Corrosion Testing Trade Study on Testing Methods in Molten Salts

In assessing molten salt compatibility with structural materials, static testing is often reported because it is easy to conduct. However, in order to assess mass transfer, where material dissolves in the salt in the hot section and may precipitate out of the liquid in colder regions, a flowing salt experiment in a temperature gradient is needed. While a forced convection or pumped loop produces prototypic flowing conditions, it also is a multi-million dollar investment. Among the less expensive dynamic testing options, the thermal convection loop (TCL) was favored during the 1960’s development of molten salt reactor technology. Because the workforce and core facilities are currently available to conduct TCL experiments, it is the least expensive strategy to evaluate candidate structural alloys in flowing molten salt conditions.

36 MATERIALS SCIENCE↗

Numerical Simulation and Experimental Study of the Gas–Solid Flow Behavior Inside a Full-Loop Circulating Fluidized Bed: Evaluation of Different Drag Models

Both experimental and computational studies of the fluidization of high-density polyethylene (HDPE) particles in a small-scale full-loop circulating fluidized bed (CFB) are conducted. Experimental measurements of pressure drop are taken at various locations along the bed. The solids circulation rate is measured with an advanced particle image velocimetry (PIV) technique. Bed height of the quasi-static region in the standpipe is also measured. Comparative numerical simulations are performed with a computational fluid dynamics solver utilizing a discrete element method (CFD-DEM). Here, this paper examines the effect of different drag laws used in the CFD simulations through a detailed and direct comparison with experimental data from a small-scale, full-loop circulating fluidized bed. The Hill–Koch–Ladd drag correlation was shown to have good agreement with respect to system component pressure drop and inventory height in the standpipe.

42 ENGINEERING↗

The Development of an INL Capability for High Temperature Flow, Heat Transfer, and Thermal Energy Storage with Applications in Advanced Small Modular Reactors, High Temperature Heat Exchangers, Hybrid Energy Systems, and Dynamic Grid Energy Storage C

The overall goal of this project is to support Idaho National Laboratory in developing a new advanced high temperature multi fluid multi loop test facility that is aimed at investigating fluid flow and heat transfer, material corrosion, heat exchanger characteristics and instrumentation performance, among others, for nuclear applications. Specifically, preliminary research has been performed at The Ohio State University in the following areas: 1. A review of fluoride molten salts’ characteristics in thermal, corrosive, and compatibility performances. A recommendation for a salt selection is provided. Material candidates for both molten salt and helium flow loop have been identified. 2. A conceptual facility design that satisfies the multi loop (two coolant loops [i.e., fluoride molten salts and helium]) multi purpose (two operation modes [i.e., forced and natural circulation]) requirements. Schematic models are presented. The thermal hydraulic performances in a preliminary printed circuit heat exchanger (PCHE) design have been estimated. 3. An introduction of computational methods and models for pipe heat loss analysis and cases studies. Recommendations on insulation material selection have been provided. 4. An analysis of pipe pressure rating and sizing. Preliminary recommendations on pipe size selection have been provided. 5. A review of molten fluoride salt preparation and chemistry control. An introduction to the experience from the Molten Salt Reactor Experiment at Oak Ridge National Laboratory has been provided. 6. A review of some instruments and components to be used in the facility. Flowmeters and Grayloc connectors have been included. This report primarily presents the conclusions drawn from the extensive review of literatures in material selections and the facility design progress at the current stage. It provides some useful guidelines in insulation material and pipe size selection, as well as an introductory review of facility process and components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Natural circulation FLiBe loop overview

A new large natural circulation FLiBe loop has operated for the first time in 40 years. Reaching temperatures above 700 C with stable flow rates around 5 cm/s, the loop exhibits a range of flow phenomena pertinent to high temperature natural circulation safety systems for nuclear reactors. This paper discusses the system and several operating conditions spanning a wide range of behavior to aid the development of other systems, simulation benchmarks, or system-codes. Analysis of heat transport phenomena indicates that standard Nusselt number correlations apply to a first approximation. More accurate salt-freezing models may be necessary for air-cooled salt-systems due to the insulating affect of the low thermal-conductivity frozen salt layer on the cold pipe walls.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A siphon mechanism for supplying prominence mass

A siphonlike mechanism for moving mass from the chromosphere to a gravitational well at the top of a magnetic loop to form a prominence is examined. The calculations assume no a priori flow velocity at the loop base. Instead, heating in the loop legs drives the flow. The prominence formation process requires two steps. First, the background heating rate must be reduced to on the order of 1 percent of the initial heating rate required to maintain the coronal loop. This forms an initial condensation at the top of the loop. Second, the heating must take place only in the loop legs in order to produce a pressure differential which drives mass up into the well at the top of the loop. The heating rate in the loop must be increased once the prominence has begun to form, or full prominence densities cannot be achieved in a reasonable time. It is concluded that this heating driven siphonlike mechanism is feasible for producing and maintaining prominences.

Poland, A. I.↗

An Overview of the XRT Observations for the September 10 2017 X Flare

The September 10 2017 X8 flare was one of the biggest of the current solar cycle, and it was also incredibly well observed. This presentation will review the available XRT data for this flare. XRT observed the initial flux rope eruption, which was also well observed by AIA and SUVI. XRT data is missing for some of the impulsive phase of the flare, but the late phase shows some very interesting features. There is some nice XRT imaging of a plasma sheet above cusp-shaped loops between 16:47 and 18:39 UT. After 18:40 UT, a double loop structure becomes apparent, with a more rounded loop nested within a larger, cusp-shaped structure. The flare loops continue to grow, and at around 1 UT on September 11, supra-arcade down flows and shrinking loops become visible. There is also interesting data in the late phase of this flare from RHESSI and the Expanded Owens Valley Solar Array (EOVSA).

Reeves, Kathy↗

Prediction of PbLi fluid flow and temperature field in a thermal convection loop for qualification of fusion materials

Two modeling tools, a thermohydraulics code and a computational model in COMSOL Multiphysics, have been developed, tested and then applied to the analysis of fluid flow and heat transfer in a thermal convection loop (TCL). Such a device has recently been used to experimentally evaluate corrosion compatibility of APMT (Fe–21Cr–5Al–3Mo) steel with high-temperature molten eutectic lead-lithium (PbLi) alloy at Oak Ridge National Lab, TN, USA. Here, the 1-D thermohydraulics code allows for rapid calculations of the loop parameters as a function of the applied heat flux. The supplemental COMSOL finite-element computations provide detailed 3-D velocity and temperature field data but are much more time consuming. Both modelling tools demonstrate an excellent agreement in the computed circulation velocity as well as maximum and minimum temperatures. The performed TCL analysis focuses on flow development in the “hot” and “cold” legs, formation of Dean vortices in corner regions, blocking effect of the immersed samples, and radiative and convective cooling effects under the experiment-relevant conditions for Prandtl number Pr = 0.015, Grashof numbers Gr ~10 7 , and Reynolds numbers Re ~10 4 .

36 MATERIALS SCIENCE↗

The effects of nonequilibrium ionization on the radiative losses of the solar corona

The emissivity of the ions of carbon and oxygen has been recalculated for a set of solar coronal loop models with a steady state siphon flow. The ion densities were calculated from the plasma velocities, temperatures, and densities of the models, and large departures from equilibrium were found. For purposes of comparison, the emissivity was calculated with and without the approximation of ionization equilibrium. Considerable differences in the radiative loss function Lambda(T) curve between equilibrium and nonequilibrium conditions were found. The nonequilibrium Lambda(T) function was then used to solve again the steady state flow equations of the loop models. The differences in the structure of these models with respect to the models calculated adopting the Lambda(T) curve in equilibrium are discussed.

Spadaro, D.↗

Low Flow Vortex Shedding Flow Meter for Hypergolics/all Media

A family of vortex shedding flow meters, for measurement of hypergol flows, was designed and fabricated. The test loops to evaluate the flow meters for water flow, as well as Freon -113 flow which simulates the hypergolic fluids, were modified and constructed to utilize a pump system which has an output capacity of 200 gpm. Test runs were conducted on the small 1/2 inch model with Freon 113 and on the larger models with water. Results showed that the linearity between the frequency of the vortices and the flow rate of the fluids was very close to that of the turbine flow meter. It is suggested that the vortex shedding flow meter is a possible replacement for the existing turbine type.

Thinh, Ngo Dinh↗

Split radiator design for heat rejection optimization for a waste heat recovery system

A cooling system provides improved heat recovery by providing a split core radiator for both engine cooling and condenser cooling for a Rankine cycle (RC). The cooling system includes a radiator having a first cooling core portion and a second cooling core portion. An engine cooling loop is fluidly connected the second cooling core portion. A condenser of an RC has a cooling loop fluidly connected to the first cooling core portion. A valve is provided between the engine cooling loop and the condenser cooling loop adjustably control the flow of coolant in the condenser cooling loop into the engine cooling loop. The cooling system includes a controller communicatively coupled to the valve and adapted to determine a load requirement for the internal combustion engine and adjust the valve in accordance with the engine load requirement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of two-phase flow in a reduced gravity environment

A test loop was designed and fabricated for observing and measuring pressure drops of two-phase flow in reduced gravity. The portable flow test loop was then tested aboard the NASA-JSC KC135 reduced gravity aircraft. The test loop employed the Sundstrand Two-Phase Thermal Management System (TPTMS) concept which was specially fitted with a clear two-phase return line and condenser cover for flow observation. A two-phase (liquid/vapor) mixture was produced by pumping nearly saturated liquid through an evaporator and adding heat via electric heaters. The quality of the two-phase flow was varied by changing the evaporator heat load. The test loop was operated on the ground before and after the KC135 flight tests to create a one-gravity data base. The ground testing included all the test points run during the reduced gravity testing. Two days of reduced gravity tests aboard the KC135 were performed. During the flight tests, reduced-gravity, one-gravity, and nearly two-gravity accelerations were experienced. Data was taken during the entire flight which provided flow regime and pressure drop data for the three operating conditions. The test results show that two-phase pressure drops and flow regimes can be accurately predicted in zero-gravity.

Hill, D.↗

NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗

ATLAS LTCS Vertically Challenged System Lessons Learned

Re-planning of LTCS TVAC testing and supporting RTA (Receiver Telescope Assembly) Test Plan and Procedure document preparation. The Laser Thermal Control System (LTCS) is designed to maintain the lasers onboard Advanced Topographic Laser Altimeter System (ATLAS) at their operational temperatures. In order to verify the functionality of the LTCS, a thermal balance test of the thermal hardware was performed. During the first cold start of the LTCS, the Loop Heat Pipe (LHP) was unable to control the laser mass simulators temperature. The control heaters were fully on and the loop temperature remained well below the desired setpoint. Thermal analysis of the loop did not show these results. This unpredicted behavior of the LTCS was brought up to a panel of LHP experts. Based on the testing and a review of all the data, there were multiple diagnostic performed in order to narrow down the cause. The prevailing theory is that gravity is causing oscillating flow within the loop, which artificially increased the control power needs. This resulted in a replan of the LTCS test flow and the addition of a GSE heater to allow vertical operation.

Loop Heat Pipe↗

One-loop matching for quark dipole operators in a gradient-flow scheme

The quark chromoelectric dipole (qCEDM) operator is a CP-violating operator describing, at hadronic energies, beyond-the-standard-model contributions to the electric dipole moment of particles with nonzero spin. In this paper we define renormalized dipole operators in a regularization-independent scheme using the gradient flow, and we perform the matching at one loop in perturbation theory to renormalized operators of the same and lower dimension in the more familiar MS scheme. We also determine the matching coefficients for the quark chromo-magnetic dipole operator (qCMDM), which contributes for example to matrix elements relevant to CP-violating and CP-conserving kaon decays. The calculation provides a basis for future lattice QCD computations of hadronic matrix elements of the qCEDM and qCMDM operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic loops, downflows, and convection in the solar corona

Optical and extreme-ultraviolet observations of solar loop structures show that flows of cool plasma from condensations near the loop apex are a common property of loops associated with radiations whose maximum temperature is greater than approximately 7000 K and less than approximately 3,000,000 K. It is suggested that the mass balance of these structures indicates reconnection by means of plasma motion across field lines under rather general circumstances (not only after flares). It is shown that the cool material has lower gas pressure than the surrounding coronal medium. The density structure of the bright extreme ultraviolet loops suggests that downflows of cool gas result from isobaric condensation of plasma that is either out of thermal equilibrium with the local energy deposition rate into the corona, or is thermally unstable. The evidence is thought to indicate that magnetic fields act to induce a pattern of forced convection.

Foukal, P.↗

The heart works against gravity

The circulatory systems of vertebrate animals are closed, and blood leaves and returns to the heart at the same level. It is often concluded, therefore, that the heart works only against the viscous resistance of the system, not against gravity, even in vascular loops above the heart in which the siphon principle operates. However, we argue that the siphon principle does not assist blood flow in superior vascular loops if any of the descending vasculature is collapsible. If central arterial blood pressure is insufficient to support a blood column between the heart and the head, blood flow ceases because of vascular collapse. Furthermore, the siphon principle does not assist the heart even when a continuous stream of blood is flowing in a superior loop. The potential energy gained by blood as it is pumped to the head is lost to friction in partially collapsed descending vessels and thus is not regained. Application of the Poiseuille equation to flow in collapsible vessels is limited; resistance depends on flow rate in partially collapsed vessels with no transmural pressure difference, but flow rate is independent of resistance. Thus the pressure developed by the heart to establish a given flow rate is independent of the resistance occurring in the partially collapsed vessels. The pressure depends only on the height of the blood column and the resistance in the noncollapsed parts of the system. Simple laboratory models, involving water flow in collapsible tubing, dispel the idea that the siphon principle facilitates blood flow and suggest that previously published results may have been affected by experimental artifact.

Review, Tutorial↗

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗