Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Vector space methods of photometric analysis. II - Refinement of the MK grid for B stars. III - The two components of ultraviolet reddening

This paper discusses systematic errors which arise from exclusive use of the MK system to determine reddening. It is found that implementation of uvby, beta photometry to refine the qualitative MK grid substantially reduces stellar mismatch error. A working definition of 'identical' ubvy, beta types is investigated and the relationship of uvby to B-V color excesses is determined. A comparison is also made of the hydrogen based uvby, beta types with the MK system based on He and metal lines. A small core correlated effective temperature luminosity error in the MK system for the early B stars is observed along with a breakdown of the MK luminosity criteria for the late B stars. The second part investigates the wavelength dependence of interstellar extinction in the ultraviolet wavelength range observed with the TD-1 satellite. In this study the sets of identical stars employed to find reddening are determined more precisely than in previous studies and consist only of normal, nonsupergiant stars. A multivariate analysis of variance techniques in an unbiased coordinate system is used for determining the wavelength dependence of reddening.

Massa, D.↗

Protection of 100% Inverter-dominated Power Systems with Grid-Forming Inverters and Protection Relays – Gap Analysis and Expert Interviews

This report summarizes a gap analysis resulting from a literature review and expert interviews conducted by subject matter experts from Sandia National Laboratory, Siemens, and the Electric Power Research Institute (EPRI) in Spring 2023. The gap analysis consists of two main parts: The fault-ride through (FRT) behavior of grid-forming (GFM) inverter-based resources (IBR) and the response of state-of-the-art protection relays to the fault currents and voltages from GFM IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Notes on Accuracy of Finite-Volume Discretization Schemes on Irregular Grids

Truncation-error analysis is a reliable tool in predicting convergence rates of discretization errors on regular smooth grids. However, it is often misleading in application to finite-volume discretization schemes on irregular (e.g., unstructured) grids. Convergence of truncation errors severely degrades on general irregular grids; a design-order convergence can be achieved only on grids with a certain degree of geometric regularity. Such degradation of truncation-error convergence does not necessarily imply a lower-order convergence of discretization errors. In these notes, irregular-grid computations demonstrate that the design-order discretization-error convergence can be achieved even when truncation errors exhibit a lower-order convergence or, in some cases, do not converge at all.

Diskin, Boris↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of hematite attrition in a grid jet apparatus

Particulate attrition is of interest for novel carbon-capture processes such as chemical looping combustion because the makeup cost of oxygen carrier is a significant portion of operating cost. As such, models to study and predict attrition of various oxygen carriers in fluidized bed systems are being developed. One of the regions of concern in fluidized bed systems is the high-velocity jet region near gas distributors in a fluid bed. This work studies the attrition of hematite particles using a modified ASTM apparatus to measure the particle size distribution throughout the experiment. Bed weight and gas velocity were varied. Hematite particles above the corresponding threshold value had a severe variation of particle size distributions which decreased with time. Weight fractions of the sieves over time were fit to a linear, time-variant population balance model to offer insight into particle attrition. The first-order rate constant was modified as a decaying exponential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid Services Load Shift Baseline Degradation Analysis Methodology v1

As demand flexibility becomes more common, the mix and frequency of a range of demand flexibility strategies will introduce potential biases into baselines, i.e., the time period immediately prior to a LS event may include other LS or DF events. Baseline degradation assessment provides an approach to quantify how these biases begin to compromise predictive accuracy. Heatmaps, based on each month of the year provides a granular view of a given model's predictive capability. However, for comparing multiple algorithms, separately for weekdays and weekends, aggregating results to seasons provides a simpler means of comparison while still allowing for review of variations by time of day and time of year

Fernandes, Samuel↗

Equitable Energy Transition Planning in Holyoke, Massachusetts: A Technical Analysis for Strategic Gas Decommissioning and Grid Resiliency

Buildings account for 30% of the emissions in Massachusetts and are the largest source of emissions in the United States, along with transportation. Pipeline-delivered methane gas is the dominant heating source in Massachusetts, representing 51% of heating in the state. The current gas network in Massachusetts and across many other US states is aging, a relic of the coal gas era, with thousands of miles of cast iron and unprotected steel pipes that are considered leak prone. Even newer plastic pipes are subject to degradation and in need of replacement, an upgrade that averages $2.8 million per mile of pipeline replacement across investor-owned utilities in Massachusetts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An arbitrary grid CFD algorithm for configuration aerodynamics analysis. Volume 1: Theory and validations

This report documents the user input and output data requirements for the FEMNAS finite element Navier-Stokes code for real-gas simulations of external aerodynamics flowfields. This code was developed for the configuration aerodynamics branch of NASA ARC, under SBIR Phase 2 contract NAS2-124568 by Computational Mechanics Corporation (COMCO). This report is in two volumes. Volume 1 contains the theory for the derived finite element algorithm and describes the test cases used to validate the computer program described in the Volume 2 user guide.

Baker, A. J.↗

An arbitrary grid CFD algorithm for configuration aerodynamics analysis. Volume 2: FEMNAS user guide

This report documents the user input and output data requirements for the FEMNAS finite element Navier-Stokes code for real-gas simulations of external aerodynamics flowfields. This code was developed for the configuration aerodynamics branch of NASA ARC, under SBIR Phase 2 contract NAS2-124568 by Computational Mechanics Corporation (COMCO). This report is in two volumes. Volume 1 contains the theory for the derived finite element algorithm and describes the test cases used to validate the computer program described in the Volume 2 user guide.

Manhardt, Paul D.↗

Analysis of Slope Limiters on Irregular Grids

This paper examines the behavior of flux and slope limiters on non-uniform grids in multiple dimensions. Many slope limiters in standard use do not preserve linear solutions on irregular grids impacting both accuracy and convergence. We rewrite some well-known limiters to highlight their underlying symmetry, and use this form to examine the proper - ties of both traditional and novel limiter formulations on non-uniform meshes. A consistent method of handling stretched meshes is developed which is both linearity preserving for arbitrary mesh stretchings and reduces to common limiters on uniform meshes. In multiple dimensions we analyze the monotonicity region of the gradient vector and show that the multidimensional limiting problem may be cast as the solution of a linear programming problem. For some special cases we present a new directional limiting formulation that preserves linear solutions in multiple dimensions on irregular grids. Computational results using model problems and complex three-dimensional examples are presented, demonstrating accuracy, monotonicity and robustness.

Berger, Marsha↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Interlaminar stress analysis at the skin-stiffener interface of a grid-stiffened composite panel

Results are presented of an analysis of the interlaminar stress components at the skin-wrap, skin-core, and wrap-core interfaces for an advanced-concept stiffened panel using a global/local finite element procedure. The procedure consists of a global model of two-dimensional shell elements that is used to design a grid-stiffened panel with blade-type stiffeners, a local model of three-dimensional solid elements that is used to compute interlaminar stress components, and a scheme devised to assign displacement boundary conditions for the local model that are derived from displacement and rotation data of a few nodes of the global model. The interlaminar stresses for this panel design were found to be well below typical tensile normal and shearing strengths of a graphite-epoxy material.

Wiggenraad, J. F. M.↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Powered By ReEDS™ [Slides]

The National Renewable Energy Laboratory's flagship Regional Energy Deployment System (ReEDS) electric grid planning model is informing the answers to some of the biggest questions surrounding electricity sector research. Powered By ReEDS is the third webinar in the Powered By series. Each webinar highlights an innovative NREL grid planning and analysis tool and its real-world applications. The series is an exciting opportunity to learn directly from NREL's grid experts, so make sure to bring your questions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regimes of Cloud Vertical Structure From Active Observations

We introduce a new type of cloud class, which we call “active cloud regime” (ACR), owing to its provenance from active (lidar and cloud radar) spaceborne cloud observations. ACRs intend to provide a climatological description based on cloud vertical structure (CVS) of the most prevalent monthly CVS mixtures encountered at large spatial scales of ~400 km. ACRs are thus a way to create a gridded dataset of a vertically-resolved cloud mask that can facilitate joint analysis with other gridded datasets. The detailed 2D cloud mask comes from the 2B-CLDCLASS-LIDAR CloudSat dataset fusing CALIPSO (lidar) and CloudSat (cloud radar) cloud detections. We show that the global classification of cloudiness under the ACR framework provides valuable insights on how the world’s dominant cloud systems regulate the two major components of atmospheric energetics, precipitation and radiative cooling. NASA’s GEOS model allows us to demonstrate the feasibility of applying the ACR concept in Earth System Models that have the capability to produce subgrid cloudiness obeying pre-specified vertical overlap rules. Comparison of observed and simulated ACRs provides thus another means to assess the realism of modeled clouds.

cloud vertical structure↗

Microwave Frequency Polarizers

This article describes the fabrication and analysis of microwave frequency polarizing grids. The grids are designed to measure polarization from the cosmic microwave background. It is effective in the range of 500 to 1500 micron wavelength. It is cryogenic compatible and highly robust to high load impacts. Each grid is fabricated using an array of different assembly processes which vary in the types of tension mechanisms to the shape and size of the grids. We provide a comprehensive study on the analysis of the grids' wire heights, diameters, and spacing.

polarization↗