Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fourier transform infrared isotopic study of linear MnC{sub 3}: Identification of the {nu}{sub 1}({sigma}) fundamental

Linear MnC{sub 3} has been detected in the products from the dual laser ablation of carbon and manganese rods trapped in solid Ar at {approx}12 K. The {nu}{sub 1}({sigma}) vibrational fundamental, an asymmetric carbon stretching mode, has been identified at 1846.9 cm{sup -1}. Fourier transform infrared measurements of {sup 13}C isotopic shift are in good agreement with the predictions of density functional theory calculations using the mPW1PW91 functional with 6-311+G(3df) basis set. This is the first optical detection of the linear isomer of MnC{sub 3} for which previous photoelectron spectroscopy studies have reported evidence of a cyclic isomer.

36 MATERIALS SCIENCE↗

Fourier Transform Spectroscopy of the A {sup 3}Π– X {sup 3}Σ{sup −} Transition of OH{sup +}

The OH{sup +} ion is of critical importance to the chemistry in the interstellar medium and is a prerequisite for the generation of more complex chemical species. Submillimeter and ultraviolet observations rely on high quality laboratory spectra. Recent measurements of the fundamental vibrational band and previously unanalyzed Fourier transform spectra of the near-ultraviolet A {sup 3}Π− X {sup 3}Σ{sup −} electronic spectrum, acquired at the National Solar Observatory at Kitt Peak in 1989, provide an excellent opportunity to perform a global fit of the available data. These new optical data are approximately four times more precise as compared to the previous values. The fit to the new data provides updated molecular constants, which are necessary to predict the OH{sup +} transition frequencies accurately to support future observations. These new constants are the first published using the modern effective Hamiltonian for a linear molecule. These new molecular constants allow for easy simulation of transition frequencies and spectra using the PGOPHER program. The new constants improve simulations of higher J -value infrared transitions, and represent an improvement of an order of magnitude for some constants pertaining to the optical transitions.

79 ASTRONOMY AND ASTROPHYSICS↗

Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second

We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.

3D shape measurement↗

Characterization of plasmonic hole arrays as transparent electrical contacts for organic photovoltaics using high-brightness Fourier transform methods

Here we present a methodology for probing light-matter interactions in prototype photovoltaic devices consisting of an organic semiconductor active layer with a semitransparent metal electrical contact exhibiting surface plasmon-based enhanced optical transmission. We achieve high-spectral irradiance in a spot size of less than 100 μm using a high-brightness laser-driven light source and appropriate coupling optics. Spatially resolved Fourier transform photocurrent spectroscopy in the visible and near-infrared spectral regions allows us to measure external quantum efficiency with high sensitivity in small-area devices (<1 mm 2 ). Lastly, this allows for rapid fabrication of variable-pitch sub-wavelength hole arrays in metal films for use as transparent electrical contacts, and evaluation of the evanescent and propagating mode coupling to resonances in the active layer.

laser-driven light source↗

X {sup 1}SIGMA{sup +} and a {sup 3}SIGMA{sup +} states of the atom pair K+Cs studied by Fourier-transform spectroscopy

A comprehensive study of the X {sup 1}SIGMA{sup +} and a {sup 3}SIGMA{sup +} electronic states of the K and Cs atom pair is presented. Abundant spectroscopic data include 1937 transitions to the a {sup 3}SIGMA{sup +} state and 13 724 transitions to the X {sup 1}SIGMA{sup +} state for {sup 39}K {sup 133}Cs which were obtained by Fourier-transform spectroscopy. From these data potential energy curves were constructed simultaneously for both states X {sup 1}SIGMA{sup +} and a {sup 3}SIGMA{sup +} which are coupled by the hyperfine interaction. This allows us to accurately model the potential close to K(4s)+Cs(6s) atom-pair asymptote which is required to simulate cold collision processes. Dissociation energies of the X {sup 1}SIGMA{sup +} state as D{sub e}{sup X}=4069.208(40) cm{sup -1} and of the a {sup 3}SIGMA{sup +} state as D{sub e}{sup a}=267.141(20) cm{sup -1} were determined. Scattering lengths are predicted for different KCs isotopologs and Feshbach resonances were calculated for magnetic fields up to 1000 G.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fourier-transform spectroscopy of (4){sup 1}Σ{sup +} → A {sup 1}Σ{sup +} − b {sup 3}Π, A {sup 1}Σ{sup +} − b {sup 3}Π → X{sup 1}Σ{sup +}, and (1){sup 3} Δ{sub 1} → b{sup 3}Π{sub 0±} transitions in KCs and deperturbation treatment of A {sup 1}Σ{sup +} and b {sup 3}Π states

High resolution Fourier-transform spectroscopy data of term values in the spin-orbit (SO) coupled first excited A {sup 1}Σ{sup +} and b{sup 3}Π{sub 0±} states in KCs were obtained from (4){sup 1}Σ{sup +} → A {sup 1}Σ{sup +} − b {sup 3}Π, A {sup 1}Σ{sup +} − b {sup 3}Π → X{sup 1}Σ{sup +}, and (1){sup 3}Δ{sub 1} → b{sup 3}Π{sub 0±} spectra of laser-induced fluorescence (LIF). About 3000 new rovibronic term values of the A {sup 1}Σ{sup +} and b {sup 3}Π{sub Ω} states were obtained with an uncertainty about 0.01 cm{sup −1} and added to the previously obtained 3439 term values in Kruzins et al. [Phys. Rev. A 81, 042509 (2010)] and 30 term values of the b {sup 3}Π{sub 0{sup +}} state levels below the A {sup 1}Σ{sup +} state in Tamanis et al. [Phys. Rev. A 82, 032506 (2010)]. The data field was extended considerably, going down to vibrational level v{sub b} = 0 and up in energy to 13 814 cm{sup −1}, as compared to previously achieved v{sub b} = 14 and E = 13 250 cm{sup −1}. Overall 6431 e-symmetry term values of {sup 39}K{sup 133}Cs were included in 4 × 4 coupled-channel deperturbation analysis. The analytical Morse-Long-Range (MLR) function yielded empirical diabatic potentials for the A {sup 1}Σ{sup +} and b {sup 3}Π{sub 0{sup +}} states while the morphing of the SO ab initio points [J. T. Kim et al., J. Mol. Spectrosc. 256, 57 (2009)] provided the empirical diagonal and off-diagonal SO functions. Overall 98.5% of the fitted term values were reproduced with a rms (root mean square) uncertainty of 0.004 cm{sup −1}. The reliability of the model is proved by a good agreement of predicted and measured term values of the {sup 41}K{sup 133}Cs isotopologue, as well as of measured and calculated intensities of (4){sup 1}Σ{sup +} → A {sup 1}Σ{sup +} − b {sup 3}Π LIF progressions. Direct-potential-fit of low-lying v{sub b} levels of the b {sup 3}Π{sub 0{sup −}} component yielded the MLR potential which represents the 204 f-symmetry experimental term values with a rms uncertainty of 0.002 cm{sup −1}. The Ω-doubling of the b {sup 3}Π{sub 0} sub-state demonstrates a pronounced v{sub b}-dependent increase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fourier-transform spectroscopy and potential construction of the (2){sup 1}Π state in KCs

The paper presents an empirical pointwise potential energy curve (PEC) of the (2){sup 1}Π state of the KCs molecule constructed by applying the Inverted Perturbation Approach routine. The experimental term values in the energy range E(v′, J′) ∈ [15 407; 16 579] cm{sup −1} involved in the fit were based on Fourier-Transform spectroscopy data obtained with 0.01 cm{sup −1} accuracy from the laser-induced (2){sup 1}Π → X{sup 1}Σ{sup +} fluorescence spectra. Buffer gas Ar was used to facilitate the appearance of rotation relaxation lines in the spectra, thus enlarging the (2){sup 1}Π data set and allowing determination of the Λ-splitting constants. The data set included vibrational v′ ∈ [0, 28] and rotational J′ ∈ [7, 274] quantum numbers covering about 67% of the potential well. The present PEC reproduces the overall set of data included in the fit with a standard deviation of 0.5 cm{sup −1}. The obtained value of the Λ-doubling constant q = + 1.8 × 10{sup −6} cm{sup −1} for J′ > 50 and v′ ∈ [0, 6] is in an excellent agreement with q = + 1.84 × 10{sup −6} cm{sup −1} reported in Kim, Lee, and Stolyarov [J. Mol. Spectrosc. 256, 57-67 (2009)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lagrange-mesh calculations and Fourier transform

The Lagrange-mesh method is a very accurate procedure for computing eigenvalues and eigenfunctions of a two-body quantum equation written in the configuration space. Using a Gauss quadrature rule, the method only requires the evaluation of the potential at some mesh points. The eigenfunctions are expanded in terms of regularized Lagrange functions, which vanish at all mesh points except one. Using the peculiarities of the method, it is shown that the Fourier transform of the eigenfunctions, computed in the configuration space, can easily be obtained with good accuracy in the physical domain of the momentum space. Also, observables in this space can easily be computed with good accuracy only using matrix elements and eigenfunctions computed in the configuration space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extended Fourier-transform spectroscopy studies and deperturbation analysis of the spin-orbit coupled A{sup 1}Σ{sup +} and b{sup 3}Π states in RbCs

The article presents a study of the strongly spin-orbit coupled singlet A{sup 1}Σ{sup +} and triplet b{sup 3}Π states of the RbCs molecule, which provide an efficient optical path to transfer ultracold molecules to their rovibrational ground state. Fourier-transform A{sup 1}Σ{sup +} − b{sup 3}Π → X{sup 1}Σ{sup +} and (4){sup 1}Σ{sup +} → A{sup 1}Σ{sup +} − b{sup 3}Π laser-induced fluorescence (LIF) spectra were recorded for the natural mixture of the {sup 85}Rb{sup 133}Cs and {sup 87}Rb{sup 133}Cs isotopologues produced in a heat pipe oven. Overall 8730 rovibronic term values of A{sup 1}Σ{sup +} and b{sup 3}Π states were determined with an uncertainty of 0.01 cm{sup −1} in the energy range [9012, 14087] cm{sup −1}, covering rotational quantum numbers J ∈ [6, 324]. An energy-based deperturbation analysis performed in the framework of the four A{sup 1}Σ{sup +} − b{sup 3}Π{sub Ω=0,1,2} coupled-channels approach reproduces 97% of the experimental term values of both isotopologues with a standard deviation of 0.0036 cm{sup −1}. The reliability of the deperturbed mass-invariant potentials and spin-orbit coupling functions of the interacting A{sup 1}Σ{sup +} and b{sup 3}Π states is additionally proved by a good reproduction of the A − b → X and (4){sup 1}Σ{sup +} → A − b relative intensity distributions. The achieved accuracy of the A − b complex description allowed us to use the latter to assign the observed (5){sup 1}Σ{sup +} → A − b and (3){sup 1}Π → A − b transitions. As is demonstrated, LIF to the A − b complex becomes as informative as to the ground X{sup 1}Σ{sup +} state, which is confirmed by comparing the results of (4){sup 1}Σ{sup +} state analysis based on (4){sup 1}Σ{sup +} → A − b LIF with the data from V. Zuters et al. [Phys. Rev. A 87, 022504 (2013)] based on (4){sup 1}Σ{sup +} → X LIF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-dimensional Fourier transform electronic spectroscopy at a conical intersection

We report measurement and modeling of two-dimensional (2D) electronic spectra of a silicon naphthalocyanine (SiNc) in benzonitrile, a system for which the polarization anisotropy reveals passage through a square-symmetric Jahn-Teller conical intersection in ∼100 fs [D. A. Farrow, W. Qian, E. R. Smith, A. A. Ferro, and D. M. Jonas, J. Chem. Phys. 128, 144510 (2008)]. The measured 2D Fourier transform (FT) spectra indicate loss of electronic coherence on a similar timescale. The 2D spectra arising from femtosecond vibronic dynamics through the conical funnel are modeled by full non-adiabatic treatment of the coupled electronic and vibrational dynamics for a pair of un-damped Jahn-Teller active vibrations responsible for both electronic decoherence and population transfer. Additional damped Jahn-Teller active modes that can cause only decoherence or population transfer are treated with analytical response functions that can be incorporated into the numerical non-adiabatic calculation by exploiting symmetry assignment of degenerate vibronic eigenstates to one of two electronic states. Franck-Condon active totally symmetric modes are incorporated analytically. The calculations reveal that these conical intersection dynamics alone are incapable of destroying the coherence of the initially prepared wavepacket on the experimentally observed timescale and predict an unobserved recurrence in the photon echo slice at ∼200 fs. Agreement with the experimental two-dimensional electronic spectra necessitates a role for totally symmetric vibrational dynamics in causing the echo slice to decay on a ∼100 fs timescale. This extended model also reproduces the ∼100 fs ultrafast electronic anisotropy decay in SiNc when an “asymmetric solvation mode” with a small stabilization energy of ∼2 cm{sup −1} is included. Although calculations show that inhomogeneities in the energy gap between excited states can broaden the anti-diagonal 2D lineshape, the anti-diagonal width is dominated by totally symmetric vibrational motions in SiNc. For this shallow conical intersection, the non-adiabatic dynamics destroy electronic coherence more slowly than they destroy electronic alignment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatio-temporal Fourier Transformer for Long-term Dynamics Prediction (StFT) v1.0

We propose a novel machine learning model spatio-temporal Fourier transformer (StFT) to emulate long-term dynamics of multi-scale and multi-physics systems. Our method StFT overcomes the limitations of rapid error accumulation, particularly in long-term forecasting of systems characterized by complex and coupled dynamics. StFT achieves outstanding accuracy and computational efficiency by effectively capturing multi-scale interactions, and quantify the uncertainties inherent in the predictions. Our model leverages a structured hierarchy of StFT blocks, and explicitly captures dynamics across both macro- and micro- spatial scales. Evaluations conducted on three benchmark datasets (plasma, fluid, and atmospheric dynamics) demonstrate the advantages of our approach over state-of-the-art ML methods.

Bai, Zhe [Lawrence Berkeley National Laboratory (L↗

Double passing the Kitt Peak 1-m Fourier transform spectrometer

Attention is given to a simple technique for performing the conversion of the Kitt Peak 1-m Fourier transform spectrometer's dual input/output optical configuration to a double pass configuration that improves spectral resolution by a factor of 2. The modification is made by placing a flat mirror in the output beam from each cat's eye, retroreflecting the beams back through the cat's eyes to the first beam splitter. A single detector is placed at the second input port, which then becomes the instrument's output.

Jennings, D. E.↗

Applications of asynoptic space - Time Fourier transform methods to scanning satellite measurements

A method proposed by Salby (1982) for computing the zonal space-time Fourier transform of asynoptically acquired satellite data is discussed. The method and its relationship to other techniques are briefly described, and possible problems in applying it to real data are outlined. Examples of results obtained using this technique are given which demonstrate its sensitivity to small-amplitude signals. A number of waves are found which have previously been observed as well as two not heretofore reported. A possible extension of the method which could increase temporal and longitudinal resolution is described.

Lait, Leslie R.↗

Experimental geometry for simultaneous beam characterization and sample imaging allowing for pink beam Fourier transform holography or coherent diffractive imaging

One consequence of the self-amplified stimulated emission process used to generate x rays in free electron lasers (FELs) is the intrinsic shot-to-shot variance in the wavelength and temporal coherence. In order to optimize the results from diffractive imaging experiments at FEL sources, it will be advantageous to acquire a means of collecting coherence and spectral information simultaneously with the diffraction pattern from the sample we wish to study. We present a holographic mask geometry, including a grating structure, which can be used to extract both temporal and spatial coherence information alongside the sample scatter from each individual FEL shot and also allows for the real space reconstruction of the sample using either Fourier transform holography or iterative phase retrieval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Mass Analysis with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: From Inorganic Salt Clusters to Antibody Conjugates and Beyond

Analysis of proteins and complexes under native mass spectrometric (MS) and solution conditions was typically performed using time-of-flight (ToF) analyzers, due to their routine high m/z transmission and detection capabilities. However, over recent years, the ability of Orbitrap-based mass spectrometers to transmit and detect a range of high molecular weight species is well documented. Herein, we describe how a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer (15 T FT-ICR MS) is more than capable of analyzing a wide range of ions in the high m/z scale (>5000), in both positive and negative instrument polarities, ranging from the inorganic cesium iodide salt clusters; a humanized IgG1k monoclonal antibody (mAb; 148.2 kDa); an IgG1-mertansine drug conjugate (148.5 kDa, drug-to-antibody ratio; DAR 2.26); an IgG1-siRNA conjugate (159.1 kDa; ribonucleic acid to antibody ratio; RAR 1); the membrane protein aquaporin-Z (97.2 kDa) liberated from a C8E4 detergent micelle; the empty MSP1D1-nanodisc (142.5 kDa) and the tetradecameric chaperone protein complex GroEL (806.2 kDa; GroEL dimer at 1.6 MDa). We also investigate different regions of the FT-ICR MS that impact ion transmission and desolvation. Finally, we demonstrate how the transmission of these species and resultant spectra are highly consistent with those previously generated on both quadrupole-ToF (Q-ToF) and Orbitrap instrumentation. This article serves as an impactful example of how FT-ICR mass analyzers are competitive to Q-ToFs and Orbitraps for high mass detection at high m/z.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved Fourier-transform infrared emission spectroscopy of Ag in the (1300-3600)-cm{sup -1} region: Transitions involving f and g states and oscillator strengths

We report on a study of the emission spectra of Ag vapor in a vacuum (10{sup -2} Torr) formed in ablation of an Ag metal target by a high-repetition rate (1.0 kHz) pulsed nanosecond ArF laser ({lambda}=193 nm, output energy of 15 mJ). The time-resolved infrared emission spectrum of Ag was recorded in the 1300- to 3600-cm{sup -1} spectral region using the Fourier transform infrared spectroscopy technique with a resolution of 0.02 cm{sup -1}. The time profiles of the measured lines have maxima at 5-6 {mu}s after a laser shot and display nonexponential decay with a decay time of 3-7 {mu}s. The lines reported here are given with an uncertainty of 0.0005-0.016 cm{sup -1}. The line classification is performed using relative line strengths expressed in terms of transition dipole matrix elements calculated with the help of the Fues model potential; these calculations show agreement with the large experimental and calculated data sets available in the literature. In addition to these data we also calculate transition probabilities and line and oscillator strengths for a number of transitions in the 1300- to 5000-cm{sup -1} range between (4d{sup 10})nl{sub j} states of Ag.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the Use of Fourier Transform Infrared (FT-IR) Spectroscopy and Synthetic Calibration Spectra to Quantify Gas Concentrations in a Fischer-Tropsch Catalyst System

One possible origin of prebiotic organic material is that these compounds were formed via Fischer-Tropsch-type (FTT) reactions of carbon monoxide and hydrogen on silicate and oxide grains in the warm, inner-solar nebula. To investigate this possibility, an experimental system has been built in which the catalytic efficiency of different grain-analog materials can be tested. During such runs, the gas phase above these grain analogs is sampled using Fourier transform infrared (FT-IR) spectroscopy. To provide quantitative estimates of the concentration of these gases, a technique in which high-resolution spectra of the gases are calculated using the high-resolution transmission molecular absorption (HITRAN) database is used. Next, these spectra are processed via a method that mimics the processes giving rise to the instrumental line shape of the FT-IR spectrometer, including apodization, self-apodization, and broadening due to the finite resolution. The result is a very close match between the measured and computed spectra. This technique was tested using four major gases found in the FTT reactions: carbon monoxide, methane, carbon dioxide, and water. For the ranges typical of the FTT reactions, the carbon monoxide results were found to be accurate to within 5% and the remaining gases accurate to within 10%. These spectra can then be used to generate synthetic calibration data, allowing the rapid computation of the gas concentrations in the FTT experiments.

Infrared Spectroscopy↗