Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Arc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Ultraviolet sensing apparatus with mirror amplification

Systems, methods, and devices of the various embodiments may enable the detection and localization of power line corona discharges and/or electrical arcs by an unmanned aerial vehicle (UAV) including an ultraviolet (UV) sensor and a reflective parabolic dish. In various embodiments, the UV sensor may use the photoelectric effect to sense narrow-band UV photons in a Geiger-Mueller tube and circuit configuration. In various embodiments, the reflective parabolic dish may be fixed relative to the UV sensor and include a reflective concave surface. The reflective concave surface may be configured to reflect narrow-band UV photons toward the UV sensor.

Moore, Andrew J.↗

Computational Methods for Multi-Physics Simulation of Melting in Steelmaking

Iron and steel production accounts for approximately 8% of global carbon dioxide (CO) emissions. Pathways to decarbonize include replacing fossil fuels in iron ore reduction and electrifying other steelmaking processes. Iron pellets produced by hydrogen, called Hydrogen Direct Reduced Iron (HDRI), have property differences from those produced using conventional DRI processes. These differences may impact melting in electric arc furnaces (EAF) and other downstream processes. The physical properties of iron pellets vary significantly with temperature during heating, complicating predictions of their behavior. In this project, we seek to develop an integrated simulation, including the fluid flow and convective thermal transport around the pellet particle. We also examine conduction and phase changes within the particle as they impact the melting process. We use adaptive mesh refinement (AMR) to resolve both the changing size of the particle and the complex physics of the interaction between the pellet and the surrounding fluid. We base our simulations on the AMReX-incflo module, which allows large-scale Navier-Stokes simulation while resolving the changing particle size during melting. As we advance our numerical tools, we anticipate an improved understanding of the dynamics of HDRI melting, which will, in turn, accelerate the adoption of low-carbon technologies in the steelmaking industry.

AMReX↗

Thermal investigation of an electrical high-current arc with porous gas-cooled anode

The following guantities were measured on a high-intensity electric arc with tungsten cathode and transpiration-cooled graphite anode burning in argon: electric current and voltage, cooling gas flow rate (argon), surface temperature of the anode and of the anode holder, and temperature profile in three cross-sections of the arc are column. The last mentioned values were obtained from spectroscopic photographs. From the measured quantities, the following values were calculated: the heat flux into the anode surface, the heat loss of the anode by radiation and conduction, and the heat which was regeneratively transported by the cooling gas back into the arc space. Heat balances for the anode were also obtained. The anode losses (which are approximately 80% of the total arc power for free burning arcs) were reduced by transpiration cooling to 20%. The physical processes of the energy transfer from the arc to the anode are discussed qualitatively.

Eckert, E. R. G.↗

Double-ended metal halide arc discharge lamp with electrically isolated containment shroud

A double-ended arc discharge lamp includes a sealed, light-transmissive outer jacket, a light-transmissive shroud mounted within the outer jacket and directly supported by the outer jacket, and an arc discharge tube mounted within the shroud. The arc tube is typically a metal halide arc discharge tube. In a preferred embodiment, the shroud includes an outwardly flared portion at each end. The outwardly flared portions space the shroud from the outer jacket and support the shroud within the outer jacket. The outwardly flared portions of the shroud can be affixed to the outer jacket by fusing. The outer jacket can be provided with inwardly extending dimples for locating the shroud with respect to the outer jacket. In another embodiment, the outer jacket includes reduced diameter portions near each end which are attached to the shroud.

Muzeroll, Martin M.↗

Double-ended metal halide arc discharge lamp with electrically isolated containment shroud

A double-ended arc discharge lamp includes a sealed, light-transmissive outer jacket, a light-transmissive shroud mounted within the outer jacket and directly supported by the outer jacket, and an arc discharge tube mounted within the shroud. The arc tube is typically a metal halide arc discharge tube. In a preferred embodiment, the shroud includes an outwardly flared portion at each end. The outwardly flared portions space the shroud from the outer jacket and support the shroud within the outer jacket. The outwardly flared portions of the shroud can be affixed to the outer jacket by fusing. The outer jacket can be provided with inwardly extending dimples for locating the shroud with respect to the outer jacket. In another embodiment, the outer jacket includes reduced diameter portions near each end which are attached to the shroud.

Muzeroll, Martin M.↗

Rocket measurements within a polar cap arc - Plasma, particle, and electric circuit parameters

Results are presented from the Polar Ionospheric Irregularities Experiment (PIIE), conducted from Sondrestrom, Greenland, on March 15, 1985, designed for an investigation of processes which lead to the generation of small-scale (less than 1 km) ionospheric irregularities within polar-cap F-layer auroras. An instrumented rocket was launched into a polar cap F layer aurora to measure energetic electron flux, plasma, and electric circuit parameters of a sun-aligned arc, coordinated with simultaneous measurements from the Sondrestrom incoherent scatter radar and the AFGL Airborne Ionospheric Observatory. Results indicated the existence of two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability.

Weber, E. J.↗

Eddy intrusion of hot plasma into the polar cap and formation of polar-cap arcs

Plasma and electric field signatures of polar cap arcs in their formation region above 5000 km are examined. Signatures for active and for quiet magnetic conditions are presented, both indicating a virtual equivalence of plasma and electric field signatures between the polar and evening discrete arcs, although their optical configurations can be very different. It is proposed that the two types of arcs are indeed the same at active times except that the polar cap arcs occur at multiple convection reversal boundaries of plasmasheet plasmas which intrude into the normal polar cap in the form of multiple cellular eddies. A far-reaching consequence of this hypothesis is the unification of arc formation theory clarifying the distinct roles of arc formation parallel electric fields and of arc configuration and location. Optical and particle data which support this hypothesis are discussed.

Chiu, Y. T.↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

AE-C observations of electric fields around auroral arcs

Variations in the ion drift signatures observed by the Atmosphere Explorer-C satellite during passage through the auroral zone are discussed. Three mutually perpendicular components of ion drift velocity were derived, along with the ion concentrations and temperature. Electric field signatures detected in the vicinity of auroral arcs in the nighttime ionosphere are described, including the existence of auroral arcs both equatorward and poleward of the global convection reversal. It was also found that when electric field enhancements occur on one side of an auroral arc, particle precipitation is present on both sides, although the field-aligned potential drop associated with the accompanying particles is lower than that required for a discrete arc. Finally, it is noted that the region of the magnetosphere connected to discrete arcs has large and small areas in which adjacent flow regions are opposed to one another.

Heelis, R. A.↗

Making Conductive Polymers By Arc Tracking

Experimental technique for fabrication of electrically conductive polymeric filaments based on arc tracking, in which electrical arc creates conductive carbon track in material that initially was insulator. Electrically conductive polymeric structures made by arc tracking aligned along wire on which formed. Alignment particularly suited to high conductivity and desirable in materials intended for testing as candidate superconductors.

Daech, Alfred F.↗

Chatanika radar measurements of the electrical properties of auroral arcs

Ionospheric parameters measured in the presence of auroral arcs by the incoherent scatter Chatanika radar are used to define properties of the arcs. The radar broadcasts at 3-5 MW with a range resolution of 4.5 km along the radar line-of-sight, and has yielded auroral measurements on the variation of electron density, Hall and Pederson conductivity, horizontal electric fields, electrojet currents, precipitating electron energy flux, and the Joule heating rate. Elevation-scan techniques have been utilized to study the latitude and altitude variation of the ionospheric plasma parameters, and fixed-position scans allow determination of ionization conditions, including the electric fields and the acceleration of precipitating auroral electrons. Arcs in the diffuse aurora have been found to be local conductivity enhancements, while discrete arcs correspond to the boundary plasma sheet and have an asymmetric electric field pattern reduced on the northward side.

Vondrak, R. R.↗

Dry and wet arc track propagation resistance testing

The wet arc-propagation resistance test for wire insulation provides an assessment of the ability of an insulation to prevent damage in an electrical environment. Results of an arc-propagation test may vary slightly due to the method of arc initiation; therefore a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc by dripping salt water over pre-damaged wires which creates a conductive path between the wires. The power supply, test current, circuit resistances, and other variables are optimized for testing 20 guage wires. The use of other wire sizes may require modifications to the test variables. The dry arc-propagation resistance test for wire insulation also provides an assessment of the ability of an insulation to prevent damage in an electrical arc environment. In service, electrical arcs may originate form a variety of factors including insulation deterioration, faulty installation, and chafing. Here too, a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc with a vibrating blade. The test also evaluates the ability of the insulation to prevent further arc-propagation when the electrical arc is re-energized.

Beach, Rex↗