Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Evaluation System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A flight test of laminar flow control leading-edge systems

NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

Fischer, M. C.↗

A flight test of laminar flow control leading-edge systems

NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

Fischer, M. C.↗

Implementation of Recommendations from the One System Comparative Evaluation of the Hanford Tank Farms and Waste Treatment Plant Safety Bases

A Comparative Evaluation was conducted for One System Integrated Project Team to compare the safety bases for the Hanford Waste Treatment and Immobilization Plant Project (WTP) and Tank Operations Contract (TOC) (i.e., Tank Farms) by an Expert Review Team. The evaluation had an overarching purpose to facilitate effective integration between WTP and TOC safety bases. It was to provide One System management with an objective evaluation of identified differences in safety basis process requirements, guidance, direction, procedures, and products (including safety controls, key safety basis inputs and assumptions, and consequence calculation methodologies) between WTP and TOC. The evaluation identified 25 recommendations (Opportunities for Integration). The resolution of these recommendations resulted in 16 implementation plans. The completion of these implementation plans will help ensure consistent safety bases for WTP and TOC along with consistent safety basis processes. procedures, and analyses. and should increase the likelihood of a successful startup of the WTP. This early integration will result in long-term cost savings and significant operational improvements. In addition, the implementation plans lead to the development of eight new safety analysis methodologies that can be used at other U.S. Department of Energy (US DOE) complex sites where URS Corporation is involved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Multi-attribute Utility Functions in Evaluating Security Systems

In analyzing security systems, we are concerned with protecting a building or facility from an attack by an adversary. Typically, we address the possibility that an adversary could enter a building and cause damage resulting in an immediate loss of life, or at least substantial disruption in the operations of the facility. In response to this setting, we implement security systems including devices, procedures, and facility upgrades designed to (a) prevent the adversary from entering, (b) detect and neutralize him if he does enter, and (c) harden the facility to minimize damage if an attack is carried out successfully. Although we have cast this in terms of physical protection of a building, the same general approach can be applied to non-physical attacks such as cyber attacks on a computer system. A rigorous analytic process is valuable for quantitatively evaluating an existing system, identifying its weaknesses, and proposing useful upgrades. As such, in this paper we describe an approach to assess the degree of overall protection provided by security measures. Our approach evaluates the effectiveness of the individual components of the system, describes how the components work together, and finally assesses the degree of overall protection achieved. This model can then be used to quantify the amount of protection provided by existing security measures, as well as to address proposed upgrades to the system and help identify a robust and cost effective set of improvements. Within the model, we use multiattribute utility functions to perform the overall evaluations of the system.

99 GENERAL AND MISCELLANEOUS↗

A system for evaluating Ada implementations using synthesized benchmarks

A system is described that allows project designers to evaluate the suitability of an Ada implementation for a particular application using tailored benchmarks. Specification of the load that an application is expected to generate is written in an Ada-like notation. An Ada program is then synthesized that generates the specified load. Studies of the way in which performance varies with various parameters of the application can be performed by the system automatically.

Knight, John C.↗

Methods and systems for evaluating and improving distribution-grid observability

This document describes systems and techniques for evaluating and improving distribution-grid observability. These systems and techniques allow engineers to quantify the observability of a distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters), from a system model. Distribution engineers can also identify islands of observability where operating parameters, including voltages, currents, and power flows, can be determined from available sensor readings. By exclusion, distribution engineers can similarly identify areas of the distribution grid with observability deficiencies that may require additional instrumentation to maintain proper operation. Distribution engineers, using an iterative or automated process, can determine the observability of the system model with new or relocated sensors to generate a sensor allocation plan. The sensor allocation plan can indicate the number and location of sensors to either maximize observability for a fixed sensor cost or minimize sensor cost for predetermined observability.

Reiman, Anthony P.↗

Instrumentation for Evaluating PV System Performance Losses from Snow

When designing a photovoltaic (PV) system for northern climates, the prospective installation should be evaluated with respect to the potentially detrimental effects of snow preventing solar radiation from reaching the PV cells. The extent to which snow impacts performance is difficult to determine because snow events also increase the uncertainty of the solar radiation measurement, and the presence of snow needs to be distinguished from other events that can affect performance. This paper describes two instruments useful for evaluating PV system performance losses from the presence of snow: (1) a pyranometer with a heater to prevent buildup of ice and snow, and (2) a digital camera for remote retrieval of images to determine the presence of snow on the PV array.

14 SOLAR ENERGY↗

Oxidation screening at 1204 C /2200 F/ of candidate alloys for the space shuttle thermal protection system.

Evaluation of the oxidation resistance of 15 alloys under some of the environmental conditions that might be encountered by the shuttle thermal protection system. The alloys included nickel-, iron-, and cobalt-base wrought alloys. Specimens were self-resistively heated to 1204 C (2200 F) in a 10-torr still-air environment for 100 thirty-minute cycles. Specimen weight, thickness, and microstructural changes were noted, and surface scales were identified by room-temperature X-ray diffraction. Based on these observations, the behavior of the alloys was evaluated in terms of overall amount of metal consumption due to oxide formation and relative tendency toward oxide spalling and scale vaporization.

Sanders, W. A.↗

Used Fuel Management System Architecture Evaluation, Fiscal Year 2012

In the 1990s the U.S. Department of Energy (DOE) completed a number of system analyses investigating consolidated interim storage as a part of the waste management solution. These analyses are “dated” and do not reflect the present situation regarding at-reactor used nuclear fuel (UNF) management, alternatives for away from reactor management of used nuclear fuel, and alternatives for the ultimate disposal of UNF. The Blue Ribbon Commission for America’s Nuclear Future and the Nuclear Waste Technical Review Board have also pointed out the need for such analyses. The Used Fuel Management System Architecture Evaluation effort provides the DOE and others with information regarding the various alternatives for managing UNF generated by the current fleet of light water reactors operating in the U.S. The objectives are to: • Provide quantitative information with respect to a broad range of UNF management alternatives and considerations • Develop an integrated approach to evaluating storage, transportation, and disposal options, with emphasis on flexibility • Evaluate impacts of storage choices on UNF storage, handling, and disposal options • Identify alternative strategies and evaluate with respect to cost and flexibility • Consider a broad range of factors including repository emplacement capability, thermal constraints, repackaging needs, storage and transportation alternatives, and impacts on utility operations. In Fiscal Year 2012 system-level analyses of the overall interface between at-reactor, consolidated storage, and ultimate disposition along with the development of supporting logistic simulation tools were initiated. The objective of the Fiscal Year 2012 effort was two-fold: 1) develop methodologies, approaches, and tools (capability development), and 2) evaluate select UNF disposition scenarios (capability demonstration). The scenarios chosen for evaluation and the assumptions, inputs, and boundary conditions selected allowed for an initial set of analyses to gain insight regarding integrated system dynamics and an understanding of trends. This initial set of analyses also points to where additional system architecture analyses should focus.

Nutt, Mark↗

Electric Water Heaters for Transactive Systems: Model Evaluations and Performance Quantification

Electric water heaters (EWHs) are opportune appliances for implementing demand-side control. EWH models serve as a fundamental step toward accurately estimating EWH flexibility potential and designing proper control strategies. Existing studies have adapted numerous modeling approaches in evaluating the potential of EWHs for a variety of grid applications. This paper presents an analytical study that evaluates the performance of state-of-art EWH models in terms of accuracy and computational complexity for adaptation in evaluation studies for the transactive system. The work proposes a transactive control strategy that optimally utilizes the thermal inertia of EWHs for providing grid services. Here, the performance of the control strategy and the impact of modeling accuracy is evaluated for device-level and feeder-level use cases using the IEEE 123 node test distribution system appropriately populated with EWHs. The simulation results illustrate the effectiveness of the control strategy in reducing the feeder demand during peak period by 13% and also quantities the impact of using simplified modeling approaches for determining the potential of EWHs for providing grid services.

42 ENGINEERING↗

Standards for evaluating expert system tools

A brief survey of the literature and proposal for a standard methodology for evaluating expert system building tools are discribed. Criteria for expert systems environmental factors and expert systems tool features are also discussed.

Beach, Sharon S.↗

Overview of the Findings of the Extreme Environment Power Systems Standards Evaluation and Gap Analysis

This lightning talk gives an overview of the findings of the NASA funded Extreme Environment Power Systems Standards Evaluation and Gap Analysis. This document highlighted the gaps between terrestrial distribution system component standards and future lunar distribution system component standards. This shows that existing standards cannot be applied with small modifications for the lunar environment.

electrical power↗

Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

Source record↗