Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Lunar and Planetary Science XXXV: Terrestrial Planets: Building Blocks and Differentiation

The session "Terrestrial Planets: Building Blocks and Differentiation: included the following topics:Magnesium Isotopes in the Earth, Moon, Mars, and Pallasite Parent Body: High-Precision Analysis of Olivine by Laser-Ablation Multi-Collector ICPMS; Meteoritic Constraints on Collision Rates in the Primordial Asteroid Belt and Its Origin; New Constraints on the Origin of the Highly Siderophile Elements in the Earth's Upper Mantle; Further Lu-Hf and Sm-Nd Isotopic Data on Planetary Materials and Consequences for Planetary Differentiation; A Deep Lunar Magma Ocean Based on Neodymium, Strontium and Hafnium Isotope Mass Balance Partial Resetting on Hf-W System by Giant Impacts; On the Problem of Metal-Silicate Equilibration During Planet Formation: Significance for Hf-W Chronometry ; Solid Metal-Liquid Metal Partitioning of Pt, Re, and Os: The Effect of Carbon; Siderophile Element Abundances in Fe-S-Ni-O Melts Segregated from Partially Molten Ordinary Chondrite Under Dynamic Conditions; Activity Coefficients of Silicon in Iron-Nickel Alloys: Experimental Determination and Relevance for Planetary Differentiation; Reinvestigation of the Ni and Co Metal-Silicate Partitioning; Metal/Silicate Paritioning of P, Ga, and W at High Pressures and Temperatures: Dependence on Silicate Melt Composition; and Closure of the Fe-S-Si Liquid Miscibility Gap at High Pressure and Its Implications for Planetary Core Formation.

Source record↗

Arterial baroreflex control of sympathetic nerve activity during acute hypotension: effect of fitness

We examined arterial baroreflex control of muscle sympathetic nerve activity (MSNA) during abrupt decreases in mean arterial pressure (MAP) and evaluated whether endurance training alters baroreflex function. Acute hypotension was induced nonpharmacologically in 14 healthy subjects, of which 7 were of high fitness (HF) and 7 were of average fitness (AF), by releasing a unilateral arterial thigh cuff after 9 min of resting ischemia under two conditions: control, which used aortic and carotid baroreflex (ABR and CBR, respectively) deactivation; and suction, which used ABR deactivation alone. The application of neck suction to counteract changes in carotid sinus transmural pressure during cuff release significantly attenuated the MSNA response (which increased 134 +/- 32 U/14 s) compared with control (which increased 195 +/- 43 U/14 s) and caused a greater decrease in MAP (19 +/- 2 vs. 15 +/- 2 mmHg; P < 0.05). Furthermore, during both trials, the HF subjects exhibited a greater decrease in MAP compared with AF subjects despite an augmented baroreflex control of MSNA. These data indicate that the CBR contributes importantly to the MSNA response during acute systemic hypotension. Additionally, we suggest that an impaired control of vascular reactivity hinders blood pressure regulation in HF subjects.

Non-NASA Center↗

Modern Radar Techniques for Geophysical Applications: Two Examples

The last decade of the evolution of radar was heavily influenced by the rapid increase in the information processing capabilities. Advances in solid state radio HF devices, digital technology, computing architectures and software offered the designers to develop very efficient radars. In designing modern radars the emphasis goes towards the simplification of the system hardware, reduction of overall power, which is compensated by coding and real time signal processing techniques. Radars are commonly employed in geophysical radio soundings like probing the ionosphere; stratosphere-mesosphere measurement, weather forecast, GPR and radio-glaciology etc. In the laboratorio di Geofisica Ambientale of the Istituto Nazionale di Geofisica e Vulcanologia (INGV), Rome, Italy, we developed two pulse compression radars. The first is a HF radar called AIS-INGV; Advanced Ionospheric Sounder designed both for the purpose of research and for routine service of the HF radio wave propagation forecast. The second is a VHF radar called GLACIORADAR, which will be substituting the high power envelope radar used by the Italian Glaciological group. This will be employed in studying the sub glacial structures of Antarctica, giving information about layering, the bed rock and sub glacial lakes if present. These are low power radars, which heavily rely on advanced hardware and powerful real time signal processing. Additional information is included in the original extended abstract.

Arokiasamy, B. J.↗

Development and Performance of the Oxygen Sensor in the CSA-CP Aboard the International Space Station

A combustion products analyzer (CPA) was built for use on Shuttle in response to several thermodegradation incidents that had occurred during early flights. The CPA contained sensors that measured carbon monoxide, hydrogen chloride, hydrogen cyanide, and hydrogen fluoride. These marker compounds, monitored by the CPA, were selected based upon the likely products to be released in a spacecraft fire. When the Toxicology Laboratory group at Johnson Space Center (JSC) began to assess the air quality monitoring needs for the International Space Station (ISS), the CPA was the starting point for design of an instrument to monitor the atmosphere following a thermodegradation event. The final product was significantly different from the CPA and was named the compound specific analyzer-combustion products (CSA-CP). The major change from the CPA that will be the focus of this paper was the replacement of an unreliable hydrogen fluoride (HF) sensor with an oxygen sensor. A reliable HF sensor was not commercially available, but as the toxicology group reviewed the overall monitoring strategy for ISS, it appeared that a portable oxygen sensor to backup the major constituent analyzer was needed. Therefore, an oxygen sensor replaced the HF sensor in the new instrument. This paper will describe the development, deployment, and performance of the CSA-CP oxygen sensor on both Shuttle and ISS. Also, data for CSA-CP oxygen sensor accuracy at nominal and reduced pressures will be presented.

Limero, Thomas↗

Month-to-Month and Year-to-Year Reproducibility of High Frequency QRS ECG signals

High frequency (HF) electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. We therefore prospectively investigated the reproducibility of the root mean squared (RMS) voltage, kurtosis, and the presence versus absence of reduced amplitude zones (RAzs) in signal averaged 12-lead HF QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of RMS voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of RMS voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. RAzs were also reproducible at a rate of up to 87% and 8 1 %, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead HF QRS electrocardiograms are sufficiently reproducible for clinical use.

Batdorf, Niles↗

High-frequency Electrocardiogram Analysis in the Ability to Predict Reversible Perfusion Defects during Adenosine Myocardial Perfusion Imaging

Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.

Tragardh, Elin↗

Effects of Stoichiometry on Transformation Temperatures and Actuator-Type Performance of NiTiPd and NiTiPdX High-Temperature Shape Memory Alloys

High-temperature shape memory NiTiPd and NiTiPdX (X=Au, Pt, Hf) alloys were produced with titanium equivalent (Ti+Hf) compositions of 50.5, 50.0, 49.5, and 49.0 at.%. Thermo-mechanical testing in compression was used to evaluate the transformation temperatures, transformation strain, work output, and permanent deformation behavior of each alloy to study the effects of quaternary alloying and stoichiometry on high-temperature shape memory alloy behavior. Microstructural evaluation showed the presence of second phases for all alloy compositions. No load transformation temperatures in the stoichiometric alloys were relatively unchanged by Au and Pt substitutions, while the substitution of Hf for Ti causes a drop in transformation temperatures. The NiTiPd, NiTiPdAu and NiTiPdHf alloys exhibited transformation temperatures that were highest in the Ti-rich compositions, slightly lower at stoichiometry, and significantly reduced when the Ti equivalent composition was less than 50 at.%. For the NiTiPdPt alloy, transformation temperatures were highest for the Ti-rich compositions, lowest at stoichiometry, and slightly higher in the Ni-rich composition. When thermally cycled under constant stresses of up to 300 MPa, all of the alloys had transformation strains, and therefore work outputs, which increased with increasing stress. In each series of alloys, the transformation strain and thus work output was highest for stoichiometric or Ti-rich compositions while permanent strain associated with the constant-load thermal cycling was lowest for alloys with Ni-equivalent-rich compositions. Based on these results, basic rules for optimizing the composition of NiTiPd alloys for actuator performance will be discussed.

Bigelow, Glen S.↗

Duration of a Magma Ocean and Subsequent Mantle Overturn in Mars: Evidence from Nakhlites

It is now generally accepted that the heat produced by accretion, short-lived radioactive elements such as Al-26, and gravitational energy from core formation was sufficient to at least partially melt the silicate portions of terrestrial planets resulting in a global-scale magma ocean. More particularly, in Mars, the geochemical signatures displayed by shergottites, are likely inherited from the crystallization of this magma ocean. Using the short-lived chronometer Sm-146 - Nd-142 (t(sup 1/2) = 103 Myr), the duration of the Martian magma ocean (MMO) has been evaluated to being less than 40 Myr, while recent and more precise ND-142/ND-144 data were used to evaluate the longevity of the MMO to approximately 100 Myr after the solar system formation. In addition, it has been proposed that the end of the crystallization of the MMO may have triggered a mantle overturn, as a result of a density gradient in the cumulate layers crystallized at different levels. Dating the mantle overturn could hence provide additional constraint on the duration of the MMO. Among SNC meteorites, nakhlites are characterized by high epsilon W-182 of approximately +3 and an epsilon Nd-142 similar to depleted shergottites of +0.6-0.9. It has hence been proposed that the source of nakhlites was established very early in Mars history (approximately 8-10 Myr). However, the times recorded in HF-182-W-182 isotope system, i.e. when 182Hf became effectively extinct (approximately 50 Myr after solar system formation) are less than closure times recorded in the Sm-146-Nd-142 isotope system (with a full coverage of approximately 500 Myr after solar system formation). This could result in decoupling between the present-day measured epsilon W-182 and epsilon Nd-142 as the SM-146 may have recorded later differentiation events in epsilon ND-142 not observed in epsilon W-182 values. With these potential complexities in short-lived chronological data for SNC's in mind, new Hf-176/Hf-177, Nd-143/Nd-144 and Nd-142/Nd-144 were obtained for three nakhlites (Nakhla, MIL03346 and Yamato000593). These new data are combined with previous epsilon W-182 data, to investigate potential discrepancies between the Hf-182-W-182 and Sm-146-Nd-142 systematics, and the relationship between the source of nakhlites and a crystallizing magma ocean

Debaille, V.↗

Architecting Systems for Human Space Flight

Human-system interactions have been largely overlooked in the traditional systems engineering process. Awareness of human factors (HF) has increased in the past few years, but the involvement of HF specialists is still often too little and too late. In systems involving long-duration human space flight, it is essential that the human component be properly considered in the initial architectural definition phase, as well as throughout the system design process. HF analysis must include not only the strengths and limitations of humans in general, but the variability between individuals and within an individual over time, and the dynamics of group interactions.

Wocken, Gerald↗

Deformed Brueckner-Hartree-Fock calculation for light nuclei

For the first time the Brueckner-Hartree-Fock (BHF) method was applied to nuclei whose intrinsic structure is nonspherical. One aim was to investigate whether the energy dependent reaction matrix calculated from a realistic nucleon-nucleon interaction leads to deformations similar to, or different from, those obtained from energy independent interactions in Hartree-Fock (HF) calculations. Reaction matrix elements were calculated as a function of starting energy for the Hamada-Johnston interaction, using a Pauli operator appropriate to O-16 and a shifted oscillator spectrum for virtual excited states. Binding energies, single-particle energies, radii, and shape deformations of the intrinsic state in unrenormalized as well as renormalized BHF are discussed and compared with previous HF studies. Results are presented for C-12, O-16, and Ne-20.

Braley, R. C.↗

Development of wire drawing processes for refractory metal fibers

Fabrication schedules were developed for producing wire, 0.25 mm to 0.51 mm diameter, from the refractory metal alloys ASTAR-811C, B-88 and W-Hf-C. Tensile properties were evaluated at room temperature and up to 1204 C. Also, the stress rupture properties of the alloys at 1093 C were determined. W-Hf-C and B-88 were found to have the best mechanical properties on a strength to density basis. The fabrication schedules for producing wire from these two alloys were further improved with regards to the wire quality and material yield under the optimization of fabrication schedule.

King, G. W.↗

Analysis of the backscatter spectrum in an ionospheric modification experiment

Predictions of the backscatter spectrum are compared, including effects of ionospheric inhomogeneity with experimental observations of incoherent backscatter from an artificially heated region. Calculations show that the strongest backscatter echo received is not, in fact, from the reflection level, but from a region some distance below (about 0.5 km for an experiment carried out at Arecibo), where the pump wave from a HF transmitter approximately 100 kW) is below the threshold for parametric amplification. By taking the standing wave pattern of the pump into account, asymmetry is explained of the up-shifted and down-shifted plasma lines in the backscatter spectrum, and the several peaks typically observed in the region of the spectrum near the HF transmitter frequency.

Kim, H.↗

Creep behavior of tantalum alloy T-222 at 1365 to 1700 K

High vacuum creep tests on the tantalum T-222 alloy at 0.42 to 0.52 T sub m show that the major portion of the creep curves, up to at least 1 percent strain, can be best described by an increasing creep rate, with strain varying linearly with time. Correlation and extrapolation of the creep curves on the basis of increasing creep rates results in more accurate engineering design data than would use of approximated linear rates. Based on increasing creep rates, the stress for 1 percent strain in 10,000 hours for T-222 is about four times greater than for the Ta-10W alloy. Increasing the grain size results in increased creep strength. Thermal aging prior to testing caused precipitation of the hexagonal close packed (Hf,Ta) sub 2 C, which initially increased creep strength. However, this dimetal carbide was converted during creep testing to face-centered cubic (Hf,Ta)C.

Titran, R. H.↗

Major and trace element abundances in samples from the lunar highlands

Analyses for major elements, REE, Co, Cr, Cs, Ga, Hf, Ni, Rb, Sc, and Zn have been done on samples of Apollo 16 rocks 60025, 60335, 64455, 65015, 67075, and 67629 and on fines 60601, 61221, 61241, 64501, 65701, 67601, and 69941. FeO, Na2O, REE, Co, Cr, Hf, and Sc have been determined in four 4-5 mg chips from 65015 and 20 individual, 2.5-9.5 mg fragments from 65702. It appears that trace element characteristics of small fragments are similar to those of larger rocks. No simple mixing relationship was found among KREEP basalts, VHA basalts, anorthosites, fines, and meteorites. Balances could not be simultaneously achieved for Al2O3 and LIL elements, using analyzed samples as end members for mixing models. Most samples analyzed have negative Eu anomalies, in contrast to the positive anomalies expected for plagioclase cumulates. Most samples may be derived from LIL-rich liquids that flowed into highland valleys.

Haskin, L. A.↗

Process development of two high strength tantalum base alloys (ASTAR-1211C and ASTAR-1511C)

Two tantalum base alloys, Ta-12W-1.0Re-0.7Hf-0.025C(ASTAR-1211C) and Ta-15W-1.0Re-0.7Hf-0.025C(ASTAR-1511C), were cast as 12.5 cm (5 inch) diameter ingots and processed to swaged rod, sheet, forged plate, and tubing. Swaged rod was evaluated with respect to low temperature ductility, elevated temperature tensile properties, and elevated temperature creep behavior. A standard swaging process and final annealing schedule were determined. Elevated temperature tensile properties, low temperature impact properties, low temperature DBTT behavior, and extended elevated temperature creep properties were determined. A process for producing ASTAR-1211C and ASTAR-1511C sheet were developed. The DBTT properties of GTA and EB weld sheet given post-weld anneal and thermal aging treatments were determined using bend and tensile specimens. High and low temperature mechanical properties of forging ASTAR-1211C and ASTAR-1511C plate were determined as well as elevated temperature creep properties. Attempts to produce ASTAR-1211C tubing were partially successful while attempts to make ASTAR-1511C tubing were completely unsuccessful.

Ammon, R. L.↗

Radio detection of thunderstorm activity with an earth-orbiting satellite

A study was made to determine the feasibility of using artificial earth satellites to monitor thunderstorm activity. The nighttime noise-temperature measurements made with the earth-oriented vee antenna of the Radio Astronomy Explorer (RAE 1) satellite in the frequency range 0.2-9.2 MHz were correlated with reported surface thunderstorm activity. Analysis shows that the minimum nighttime HF noise level (in the absence of surface thunderstorms) at an altitude of 5850 km over the United States is fixed by man-made noise. When thunderstorms are active below the satellite, the noise level is increased by about 6-12 dB. The highest level is associated with the most intense storms. It is concluded that thunderstorm regions can be detected by an orbiting satellite using HF radio techniques, but ionospheric effects must be taken into account.

Herman, J. R.↗

Remote sensing of trace constituents from atmospheric infrared emission and absorption spectra

Atmospheric infrared emission and absorption spectra obtained from aircraft and balloon-borne spectrometers are presented. From such spectra, mixing ratio vs altitude profiles are derived for several minor constituents. Recent results for HNO3, CF2Cl2, CFCl3, and HF are presented. In addition, the feasibility of infrared detection of other trace constituents, such as HCl, HF, NH3, NO and SO2, against the rest of the atmospheric background is studied. From this study, made on a line-by-line basis for 'state of the art' airborne spectrometers, potential spectral features for detection of the trace constituents are isolated.

Barker, D. B.↗