Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

High velocity continuous-flow reactor for the production of solar grade silicon

The feasibility of a high volume, high velocity continuous reduction reactor as an economical means of producing solar grade silicon was tested. Bromosilanes and hydrogen were used as the feedstocks for the reactor along with preheated silicon particles which function both as nucleation and deposition sites. A complete reactor system was designed and fabricated. Initial preheating studies have shown the stability of tetrabromosilane to being heated as well as the ability to preheat hydrogen to the desired temperature range. Several test runs were made and some silicon was obtained from runs carried out at temperatures in excess of 1180 K.

Woerner, L.↗

The 2001 Mars In-Situ-Propellant-Production Precursor (MIP) Flight Demonstration

The successful performance of the five individual demonstrations of MARS IN-SITU-PROPELLANT-PRODUCTION PRECURSOR (MIP) will provide both knowledge of and confidence in the reliability of this technology. At the completion of this flight demonstration, the MIP Team will be able to: a) recommend preferred hardware configurations for the intake and adsorption of carbon dioxide from the Martian atmosphere; b) understand the performance characteristics of zirconia cells to generate propellant-grade oxygen; c) understand long-term performance characteristics of advanced solar cells/arrays operated in the actual Mars environment; d) evaluate the functionality of methods to mitigate the deposition of airborne dust onto solar arrays; and e) recommend preferred hardware designs for innovative thermal management including the radiation of heat to the outside environment.

Kaplan, David I.↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

A neutron tomography study to visualize fluoride salt (FLiNaK) intrusion in nuclear-grade graphite

Manufactured graphite is a preferred material for in-core components of molten salt reactors and fluoride salt-cooled high-temperature reactors, which are in permanent contact with liquid salts. However, owing to the porous nature of nuclear graphite, under certain conditions, molten salts may intrude graphite's pores and affect graphite's properties and functionality. Therefore, a better understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we have demonstrated the use of neutron imaging (computed tomography) in the evaluation of salt penetration and distribution of a wide range of graphite grades with diverse microstructures that have been subjected to FLiNaK (LiF–NaF–KF) intrusion at 750 °C and 5 bar pressure for 12 h. Because of the great neutron attenuation contrast from scattering and adsorption between Li (from FLiNaK) and the graphite matrix, we have obtained direct visualization of FLiNaK salt distribution in the salt-impregnated graphites for the first time. Three-dimensional reconstructed images and cross-sectional concentration profiles demonstrate that salt penetration and density distribution are greatly dependent on the microstructural properties of the graphite grade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laparoscopic Cytoreductive Surgery with Hyperthermic Intraperitoneal Chemotherapy (L-CRS/HIPEC) for Perforated Low-Grade Appendiceal Mucinous Neoplasm (LAMN II)

Introduction: Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS/HIPEC) is an established treatment for pseudomyxoma peritonei resulting from a perforated low-grade appendiceal mucinous neoplasm (LAMN II). In patients with localized disease, a laparoscopic procedure (L-CRS/HIPEC) can be undertaken. Methods: This video demonstrates L-CRS/HIPEC in a 66-year-old male who had previously undergone an appendicectomy for an LAMN II lesion. The preoperative computed tomography (CT) scan suggested disease localized to the right iliac fossa. However, laparoscopic assessment unexpectedly revealed disease in the pelvis and on the right hemidiaphragm and liver surface. Results: A technique for treating the thin film of mucin in the pelvis and on the right hemidiaphragm is demonstrated. The liver is mobilized to facilitate ablation of mucin on the serosal surface of the right lobe. Tips and tricks for starting the omentectomy, dealing with the vascular pedicle, and completing the dissection in the left upper quadrant are shown. The Peritoneal Cancer Index (PCI) score was 5 (3 for the right upper quadrant, 1 for the pelvis, 1 for the small bowel), and the cytoreduction score was CC-1. The operative duration was 8.5 h, and length of hospital stay was 5 days. The patient returned to work after 6 weeks. Discussion: L-CRS/HIPEC can be performed when patients are unexpectedly found to have disease, provided the appendiceal pathology is low grade and the PCI score is low. There are potential benefits to this approach, with a shorter length of hospital stay and faster functional recovery when compared with traditional open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in Detector-Integrated Filter Coatings for the Far Ultraviolet

We report on the continued development of multilayer optical coatings on back-illuminated silicon imaging sensors in order to enhance the functionality of such systems at ultraviolet wavelengths. This includes the development metal-dielectric filter structures to enable solar-blind operation, and graded thickness coatings to tune the spatial response of a detector system to the dispersion of a spectrometer. Such systems can maintain the high internal quantum efficiency afforded by the delta-doping process utilized at NASA JPL, while also providing long-wavelength rejection or a spatially optimized efficiency (or both). We present the characterization of CCD and CMOS image sensors incorporating these processes, and describe the atomic layer deposition coating processes. Such detectors are currently being developed for ground-based high energy physics applications as well as NASA orbital astrophysics instruments operating at wavelengths shorter than 200 nm.

Nikzad, Shouleh↗

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

Low-temperature carbonization of polyacrylonitrile/graphene carbon fibers: A combined ReaxFF molecular dynamics and experimental study

Graphene inclusion in a polymer matrix is a promising route to significantly enhance the mechanical properties of low-grade carbon fibers (CFs). Using ReaxFF molecular dynamics simulation, the atomistic mechanism leading to this enhancement is investigated. We demonstrate that the graphene edges along with the nitrogen and oxygen functional groups play a catalytic role and act as seeds to expedite alignment of the all-carbon rings, which are starting sites for the growth of graphitic structures. To examine the role of this proposed mechanism that enhances the graphitic structure of PAN/graphene CFs, we discuss the experimental results wherein the PAN/graphene CFs carbonized at 1250 C demonstrate 91% (from 632 to 1207 MPa) increase in strength and 101% (from 88 to 177 GPa) enhancement in Young’s modulus compared to PAN-based CFs carbonized at 1500 C. In conclusion, these enhanced mechanical properties of low-grade carbon fibers achieved via graphene inclusion at decreased carbonization temperature provide a means to realize both energy savings and cost reduction.

42 ENGINEERING↗

FINITE ELEMENT MODEL MESH REFINEMENT EFFECTS ON QUALIFICATION OF NUCLEAR GRADE GRAPHITE COMPONENTS

The American Society of Mechanical Engineers (ASME) provides the full and simplified design-by-analysis probabilistic assessments for determining acceptance of nuclear grade graphite core components. The assessments can be characterized by three parts: (1) a component stress distribution, often determined by a finite element (FE) model; (2) a Weibull probability density function (pdf) that characterizes the experimental tensile strength distribution; and (3) the post-processor, which combines the FE model and the Weibull strength distribution in accordance with the full and simplified assessments to determine component acceptance. It is known that the level of mesh refinement in FE models can affect the modeled component’s calculated stress distribution. Depending on the component geometry, the stress distribution may converge with sufficient refinement. It was previously unknown whether the acceptance decision resulting from the full and simplified assessments might change even with sufficient mesh refinement. This study explores that question using experimental strength results for a dog-bone geometry for two graphite grades, IG-110 and PCEA. The simplified assessment has two criteria that must be met, the first limits the combined membrane stress by the allowable stress and the second limits the peak equivalent stress by the allowable stress scaled by the ratio of flexural to tensile strength. In the application of the simplified assessment, convergence of the peak equivalent stress required extreme mesh refinement, however, the acceptance decision was not affected. It is hypothesized that more complex geometries with stress concentrations may present mesh refinement effects on the simplified assessment acceptance decision. Mesh refinement did affect the acceptance decision in the full assessment for the applied pressure loadings in this study. This work suggests component stress distribution convergence is not a sufficient criteria for POF convergence in the full assessment and that mesh refinement should continue until the POF has converged, especially where the resulting POF is bordering the SRC acceptable POF limit.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technology Directions for the 21st Century

New technologies will unleash the huge capacity of fiber-optic cable to meet growing demands for bandwidth. Companies will continue to replace private networks with public network bandwidth-on-demand. Although asynchronous transfer mode (ATM) is the transmission technology favored by many, its penetration will be slower than anticipated. Hybrid networks - e.g., a mix of ATM, frame relay, and fast Ethernet - may predominate, both as interim and long-term solutions, based on factors such as availability, interoperability, and cost. Telecommunications equipment and services prices will decrease further due to increased supply and more competition. Explosive Internet growth will continue, requiring additional backbone transmission capacity and enhanced protocols, but it is not clear who will fund the upgrade. Within ten years, space-based constellations of satellites in Low Earth orbit (LEO) will serve mobile users employing small, low-power terminals. 'Little LEO's' will provide packet transmission services and geo-position determination. 'Big LEO's' will function as global cellular telephone networks, with some planning to offer video and interactive multimedia services. Geosynchronous satellites also are proposed for mobile voice grade links and high-bandwidth services. NASA may benefit from resulting cost reductions in components, space hardware, launch services, and telecommunications services.

Crimi, Giles F.↗

Urban Air Quality Management at Low-Cost Using Micro Air Sensors: A Case Study From Accra, Ghana

Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to non-existent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of the high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was co-located at the Physics Department, University of Ghana with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of this data in identification of local sources and their behavior over time. For this study 15 weeks of data at hourly resolution with approximately 2500 data pairs are generated and analyzed (June 01, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2 ) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μgm -3 between the pre local calibration micro air sensor (i.e. out of box) and the reference-grade instrument. Following currently accepted best practice methods (see e.g., PAS4023) a domain specific (i.e. local) calibration factor was generated using a multi-linear regression model and when this factor is applied to the micro air sensor data, a reduction i.e., improvement in MAE to 1.43 μgm -3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of box, domain calibrated and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyper localized sources associated with urban areas, such as those found in major African cities.

Source apportionment↗

Optically Excited Lasing in a Cavity‐Based, High‐Current‐Density Quantum Dot Electroluminescent Device

Abstract Laser diodes based on solution‐processable materials can benefit numerous technologies including integrated electronics and photonics, telecommunications, and medical diagnostics. An attractive system for implementing these devices is colloidal semiconductor quantum dots (QDs). The progress towards a QD laser diode has been hampered by rapid nonradiative Auger decay of optical‐gain‐active multicarrier states, fast device degradation at high current densities required for laser action, and unfavorable competition between optical gain and optical losses in a multicomponent device stack. Here we resolve some of these challenges and demonstrate optically excited lasing from fully functional high‐current density electroluminescent (EL) devices with an integrated optical resonator. This advance has become possible due to excellent optical gain properties of continuously graded QDs and a refined device architecture, which allows for highly efficient light amplification in a thin, EL‐active QD layer.

36 MATERIALS SCIENCE↗

X-ray photoelectron spectroscopy study of radiofrequency-sputtered refractory compound steel interfaces

Radiofrequency sputtering was used to deposit Mo2C, Mo2B5, and MoSi2 coatings on 440C steel substrates. Both sputter etched and preoxidized substrates were used, and the films were deposited with and without a substrate bias of -300 V. The composition of the coatings was measured as a function of depth by X-ray photoelectron spectroscopy combined with argon ion etching. In the interfacial region there was evidence that bias produced a graded interface in Mo2B5 but not in Mo2C. Oxides of iron and of all film constituents except carbon were presented in all cases but the iron oxide concentration was higher and the layer thicker on the preoxidized substrates. The film and iron oxides were mixed in the MoSi2 and Mo2C films but layered in the Mo2B5 film. The presence of mixed oxides correlates with enhanced film adhesion.

Wheeler, D. R.↗

Support of NASA quality requirements by defense contract administration services regions

Defense Contract Administration Services Regions (DCASR) quality assurance personnel performing under NASA Letters of Delegation must work closely with the assigned technical representative of the NASA centers. It is realized that technical personnel from the NASA Centers cannot make on-site visits as frequently as they would like to. However, DCASR quality assurance personnel would know the assigned NASA technical representative and should contact him when problems arise. The technical representative is the expert on the hardware and should be consulted on any problem area. It is important that the DCASR quality assurance personnel recommend to the delegating NASA Center any new or improved methods of which they may be aware which would assist in achieving the desired quality and reliability in NASA hardware. NASA expects assignment of competent personnel in the Quality Assurance functional area and is not only buying the individual's technical skill, but also his experience. Suggestions by field personnel can many times up-grade the quality or the hardware.

Farrar, Hiram D.↗

Properties and Performance Attributes of Novel Co-extruded Polyolefin Battery Separator Materials: Electrical Properties - Part 2

As NASA prepares for its next era of manned spaceflight missions, advanced energy storage technologies are being developed and evaluated to address and enhance future mission needs and technical requirements. Cell-level components for advanced lithium-ion batteries possessing higher energy, more reliable performance and enhanced, inherent safety characteristics have been under development within the NASA infrastructure. A key component for safe and reliable cell performance is the cell separator, which separates the two energetic electrodes and functions to inhibit the occurrence of an internal short circuit but preserves an ionic current. Recently, a new generation of co-extruded separator films has been developed by ExxonMobil Chemical and introduced into their battery separator product portfolio. Several grades of this new separator material were evaluated with respect to dynamic mechanical properties and safety-related performance attributes, and the results of these evaluations were previously reported in "Part 1: Mechanical Properties" of this publication. This current paper presents safety-related performance results for these novel materials obtained by employing a complementary experimental methodology, which involved the analysis of separator impedance characteristics as a function of temperature. The experimental results from this study are discussed with respect to potential cell safety enhancement for future aerospace as well as for terrestrial energy storage needs, and they are compared with pertinent mechanical properties of these materials, as well as with current state-of-the practice separator materials.

Baldwin, Richard S.↗

Developing Non-Food Grade Brassica Biofuel Feedstock Cultivars with High Yield, Oil Content, and Oil Quality that are Suitable for Low Input Production Dryland Systems (Final Report)

The U.S. uses a substantial amount of fossil fuel as an energy source for a wide range for functions including home heating, agriculture and transportation. In the transportation sector, diesel and jet fuel are consumed at a rapid rate, and alternative liquid energy is being investigated globally and nationally to reduce our dependence on fossil fuel and reduce the impact of our carbon footprint on global climate change. Non-food Brassica crops have the potential of producing high oil yield (over 250 gal acre-1) and have oil quality highly desirable for use as biodiesel or bio jet fuel. Developing oilseed feedstock Brassica cultivars with higher seed and oil yield, with high oil quality and with resistance to pathogens, that can be grown with few chemical inputs will helping break our dependence on fossil fuels and reduce importation of fossil fuels. While some oilseed Brassicas have been grown on a small scale for many years in the Pacific Northwest (PNW), adoption has been limited, and the potential of the crops have not been realized or even fully investigated. This report summarizes the results of a study to develop superior non-food grade winter (B. napus) and spring (B. napus and B. juncea) oilseed cultivars suitable for a range of PNW, and other US environments with high resistance to the biotic and abiotic stresses suitable for high-quality biofuel feedstocks. In conducting this work, genome-wide association selection was used to dissect the genetic architecture of industrial Brassica oilseed germplasm for yield, quality, and resistance to biotic and abiotic stresses. A genome-wide bioinformatics approach was used to identify putative PRR (pattern recognition receptor) - type resistance genes that confer durable resistance to blackleg. A novel transgenic approach was developed to generate resistant non-food oilseed lines using PPR genes Br1033 and Br8486. These genes were inserted into regionally adapted oilseed cultivars.

09 BIOMASS FUELS↗

FTIR and Raman Spectroscopy of Reduced Graphene Oxide Carbon Nanoribbons and Graphene Oxide on Copper (Cu)

In the past couple of decades, carbon nanomaterials produced from graphene and graphite have emerged as one of the more important recently discovered substances. These carbon nanomaterials have been found to exhibit high levels of mechanical strength, thermal resistance, and electrical conductivity, thus having a multitude of applications. Therefore, it is important to identify and analyze their traits in order to maximize their effectiveness. Two spectroscopic techniques employed for such analyses of these materials are Fourier-Transform Infrared (FTIR) and Raman Spectroscopy. The advantages of FTIR and Raman include nondestructive analysis, relatively quick measurements under normal atmospheric conditions, and enhanced sensitivity with high resolution capacity. FTIR Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the functionality groups of a carbon nanomaterial. Raman Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the intensity of the disorder peak, which is greater in intensity if the carbon nanomaterial exhibits greater amounts of functionalities or defects in the graphitic material. There were two sample types which were analyzed with both FTIR and Raman Spectroscopy for the research project: graphene nanoribbons and graphene oxide. The m-grade graphene nanoribbons (GNRs) were produced from m-grade carbon nanotubes (CNTs) via Tour's method. The graphene oxide (GO) was produced from graphene via Tour's method, sonicated and centrifuged, dip-coated onto Copper (Cu) foil, and then photoreduced under a UV light source. FTIR measurements and analyses were conducted using a Jasco FTIR Spectrometer. Raman measurements and analyses were conducted using a Jasco Laser Raman Spectrometer. Tasks and techniques for this project included photoreduction, dip-coating, corrosion testing, FTIR and Raman data collection and analysis, and improvement of data collection for the Raman Spectrometer. GNRs exfoliated and reduced (deoxygenation) at 270 deg. C in air showed a significant decrease in O functionalities according to FTIR. However, Raman revealed that a large increase in graphene planar and edge defects are present as indicated by the disorder band at 1340 cm-1. Further optimization could be performed by thermal exfoliation at lower temperatures assuming a need for fewer structural defects. Graphene oxide coatings showed clear reduction with an increase with photoreduction time. Raman revealed that the reduced graphene oxide films had less disruption in the planar phonon lattice vibrations which indicates that the structure is returning to sp2 hybridization of pristine graphene without adding structural defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Grid-assisted magnetron sputtering deposition of nitrogen graded TiN thin films

Titanium Nitride (TiN) films were obtained using the grid-assisted magnetron sputtering deposition technique on Al substrates in two conditions: under constant and variable nitrogen concentration along the thin solid film thickness. The formation of a film with variable N concentration (herein referred as graded film) was confirmed using energy filtered transmission electron microscopy, X-ray photoelectron spectroscopy and grazing incidence X-ray diffraction. The TiN thin films microstructures were also analysed using scanning and transmission electron microscopies (SEM and TEM). Finally, the viability of synthesizing TiN thin films with variable N concentration is herein proposed as an alternative method for tailoring the properties of such functional coating materials.

36 MATERIALS SCIENCE↗