Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Estimators and Fusers for Fiber Delay Estimation Using Environmental Measurements

The properties of deployed network fiber are affected by environmental factors due to their exposure to the elements. Particularly for quantum networks, the resultant delay variations may have significant impacts due to the extreme sensitivity of synchronization, coincidence counting, and other critical operations. In this paper, the delays of 15 km aerial-inground fiber connections are measured, and effects due to temperature, humidity and wind speed are analyzed over multiple periods spanning four seasons of a year. Machine learning methods are first utilized to reveal surprisingly pronounced effects of humidity on the delay, in addition to the expected temperature and its seasonal variations. Estimator and fusion methods are developed to estimate the delay using temperature, humidity and wind speed measurements, by utilizing smooth Gaussian Process Regression (GPR) and nonsmooth Ensemble of Trees (EOT) methods. Measurements from winter and summer periods are temporally fused using twelve different methods, and eight methods provide estimates for the delay throughout the year with median test errors under 1.28%. The results reveal distinct temperature-humidity trends across the seasons, and the ability of estimator and temporal fusion methods to exploit them for estimating the delay. These results constitute a case study of machine learning analytical results, wherein generalization equations explain the performance of various estimator and fuser methods.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗

Parabolic oxidation kinetics of a plutonium alloy at room temperature

Auger electron spectroscopy (AES) was used to characterize the oxide scale formed on an ~0.5 wt. % Ga plutonium metal alloy. Analysis of changes to the characteristic Auger transitions for Pu and O during sputter depth profiles were used in combination with previously measured sputter yields to determine the thickness of the oxide scale and provide insight into its chemistry. From this data, the parabolic kinetics for the Pu-Ga alloy were determined as a function of relative humidity, RH = 14–92%, and oxygen partial pressure, p(O 2 ) = 31–157 Torr, at 25°C. For each relative humidity investigated, the parabolic rate constant was found to be independent of oxygen partial pressure. Furthermore, power-law fits to the relative humidity effect on the rate constant was found to have a power of n = 1.265, indicating the diffusion species which rate-limits the reaction isn’t molecular water, which subsequent dissociates at the oxide-metal interface, or hydroxyl from dissociation at the gas-surface interface.

36 MATERIALS SCIENCE↗

Controlled Demolition and Reconstruction of Imidazolate and Carboxylate Metal–Organic Frameworks by Acid Gas Exposure and Linker Treatment

The metal-linker coordination bond in metal–organic frameworks (MOFs) can be unstable in humid and acid gas environments, leading to loss of crystallinity and porosity. This degradation is not necessarily irreversible; solvent-assisted crystal redemption (“SACRed”) has been shown to recover the physical and chemical properties of ZIF-8 exposed to humid SO 2 . This approach can also be useful in creating mixed-linker materials that might be challenging to produce via de novo synthesis. Here, we expand more generally the concept of controlled degradation of a MOF with acid gas, followed by treatment with a fresh linker solution, to the use of different template MOFs (ZIFs, UiO-66, and UiO-67) and acid gases (SO 2 and NO 2 in dry and humid conditions). Significant losses in porosity and crystallinity along with structural changes (acid gas-linker complexes and linker functionalizations) are observed in the acid gas-exposed MOF templates, and SACRed is shown to reconstruct these partially demolished MOFs with a high degree of structural recovery. Detailed structural and spectroscopic characterizations of the controlled degradation and subsequent recovery are presented and analyzed. Furthermore, these findings indicate the generality of controlled degradation and reconstruction as a means for linker replacement in a wider variety of MOFs and also create the potential for linker substitutions (with non-native linkers) to obtain new hybrid MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COVID-19: Effects of Environmental Conditions on the Propagation of Respiratory Droplets

As coronavirus disease 2019 (COVID-19) continues to spread, a detailed understanding on the transmission mechanisms is of paramount importance. The disease transmits mainly through respiratory droplets and aerosol. Although models for the evaporation and trajectory of respiratory droplets have been developed, how the environment impacts the transmission of COVID-19 is still unclear. In this study, we investigate the propagation of respiratory droplets and aerosol particles generated by speech under a wide range of temperatures (0–40 °C) and relative humidity (0–92%) conditions. We show that droplets can travel three times farther in low-temperature and high-humidity environment, whereas the number of aerosol particles increases in high-temperature and low-humidity environments. The results also underscore the importance of proper ventilation, as droplets and aerosol spread significantly farther in airstreams. This study contributes to the understanding of the environmental impact on COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗

Moisture-Induced Structural Degradation in Methylammonium Lead Iodide Perovskite Thin Films

Methylammonium lead iodide (CH 3 NH 3 PbI 3 , MAPbI 3 ) belongs to the group of organic–inorganic halide perovskites (OIHPs) that exhibit exceptional electrical and optical behavior suitable for photovoltaic applications. However, improving its structural and chemical stability and robustness remains a challenge for OIHPs to be considered a feasible active material in optoelectronic devices. This is due to the fact that this material is very susceptible to degrade under various intrinsic and extrinsic factors. Therefore, it is crucial to understand the mechanisms through which MAPbI 3 undergoes chemical degradation under operating conditions such as a relatively humid environment. We present the structural characteristics of MAPbI 3 under working conditions that suggest the routes of phase segregation as a result of exposing to highly moist media. We use dark pulse discharge behavior and current–voltage (I–V) variations of MAPbI 3 under different moisture levels to investigate the nature of structural degradation in OIHPs. Here we show that while relatively lower levels of humidity (~60% RH) have a limited impact on the structural stability of MAPbI 3 , exposure to higher levels of moisture (~100% RH) results in the formation of PbI 2 and aqueous CH 3 NH 3 I, which fundamentally change the charge transport characteristics in MAPbI 3 . Our findings explain the ongoing debate on the presence of a threshold for the humidity that triggers irreversible structural transformation and leads to full degradation of MAPbI 3 .

36 MATERIALS SCIENCE↗

Nearby Sites Show Similar Upwind Sources and Differing Semivolatile Concentrations in Coastal Aerosol Particles

The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized aerosol composition using measurements at two sites within 3 km (Scripps Pier and Mt. Soledad) from 15 February 2023 to 14 February 2024. Comparing the two sites shows the strong influence of upwind sources that results in similar monthly compositions at both sites. The seasonal changes in chemical mass concentrations were largely driven by the upwind source regions, with coastal northwesterly back-trajectories occurring 63−65% of the year and bringing submicrometer mass concentrations that were lower than the EPCAPE average for all trajectories at each site. In contrast, refractory black carbon (rBC) and nonrefractory (NR)-organics and nitrate mass concentrations exceeded EPCAPE average concentrations for back-trajectories from urban areas such as Los Angeles-Long Beach. For hourly measurements, NR-organics and non-sea-salt (NSS)-sulfate mass concentrations at Mt. Soledad were correlated strongly (r = 0.73−0.82) to those measured at Scripps Pier, but NR-nitrate was correlated only moderately (r = 0.63). The explanation for the lower correlation of NR-nitrate is both emissions between the sites and semivolatility, with semivolatility accounting for site-to-site changes in daily averages of +0.01 μg m −3 per percentage site-to-site difference in relative humidity and −0.07 μg m −3 per degree Celsius site-to-site difference in temperature. On average, comparing Scripps Pier to Mt. Soledad, NR-nitrate was higher by 29% because of relative humidity and lower by −26% because of temperature. NR-nitrate and rBC mass concentrations at Scripps Pier for nighttime were 13−15% higher than those for daytime because land breezes brought higher inland concentrations. Concentrations of rBC were 52% higher at Mt. Soledad than those measured at Scripps Pier, accompanied by increases in tracers for brake wear because of traffic on the steep roads within 10 m of that site. The implications are that these nearby sites had comparable monthly concentrations of measured components due to their similar backtrajectories, but hourly and daily concentration differences supported quantification of the meteorological effects from relative humidity and temperature on semivolatile NR-nitrate as well as minor differences from land−sea breezes and local emissions.

Aerosols↗

Changes in Convective Available Potential Energy and Convective Inhibition under Global Warming

Atmospheric convective available potential energy (CAPE) is expected to increase under greenhouse gas–induced global warming, but a recent regional study also suggests enhanced convective inhibition (CIN) over land although its cause is not well understood. In this study, a global climate model is first evaluated by comparing its CAPE and CIN with reanalysis data, and then their future changes and the underlying causes are examined. The climate model reasonably captures the present-day CAPE and CIN patterns seen in the reanalysis, and projects increased CAPE almost everywhere and stronger CIN over most land under global warming. Over land, the cases or times with medium to strong CAPE or CIN would increase while cases with weak CAPE or CIN would decrease, leading to an overall strengthening in their mean values. These projected changes are confirmed by convection-permitting 4-km model simulations over the United States. The CAPE increase results mainly from increased low-level specific humidity, which leads to more latent heating and buoyancy for a lifted parcel above the level of free convection (LFC) and also a higher level of neutral buoyancy. The enhanced CIN over most land results mainly from reduced low-level relative humidity (RH), which leads to a higher lifting condensation level and a higher LFC and thus more negative buoyancy. Over tropical oceans, the near-surface RH increases slightly, leading to slight weakening of CIN. Over the subtropical eastern Pacific and Atlantic Ocean, the impact of reduced low-level atmospheric lapse rates overshadows the effect of increased specific humidity, leading to decreased CAPE.

54 ENVIRONMENTAL SCIENCES↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Empirical prediction of saline water atomization pressure loss and spray phase change using local flow pressure analysis

A pressure analysis technique was developed to obtain spray spatial evaporation profile in a thermal desalination process. The technique can replace temperature-based evaporation measurement methods that are challenged by liquid-phase interference. It also provides an alternative to optical methods with high cost and complexity. Fundamental analysis was developed to determine local humidity ratios from changes in local static and dynamic pressures. The analysis was applied to data obtained from an external mixing air-assist atomizer. An empirical model was developed for the pressure loss in atomization process and was used in the analysis of humidity ratio. The results were used to develop empirical correlations for local humidity ratio in spray mediums using inlet conditions. Utilizing inlet conditions to predict evaporation profiles is an important contribution as it eliminates the need to take local spray measurements. Obtaining local data is often difficult and expensive; Our method and correlation circumvent the need for that. Finally, the correlations presented in this paper apply to saline water sprays with total dissolved salt of 0-10 wt%. The salinity-specific correlations are accurate to within ±10% of experimental data. The individual models were aggregated into a unified correlation for salinities within 0-10 wt%. The unified correlation is accurate to within ±18% of experimental data.

42 ENGINEERING↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Hygroscopic growth of UO 2 F 2 nanoparticles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 nanoparticle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Although the largest size of UO 2 F 2 nanoparticles was 80 nm, monodisperse aerosol with a mobility diameter of up to approximately 500 nm can be investigated using the HTDMA. Anhydrous UO 2 F 2 nanoparticles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter from 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. Here, these results demonstrate the hygroscopic properties of UO 2 F 2 nanoparticles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 nanoparticles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 nanoparticles in the atmosphere.

Hygroscopicity↗

Supported ionic liquid membranes (SILMs) with exceptional selectivity and permeability for dilute CO 2 separations

Supported ionic liquid membranes (SILMs), containing phosphonium ionic liquids with aprotic N-heterocyclic anions (AHA ILs) in an inert inorganic support, were tested under both dry and humidified (40 % RH) mixed-gas conditions down to 420 ppm CO 2 in N 2 at 35 °C. In the dry case, the best performing IL, triethyl(octyl)phosphonium 4-bromopyrazolide ([P 2228 ][4-BrPyra]) exhibited mixed-gas CO 2 permeabilities and CO 2 /N 2 permeability selectivities as high as 26,800 barrer and 7,000, respectively. In the presence of humidity, the CO 2 permeability and CO 2 /N 2 selectivity increased to 49,100 barrer and 13,200, respectively, and these are the highest reported combination in the literature. Humidity amplifies CO 2 permeabilities and CO 2 /N 2 permeability selectivities through increases in CO 2 capacity due to bicarbonate formation and through faster mobility of the mobile carrier from decreased viscosity. Furthermore, N 2 permeability stayed roughly invariant in the presence of humidity, likely from competing effects of viscosity reduction and lower N 2 solubility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗