermal performance characteristics obtained to date. Future work will also be discussed.

Jaworske, Donald A.↗

Machined Titanium Heat-Pipe Wick Structure

Wick structures fabricated by machining of titanium porous material are essential components of lightweight titanium/ water heat pipes of a type now being developed for operation at temperatures up to 530 K in high-radiation environments. In the fabrication of some prior heat pipes, wicks have been made by extruding axial grooves into aluminum unfortunately, titanium cannot be extruded. In the fabrication of some other prior heat pipes, wicks have been made by in-situ sintering of metal powders shaped by the use of forming mandrels that are subsequently removed, but in the specific application that gave rise to the present fabrication method, the required dimensions and shapes of the heat-pipe structures would make it very difficult if not impossible to remove the mandrels due to the length and the small diameter. In the present method, a wick is made from one or more sections that are fabricated separately and assembled outside the tube that constitutes the outer heat pipe wall. The starting wick material is a slab of porous titanium material. This material is machined in its original flat configuration to form axial grooves. In addition, interlocking features are machined at the mating ends of short wick sections that are to be assembled to make a full-length continuous wick structure. Once the sections have been thus assembled, the resulting full-length flat wick structure is rolled into a cylindrical shape and inserted in the heatpipe tube (see figure). This wick-structure fabrication method is not limited to titanium/water heat pipes: It could be extended to other heat pipe materials and working fluids in which the wicks could be made from materials that could be pre-formed into porous slabs.

Rosenfeld, John H.↗

Fabrication and evaluation of aluminum heat pipes

An evaluation is presented for the current heat pipe system on the OAO spacecraft, in order to increase its capability for future missions. A detailed analysis was made of the requirements, and approaches for the design of optimized heat pipes to meet future needs were identified. A composite wick heat pipe was developed, which has significantly higher transport capability than those of conventional wick design.

Source record↗

Investigation of bubbles in arterial heat pipes

The behavior of gas occlusions in arterial heat pipes has been studied experimentally and theoretically. Specifically, the gas-liquid system properties, solubility and diffusivity, have been measured from -50 to 100 C for helium and argon in ammonia, Freon-21 (CHC12F), and methanol. Properties values obtained were then used to experimentally test models for gas venting from a heat pipe artery under isothermal conditions (i.e., no-heat flow), although the models, as developed, are also applicable to heat pipes operated at power, with some minor modifications. Preliminary calculations indicated arterial bubbles in a stagnant pipe require from minutes to days to collapse and vent. It has been found experimentally that a gas bubble entrapped within an artery structure has a very long lifetime in many credible situations. This lifetime has an approximately inverse exponential dependence on temperature, and is generally considerably longer for helium than for argon. The models postulated for venting under static conditions were in general quantitative agreement with experimental data. Factors of primary importance in governing bubble stability are artery diameter, artery wall thickness, noncondensible gas partial pressure, and the property group (the Ostwald solubility coefficient multiplied by the gas/liquid diffusivity).

Saaski, E. W.↗

Variable Conductance Heat Pipe Cooling of Stirling Convertor and General Purpose Heat Source

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Radioisotope Power System↗

Effects of one-sided heat input and removal on axially grooved heat pipe performance

The performance of an axially grooved heat pipe with one-sided heat input and removal was investigated analytically. Under zero-g condition the maximum heat transport of the pipe may decrease as much as 30% depending on the liquid slug behavior in the condenser section. In one-g environment the performance depends mainly on the fluid charge. The maximum heat transport, if over-charged, is almost equal to the value for uniform heating and cooling due to puddling effect. However, for some heater-cooler combinations the temperature drop across the heat pipe becomes very large. Computed results for tilted heat pipes compare favorably with available experimental data.

Kamotani, Y.↗

Design Considerations for Lightweight Space Radiators Based on Fabrication and Test Experience With a Carbon-Carbon Composite Prototype Heat Pipe

This report discusses the design implications for spacecraft radiators made possible by the successful fabrication and proof-of-concept testing of a graphite-fiber-carbon-matrix composite (i.e., carbon-carbon (C-C)) heat pipe. The prototype heat pipe, or space radiator element, consists of a C-C composite shell with integrally woven fins. It has a thin-walled furnace-brazed metallic (Nb-1%Zr) liner with end caps for containment of the potassium working fluid. A short extension of this liner, at increased wall thickness beyond the C-C shell, forms the heat pipe evaporator section which is in thermal contact with the radiator fluid that needs to be cooled. From geometric and thermal transport properties of the C-C composite heat pipe tested, a specific radiator mass of 1.45 kg/sq m can be derived. This is less than one-fourth the specific mass of present day satellite radiators. The report also discusses the advantage of segmented space radiator designs utilizing heat pipe elements, or segments, in their survivability to micrometeoroid damage. This survivability is further raised by the use of condenser sections with attached fins, which also improve the radiation heat transfer rate. Since the problem of heat radiation from a fin does not lend itself to a closed analytical solution, a derivation of the governing differential equation and boundary conditions is given in appendix A, along with solutions for rectangular and parabolic fin profile geometries obtained by use of a finite difference computer code written by the author.

Juhasz, Albert J.↗

Wicking Coating for Heat Pipes

Wicking for inside of heat pipes and heat-storage canisters formed by flame-spraying porous coating over wire mech placed on surface to be treated. Method less expensive than method currently used.

Minnich, W. K.↗

Heat Pipes Cool Power Magnetics

Configurations originally developed for space use are effective in any orientation. Heat pipes integrated into high-power, high-frequency, highvoltage spaceflight magnetics reduce weight and improve reliability by lowering internal tempertures. Two heat pipes integrated in design of power transformer cool unit in any orientation. Electrostatic shield conducts heat from windings to heat pipe evaporator. Technology allows dramatic reductions in size and weight, while significantly improving reliability. In addition, all attitude design of heat pipes allows operation of heat pipes independent of local gravity forces.

Hansen, I.↗