Experimental Investigation of Vibratory Stresses in a Concentric-Ring Direct-Air-Cycle Nuclear Fuel Element
Preliminary tests made by the General Electric Company indicated that aerodynamic loads might cause large enough distortions in the thin sheet-metal rings of a nuclear fuel element to result in structural failure. The magnitude of the distortions in a test fuel element was determined from strains measured with airflow conditions simulating those expected during engine operation. The measured vibratory strains were low enough to indicate the improbability of failure by fatigue. A conservative estimate of the radial deflection that accompanied peak strains in the outer ring was +0.0006 inch.