Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Archimedes Brought to Light

Just over 100 years ago in the summer of 1906, a Danish scholar called Johan Ludvig Heiberg travelled to the famous Metochion library of the Church of the Holy Sepulcher in Constantinople. He had got wind of an intriguing medieval prayer book that had recently been found at the library, and which contained a series of Christian prayers written on parchment recycled from older books. But underneath the scrawlings of a 13th-century medieval monk, the battered manuscript also appeared to contain some strange Greek writing as well as mysterious drawings and mathematical symbols. When Heiberg saw the book, he soon realized that the hidden material in fact contained the thoughts of Archimedes of Syracuse (287-212 BC) - one of the greatest thinkers of the ancient world. It was in November 2003, while on my way to a conference in Germany, that I first realized that the technique might help to uncover the hidden writings in the Archimedes Palimpsest. I had been reading an article in the German magazine GEO about the manuscript and, having previously used X-rays to detect metals in biological systems, realized that XRF could help to detect iron and other common elements in the ink. I immediately e-mailed Abigail Quandt, a conservator at the Walters Art Museum, who was part of a team that had been put in charge of the Archimedes manuscript. I was delighted to find that the team, led by her colleague William Noel, was looking for new ways to study this ancient book. Indeed, it turned out that two other researchers - Gene Hall from Rutgers University and Bob Morton from the oil firm ConocoPhillips - had also suggested using XRF imaging. Another team member - Johns Hopkins University physicist Bill Christens-Barry - had already been thinking of using X-rays too. In March 2004 Hall and the team carried out the first tests on the Palimpsest using X-rays from a commercial generator. Although these tests were promising, the results confirmed my belief that synchrotron radiation could be much better because it would allow the book to be scanned much faster and with higher resolution. Indeed, I had already begun collaborating with my SLAC colleague Martin George, who helped to develop an XRF system that could image and scan the Palimpsest at high speed. It consisted of a computer-controlled stage that could hold a single leaf from the book and be moved from side to side so that the X-ray beam from SLAC's powerful SPEAR3 accelerator could be scanned across the sample. A 2D image of the page could then be built up by plotting the intensity of the fluorescent X-rays at a particular energy. The problem with imaging a delicate object like the Palimpsest using intense beams of X-rays is that it can be damaged if exposed for too long. Working with Gregory Young from the Conservation Institute in Ottawa, Canada, we carried out tests on a piece of parchment from a will written in 1870 that had been given to us by Quandt at the Walters Art Museum from her private collection. We found that if the parchment is moved sufficiently quickly so that the beam dwells for no longer than 0.1 s on every area through which it is passing, then no measurable damage occurs to the document's fibers. The only snag was that when the beam reached the edges of a particular line of the document, the stage holding the individual pages had to stop briefly and step down to the next line - a process that could take as long as 1 s. To avoid overexposure during these stops, we added a fast pneumatic beam shutter to the computerized scanning system, which remained open only when the parchment was moving. Our tests at SLAC proved so successful that we were able to persuade the Archimedes team to let us use our equipment on the real Palimpsest. The team arrived in May 2005 with 3 test pages and we were soon able to image half of one page at a resolution of 250 dots per centimeter in just 30 hours (Nature 435 257). We then used algorithms developed by Keith Knox, a physicist from Boeing, to convert the raw data into 2D images. In all of our measurements we were most interested in the fluorescence from iron, which is the most common element in the ink. But by placing suitable electronic 'windows' on the detector, we were able to simultaneously also record the signal from other elements, including calcium, zinc, barium and copper. The iron XRF image clearly revealed Archimedes writing under one of the forged paintings that had been added in the 20th century and - in the next two runs during March and August last year - we were able to scan various texts that could not be revealed with other techniques as well as some writings that do not appear anywhere else. By installing better detectors and by including a new readout system that had been developed by our colleague Alex Garachtchenko, we can now scan a whole page in just 12 hours with the X-ray beam sweeping over each 40 {micro}m2 area of the sample in just 3 ms.

43 PARTICLE ACCELERATORS↗

Splitting of the pygmy dipole resonance in {sup 138}Ba and {sup 140}Ce observed in the ({alpha},{alpha}{sup '}{gamma}) reaction

The N=82 nuclei {sup 140}Ce and {sup 138}Ba have been investigated by means of the ({alpha},{alpha}{sup '}{gamma}) coincidence method to study the pygmy dipole resonance (PDR). The experiments have been performed at the AGOR cyclotron at KVI, Groningen, at a primary beam energy of E{sub {alpha}}=136 MeV. The Big-Bite Spectrometer and seven large-volume high-purity germanium detectors were used in coincidence to perform a simultaneous spectroscopy of the scattered {alpha} particles and the {gamma} decay. The comparison with results of nuclear resonance fluorescence experiments reveals a splitting of the PDR into two components. Up to about 6 MeV the same states that could be observed in ({gamma},{gamma}{sup '}) are also excited in {alpha}-scattering experiments, whereas the higher-lying states are missing in the ({alpha},{alpha}{sup '}{gamma}) reaction. This indicates a structural splitting of the PDR into two modes with different underlying structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

Detection of radionuclides emitting short-range radiation, such as {alpha} and low-energy {beta} particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed {sup 241}Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cylindrical quadrupole ion trap in combination with an electrospray ion source for gas-phase luminescence and absorption spectroscopy

A relatively simple setup for collection and detection of light emitted from isolated photo-excited molecular ions has been constructed. It benefits from a high collection efficiency of photons, which is accomplished by using a cylindrical ion trap where one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The geometry permits nearly 10% of the emitted light to be collected and, after transmission losses, approximately 5% to be delivered to the entrance of a grating spectrometer equipped with a detector array. The high collection efficiency enables the use of pulsed tunable lasers with low repetition rates (e.g., 20 Hz) instead of continuous wave (cw) lasers or very high repetition rate (e.g., MHz) lasers that are typically used as light sources for gas-phase fluorescence experiments on molecular ions. A hole has been drilled in the cylinder electrode so that a light pulse can interact with the ion cloud in the center of the trap. Simulations indicate that these modifications to the trap do not significantly affect the storage capability and the overall shape of the ion cloud. The overlap between the ion cloud and the laser light is basically 100%, and experimentally >50% of negatively charged chromophore ions are routinely photodepleted. The performance of the setup is illustrated based on fluorescence spectra of several laser dyes, and the quality of these spectra is comparable to those reported by other groups. Finally, by replacing the optical system with a channeltron detector, we demonstrate that the setup can also be used for gas-phase action spectroscopy where either depletion or fragmentation is monitored to provide an indirect measurement on the absorption spectrum of the ion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A color x-ray camera for 2–6 keV using a mass produced back illuminated complementary metal oxide semiconductor sensor

There are several reports in the scientific literature of the use of mass-produced charge coupled device or complementary metal oxide semiconductor (CMOS) sensors as x-ray detectors that combine high spatial resolution with significant energy resolution. Exploiting a relatively new especially favorable ambient-temperature back-illuminated CMOS sensor, we report the development of a spectroscopic x-ray camera having particularly impressive performance for 2-6 keV photons. This instrument has several beneficial characteristics for advanced x-ray spectroscopy studies in the laboratory, at synchrotron light sources, at x-ray free electron lasers, or when using pulsed x-ray sources such as for laser plasma physics research. These characteristics include fine position and energy resolution for individual photon events, high saturation rates, frame rates above 100 Hz, easy user maintenance for damaged sensors, and software for real-time processing. We evaluate this camera as an alternative to traditional energy-dispersive solid-state detectors, such as silicon drift detectors, and also illustrate its use in a very high resolution wavelength-dispersive x-ray fluorescence spectrometer (i.e., x-ray emission spectrometer) that has recently been reported elsewhere [W. M. Holden et al., Rev. Sci. Instrum. 88(7), 073904 (2017)].

47 OTHER INSTRUMENTATION↗

Improved scintillation detector performance via a method of enhanced layered coatings

Increasing demand for better detection performance with a simultaneous reduction in size, weight and power consumption has motivated the use of compact semiconductors as photo-converters for many gamma-ray and neutron scintillators. The spectral response of devices such as silicon avalanche photodiodes (APDs) is poorly matched to many common high-performance scintillators. We have developed a generalized analytical method that utilizes an optical reference database to match scintillator luminescence to the excitation spectrum of high quantum efficiency semiconductor detectors. This is accomplished by the fabrication and application of a series of high quantum yield, short fluorescence lifetime, wavelengthshifting coatings. Furthermore, we show here a 22% increase in photoelectron collection and a 10% improvement in energy resolution when applying a layered coating to an APD-coupled, cerium-doped, yttrium oxyorthosilicate (YSO:Ce) scintillator. Wavelength-shifted radioluminescence emission and rise time analysis are also discussed.

36 MATERIALS SCIENCE↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

X-ray beam method for displacement measurement in hostile environments

A new method of extensometry using an X-ray beam was devised, and the results of current testing reveal it to be highly feasible. This technique has been shown to provide a non-contacting system that is immune to problems associated with density variations in gaseous environments, that plague currently available optical methods. This advantage is a result of the non-refracting penetrating nature of X-rays. The method is based on X-ray-induced X-ray fluorescence of targets, which subsequently serve as fudicial markers. Some target materials have melting points over 1600 degrees C which will facilitate measurement at extremely high temperatures. A highly focused intense X-ray beam, which is produced using a Johansen 'bent crystal', is then scanned across the target, which responds by fluorescing X-rays when stimulated by the incident beam. This secondary radiation is monitored using a detector. By carefully measuring beam orientation, change in target edge position can be determined. Many variations on this basic theme are now possible such as two targets demarcating a gage length, or a beam shadowing method using opaque targets.

Jordan, Eric H.↗

Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of gamma rays with specific energies that are characteristic of the emitting isotope. NRF promises the unique capability of directly quantifying a specific isotope without the need for unfolding the combined responses of several fissile isotopes as is required in other measurement techniques. We have analyzed the potential of NRF as a non-destructive analysis technique for quantitative measurements of Pu isotopes in spent nuclear fuel (SNF). Given the low concentrations of 239Pu in SNF and its small integrated NRF cross sections, the main challenge in achieving precise and accurate measurements lies in accruing sufficient counting statistics in a reasonable measurement time. Using analytical modeling, and simulations with the radiation transport code MCNPX that has been experimentally tested recently, the backscatter and transmission methods were quantitatively studied for differing photon sources and radiation detector types. Resonant photon count rates and measurement times were estimated for a range of photon source and detection parameters, which were used to determine photon source and gamma-ray detector requirements. The results indicate that systems based on a bremsstrahlung source and present detector technology are not practical for high-precision measurements of 239Pu in SNF. Measurements that achieve the desired uncertainties within hour-long measurements will either require stronger resonances, which may be expressed by other Pu isotopes, or require quasi-monoenergetic photon sources with intensities that are approximately two orders of magnitude higher than those currently being designed or proposed.This work is part of a larger effort sponsored by the Next Generation Safeguards Initiative to develop an integrated instrument, comprised of individual NDA techniques with complementary features, that is fully capable of determining Pu mass in spent fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sub-pixel high-resolution imaging of high-energy x-rays inspired by sub-wavelength optical imaging

We have developed and demonstrated an image super-resolution method—XR-UNLOC: X-Ray UNsupervised particle LOCalization—for hard x-rays measured with fast-frame-rate detectors that is an adaptation of the principle of photo-activated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), which enabled biological fluorescence imaging at sub-optical-wavelength scales. We demonstrate the approach on experimental coherent Bragg diffraction data measured with 52 keV x-rays from a nanocrystalline sample. From this sample, we resolve the fine fringe detail of a high-energy x-ray Bragg coherent diffraction pattern to an upsampling factor of 16 of the native pixel pitch of 30 μ m of a charge-integrating fastCCD detector. This was accomplished by analysis of individual photon locations in a series of “nearly-dark” instances of the diffraction pattern that each contain only a handful of photons. Central to our approach was the adaptation of the UNLOC photon fitting routine for PALM/STORM to the hard x-ray regime to handle much smaller point spread functions, which required a different statistical test for photon detection and for sub-pixel localization. A comparison to a photon-localization strategy used in the x-ray community (“droplet analysis”) showed that XR-UNLOC provides significant improvement in super-resolution. We also developed a metric by which to estimate the limit of reliable upsampling with XR-UNLOC under a given set of experimental conditions in terms of the signal-to-noise ratio of a photon detection event and the size of the point spread function for guiding future x-ray experiments in many disciplines where detector pixelation limits must be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute concentrations of O/3P/ in the lower thermosphere at night

A rocketborne instrument module for detecting atomic oxygen concentrations by the resonance fluorescence technique is reported. The module contained a source lamp emitting O I 1304 A photons and a detector for the scattered photons. The module was constructed so that it could be coupled to a fast flow reactor for calibration purposes. During the flight the module was radially deployed from the payload on an oscillating boom with a maximum extension of 90 cm from the skin. Analysis of the initial flight data indicates that the shock formed by the motion of the rocket had a substantial effect on the data and the maximum concentration of the layer at 93 km was about 1.1 x 10 to the 11th/cu cm.

Sharp, W. E.↗

Non-intrusive Space Shuttle Main Engine nozzle exit diagnostics

The results of a conceptual design study on the feasibility of nonintrusive optical diagnostics have shown that UV laser-excited Raman scattering can furnish reliable and accurate temperature and multiple-species data for the Space Shuttle Main Engine's exhaust flow. Enhanced OH flow tagging by UV photodissociation of H2O was used in velocity measurements; a time-delayed pulsed dye laser beam at 308 nm excites fluorescence from OH, and the location of the convected enhanced OH zone is measured with an optical multichannel detector.

Shirley, John A.↗

A Passive Method for Detecting Vegetation Stress from Orbit: Chlorophyll Fluorescence Spectra from Fraunhofer Lines

Solar-stimulated chlorophyll fluorescence measured with the Fraunhofer line depth method has correlated well with vegetation stress in previous studies. However, the instruments used in those studies were limited to a single solar absorption line (e.g. 656.3 nm), obviating the red/far-red ratio (R/FR) method. Optics and detector technology have reached the level whereby multiple, very narrow Fraunhofer lines are resolvable. Thirteen such lines span the visible spectrum in the red to far-red region where chlorophyll fluorescence occurs. Fluorescence intensities at the 13 Fraunhofer line wavelengths were used to model emission spectra. The source data were collected for summer and fall bean crops (Phaseolus vulgaris L.) subjected to various levels of nitrogen fertilization. The intensities were adjusted to account for Fraunhofer line depth and atmospheric transmittance. Multiple R/FR fluorescence ratios, calculated from the modeled fluorescence spectra, correlated strongly with leaf chlorophyll concentration and well with applied nitrogen. The ratio yielding the best correlation with chlorophyll utilized red fluorescence at the 694.5 nm Fraunhofer line and farred fluorescence at the 755.6 nm Fraunhofer line. Twenty R/FR ratios, each evaluated for the maximum differential between low and high (optimal) nitrogen treatments, ranked higher in some cases and lower in others, possibly related to the time of year the crops were grown and the stage of growth of the crops. Ratios with 728.9 nm and 738.9 nm in the denominator consistently ranked in the lowest and next lowest quartile, respectively. Ratios of the 656.3 nm Fraunhofer line and the 755.6 nm line consistently ranked highest for the summer crop. Ratios with 755.6 nm in the denominator ranked in the upper quartile for 10 out of 12 measurement dates. Differences in ratio ranking indicate that physiological conditions may be estimated using selected ratios of Fraunhofer lines within the context of R/FR analysis. A passive instrument designed to monitor R/FR chlorophyll fluorescence (i.e. vegetation stress) from orbit could be built today.

Theisen, Arnold F.↗

Fluorescence decay-time constants in organic liquid scintillators

The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector Low Energy Neutrino Astronomy (LENA). In particular, the impact of the measured values to the search for proton decay via p{yields}K{sup +}{nu} is evaluated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Large Drift Detector Array Lunar Orbiter Spectrometer

Measurement of-rays from the surface of objects can tell us about the chemical composition. Absorption of radiation causes characteristic fluorescence from material being irradiated. By measuring the spectrum ofthe radiation and identifying lines in the spectrum, the emitting element (s) can be identified.

Gaskin, Jessica A.↗

Hard X-ray fluorescence spectroscopy of high pressure cavitating fluids in aluminum nozzles

X-rays are frequently used to study the internal geometry of dense objects, and to measure the density of multiphase flows. However, quantitatively measuring fluid density inside a metallic object such as a high pressure spray nozzle is difficult. X-rays of sufficiently high energy to penetrate a metal object are not appreciably absorbed by the fluid inside. This requires the use of plastic or beryllium test sections, which are not suited to high pressure conditions. We present a high-energy X-ray fluorescence technique which can overcome this problem. The experiments were conducted at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. A hydrocarbon fluid was seeded with cerium nanoparticles. The fluid was pumped at high pressure through aluminum nozzles with inner diameters of 0.36-0.90 mm and wall thicknesses of 2-3 mm. A collimated, monochromatic 42.5 keV X-ray beam excited K-edge fluorescence from the cerium. The K-alpha emission lines at 34-35 keV were recorded by a cryogenic germanium detector. Changes in fluid density due to cavitation of the liquid inside the nozzle were measured by raster scanning the nozzle across the beam. A spatial resolution of 20 x 20 mu m(2) was achieved with a slitted beam, which was improved to 5 x 10 mu m(2) with X-ray focusing mirrors. The uncertainty in the path-integrated vapor fraction was 30-40 mu m at 95% confidence. A limitation of this approach is that for low vapor pressure fluids, the nanoparticles increase the vapor pressure of the fluid and act as additional nucleation sites. These experiments demonstrate a path forward for measurements of multiphase flows inside metal components under conditions that are not feasible in optically accessible materials.

47 OTHER INSTRUMENTATION↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗