Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Compact pulse transformer for 85 kV, 3.5 μs electron gun anode of compact X-ray cargo scanner

Design of compact and reliable 85kV HV pulse transformer for electron gun anode pulsing is a major concern, when size and space are constraints. This paper describes design procedures and optimization of various parameters like HV insulation, step up ratio, rise time and flat top of Pulse transformer, operating with input from a 10 stage PFN of 50 ohm impedance and charged at 14kV. The transformer should deliver rated output voltage of negative polarity 85kV, 3 to 4μs pulse width, less than 2μs rise time and flat top within 10% across an electron gun load, equivalent to a parallel combination of 10kΩ and 200pF load at a PRF of 250 Hz. Since the Cargo Scanner has to operate on movable carrier, this transformer is designed to operate even in the inclined positions. This transformer has given voltage step up, rise time and flat top of 13.75, 1.5 μs and 4.5% respectively for a 10kΩ and 200pF load at 250Hz PRF and also demonstrated operation in 90{sup °} tilted transformer positions. An effort has been put to achieve maintenance free Pulse transformer by providing effective sealing in the transformer tank to stop breathing action. Also, special flexing walls of transformer tank accommodate for small changes in volume of oil due to temperature variations. (author)

43 PARTICLE ACCELERATORS↗

A Gridded Electron Gun for a Sheet Beam Klystron

This paper describes the development of an electron gun for a sheet beam klystron. Initially intended for accelerator applications, the gun can operate at a higher perveance than one with a cylindrically symmetric beam. Results of 2D and 3D simulations are discussed.

43 PARTICLE ACCELERATORS↗

Dynamics Modelling of Biolistic Gene Guns

The gene transfer process using biolistic gene guns is a highly dynamic process. To achieve good performance, the process needs to be well understood and controlled. Unfortunately, no dynamic model is available in the open literature for analysing and controlling the process. This paper proposes such a model. Relationships of the penetration depth with the helium pressure, the penetration depth with the acceleration distance, and the penetration depth with the micro-carrier radius are presented. Simulations have also been conducted. The results agree well with experimental results in the open literature. The contribution of this paper includes a dynamic model for improving and manipulating performance of the biolistic gene gun.

59 BASIC BIOLOGICAL SCIENCES↗

Design, construction, system integration, and test results of the 1 MW CW RF system for the e-gun cavity in the energy recovery LINAC at Brookhaven National Laboratory

Brookhaven's ERL (Energy Recovery LINAC) requires a 1 MW CW RF system for the superconducting electron gun cavity. The system consists primarily of a klystron tube, transmitter, and High-Voltage Power Supply (HVPS). The 703.75 MHz klystron made by CPl, Inc. provides RF power of 1MW CW with efficiency of 65%. It has a single output window, diode-type electron gun, and collector capable of dissipating the entire beam power. It was fully factory tested including 24-hour heat run at 1.1 MW CWo The solid state HVPS designed by Continental Electronics provides up to 100 kV at low ripple and 2.1 MW CW with over 95% efficiency. With minimal stored energy and a fast shut-down mode no crowbar circuit is needed. Continental 's transmitter includes PLC based user interface and monitoring, RF pre-amplifier, magnet and Vac-Ion pump supplies, cooling water instrumentation, and integral safety interlock system. BNL installed the klystron, HVPS, and transmitter along with other items, such as circulator, water load, and waveguide components. The collaboration of BNL, CPI, and Continental in the design, installation, and testing was essential to the successful operation of the 1MW system.

43 PARTICLE ACCELERATORS↗

Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method, the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a radial radio-frequency electron gun to waste treatment

Electron-beam irradiation has been shown to be a clean, efficient, and effective technique for treating a variety of contaminants in a variety of media. In particular, the ionizing radiation produced by an electron beam can effectively decontaminate wastewater and aid in removing harmful chemicals from industrial flue gas. In this paper, we investigate a novel technique for waste treatment using an electron-beam system in which an (approximately) annular beam converges radially into the treatment volume. We provide preliminary system-level analysis of the design of a radial electron gun, and we discuss hypothetical system constructs in which a radial electron gun is used for treatment of flue gas and wastewater. We derive dose uniformity, throughput rates, and other important treatment parameters for each application. Our results suggest that a lower-energy system with a large-radius cylindrical treatment volume is preferable for flue gas treatment, whereas a higher-energy system with an annular treatment volume is better-suited for wastewater treatment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-Electron Temporal Behavior in the Gun Region of the Tecnai Femto UEM

Here, we conduct systematic simulations of single-electron packet durations in the electron-gun region of a Thermo Fisher/FEI TecnaiFemto UEM. Furthermore, we conducted particle tracing simulations with the General Particle Tracer software package and using field maps generated from the precise Tecnai Femto gun architecture with the Poisson Superfish code.

36 MATERIALS SCIENCE↗

Development of ion source with a washer gun for pulsed neutral beam injection

A new type of economical neutral beam source has been developed by using a single washer gun, pulsed operation, and a simple electrode system. We replaced the conventional hot filaments for arc-discharge-type plasma formation with a single stainless-steel washer gun, eliminating the entire dc power supply for the filaments and the cooling system for the electrodes. Our initial experiments revealed successful beam extraction up to 10 kV and 8.6 A, based on spatial profile measurements of density and temperature in the plasma source. The system also shows the potential to control the beam profile by controlling the plasma parameters in the ion accumulation chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shock initiation behavior of PBXN-9 determined by gas gun experiments

The shock to detonation transition was evaluated in the HMX based explosive PBXN-9 by a series of light-gas gun experiments. PBXN-9 consists of 92 wt% HMX, 2wt% Hycar 4054 & 6 wt% dioctyl adipate with a density of 1.75 g/cm{sup 3} and 0.8% voids. The experiments were designed to understand the specifics of wave evolution and the run distance to detonation as a function of input shock pressure. These experiments were conducted on gas guns in order to vary the input shock pressure accurately. The primary diagnostics were embedded magnetic gauges, which are based on Faraday's law of induction, and Photon Doppler Velocimetry (PDV). The run distance to detonation vs. shock pressure, or 'Pop plot,' was redefined as log(X*) = 2.14-1.82 log(P), which is substantially different than previous data. The Hugoniot was refined as U{sub s} = 2.32 + 2.21 U{sub p}. This data will be useful for the development of predictive models for the safety and performance of PBXN-9 along with providing increased understanding of HMX based explosives in varying formulations.

36 MATERIALS SCIENCE↗

COMPARISON OF THEORY AND MEASUREMENTS OF A TWO-STAGE LIGHT-GAS GUN

A comparison of techniques for obtaining projectile velocity history on a two-stage launcher and discuss gun code accuracy vis-a-vis pressure gauges and the new photonic Doppler velocimetry (PDV) technique is presented. The PDV technique itself is described in a companion paper. The PDV records were differentiated to compute acceleration and, hence, base pressure. Two acceleration episodes are revealed in the data. Base pressure values were compared with measurements from stationary pressure gauges and with predictions of a standard two-stage gun code. The agreement with the pressure gages was satisfactory. Code predictions did not account for the two acceleration stages. However, for the main acceleration episode, the predicted base pressure is in good agreement with the smoothed pressure computed from the PDV record. Both the gauge records and PDV contain short-time pressure spikes which are apparently real. Therefore, use of computed base pressure for projectile design may lead to failures if the projectile is vulnerable to pressure spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Two-colour interferometry and Thomson scattering measurements of a plasma gun

We present experimental measurements of a pulsed plasma gun, using two-colour imaging laser interferometry and spatially resolved Thomson scattering. Interferometry measurements give an electron density n e ≈ 2:7 × 1017 cm -3 at the centre of the plasma plume, at 5 mm from the plasma gun nozzle. The Thomson scattered light is collected from two probing angles allowed us to simultaneously measure the collective and non-collective spectrum of the electron feature from the same spatial locations. The inferred electron densities from the location of the electron plasma waves is in agreement with interferometry. The electron temperatures inferred from the two spectra are not consistent, with T e ≈ 10 eV for non-collective scattering and T e ≈ 30 eV for collective scattering. Here, we discuss various broadening mechanisms such as finite aperture effects, density gradients within the collective volume and collisional broadening to account for some of this discrepancy. We also note the significant red/blue asymmetry of the electron plasma waves in the collective scattering spectra, which could relate to kinetic effects distorting the distribution function of the electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of sub-GV/m accelerating field in a photoemission electron gun powered by nanosecond 𝑋-band radio-frequency pulses

Radio-frequency (rf) photoemission electron guns operating at higher accelerating gradients offer a pathway to produce brighter electron bunches. Brighter beams are expected to revolutionize many areas of science: they could form the backbone of next-generation compact x-ray free-electron lasers or provide coherent ultrafast quantum electron probes. We report on the experimental demonstration of an rf photoemission electron source supporting an accelerating field close to 400 MV/m at the photocathode surface without major rf breakdown or significant dark current over a 3-week experimental run. This unprecedented gradient was achieved by operating the gun in a new regime with short rf pulses, ~9ns X-band (11.7 GHz). The demonstrated paradigm provides a viable path to form relativistic electron beams with unprecedented brightness.

43 PARTICLE ACCELERATORS↗

In Situ observation of dark current emission in a high gradient rf photocathode gun

Undesirable electron field emission (also known as dark current) in high gradient rf photocathode guns deteriorates the quality of the photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 μm) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Scattered strong emission areas with high current have been observed on the cathode. The field enhancement factor β of selected regions on the cathode has been measured. Finally, the postexaminations with scanning electron microscopy and white light interferometry reveal the origins of ~75% strong emission areas overlap with the spots where rf breakdown has occurred.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Brightness Continuous-Wave Electron Beams from Superconducting Radio-Frequency Photoemission Gun

Continuous-wave photoinjectors operating at high accelerating gradients promise to revolutionize many areas of science and applications. They can establish the basis for a new generation of monochromatic x-ray free electron lasers, high-brightness hadron beams, or a new generation of microchip production. In this Letter we report on the record-performing superconducting rf electron gun with CsK 2 Sb photocathode. The gun is generating high charge electron bunches (up to 10 nC / bunch ) and low transverse emittances, while operating for months with a single photocathode. As such, this achievement opens a new era in generating high-power beams with a very high average brightness.

43 PARTICLE ACCELERATORS↗

Data sharing helps avoid “smoking gun” claims of topological milestones

Manipulating the topology of electronic bands can realize new states of matter, with possible implications for information technology. A central question is how to tell whether a topological regime has been achieved. Experiments are often guided by a prediction of a distinct and self-explanatory signal called “the smoking gun.” However, in micrometer- or nanometer-scale specimens, phenomenology can mimic the anticipated behavior without containing the exotic states. We show limited data that are consistent with the presence of four topological phenomena; by considering additional data, we identified the most likely origins of the observed patterns as trivial. Finally, we argue that the reliability of smoking gun–type claims can be greatly enhanced by releasing comprehensive datasets, discussing alternative scenarios, and disclosing the total volume of study.

Frolov, S. M. [Univ. of Pittsburgh, PA (United Sta↗

Improving the Operational Lifetime of the CEBAF Photo-Gun by Anode Biasing

The operating lifetime of GaAs-based photocathodes in DC high voltage electron photo-guns is dominated by the ionization rate of residual beamline gas molecules. In this work, experiments were performed to quantify the improvement in photocathode charge lifetime by biasing the photo-gun anode with a positive voltage, which repels ions generated downstream of the anode. The photo-cathode charge lifetime improved by almost a factor of two when the anode was biased compared to the usual grounded configuration. Simulations were performed using the particle tracking code General Particle Tracer (GPT) with a new custom element. The simulation results showed that both the number and energy of ions play a role in the pattern of QE degradation. The experiment results and conclusions supported by GPT simulations will be presented.

Yoskowitz, J. T.↗