Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fault Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

First Ever Polymer Flood Field Pilot - A Game Changer to Enhance the Recovery of Heavy Oils on Alaska’s North Slope

The development pace of Alaska’s vast, 20-25 billion barrels, heavy oil resources has been very slow due to high development costs and low oil recovery using conventional waterflood, and the impracticality of deploying thermal methods due to the presence of continuous permafrost. Although, polymer flooding has attracted attention and has become a promising EOR technique in heavy oil reservoirs due to the extensive application of horizontal wells and advancement of polymer flooding technology, no field tests have been performed to date in Alaska’s underdeveloped heavy oil reservoirs. The overall objective of this research is to perform a field experiment to validate the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. Two pre-existing pairs of horizontal injection and production wells in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field are currently being used for the field experiment. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 at 600 ppm (4 cP viscosity) concentration ramping up to 1,800 ppm (45 cP viscosity) over a three week time period, and has been maintained at an average concentration of ~1,800 ppm. Current injection rates in the two horizontal injectors are ~2,200 and 600 bwpd. Laboratory experiments to determine the polymer retention, optimum water salinity, synergistic effects of water salinity and polymer, and handling of produced fluids, in support of the field experiment, are currently ongoing. Similarly, reservoir simulation of coreflood behavior and history match of previous waterfloods to predict polymer flood performance in the project area are also conducted in parallel. The field data and scientific knowledge that have been collected since the start of the injection indicates that the field pilot is performing as predicted. To date, no unexpected injectivity issues or polymer breakthrough have been encountered, and the two horizontal producers are showing positive response to the polymer injection, resulting in incremental increase in oil production rate. Since the research is still in its early stages, selected field, laboratory and simulation results are presented and discussed to highlight the integrative approach adopted in this first ever polymer flood field pilot in Alaska.

02 PETROLEUM↗

Assessing Seismic Risk for CO2 Geologic Storage: Comparative Analysis of the Delaware Basin and Basin and Range Province Projects

ABSTRACT: Effective management of induced seismicity is critical for safe and sustainable CO2 storage. This study evaluates fault slippage risks in the Delaware Basin (Texas) and Basin and Range Province (Utah), integrating geological, operational, and geomechanical parameters to assess fault stability and seismic hazard mitigation. In the Delaware Basin, two sites were analyzed under an injection rate of 20,000 bbl/day over 25 years. One site showed low fault slip risk, while the other exhibited higher reactivation potential due to proximity to critically stressed faults. Sensitivity analysis revealed that increased pore pressure significantly heightened slip potential, highlighting the necessity of precise pressure control and real-time monitoring. In the Basin and Range Province, fault stability was evaluated at Neck of the Desert, Escalante Desert, Parowan, and Beaver sites under injection rates of 8,750 bbl/day per site over 30 years. Minimal fault slip risk was observed at Neck of the Desert and Escalante Desert sites, whereas Parowan and Beaver sites exhibited elevated slip potential due to semi-critically stressed faults sensitive to modest pore pressure increases. The findings demonstrate that fault slippage analysis, combined with sensitivity analysis of pore pressure and friction coefficients, is essential for understanding seismic risks. Continuous monitoring, adaptive injection management, and rigorous geomechanical analysis are key strategies for minimizing induced seismicity in CO2 sequestration projects.

58 GEOSCIENCES↗

On the physics-based processes behind production-induced seismicity in natural gas fields

Induced seismicity due to natural gas production is observed at different sites worldwide. Common understanding states that the pressure drop caused by gas production leads to compaction, which affects the stress field in the reservoir and the surrounding rock formations and hence reactivates preexisting faults and induces earthquakes. We show that the multiphase fluid flow involved in natural gas extraction activities should be included. We use a fully coupled fluid flow and geomechanics simulator, which accounts for stress-dependent permeability and linear poroelasticity, to better determine the conditions leading to fault reactivation. In our model setup, gas is produced from a porous reservoir, divided into two compartments that are offset by a normal fault. Results show that fluid flow plays a major role in pore pressure and stress evolution within the fault. Fault strength is significantly reduced due to fluid flow into the fault zone from the neighboring reservoir compartment and other formations. We also analyze scenarios for minimizing seismicity after a period of production, such as (i) well shut-in and (ii) gas reinjection. In the case of well shut-in, a highly stressed fault zone can still be reactivated several decades after production has ceased, although on average the shut-in results in a reduction in seismicity. In the case of gas reinjection, fault reactivation can be avoided if gas is injected directly into the compartment under depletion. However, gas reinjection into a neighboring compartment does not stop the fault from being reactivated.

03 NATURAL GAS↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Induced seismicity potential based on probabilistic geomechanics for the San Juan Basin CarbonSAFE project

Although geologic carbon sequestration projects have yet to induce — or may never induce — a damaging earthquake, experiences from other deep injection industries such as hydraulic fracturing, enhanced geothermal systems, and saltwater disposal suggest that effective quantitative seismic risk assessment is necessary for deep saline carbon capture and sequestration (CCS) projects. One such imminent CCS project is the San Juan Basin CarbonSAFE Phase III program. We use Monte Carlo probabilistic geomechanical analyses combined with observations of the geologic and operational parameters of the San Juan Basin site and suggest that this project is of low-induced seismic risk. The primary analysis is split into four sections. First, we assess the literature for faults and past seismicity, and at least five faulting scenarios are directly relevant. Second, we develop and calibrate an integrated earth model for the project site. Third, we perform Monte Carlo simulations that consider reasonable uncertainties of the geomechanical parameters. Of five tested faulting scenarios, only one presents high Coulomb failure functions, but fourth, we determine the risk to be low based on the combined lack of historical seismicity, the geologic framework of the faulting scenario, and the presence of saltwater injection at the same depth as the proposed supercritical carbon dioxide injection. The most sensitive parameters in the geomechanical calculations are the fault dip and the coefficient of friction. The least sensitive are the fault strike and the orientation of the maximum horizontal principal stress.

58 GEOSCIENCES↗

Effects of the distribution and evolution of the coefficient of friction along a fault on the assessment of the seismic activity associated with a hypothetical industrial-scale geologic CO 2 sequestration operation

Carbon capture and storage (CCS) in geological formations is considered as a promising option that could limit CO 2 emissions from human activities into the atmosphere. However, there is a risk that pressure buildup inside the storage formation can induce slip along preexisting faults and create seismic event felt by the population. To prevent this to happen a geomechanical fault stability analysis should be performed, considering uncertainties of input parameters. In this paper, we investigate how the distribution of the coefficient of friction and the applied frictional law could influence the assessment of fault stability and the characteristics of potential injection-induced seismic events. Our modelling study is based on a hypothetical industrial-scale carbon sequestration project located in the Southern San Joaquin Basin in California, USA, where the stability on a major (25 km long) fault that bounds the sequestration site is assessed during 50 years of CO 2 injection. We conduct nine simulations in which the distributions of the coefficients of static and dynamic friction are changed to simulate a hardening and softening phase before and during rupture. Here, our main findings are: (i) variations in friction along the fault have an important effect on the predicted seismic activity, with maximum magnitude ranging from 1.88 to 5.88 and number of seismic events ranging from 338 to 3272; (ii) the extreme values of the coefficient of friction (lowest and highest) present along the rupture area control how much stress is accumulated before rupture; and (iii) an argillaceous caprock can prevent the development of large magnitude seismic events but favor the occurrence of a large number of smaller events.

58 GEOSCIENCES↗

Geomechanical simulation of the stress tensor rotation caused by injection of cold water in a deep geothermal reservoir

We present a three-dimensional thermohydromechanical numerical study of the evolution and distribution of the stress tensor within the northwest part of The Geysers geothermal reservoir (in California), including a detailed study of the region around one injection well from 2003 to 2012. Initially, after imposing a normal faulting stress regime, we calculated local changes in the stress regime around injection wells. Our results were compared with previously published studies in which the stress state was inferred from inverting the focal plane mechanism of seismic events. Our main finding is that changes in stress tensor orientation are caused by injection-induced progressive cooling of the reservoir, as well as by the seasonal variations in injection rate. Because of the gravity flow and cooling around a liquid zone formed by the injection, the vertical stress reduction is larger and propagates far below the injection well. At the same time, the horizontal stress increases, mostly because of stress redistribution below and above the cooling area. These two phenomena cause the rotation of the stress tensor and the appearance of a strike-slip regime above, inside, and below the cooling area. The cooling and the associated rotation of the stress regime can play a significant role in the observed long-term deepening of the microseismicity below active injection wells.

58 GEOSCIENCES↗

Spatially resolved band alignments at Au-hexadecanethiol monolayer-GaAs(001) interfaces by ballistic electron emission microscopy

We study structural and electronic inhomogeneities in Metal—Organic Molecular monoLayer (OML)—semiconductor interfaces at the sub-nanometer scale by means of in situ Ballistic Electron Emission Microscopy (BEEM). BEEM imaging of Au/1-hexadecanethiols/GaAs(001) heterostructures reveals the evolution of pinholes density as a function of the thickness of the metallic top-contact. Using BEEM in spectroscopic mode in non-short-circuited areas, local electronic fingerprints (barrier height values and corresponding spectral weights) reveal a low-energy tunneling regime through the insulating organic monolayer. At higher energies, BEEM evidences new conduction channels, associated with hot-electron injection in the empty molecular orbitals of the OML. Corresponding band diagrams at buried interfaces can be thus locally described. The energy position of GaAs conduction band minimum in the heterostructure is observed to evolve as a function of the thickness of the deposited metal, and coherently with size-dependent electrostatic effects under the molecular patches. Such BEEM analysis provides a quantitative diagnosis on metallic top-contact formation on organic molecular monolayer and appears as a relevant characterization for its optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of Faults Susceptible to Induced Seismicity Final Report

The primary objective of this project (referred to as the State of Stress project or SoS project) was to predict the presence of faults susceptible to movement in the presence of fluid injection as a consequence of vertical pressure migration from the storage unit to the crystalline basement. These faults included those difficult to resolve with traditional interpretations of surface seismic: faults with no or minimal offset, faults in the crystalline basement where no seismic reflectors are present, subseismic faults (due to size), and faults undetected (e.g., due to unfavorable orientation with surface seismic survey).

25 ENERGY STORAGE↗

Induced microseismicity and tremor signatures illuminate different slip behaviours in a natural shale fault reactivated by a fluid pressure stimulation (Mont Terri)

SUMMARY Fault slip induced by fluid perturbation in shale formations may only lead to a sparse seismicity. However, fault slip may strongly impact the integrity of shale formations that serve as caprocks for geological reservoirs holding buoyant fluids such as CO2, natural gas or hydrogen. A better understanding of the fluid reactivation processes of fault and the seismic triggering process is therefore critical for reservoir monitoring and fault stability. Here we analyse the seismic responses of a shale fault exposed to fluid pressurization during an in situ field-scale injection experiment at ∼340 m depth in the Mont Terri underground research laboratory (Switzerland). Two main types of seismic signals are observed as the fault was activated and started to slowly slip. After an aseismic phase, we observed tremor signatures and an increase in noise amplitude, which were directly associated with the slowly propagating fault slip in response to fluid injection. These signatures were later followed by micro-earthquakes that seem to occur further away from the fluid-pressurized area. We interpret these micro-earthquakes to be triggered by stress perturbations from the main slip growth. These two classes of seismic responses therefore highlight two different processes. Tremors seem to be a more direct observation for the fluid-induced slip propagation than micro-earthquakes. Even hidden in the noise, they precede earthquake failures, thus providing a useful tool for monitoring fluid leakage activated by slow deformation on low permeable shale faults, with applications for sealing integrity of caprocks.

De Barros, Louis (ORCID:0000000255419162)↗

Behavior of Tidally Triggered Earthquakes Depends on Fluid Conditions

Seismicity at The Geysers geothermal field and in Oklahoma is heavily influenced by industrial activities related to energy production, though the mechanism in which earthquakes are induced or triggered is different. At The Geysers, much of the seismicity is linked to thermoelastic stresses caused by injecting cold water into hot rocks, whereas in Oklahoma, the seismicity is linked to a reduction of confining stress on faults due to increasing pore pressure resulting from wastewater injections. Here, in this study, we show that these contrasting conditions are also evident in tidally triggered earthquakes. At The Geysers, earthquakes preferentially occur during maximum extensional stress, which does not occur at the same time as maximum shear stress on optimally oriented faults in the regional stress field. In Oklahoma, earthquakes preferentially occur during maximum shear stress on optimally oriented faults rather than maximum extensional stress. The magnitude of tidal extensional stress is naturally much greater than tidal shear stress. However, in a fluid-saturated environment, pore pressure responds to changes in volume, which can counteract or reduce the effect of the applied stress. The difference in behavior at these two sites is indicative of the level of coupling between applied stress and pore pressure, corresponding to unsaturated conditions at The Geysers and high pore pressure in Oklahoma.

58 GEOSCIENCES↗

Aseismic Motions Drive a Sparse Seismicity During Fluid Injections Into a Fractured Zone in a Carbonate Reservoir

An increase in fluid pressure in faults can trigger seismicity and large aseismic motions. Understanding how fluid and faults interact is an essential goal for seismic hazard and reservoir monitoring, but this key relation remains unclear. We developed an in situ experiment of fluid injections at a 10 meter scale. Water was injected at high pressure in different geological structures inside a fault damaged zone, in limestone at 280 m depth in the Low Noise Underground Laboratory (France). Induced seismicity, as well as strains, pressure, and flow rate, was continuously monitored during the injections. Although nonreversible deformations related to fracture reactivations were observed for all injections, only a few tests generated seismicity. Events are characterized by a 0.5-to-4 kHz content and a small magnitude (approximately -3.5). They are located within 1.5 m accuracy between 1 and 12 m from the injections. Comparing strain measurements and seismicity shows that more than 96% of the deformation is aseismic. The seismic moment is also small compared to the one expected from the injected volume. Moreover, a dual seismic behavior is observed as (1) the spatiotemporal distribution of some cluster of events is clearly independent from the fluid diffusion (2) while a diffusion-type pattern can be observed for some others clusters. Furthermore, the seismicity might therefore appear as an indirect effect to the fluid pressure, driven by aseismic motion and related stress perturbation transferred through failure.

58 GEOSCIENCES↗

Application of Model-based Prognostics to a Pneumatic Valves Testbed

Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

prediction↗

Top-Off Safety Analysis for NSLS-II

Top-off injection will be adopted in NSLS-II. To ensure no injected beam can pass into experimental beamlines with open photon shutters during top-off injection, simulation studies for possible machine fault scenarios are required. We compare two available simulation methods, backward (H. Nishimura-LBL) and forward tracking (A. Terebilo-SLAC). We also discuss the tracking settings, fault scenarios, apertures and interlocks considered in the analysis.

43 PARTICLE ACCELERATORS↗

Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid Fault

This paper proposes an adaptive hierarchical voltage control scheme of a doubly-fed induction generator (DFIG)-based wind power plant (WPP) that can secure more reserve of reactive power (Q) in the WPP against a grid fault. To achieve this, each DFIG controller employs an adaptive reactive power to voltage (Q-V) characteristic. The proposed adaptive Q-V characteristic is temporally modified depending on the available Q capability of a DFIG; it is dependent on the distance from a DFIG to the point of common coupling (PCC). The proposed characteristic secures more Q reserve in the WPP than the fixed one. Furthermore, it allows DFIGs to promptly inject up to the Q limit, thereby improving the PCC voltage support. To avert an overvoltage after the fault clearance, washout filters are implemented in the WPP and DFIG controllers; they can prevent a surplus Q injection after the fault clearance by eliminating the accumulated values in the proportional-integral controllers of both controllers during the fault. Test results demonstrate that the scheme can improve the voltage support capability during the fault and suppress transient overvoltage after the fault clearance under scenarios of various system and fault conditions; therefore, it helps ensure grid resilience by supporting the voltage stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ChemoMechanical Controls on Induced Seismicity

In recent years, seismicity rates in the US have dramatically risen due to increased activity in onshore oil and gas production. This project attempts to tie observations about induced seismicity to dehydration reactions in laumontite, a common mineral found in fault gouge in crystalline basement formations. It is the hypothesis of this study that in addition to pressurerelated changes in the in situ stress state, the injection of wastewater pushes new fluids into crystalline fault fracture networks that are not in chemical equilibrium with the mineral assemblages, particularly laumontite in fault gouge. Experiments were conducted under hydrothermal conditions where samples of laumontite were exposed to NaC1 brines at different pH values. After exposure to different fluid chemistries for 8 weeks at 90° C, we did not observe substantial alteration of laumontite. In hydrostatic compaction experiments, all samples deformed similarly in the presence of different fluids. Pore pressure decreases were observed at the start of a 1 week hold at 85° C in a 1M NaC1 pH 3 solution, suggesting that acidic fluids might stabilize pore pressures in basement fault networks. Friction experiments on laumontite and kaolinite powders showed both materials have similar coefficients of friction. Mixtures with partial kaolinite content showed a slight decrease in the coefficient of friction, which could be sufficient to trigger slip on critically stressed basement faults.

58 GEOSCIENCES↗

Fault slip controlled by stress path and fluid pressurization rate

Abstract The practice of injecting fluids into the crust is linked to regional increases in seismicity. Increasing fluid pressure along preexisting faults is believed to enhance seismicity rates by reducing the shear stress required for slip, but the processes that cause faults to slip under conditions of fluid pressurization are poorly constrained. We use experimental rock deformation to investigate the controls of fluid pressurization and pressurization rates on fault slip style. We show that pore fluid pressurization is less effective that mechanical changes in fault normal stress at initiating accelerated slip events. Fluid pressurization enhances the total slip, slip velocity, and shear stress drop of events initiated by mechanical changes in normal stress, and these parameters are correlated with pressurization rate, but not the magnitude of fluid pressure. This result is consistent with field‐scale observations and indicates that processes active at the pore network scale affect induced seismicity.

French, Melodie E.↗

Thermal and capillary effects on the caprock mechanical stability at In Salah, Algeria

Thermo-mechanical effects are important in geologic carbon storage because CO 2 will generally reach the storage formation colder than the rock, inducing thermal stresses. Capillary functions, i.e., retention and relative permeability curves, control the CO 2 plume shape, which may affect overpressure and thus, caprock stability. To analyze these thermal and capillary effects, we numerically solve non-isothermal injection of CO 2 in deformable porous media considering the In Salah, Algeria, CO 2 storage site. Here, we find that changes in the capillary functions have a negligible effect on overpressure and thus, caprock stability is not affected by capillary effects. But, we show that for the strike slip stress regime prevalent at In Salah, stability decreases in the lowest parts of the caprock during injection due to cooling-induced thermal stresses. Simulations show that shear slip along pre-existing fractures may take place in the cooled region, whereas tensile failure is less likely to occur. Indeed, only the injection zone and the lowest tens of meters of the 900-m-thick caprock at In Salah might be affected by cooling effects, which would thus not jeopardize the overall sealing capacity of the caprock. Furthermore, faults are likely to remain stable far away from the injection well because outside the cooled region the injection-induced stress changes are not sufficient to exceed the anticipated shear strength of minor faults. Nonetheless, we recommend that thermal effects should be considered in the site characterization and injection design of future CO 2 injection sites to assess caprock stability and guarantee a permanent CO 2 storage.

54 ENVIRONMENTAL SCIENCES↗