Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAMMABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

ASSESSMENT OF THE POTENTIAL FOR HYDROGEN GENERATION DURING DEACTIVATION AND DECOMMISSIONING OF REACTOR VESSELS AT THE SAVANNAH RIVER SITE

The R- and P-reactor vessels at the Savannah River Site (SRS) are being prepared for deactivation and decommissioning (D&D). D&D activities will consist primarily of physically isolating and stabilizing the reactor vessel by filling it with a grout material. The reactor vessels contain aluminum alloy materials, which pose a concern in that aluminum corrodes rapidly when it comes in contact with the alkaline grout. A product of the corrosion reaction is hydrogen gas and therefore potential flammability issues were assessed. A model was developed to calculate the hydrogen generation rate as the reactor is being filled with the grout material. Three options existed for the type of grout material for D&D of the reactor vessels. The grout formulation options included ceramicrete (pH 6-8), a calcium aluminate sulfate (CAS) based cement (pH 10), or Portland cement grout (pH 12.4). Corrosion data for aluminum in concrete were utilized as input for the model. The calculations considered such factors as the surface area of the aluminum components, the open cross-sectional area of the reactor vessel, the rate at which the grout is added to the reactor vessel, and temperature. Given the hydrogen generation rate, the hydrogen concentration in the vapor space of the reactor vessel above the grout was calculated. This concentration was compared to the lower flammability limit for hydrogen. The assessment concluded that either ceramicrete or the CAS grout may be used to safely grout the P-reactor vessel. The risk of accumulation of a flammable mixture of hydrogen between the grout-air interface and the top of the reactor is very low. Portland cement grout, on the other hand, for the same range of process parameters did not provide a margin of safety against the accumulation of flammable gas in the reactor vessel during grouting operations in the P-reactor vessel. Therefore, it was recommended that this grout not be utilized for this task. On the other hand, the R-reactor vessel contained significantly less aluminum surface area that the P-reactor vessel based on current facility process knowledge, surface observations, and drawings. Therefore, a Portland cement grout may be considered for grouting operations as well as the other grout formulations.

08 HYDROGEN↗

Impact of scaling on the nitric-glycolic acid flowsheet

Savannah River Remediation (SRR) is considering using glycolic acid as a replacement for formic acid in Sludge Receipt and Adjustment Tank (SRAT) processing in the Defense Waste Processing Facility (DWPF). Catalytic decomposition of formic acid is responsible for the generation of hydrogen, a potentially flammable gas, during processing. To prevent the formation of a flammable mixture in the offgas, an air purge is used to dilute the hydrogen concentration below the 60% of the Composite Lower Flammability Limit (CLFL). The offgas is continuously monitored for hydrogen using Gas Chromatographs (GCs). Since formic acid is much more volatile and toxic than glycolic acid, a formic acid spill would lead to the release of much larger quantities to the environment. Switching from formic acid to glycolic acid is expected to eliminate the hydrogen flammability hazard leading to lower air purges, thus downgrading of Safety Significant GCs to Process Support GCs, and minimizing the consequence of a glycolic acid tank leak in DWPF. Overall this leads to a reduction in process operation costs and an increase in safety margin. Experiments were completed at three different scales to demonstrate that the nitric-glycolic acid flowsheet scales from the 4-L lab scale to the 22-L bench scale and 220-L engineering scale. Ten process demonstrations of the sludge-only flowsheet for SRAT and Slurry Mix Evaporator (SME) cycles were performed using Sludge Batch 8 (SB8)-Tank 40 simulant. No Actinide Removal Process (ARP) product or strip effluent was added during the runs. Six experiments were completed at the 4-L scale, two experiments were completed at the 22-L scale, and two experiments were completed at the 220-L scale. Experiments completed at the 4-L scale (100 and 110% acid stoichiometry) were repeated at the 22-L and 220-L scale for scale comparisons.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Current State of Knowledge for Thermolysis of Organics within SRS Waste Forming Volatile Organic Compounds (VOCs)

The 2017 report Flammable Gas Generation Mechanisms for High Level Liquid Waste Facilities , X-ESRG- 00062 Rev. 1, assessing mechanisms for flammable gas generation acknowledged the presence of flammable organics, concluding that available data indicated their concentrations pose a minor contribution (e.g., <5%) to the composite lower flammable limit. Savannah River Remediation (SRR) chartered the Savannah River National Laboratory (SRNL) to perform a more detailed assessment of available and emerging data to assess the current state of knowledge for formation of Volatile Organic Compounds (VOCs) from thermolysis of organics in Savannah River Site (SRS) caustic tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Depowering of Batteries to Reduce Cost of Ownership

(1) Executive Summary: End of life batteries (EOLBs) present a cost and safety liability for their owners and stakeholders. This is due flammability, energy, and power with EOLBs. Current approaches include cumbersome, expensive packaging, specialized shipping, regulated storage, and they are responsible for over half of the cost of recycling. They all expensively and inadequately address symptoms. OnTo has developed and proven a simple way to resolve the problem systemically, through depowering of lithium-ion batteries (and most any battery other than lead). The low-cost process removes flammability, power, and energy in EOLBs through non-toxic chemical processing. The opportunity for commerce of inert scrap is at least $5 billion greater than the commerce in hazardous scrap, all made possible through OnTo’s technology for efficiency and safety. (2) Depowering Improves Safety and Decreases Cost of Battery Ownership: OnTo’s depowering technology will remove half of the cost of EOLB management and recycling. Without this technology, EOLB recycling will always be a liability. EOLB is hazardous due to inherent flammability of electrolyte and lithium. The shipping and commerce of EOLBs is costly and dangerous all along the chain of custody from owner, dealership/shop, shipper, second-life sorter, (shipper again), and finally to the destination facility recycler. OnTo’s depowering service renders inert most any EOLB packs, modules, and cells. The technology uses a brief, non-toxic treatment applicable to most any chemistry. The industry needs a safe, simple, modular, and inexpensive method to render EOLBs as inert scrap. OnTo’s deactivation system is scalable to the needs of any customer along the EOLB chain of custody. (3) Evidence of Successful Depowering: Untreated batteries will catch fire and explode under abuse conditions such as heat or crush. Slide 2 below shows that untreated batteries will blow-up and expel their internal components with heating, after OnTo’s depowering treatment, the same battery is inert with the same heat treatment (Fig. 7 in the slide). Depowering also removes electrolyte reactivity, eliminating the production of HF and other toxins (Fig 6. in the slide) The depowering process is applicable to large, 26 Ah cells. Fig. 5 in the slide shows the removal of all the electrolyte from whole cells. Removal of flammable material from an EOLB contributes to the inert behavior. OnTo developed this technology through a project supported by the US Department of Energy EERE program, with partners including Seattle King County Metro Transit. While OnTo has generated evidence of successful depowering of batteries, in 2020, a follow-on voucher opportunity for third party analysis of depowered cells and materials was approved through CalTestBed. The expertise of the battery and materials research groups at Lawrence Berkeley National Laboratory will characterize these depowered cells to provide better understanding of the materials level changes in depowering. (4) Pilot Plant for Depowering EOLBs: Making the spoke work in hub-and-spoke While other companies are marketing the hub-and-spoke approach for recycling EOLBs, they rely on dangerous, expensive shredding methods with flimsy IP protection. OnTo offers the only patented, proven ability to depower EOLBs from most any chemistry – at half of the capital cost required for shredding, while eliminating the liability, danger, and waste streams inherent with shredding. The proposed commercial pilot facility is (5) OnTo Technology LLC Company: OnTo develops advanced battery recycling innovations that produce manufacturing quality electrode materials from recycled batteries. Their patented Cathode-healing™ and Deactivation/Depowering processes improve safety and reduce the cost of recycling. OnTo’s breakthrough technologies produce advanced materials for manufacturing batteries useful in applications from portable power to electric vehicles. Contact: Steve Sloop OnTo Technology LLC, 63221 Service Road, STE F, Bend, OR 97703, ssloop@onto-technology.com , 541-389-7897

deactivation↗

Aircraft Engine Sump Fire Mitigation, Phase 2

The effect of changes in the input parameters (air leakage flow rate and temperature and lubricating oil inlet flow rate and temperature) over a specified range on the flammability conditions within an aircraft engine bearing sump was investigated. An analytical study was performed to determine the effect of various parameters on the generation rate of oil vapor from oil droplets in a hot air stream flowing in a cylindrical tube. The ignition of the vapor-air mixture by an ignition source was considered. The experimental investigation demonstrated that fires would be ignited by a spark ignitor over the full range of air and oil flow rates and air temperatures evaluated. However, no fires could be ignited when the oil inlet temperature was maintained below 41.7 K (290 F). The severity of the fires ignited were found to be directly proportional to the hot air flow rate. Reasonably good correlation was found between the mixture temperature in the sump at the ignitor location and the flammability limits as defined by flammability theory; thus a fairly reliable experimental method of determining flammable conditions within a sump was demonstrated. The computerized mathematical model shows that oil droplet size and air temperature have the greatest influence on the generation rate of oil vapor.

Rosenlieb, J. W.↗

Thermochemical characterization of some thermally stable thermoplastic and thermoset polymers

The thermochemical and flammability properties of some thermally stable polymers considered for use in aircraft interiors are described. The properties studied include: (1) thermomechanical properties such as glass transition and melt temperature; (2) dynamic thermogravimetric analysis in anaerobic environment; (3) flammability properties such as oxygen index, flame spread, and smoke evolution; and (4) selected physical properties. The thermoplastic polymers evaluated include polyphenylene sulfide, polyaryl sulfone, 9,9-bis(4-hydroxyphenyl)-fluorene polycarbonate-poly(dimethylsiloxane) and polyether sulfone. The thermoset polymers evaluated include epoxy, bismaleimide, a modified phenolic, and polyaromatic melamine resin. These resins were primarily used in the fabrication of glass-reinforced prepregs for the construction of experimental panels. Test results and relative rankings of some of the flammability parameters are presented, and the relationship of the molecular structure, char yield, and flammability properties of these polymers are discussed.

Kourtides, D. A.↗

Fire blocking systems for aircraft seat cushions

A configuration and method for reducing the flammability of bodies of organic materials that thermally decompose to give flammable gases comprises covering the body with a flexible matrix that catalytically cracks the flammable gases to less flammable species. Optionally, the matrix is covered with a gas impermeable outer layer. In a preferred embodiment, the invention takes the form of an aircraft seat in which the body is a poly(urethane) seat cushion, the matrix is an aramid fabric or felt and the outer layer is an aluminum film.

Parker, J. A.↗

Effect of gravity on halogenated hydrocarbon flame retardant effectiveness

Flammability limits, burning velocities, and minimum ignition energies under initially quiescent conditions were measured for stoichiometric and fuel-lean methane-, ethane-, and propane-air mixtures containing varying concentrations of Halon 1301. The characteristics of near-limit flames were strongly affected by fuel type but not Halon concentration. The conclusions were that the mechanism of the flammability limits was affected by fuel type but not Halon concentration, that the zero-g flammability limit is probably related to a stability criterion which is affected mostly by the molecular diffusion characteristics of the reactant gases and is mostly independent of chemical kinetics, and that the one-g upward flammability and ignition limits provide adequate criteria for safety at one-g and zero-g for both uninhibited and inhibited mixtures.

Ronney, P. D.↗

Effect of gravity on halogenated hydrocarbon flame retardant effectiveness

Flammability limits, burning velocities, and minimum ignition energies under initially quiescent conditions were measured for stoichiometric and fuel-lean methane-, ethane-, and propane-air mixtures containing varying concentrations of Halon 1301. The characteristics of near-limit flames were strongly affected by fuel type but not Halon concentration. The conclusions were that the mechanism of the flammability limits was affected by fuel type but not Halon concentration, that the zero-g flammability limit is probably related to a stability criterion which is affected mostly by the molecular diffusion characteristics of the reactant gases and is mostly independent of chemical kinetics, and that the one-g upward flammability and ignition limits provide adequate criteria for safety at one-g and zero-g for both uninhibited and inhibited mixtures.

Ronney, P. D.↗

Catalytic Layer Makes Aircraft Seats More Fire Retardant

Specially constructed cushion retards fires in aircraft seats through action of catalytic matrix that cracks flammable gaseous decomposition products to less flammable species. Improved cushion contributes substantially to fire safety without adding significantly to weight or to manufacturing cost. In this fire-blocking covering for an aircraft seat cushion, flammable pyrolysis products cracked to less flammable species by catalytic layer covering foam core of cushion. Aluminum foil holds in pyrolysis vapors to promote catalysis and prevent spread of fire by ignition of released vapors.

Parker, John A.↗

Extinguishment of a Diffusion Flame Over a PMMA Cylinder by Depressurization in Low-Gravity

The behavior of flames in low-speed flows in low-gravity is relevant to spacecraft fire safety. Previous work has shown that flames in the presence of low-speed forced flows in low-gravity may be more flammable than in a forced flow of the same magnitude in normal gravity. Additionally, fire suppression plans for the International Space Station include the use of venting (depressurization) as an emergency option for extinguishing fires. This procedure would induce flows in the affected compartment that could temporarily intensify the fire, as was observed in flammability tests of solids conducted on board Skylab. Despite a general Understanding, current knowledge of the combined effects of reduced pressure and forced flow on a burning solid in low-gravity is inadequate for the design of a venting extinguishment system. Previous studies in low-g have examined flammability limits for thermally thin solids. However, there are differences when burning thick materials because the interior solid-phase temperature continuously changes, which affects the percentage of gas-phase heat feedback to the solid-phase. Changes in the heat feedback to the solid-phase can affect the flammability characteristics of the material. In the current work, the extinction of a diffusion flame burning over PMMA (polymethyl methacrylate) cylinders during depressurization with a low-speed cross flow was examined experimentally and via numerical simulations.

Goldmeer, Jeffrey S.↗

Experimental Measurements of Two-dimensional Planar Propagating Edge Flames

The study of edge flames has received increased attention in recent years. This work reports the results of a recent study into two-dimensional, planar, propagating edge flames that are remote from solid surfaces (called here, free-layer flames, as opposed to layered flames along floors or ceilings). They represent an ideal case of a flame propagating down a flammable plume, or through a flammable layer in microgravity. The results were generated using a new apparatus in which a thin stream of gaseous fuel is injected into a low-speed laminar wind tunnel thereby forming a flammable layer along the centerline. An airfoil-shaped fuel dispenser downstream of the duct inlet issues ethane from a slot in the trailing edge. The air and ethane mix due to mass diffusion while flowing up towards the duct exit, forming a flammable layer with a steep lateral fuel concentration gradient and smaller axial fuel concentration gradient. We characterized the flow and fuel concentration fields in the duct using hot wire anemometer scans, flow visualization using smoke traces, and non-reacting, numerical modeling using COSMOSFloWorks. In the experiment, a hot wire near the exit ignites the ethane air layer, with the flame propagating downwards towards the fuel source. Reported here are tests with the air inlet velocity of 25 cm/s and ethane flows of 967-1299 sccm, which gave conditions ranging from lean to rich along the centerline. In these conditions the flame spreads at a constant rate faster than the laminar burning rate for a premixed ethane air mixture. The flame spread rate increases with increasing transverse fuel gradient (obtained by increasing the fuel flow rate), but appears to reach a maximum. The flow field shows little effect due to the flame approach near the igniter, but shows significant effect, including flow reversal, well ahead of the flame as it approaches the airfoil fuel source.

Villa-Gonzalez, Marcos↗

Piloted Ignition Delay of PMMA in Space Exploration Atmospheres

In order to reduce the risk of decompression sickness associated with extravehicular activity (EVA), NASA is designing the next generation of exploration vehicles and habitats with a different cabin environment than used previously. The proposed environment uses a total cabin pressure of 52.7 to 58.6 kPa with an oxygen concentration of 30 to 34% by volume and was chosen with material flammability in mind. Because materials may burn differently under these conditions and there is little information on how this new environment affects the flammability of the materials onboard, it is important to conduct material flammability experiments at the intended exploration atmosphere. One method to evaluate material flammability is by its ease of ignition. To this end, piloted ignition delay tests were conducted in the Forced Ignition and Spread Test (FIST) apparatus subject to this new environment. In these tests, polymethylmethacylate (PMMA) was exposed to a range of oxidizer flow velocities and externally applied heat fluxes. Tests were conducted for a baseline case of normal pressure and oxygen concentration, low pressure (58.6 kPa) with normal oxygen (21%), and low pressure with 32% oxygen concentration conditions to determine the individual effect of pressure and the combined effect of pressure and oxygen concentration on the ignition delay. It was found that reducing the pressure while keeping the oxygen concentration at 21% reduced the ignition time by 17% on average. Increasing the oxygen concentration at low pressures reduced the ignition time by an additional 10%. It was also noted that the critical heat flux for ignition decreases at exploration atmospheres. These results show that tests conducted in standard atmospheric conditions will underpredict the ignition of materials intended for use on spacecraft and that, at these conditions, materials are more susceptible to ignition than at current spacecraft atmospheres.

McAllister, Sara↗

Additively Manufactured Metals in Oxygen Systems Project

Metals produced by additive manufacturing methods, such as Powder Bed Fusion Technology, are now mature enough to be considered for qualification in human spaceflight oxygen systems. The mechanical properties of metals produced through AM processes are being systematically studied. However, it is unknown whether AM metals in oxygen applications may present an increased risk of flammability or ignition as compared to wrought metals of the same metallurgical composition due to increased porosity. Per NASA-STD-6001B materials to be used in oxygen system applications shall be based on flammability and combustion test data, followed by a flammability assessment. Without systematic flammability and ignition testing in oxygen there is no credible method for NASA to accurately evaluate the risk of using AM metals in oxygen systems.

Tylka, Jonathan↗

Solid Fuel Ignition and Extinction (SoFIE) Project on ISS

The Solid Fuel Ignition and Extinction (SoFIE) project studies ignition and flammability of solid spacecraft materials (fuels) in practical geometries and realistic atmospheric conditions. It is an experiment insert designed for use within the existing Combustion Integrated Rack (CIR). The CIR chamber provides a level of containment and permits testing at variable oxygen concentrations and pressures representative of current and planned NASA Space Exploration Atmospheres. The applications of SoFIE include: (1) Determining safer selection of cabin materials and validating NASA materials flammability selection using 1-g test protocols for low-gravity fires, (2) Improving understanding of early fire growth behavior, (3) Validating material flammability numerical models, (4) Determining optimal suppression techniques for burning materials by diluents, flow reduction, and venting, (5) Obtaining burning behavior of actual engineering materials planned for spacecraft, (6) Developing corresponding models of microgravity flame spread, flammability, and extinction, and use the results to improve normal gravity combustion models for terrestrial applications. The hardware permits a wide range of solid-material combustion and fire suppression studies. It supports multiple investigations using common infrastructure including sample holders, flow control, test sections, external radiant heaters, igniters, and diagnostics. SoFIE has been developed to meet the requirements of five unique investigations. It is currently being built and slated to begin operations on the ISS in July 2021. Given the general capabilities of the hardware insert, it is intended to be used as a facility for future researchers who can propose to NASA for related solid combustion studies.

Ferkul, Paul↗

Fire-Resistant Textile Development for Exploration Vehicles With Enriched-Oxygen Cabin Environments

Material selection is a key part of the National Aeronautics and Space Administration (NASA) spacecraft fire safety management plan. Non-flammable textiles are necessary to ensure large-scale flame propagation events do not occur inside a spacecraft. An increased use of textiles and other softgood material is crucial to the pursuit of exploration spaceflight to reduce mass and volume. Exploration spaceflight missions benefit from enriched oxygen cabin environments (>21% O2) by allowing a reduced prebreathe protocol before Extravehicular Activity (EVA). However, materials become exponentially more flammable the higher the O2 levels become. Recent testing within the agency has revealed the lack of commercial-off-the-shelf (COTS) materials that can meet safety requirements in oxygen-enriched environments. Most of the fibers and textiles developed during Apollo (100% O2 cabin environment) and Skylab (>70% O2 cabin environment) are no longer commercially available due to those Programs ending and the discontinuation of raw materials or closure of the original manufacturers. As NASA returns to higher oxygen concentrations inside spacecraft, non-flammable textile development efforts have begun to meet the agency’s needs. This paper discusses those efforts including overall fire safety approach, priorities, interactions with industry, flammability testing and expected challenges.

Karim Aly↗

Control Decision and Control Development of Hanford Tank Farms First Two ISA-84 Safety Instrumented Systems - 17370

Hanford's 242-A Evaporator has had the mission of reducing waste volume in the Hanford Tank Farms since the late 1970's. Until 2014, the Documented Safety Analysis for the 242-A facility considered protection and controls of the collocated worker (workers outside the facility) and the public. In 2010, Tank Farms Nuclear Safety engineers initiated a significant revision of the Documented Safety Analysis to implement DOE-STD-3009, Change Notice 3, which requires the protection of the facility worker in addition to the collocated worker and public. Through the use of an extensive process hazards analysis performed on the facility, it was concluded that it was essential to control conditions in the primary evaporation vessel (C-A-1) such that flammable gasses could not build up to the Lower Flammability Limit, and that another control was necessary to ensure that the C-A-1 vessel could not overflow. Early control decision meetings held during the development of the Documented Safety Analysis revision yielded no simple solution to the protection of workers from a flammable gas deflagration. Controls selected for the waste overflow accident were all mitigative in nature (i.e. the detection of a waste overflow after it already happened). Engineering could not replace the mitigative controls with preventive controls without attempting to credit some of the existing facility interlocks associated with the C-A-1 vessel operations. Software and hard-wired interlocks had been used at the facility to prevent overheating of the waste and overfilling of the C-A-1 vessel. These interlocks were considered useful to the prevention of the flammable gas deflagration and vessel overfilling accidents, but lacked the pedigree and reliability necessary to credit the interlocks as safety significant. It was at this stage of the Documented Safety Analysis control decision and control development that engineering became aware of the DOE's acceptance of the ISA-84 instrumented system standard. It became apparent that the ideal solution was not to attempt to credit existing interlock systems, but to develop a new system of 'safety interlocks' to the ISA-84 standard. A meeting was held with upper management of both engineering and operations to propose the use of safety instrumented systems at the 242-A facility. URS Corporation (now AECOM), who had recently supported the Savanah River site in developing ISA-84 controls, was consulted to support the development of two new instrumented systems for the 242-A facility. In addition to the use of the newly adopted ISA-84 standard, the failure modes and effect analysis process was implemented in a very effective manner to support the development of the new safety instrumented systems. Through a brand new methodology, and through a very dedicated and hard-working engineering, projects, and operations team, the new controls were designed, built, tested, and commissioned. At this time, five successful waste reduction campaigns have been performed at the facility with the new safety instrumented systems. During these waste processing campaigns, trips and spurious trips of the SIS have occurred - all of which acted properly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transporting Non-Compliant TRU Wastes in the OPTIMUS{sup TM} Packages - 20493

The OPTIMUS{sup TM} product line of packages was developed with the purpose of providing a versatile and modular packaging option for shipping problematic wastes and fissile material contents. The product line includes a high-activity design in the OPTIMUS-H and a low activity design in the OPTIMUS-L. The two variants utilize a singular containment vessel design, that is enclosed in different protective components that offer different levels of shielding along with thermal and impact protection. The thick shielding provided by the OPTIMUS-H packaging allows for higher activity contents than the OPTIMUS-L to be transported. But the lightweight design of the OPTIMUS-L packaging allows for more packages to be transported in a single shipment. The containment vessel design shared between the two packages provides leak-tight containment of all radioactive contents along with the capabilities to easily leak test and the option to inert and backfill the contents, as necessary, prior to each shipment of the package. Together the OPTIMUS package designs offer significant flexibility and are capable of handling a wide variety of waste materials and other radioactive contents. One of the primary contents covered in the initial design effort for these packages is TRU waste contents beyond the standard waste materials that are compliant with the WIPP Waste Acceptance Criteria. More specifically, the initial content of interest is TRU Waste drums containing sealed containers with potentially flammable gases. While there are multiple other packaging options available for transporting standard WIPP compliant TRU wastes, the goal of the OPTIMUS packages is to offer a superior option for transporting both standard TRU wastes as well as the more problematic non-compliant wastes, among other contents. The non-compliant TRU waste contents explicitly included for the OPTIMUS packages are standard aerosol cans and DOT 3E lecture bottles. However, the methods applied for the package containment can be easily adjusted to cover other sealed container types with potentially flammable gases. The primary challenges with including these items are both the obvious issue of potential for flammable gases (e.g. aerosol propellants) in the package, but also the uncertainty in the exact state of the contents. Because these desired contents are waste materials, the characterization of the materials present in the waste may include some uncertainties. For example, though it may be known that there are one or more aerosol cans in a TRU waste drum, it may not be known if this can is full, spent, or anywhere in between. Also there may be equal uncertainty in the contents of the aerosol can, specifically in the potentially flammable propellant remaining in the can. To include these types of non-compliant items as acceptable contents for the package, the methods utilized in the safety analyses of the OPTIMUS packages must consider all of the uncertainties in the characterization of the waste. The methods utilized cover a range of concerns with transporting contents of this nature including pressure buildup, gas generation, and gaseous combustion for demonstrating the containment of the package. The ability to transport these problematic contents in the OPTIMUS packages gives TRU waste generating sites the option to relocate these drums to an offsite location where the non-compliant items can be properly managed through removal or destruction. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗